Zachary T. Irwin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zachary T. Irwin has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Cynthia A. Chestek
University of Michigan
9 shared publications - Karen E. Schroeder
Department of Neuroscience, Columbia University Medical Center
5 shared publications - Jessica Nicole Bentley
Department of Neurosurgery, University of Alabama at Birmingham
4 shared publications - William C. Stacey
Department of Neurology University of Michigan Ann Arbor Michigan USA
4 shared publications Autumn J. Bullard
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States
3 shared publications- David Edward Thompson
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
3 shared publications
Latest Publications
- Open Access
Differential Contribution of Sensorimotor Cortex and Subthalamic Nucleus to Unimanual and Bimanual Hand Movements
Why does unilateral subthalamic nucleus deep brain stimulation improve motor function bilaterally? To address this clinical observation, we collected parallel neural recordings from sensorimotor cortex and the subthalamic nucleus during repetitive ipsilateral, contralateral, and bilateral hand movements in patients with Parkinson’s disease undergoing subthalamic nucleus deep brain stimulation. We used a cross-validated electrode-wise encoding model to map EMG data to the neural signals. Electrodes in the subthalamic nucleus encoded movement in a comparable manner for both hands during unimanual and bimanual movements, whereas sensorimotor cortex electrodes displayed a strong contralateral bias. To examine representational overlap in encoding across the two hands, we trained the model with data from one condition (contralateral hand) and used the trained weights to predict neural activity for movements produced with the other hand (ipsilateral hand). Overall, between-hand generalization was poor and this limitation was evident in both SMC and STN. A similar method was used to probe representational overlap across different task contexts (unimanual vs. bimanual). Task context was more important for the STN compared to the SMC indicating that neural activity in the STN showed greater divergence between the unimanual and bimanual conditions. These results indicate that whereas SMC activity is strongly lateralized and relatively context-free, STN integrates contextual information with the ongoing behavior. Significance Statement Unilateral subthalamic nucleus deep brain stimulation (DBS) improves both contralateral and ipsilateral motor symptoms of Parkinson’s disease. To explore mechanisms for bilateral improvement, parallel neural recordings from the sensorimotor cortex (SMC) and subthalamic nucleus (STN) were recorded in patients with Parkinson’s disease undergoing DBS. Neural activity and muscle activity from the hands were collected while patients performed unimanual and bimanual repetitive hand movements. Activity in SMC primarily encoded contralateral movements and was relatively context-free. In contrast, STN encoded movements in a comparable manner for both hands and was sensitive to the behavioral context.
Open AccessDifferential Contribution of Sensorimotor Cortex and Subthalamic Nucleus to Unimanual and Bimanual Hand Movements
Why does unilateral subthalamic nucleus deep brain stimulation improve motor function bilaterally? To address this clinical observation, we collected parallel neural recordings from sensorimotor cortex and the subthalamic nucleus during repetitive ipsilateral, contralateral, and bilateral hand movements in patients with Parkinson’s disease undergoing subthalamic nucleus deep brain stimulation. We used a cross-validated electrode-wise encoding model to map EMG data to the neural signals. Electrodes in the subthalamic nucleus encoded movement in a comparable manner for both hands during unimanual and bimanual movements, whereas sensorimotor cortex electrodes displayed a strong contralateral bias. To examine representational overlap in encoding across the two hands, we trained the model with data from one condition (contralateral hand) and used the trained weights to predict neural activity for movements produced with the other hand (ipsilateral hand). Overall, between-hand generalization was poor and this limitation was evident in both SMC and STN. A similar method was used to probe representational overlap across different task contexts (unimanual vs. bimanual). Task context was more important for the STN compared to the SMC indicating that neural activity in the STN showed greater divergence between the unimanual and bimanual conditions. These results indicate that whereas SMC activity is strongly lateralized and relatively context-free, STN integrates contextual information with the ongoing behavior. Significance Statement Unilateral subthalamic nucleus deep brain stimulation (DBS) improves both contralateral and ipsilateral motor symptoms of Parkinson’s disease. To explore mechanisms for bilateral improvement, parallel neural recordings from the sensorimotor cortex (SMC) and subthalamic nucleus (STN) were recorded in patients with Parkinson’s disease undergoing DBS. Neural activity and muscle activity from the hands were collected while patients performed unimanual and bimanual repetitive hand movements. Activity in SMC primarily encoded contralateral movements and was relatively context-free. In contrast, STN encoded movements in a comparable manner for both hands and was sensitive to the behavioral context.
- Open Access
- 15 February 2019
- Published by Springer Nature in Bioelectronic Medicine
- Vol. 5 (1) , 1-14
Design and testing of a 96-channel neural interface module for the Networked Neuroprosthesis system
The loss of motor functions resulting from spinal cord injury can have devastating implications on the quality of one’s life. Functional electrical stimulation has been used to help restore mobility, however, current functional electrical stimulation (FES) systems require residual movements to control stimulation patterns, which may be unintuitive and not useful for individuals with higher level cervical injuries. Brain machine interfaces (BMI) offer a promising approach for controlling such systems; however, they currently still require transcutaneous leads connecting indwelling electrodes to external recording devices. While several wireless BMI systems have been designed, high signal bandwidth requirements limit clinical translation. Case Western Reserve University has developed an implantable, modular FES system, the Networked Neuroprosthesis (NNP), to perform combinations of myoelectric recording and neural stimulation for controlling motor functions. However, currently the existing module capabilities are not sufficient for intracortical recordings. Here we designed and tested a 1 × 4 cm, 96-channel neural recording module prototype to fit within the specifications to mate with the NNP. The neural recording module extracts power between 0.3–1 kHz, instead of transmitting the raw, high bandwidth neural data to decrease power requirements. The module consumed 33.6 mW while sampling 96 channels at approximately 2 kSps. We also investigated the relationship between average spiking band power and neural spike rate, which produced a maximum correlation of R = 0.8656 (Monkey N) and R = 0.8023 (Monkey W). Our experimental results show that we can record and transmit 96 channels at 2ksps within the power restrictions of the NNP system and successfully communicate over the NNP network. We believe this device can be used as an extension to the NNP to produce a clinically viable, fully implantable, intracortically-controlled FES system and advance the field of bioelectronic medicine.
- 15 February 2019
- Published by Springer Nature in Bioelectronic Medicine
- Vol. 5 (1) , 1-14
Open AccessDesign and testing of a 96-channel neural interface module for the Networked Neuroprosthesis system
The loss of motor functions resulting from spinal cord injury can have devastating implications on the quality of one’s life. Functional electrical stimulation has been used to help restore mobility, however, current functional electrical stimulation (FES) systems require residual movements to control stimulation patterns, which may be unintuitive and not useful for individuals with higher level cervical injuries. Brain machine interfaces (BMI) offer a promising approach for controlling such systems; however, they currently still require transcutaneous leads connecting indwelling electrodes to external recording devices. While several wireless BMI systems have been designed, high signal bandwidth requirements limit clinical translation. Case Western Reserve University has developed an implantable, modular FES system, the Networked Neuroprosthesis (NNP), to perform combinations of myoelectric recording and neural stimulation for controlling motor functions. However, currently the existing module capabilities are not sufficient for intracortical recordings. Here we designed and tested a 1 × 4 cm, 96-channel neural recording module prototype to fit within the specifications to mate with the NNP. The neural recording module extracts power between 0.3–1 kHz, instead of transmitting the raw, high bandwidth neural data to decrease power requirements. The module consumed 33.6 mW while sampling 96 channels at approximately 2 kSps. We also investigated the relationship between average spiking band power and neural spike rate, which produced a maximum correlation of R = 0.8656 (Monkey N) and R = 0.8023 (Monkey W). Our experimental results show that we can record and transmit 96 channels at 2ksps within the power restrictions of the NNP system and successfully communicate over the NNP network. We believe this device can be used as an extension to the NNP to produce a clinically viable, fully implantable, intracortically-controlled FES system and advance the field of bioelectronic medicine.
- Open Access
- 5 November 2018
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 12, 751
Cortical Decoding of Individual Finger Group Motions Using ReFIT Kalman Filter
Objective: To date, many brain-machine interface (BMI) studies have developed decoding algorithms for neuroprostheses that provide users with precise control of upper arm reaches with some limited grasping capabilities. However, comparatively few have focused on quantifying the performance of precise finger control. Here we expand upon this work by investigating online control of individual finger groups. Approach: We have developed a novel training manipulandum for non-human primate (NHP) studies to isolate the movements of two specific finger groups: index and middle-ring-pinkie (MRP) fingers. We use this device in combination with the ReFIT (Recalibrated Feedback Intention-Trained) Kalman filter to decode the position of each finger group during a single degree of freedom task in two rhesus macaques with Utah arrays in motor cortex. The ReFIT Kalman filter uses a two-stage training approach that improves online control of upper arm tasks with substantial reductions in orbiting time, thus making it a logical first choice for precise finger control. Results: Both animals were able to reliably acquire fingertip targets with both index and MRP fingers, which they did in blocks of finger group specific trials. Decoding from motor signals online, the ReFIT Kalman filter reliably outperformed the standard Kalman filter, measured by bit rate, across all tested finger groups and movements by 31.0 and 35.2%. These decoders were robust when the manipulandum was removed during online control. While index finger movements and middle-ring-pinkie finger movements could be differentiated from each other with 81.7% accuracy across both subjects, the linear Kalman filter was not sufficient for decoding both finger groups together due to significant unwanted movement in the stationary finger, potentially due to co-contraction. Significance: To our knowledge, this is the first systematic and biomimetic separation of digits for continuous online decoding in a NHP as well as the first demonstration of the ReFIT Kalman filter improving the performance of precise finger decoding. These results suggest that novel nonlinear approaches, apparently not necessary for center out reaches or gross hand motions, may be necessary to achieve independent and precise control of individual fingers.
- 5 November 2018
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 12, 751
Open AccessCortical Decoding of Individual Finger Group Motions Using ReFIT Kalman Filter
Objective: To date, many brain-machine interface (BMI) studies have developed decoding algorithms for neuroprostheses that provide users with precise control of upper arm reaches with some limited grasping capabilities. However, comparatively few have focused on quantifying the performance of precise finger control. Here we expand upon this work by investigating online control of individual finger groups. Approach: We have developed a novel training manipulandum for non-human primate (NHP) studies to isolate the movements of two specific finger groups: index and middle-ring-pinkie (MRP) fingers. We use this device in combination with the ReFIT (Recalibrated Feedback Intention-Trained) Kalman filter to decode the position of each finger group during a single degree of freedom task in two rhesus macaques with Utah arrays in motor cortex. The ReFIT Kalman filter uses a two-stage training approach that improves online control of upper arm tasks with substantial reductions in orbiting time, thus making it a logical first choice for precise finger control. Results: Both animals were able to reliably acquire fingertip targets with both index and MRP fingers, which they did in blocks of finger group specific trials. Decoding from motor signals online, the ReFIT Kalman filter reliably outperformed the standard Kalman filter, measured by bit rate, across all tested finger groups and movements by 31.0 and 35.2%. These decoders were robust when the manipulandum was removed during online control. While index finger movements and middle-ring-pinkie finger movements could be differentiated from each other with 81.7% accuracy across both subjects, the linear Kalman filter was not sufficient for decoding both finger groups together due to significant unwanted movement in the stationary finger, potentially due to co-contraction. Significance: To our knowledge, this is the first systematic and biomimetic separation of digits for continuous online decoding in a NHP as well as the first demonstration of the ReFIT Kalman filter improving the performance of precise finger decoding. These results suggest that novel nonlinear approaches, apparently not necessary for center out reaches or gross hand motions, may be necessary to achieve independent and precise control of individual fingers.
- Open Access
- 1 June 2018
- Published by Springer Nature in Nature Communications
- Vol. 9 (1) , 1-14
Variability in the location of high frequency oscillations during prolonged intracranial EEG recordings
The rate of interictal high frequency oscillations (HFOs) is a promising biomarker of the seizure onset zone, though little is known about its consistency over hours to days. Here we test whether the highest HFO-rate channels are consistent across different 10-min segments of EEG during sleep. An automated HFO detector and blind source separation are applied to nearly 3000 total hours of data from 121 subjects, including 12 control subjects without epilepsy. Although interictal HFOs are significantly correlated with the seizure onset zone, the precise localization is consistent in only 22% of patients. The remaining patients either have one intermittent source (16%), different sources varying over time (45%), or insufficient HFOs (17%). Multiple HFO networks are found in patients with both one and multiple seizure foci. These results indicate that robust HFO interpretation requires prolonged analysis in context with other clinical data, rather than isolated review of short data segments.
- 1 June 2018
- Published by Springer Nature in Nature Communications
- Vol. 9 (1) , 1-14
Open AccessVariability in the location of high frequency oscillations during prolonged intracranial EEG recordings
The rate of interictal high frequency oscillations (HFOs) is a promising biomarker of the seizure onset zone, though little is known about its consistency over hours to days. Here we test whether the highest HFO-rate channels are consistent across different 10-min segments of EEG during sleep. An automated HFO detector and blind source separation are applied to nearly 3000 total hours of data from 121 subjects, including 12 control subjects without epilepsy. Although interictal HFOs are significantly correlated with the seizure onset zone, the precise localization is consistent in only 22% of patients. The remaining patients either have one intermittent source (16%), different sources varying over time (45%), or insufficient HFOs (17%). Multiple HFO networks are found in patients with both one and multiple seizure foci. These results indicate that robust HFO interpretation requires prolonged analysis in context with other clinical data, rather than isolated review of short data segments.
- Open Access
- 13 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 26 (2) , 515-526
Closed-Loop Continuous Hand Control via Chronic Recording of Regenerative Peripheral Nerve Interfaces
Loss of the upper limb imposes a devastating interruption to everyday life. Full restoration of natural arm control requires the ability to simultaneously control multiple degrees of freedom (DOFs) of the prosthetic arm and maintain that control over an extended period of time. Current clinically available myoelectric prostheses do not provide simultaneous control or consistency for transradial amputees. To address this issue, we have implemented a standard Kalman filter for continuous hand control using intramuscular electromyography (EMG) from both regenerative peripheral nerve interfaces (RPNI) and an intact muscle within non-human primates. Seven RPNIs and one intact muscle were implanted with indwelling bipolar intramuscular electrodes in two rhesus macaques. Following recuperations, function-specific EMG signals were recorded and then fed through the Kalman filter during a hand-movement behavioral-task to continuously predict the monkey’s finger position. We were able to reconstruct continuous finger movement offline with an average correlation of ρ= 0.87 and root mean squared error (RMSE) of 0.12 between actual and predicted position from two macaques. This finger movement prediction was also performed in real-time to enable closed-loop neural control of a virtual hand. Compared to physical hand control, neural control performance was slightly slower but maintained an average target hit success rate of 96.70%. Recalibration longevity measurements maintained consistent average correlation over time but had a significant change in RMSE (p < 0.05). Additionally, extracted single units varied in amplitude by a factor of +18.65% and –25.85% compared to its mean. This is the first demonstration of chronic indwelling electrodes being used for continuous position control via the Kalman filter. Combining these analyses with our novel peripheral nerve interface, we believe that this demonstrates an important step in providing patients with more naturalistic control of their prosthetic limbs.
- 13 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 26 (2) , 515-526
Open AccessClosed-Loop Continuous Hand Control via Chronic Recording of Regenerative Peripheral Nerve Interfaces
Loss of the upper limb imposes a devastating interruption to everyday life. Full restoration of natural arm control requires the ability to simultaneously control multiple degrees of freedom (DOFs) of the prosthetic arm and maintain that control over an extended period of time. Current clinically available myoelectric prostheses do not provide simultaneous control or consistency for transradial amputees. To address this issue, we have implemented a standard Kalman filter for continuous hand control using intramuscular electromyography (EMG) from both regenerative peripheral nerve interfaces (RPNI) and an intact muscle within non-human primates. Seven RPNIs and one intact muscle were implanted with indwelling bipolar intramuscular electrodes in two rhesus macaques. Following recuperations, function-specific EMG signals were recorded and then fed through the Kalman filter during a hand-movement behavioral-task to continuously predict the monkey’s finger position. We were able to reconstruct continuous finger movement offline with an average correlation of ρ= 0.87 and root mean squared error (RMSE) of 0.12 between actual and predicted position from two macaques. This finger movement prediction was also performed in real-time to enable closed-loop neural control of a virtual hand. Compared to physical hand control, neural control performance was slightly slower but maintained an average target hit success rate of 96.70%. Recalibration longevity measurements maintained consistent average correlation over time but had a significant change in RMSE (p < 0.05). Additionally, extracted single units varied in amplitude by a factor of +18.65% and –25.85% compared to its mean. This is the first demonstration of chronic indwelling electrodes being used for continuous position control via the Kalman filter. Combining these analyses with our novel peripheral nerve interface, we believe that this demonstrates an important step in providing patients with more naturalistic control of their prosthetic limbs.
- 1 November 2017
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 14 (6) , 066004
Neural control of finger movement via intracortical brain–machine interface
Objective . Intracortical brain–machine interfaces (BMIs) are a promising source of prosthesis control signals for individuals with severe motor disabilities. Previous BMI studies have primarily focused on predicting and controlling whole-arm movements; precise control of hand kinematics, however, has not been fully demonstrated. Here, we investigate the continuous decoding of precise finger movements in rhesus macaques. Approach . In order to elicit precise and repeatable finger movements, we have developed a novel behavioral task paradigm which requires the subject to acquire virtual fingertip position targets. In the physical control condition, four rhesus macaques performed this task by moving all four fingers together in order to acquire a single target. This movement was equivalent to controlling the aperture of a power grasp. During this task performance, we recorded neural spikes from intracortical electrode arrays in primary motor cortex. Main results . Using a standard Kalman filter, we could reconstruct continuous finger movement offline with an average correlation of ρ = 0.78 between actual and predicted position across four rhesus macaques. For two of the monkeys, this movement prediction was performed in real-time to enable direct brain control of the virtual hand. Compared to physical control, neural control performance was slightly degraded; however, the monkeys were still able to successfully perform the task with an average target acquisition rate of 83.1%. The monkeys’ ability to arbitrarily specify fingertip position was also quantified using an information throughput metric. During brain control task performance, the monkeys achieved an average 1.01 bits s −1 throughput, similar to that achieved in previous studies which decoded upper-arm movements to control computer cursors using a standard Kalman filter. Significance . This is, to our knowledge, the first demonstration of brain control of finger-level fine motor skills. We believe that these results represent an important step towards full and dexterous control of neural prosthetic devices.
- 1 November 2017
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 14 (6) , 066004
Neural control of finger movement via intracortical brain–machine interface
Objective . Intracortical brain–machine interfaces (BMIs) are a promising source of prosthesis control signals for individuals with severe motor disabilities. Previous BMI studies have primarily focused on predicting and controlling whole-arm movements; precise control of hand kinematics, however, has not been fully demonstrated. Here, we investigate the continuous decoding of precise finger movements in rhesus macaques. Approach . In order to elicit precise and repeatable finger movements, we have developed a novel behavioral task paradigm which requires the subject to acquire virtual fingertip position targets. In the physical control condition, four rhesus macaques performed this task by moving all four fingers together in order to acquire a single target. This movement was equivalent to controlling the aperture of a power grasp. During this task performance, we recorded neural spikes from intracortical electrode arrays in primary motor cortex. Main results . Using a standard Kalman filter, we could reconstruct continuous finger movement offline with an average correlation of ρ = 0.78 between actual and predicted position across four rhesus macaques. For two of the monkeys, this movement prediction was performed in real-time to enable direct brain control of the virtual hand. Compared to physical control, neural control performance was slightly degraded; however, the monkeys were still able to successfully perform the task with an average target acquisition rate of 83.1%. The monkeys’ ability to arbitrarily specify fingertip position was also quantified using an information throughput metric. During brain control task performance, the monkeys achieved an average 1.01 bits s −1 throughput, similar to that achieved in previous studies which decoded upper-arm movements to control computer cursors using a standard Kalman filter. Significance . This is, to our knowledge, the first demonstration of brain control of finger-level fine motor skills. We believe that these results represent an important step towards full and dexterous control of neural prosthetic devices.
- 6 June 2017
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 14 (4) , 046016
Robust tactile sensory responses in finger area of primate motor cortex relevant to prosthetic control
Objective. Challenges in improving the performance of dexterous upper-limb brain–machine interfaces (BMIs) have prompted renewed interest in quantifying the amount and type of sensory information naturally encoded in the primary motor cortex (M1). Previous single unit studies in monkeys showed M1 is responsive to tactile stimulation, as well as passive and active movement of the limbs. However, recent work in this area has focused primarily on proprioception. Here we examined instead how tactile somatosensation of the hand and fingers is represented in M1. Approach. We recorded multi- and single units and thresholded neural activity from macaque M1 while gently brushing individual finger pads at 2 Hz. We also recorded broadband neural activity from electrocorticogram (ECoG) grids placed on human motor cortex, while applying the same tactile stimulus. Main results. Units displaying significant differences in firing rates between individual fingers (p < 0.05) represented up to 76.7% of sorted multiunits across four monkeys. After normalizing by the number of channels with significant motor finger responses, the percentage of electrodes with significant tactile responses was 74.9% ± 24.7%. No somatotopic organization of finger preference was obvious across cortex, but many units exhibited cosine-like tuning across multiple digits. Sufficient sensory information was present in M1 to correctly decode stimulus position from multiunit activity above chance levels in all monkeys, and also from ECoG gamma power in two human subjects. Significance. These results provide some explanation for difficulties experienced by motor decoders in clinical trials of cortically controlled prosthetic hands, as well as the general problem of disentangling motor and sensory signals in primate motor cortex during dextrous tasks. Additionally, examination of unit tuning during tactile and proprioceptive inputs indicates cells are often tuned differently in different contexts, reinforcing the need for continued refinement of BMI training and decoding approaches to closed-loop BMI systems for dexterous grasping.
- 6 June 2017
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 14 (4) , 046016
Robust tactile sensory responses in finger area of primate motor cortex relevant to prosthetic control
Objective. Challenges in improving the performance of dexterous upper-limb brain–machine interfaces (BMIs) have prompted renewed interest in quantifying the amount and type of sensory information naturally encoded in the primary motor cortex (M1). Previous single unit studies in monkeys showed M1 is responsive to tactile stimulation, as well as passive and active movement of the limbs. However, recent work in this area has focused primarily on proprioception. Here we examined instead how tactile somatosensation of the hand and fingers is represented in M1. Approach. We recorded multi- and single units and thresholded neural activity from macaque M1 while gently brushing individual finger pads at 2 Hz. We also recorded broadband neural activity from electrocorticogram (ECoG) grids placed on human motor cortex, while applying the same tactile stimulus. Main results. Units displaying significant differences in firing rates between individual fingers (p < 0.05) represented up to 76.7% of sorted multiunits across four monkeys. After normalizing by the number of channels with significant motor finger responses, the percentage of electrodes with significant tactile responses was 74.9% ± 24.7%. No somatotopic organization of finger preference was obvious across cortex, but many units exhibited cosine-like tuning across multiple digits. Sufficient sensory information was present in M1 to correctly decode stimulus position from multiunit activity above chance levels in all monkeys, and also from ECoG gamma power in two human subjects. Significance. These results provide some explanation for difficulties experienced by motor decoders in clinical trials of cortically controlled prosthetic hands, as well as the general problem of disentangling motor and sensory signals in primate motor cortex during dextrous tasks. Additionally, examination of unit tuning during tactile and proprioceptive inputs indicates cells are often tuned differently in different contexts, reinforcing the need for continued refinement of BMI training and decoding approaches to closed-loop BMI systems for dexterous grasping.
- 18 May 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10194, 1019415-1019415-7
Development of regenerative peripheral nerve interfaces for motor control of neuroprosthetic devices
- 18 May 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10194, 1019415-1019415-7
Development of regenerative peripheral nerve interfaces for motor control of neuroprosthetic devices
- 1 September 2016
- Published by Elsevier in Clinical Neurophysiology
- Vol. 127 (9) , 3042-3050
Effect of sampling rate and filter settings on High Frequency Oscillation detections
- 1 September 2016
- Published by Elsevier in Clinical Neurophysiology
- Vol. 127 (9) , 3042-3050
Effect of sampling rate and filter settings on High Frequency Oscillation detections
- 1 July 2016
- Published by Elsevier in NeuroImage
- Vol. 134, 459-465
Disruption of corticocortical information transfer during ketamine anesthesia in the primate brain
- 1 July 2016
- Published by Elsevier in NeuroImage
- Vol. 134, 459-465
Disruption of corticocortical information transfer during ketamine anesthesia in the primate brain