Alan B. Hollingsworth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alan B. Hollingsworth has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Abraham N. Morse
Aurora Healthcare US Corp, 8 Electronics Ave., Danvers, MA 01923, USA; Department of OBGYN, Tufts Medical Center, 800 Washington St, Boston, MA 02111, USA
3 shared publications - Fang-Ying Li
Aurora Healthcare US Corp, 8 Electronics Ave., Danvers, MA 01923, USA
2 shared publications Fang-Ying Li
Department of Research, Aurora Healthcare US Corp, Ijamsville, USA
1 shared publicationJing-Lung Wang
Radiology, Taitung Saint Mary's Hospital, Taitung, TWN
1 shared publicationLiang-Juan Chen
Administration, Taitung Saint Mary's Hospital, Taitung, TWN
1 shared publicationRebecca G. Stough-Clinton
Department of Clinical Imaging, Aurora Healthcare US Corp, Ijamsville, USA
1 shared publication
Latest Publications
- Open Access
- 4 April 2023
- Published by Springer Nature in Cureus
- Vol. 15 (4)
Breast Density Should Play a Greater Role in MRI Screening Guidelines
Guidelines for breast cancer screening with MRI were first proposed in 2007, only a few years after its clinical introduction. Those initial guidelines, which were generated by a committee sponsored by the American Cancer Society (ACS), have served as the template for similar recommendations by several organizations, with a singular goal regarding patient candidacy for MRI screening, a qualifying threshold based on risk stratification. Higher risk in those patients recommended for MRI screening translates to higher cancer detection rates, which in turn impacts cost-effectiveness. But there is another variable that should be as important as risk stratification in selecting patients for MRI screening: the probability that screening mammography will fail to detect developing cancer. That failure rate is a function of breast density, included in the MRI screening guidelines as a traditional risk factor but neglected when one considers its role as the primary cause of false-negative mammograms. The two implications of dense mammograms are essentially independent: (1) refining risk stratification and (2) predicting the “miss rate” of mammography. In the 2007 guidelines, indications for annual screening MRI, in addition to mammography, were based on patients having a calculated probability of “greater than 20-25% lifetime risk” for developing breast cancer. Other categorical risks, such as BRCA positivity, are listed in the ACS guidelines, but in effect, the threshold for adding MRI to the screening regimen has been a 20% lifetime risk for the development of breast cancer. While risk stratification in the original MRI screening guidelines had a number of inconsistencies, the focus herein is the questionable placement of high-density patients into the category described as “no policy for or against MRI, more research needed,” a category where lifetime risks were grouped as 15-19%. Thus, mammographic density was relegated to its role as a traditional risk factor, while its potentially more significant impact, predicting the “miss rate” of mammography, had no role in patient selection for screening MRI. The 2007 ACS guideline committee was limited by the lack of available data, and since there was no evidence for mortality reduction at the time, the decision was made to follow the patient selection criteria that had been used in the six international MRI screening trials, even though there was little consistency among those trials. Since then, the number of screening MRI trials has more than doubled, and new trials are being designed and implemented with a focus on both features of density: risk and cancer camouflage. Enough evidence has accumulated during the 16 years subsequent to the original ACS high-risk screening guidelines to consider a complete revision that accounts for both numerical risk levels and density levels, much like what was used in the ACRIN 6666 trial. In establishing a new set of guidelines, our first question should be: What is the “miss rate” of mammography in this patient? If the chance of a false-negative mammogram is as high as we see with Level D density, then the decision to include MRI becomes straightforward. The traditional risk assessment would then be used to help determine the optimal interval between MRI screens while maintaining cost-effective cancer detection rates.
- 4 April 2023
- Published by Springer Nature in Cureus
- Vol. 15 (4)
Open AccessBreast Density Should Play a Greater Role in MRI Screening Guidelines
Guidelines for breast cancer screening with MRI were first proposed in 2007, only a few years after its clinical introduction. Those initial guidelines, which were generated by a committee sponsored by the American Cancer Society (ACS), have served as the template for similar recommendations by several organizations, with a singular goal regarding patient candidacy for MRI screening, a qualifying threshold based on risk stratification. Higher risk in those patients recommended for MRI screening translates to higher cancer detection rates, which in turn impacts cost-effectiveness. But there is another variable that should be as important as risk stratification in selecting patients for MRI screening: the probability that screening mammography will fail to detect developing cancer. That failure rate is a function of breast density, included in the MRI screening guidelines as a traditional risk factor but neglected when one considers its role as the primary cause of false-negative mammograms. The two implications of dense mammograms are essentially independent: (1) refining risk stratification and (2) predicting the “miss rate” of mammography. In the 2007 guidelines, indications for annual screening MRI, in addition to mammography, were based on patients having a calculated probability of “greater than 20-25% lifetime risk” for developing breast cancer. Other categorical risks, such as BRCA positivity, are listed in the ACS guidelines, but in effect, the threshold for adding MRI to the screening regimen has been a 20% lifetime risk for the development of breast cancer. While risk stratification in the original MRI screening guidelines had a number of inconsistencies, the focus herein is the questionable placement of high-density patients into the category described as “no policy for or against MRI, more research needed,” a category where lifetime risks were grouped as 15-19%. Thus, mammographic density was relegated to its role as a traditional risk factor, while its potentially more significant impact, predicting the “miss rate” of mammography, had no role in patient selection for screening MRI. The 2007 ACS guideline committee was limited by the lack of available data, and since there was no evidence for mortality reduction at the time, the decision was made to follow the patient selection criteria that had been used in the six international MRI screening trials, even though there was little consistency among those trials. Since then, the number of screening MRI trials has more than doubled, and new trials are being designed and implemented with a focus on both features of density: risk and cancer camouflage. Enough evidence has accumulated during the 16 years subsequent to the original ACS high-risk screening guidelines to consider a complete revision that accounts for both numerical risk levels and density levels, much like what was used in the ACRIN 6666 trial. In establishing a new set of guidelines, our first question should be: What is the “miss rate” of mammography in this patient? If the chance of a false-negative mammogram is as high as we see with Level D density, then the decision to include MRI becomes straightforward. The traditional risk assessment would then be used to help determine the optimal interval between MRI screens while maintaining cost-effective cancer detection rates.
- 10 March 2022
- Published by Elsevier in Cancer Epidemiology
- Vol. 78, 102122
Lifetime risks for breast cancer are age-discriminatory when used for high-risk screening with MRI
- 10 March 2022
- Published by Elsevier in Cancer Epidemiology
- Vol. 78, 102122
Lifetime risks for breast cancer are age-discriminatory when used for high-risk screening with MRI
- Open Access
- 26 June 2021
- Published by Springer Nature in Cureus
- Vol. 13 (6) , e15940
Historical Origins for the Overestimation of Mammographic Sensitivity
The sensitivity of screening mammography for the early detection of breast cancer has improved over the years due to advances in technology. However, guidelines for screening mammography are often based on the mortality reductions demonstrated in the historic trials, where sensitivity with the first-generation mammography was relatively low. With attempts to establish risk:benefit ratios for population screening, it is important to understand the wide range of sensitivities that have been reported for mammography. Original calculations for mammographic sensitivity were often based on studies that included palpable tumors, thus generating inflated numbers not fully applicable to non-palpable tumors. If restricted to asymptomatic screening, sensitivity calculations were often based on the inverse of interval cancers, a relatively inaccurate method since breast cancers missed on mammography can remain undetected clinically for several years. It was not until multi-modality imaging was developed, primarily ultrasound and MRI, where sensitivity determinations could be made in real time by cross-checking outcomes with each modality. From this, it became apparent that there was a strong correlation between breast density levels and sensitivity levels, such that a single number to denote mammographic sensitivity was disingenuous. The increasing awareness that mortality reductions in the historic trials were achieved with a low sensitivity tool has prompted great interest in additional technologic improvements in mammography, as well as multi-modality imaging approaches for women with high density and/or high risk. In order to appreciate the potential benefit of these new approaches, it is helpful to understand the historical basis behind overestimating the sensitivity of screening mammography.
- 26 June 2021
- Published by Springer Nature in Cureus
- Vol. 13 (6) , e15940
Open AccessHistorical Origins for the Overestimation of Mammographic Sensitivity
The sensitivity of screening mammography for the early detection of breast cancer has improved over the years due to advances in technology. However, guidelines for screening mammography are often based on the mortality reductions demonstrated in the historic trials, where sensitivity with the first-generation mammography was relatively low. With attempts to establish risk:benefit ratios for population screening, it is important to understand the wide range of sensitivities that have been reported for mammography. Original calculations for mammographic sensitivity were often based on studies that included palpable tumors, thus generating inflated numbers not fully applicable to non-palpable tumors. If restricted to asymptomatic screening, sensitivity calculations were often based on the inverse of interval cancers, a relatively inaccurate method since breast cancers missed on mammography can remain undetected clinically for several years. It was not until multi-modality imaging was developed, primarily ultrasound and MRI, where sensitivity determinations could be made in real time by cross-checking outcomes with each modality. From this, it became apparent that there was a strong correlation between breast density levels and sensitivity levels, such that a single number to denote mammographic sensitivity was disingenuous. The increasing awareness that mortality reductions in the historic trials were achieved with a low sensitivity tool has prompted great interest in additional technologic improvements in mammography, as well as multi-modality imaging approaches for women with high density and/or high risk. In order to appreciate the potential benefit of these new approaches, it is helpful to understand the historical basis behind overestimating the sensitivity of screening mammography.
- Open Access
- 18 May 2021
- Published by Springer Nature in Cureus
- Vol. 13 (5)
Feasibility of Breast MRI as the Primary Imaging Modality in a Large Asian Cohort
Contrast-enhanced MRI has repeatedly demonstrated significantly enhanced sensitivity compared to mammography and ultrasound in breast cancer detection. The purpose of this study was to evaluate the feasibility and outcomes of using breast MRI as the initial imaging study for screening and diagnosis. In this retrospective review of a cohort of 10,374 breast MRI scans in 7967 patients in Taitung County, Taiwan, a total of 5619 participants met inclusion criteria and were included in our analysis. We reviewed all biopsies that were performed subsequent to MRI studies in women (screening vs. diagnostic). The primary outcomes were false-positive (FP) biopsy rates and positive predictive value (PPV) of MRI - parameters that have historically been associated with performance that restricts more widespread use of MRI. False-positive rate based on benign biopsies (FPR-3) and the positive predictive value (PPV-3) were calculated. Without complementary imaging or follow-up to identify false negatives, the study of performance characteristics was limited to false positives and PPV. There were 351 benign biopsies generated by MRI out of the cohort of 5555 participants (5619 minus the malignant biopsies), generating a false-positive rate of 6.3%. Sixty-four patients out of 415 biopsies were malignant, generating a PPV-3 of 15.4%. In this Asian cohort, utilizing breast MRI as the initial study for screening and/or diagnosis appears to be limited more by practical considerations such as cost and patient flow efficiency than by feasibility based on performance characteristics. With well-established superior sensitivity, coupled with improved interpretive skills and techniques that allow for low false-positive rates, MRI should be further studied for its role as the primary imaging modality in breast screening and diagnosis.
- 18 May 2021
- Published by Springer Nature in Cureus
- Vol. 13 (5)
Open AccessFeasibility of Breast MRI as the Primary Imaging Modality in a Large Asian Cohort
Contrast-enhanced MRI has repeatedly demonstrated significantly enhanced sensitivity compared to mammography and ultrasound in breast cancer detection. The purpose of this study was to evaluate the feasibility and outcomes of using breast MRI as the initial imaging study for screening and diagnosis. In this retrospective review of a cohort of 10,374 breast MRI scans in 7967 patients in Taitung County, Taiwan, a total of 5619 participants met inclusion criteria and were included in our analysis. We reviewed all biopsies that were performed subsequent to MRI studies in women (screening vs. diagnostic). The primary outcomes were false-positive (FP) biopsy rates and positive predictive value (PPV) of MRI - parameters that have historically been associated with performance that restricts more widespread use of MRI. False-positive rate based on benign biopsies (FPR-3) and the positive predictive value (PPV-3) were calculated. Without complementary imaging or follow-up to identify false negatives, the study of performance characteristics was limited to false positives and PPV. There were 351 benign biopsies generated by MRI out of the cohort of 5555 participants (5619 minus the malignant biopsies), generating a false-positive rate of 6.3%. Sixty-four patients out of 415 biopsies were malignant, generating a PPV-3 of 15.4%. In this Asian cohort, utilizing breast MRI as the initial study for screening and/or diagnosis appears to be limited more by practical considerations such as cost and patient flow efficiency than by feasibility based on performance characteristics. With well-established superior sensitivity, coupled with improved interpretive skills and techniques that allow for low false-positive rates, MRI should be further studied for its role as the primary imaging modality in breast screening and diagnosis.