Bo Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bo Wu has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Eddie Siu-Shu Lam
Department of Civil and Structural Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong
3 shared publications Fentao Liu
State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou, People's Republic of China
3 shared publicationsJian-Bo Zang
2 shared publicationsZhen Li
State Key Laboratory of Subtropical Building Science, School of Civil Engineering and Transportation, South China University of Technology, Guangzhou, People’s Republic of China
2 shared publicationsZhikai Wei
School of Civil Engineering and Transportation, South China University of Technology, Guangzhou, China
2 shared publicationsBang Yan Ye
South China University of Technology
1 shared publication
Latest Publications
- 10 January 2024
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 27 (4) , 565-584
Mesoscale modeling of flexural fracture behavior in steel fiber reinforced concrete
This paper presents a computational study on the flexural fracture behaviors of steel fiber reinforced concrete (SFRC). The focus is on investigating the impacts of various factors on SFRC, utilizing a discrete-continuum coupled finite element method. This method explicitly models each material phase, including coarse aggregates, mortar paste, steel fibers and interfacial transition zones (ITZs), allowing precise tracking of mesoscale cracking during bending. The simulation method is developed, calibrated and validated before conducting a parametric investigation. Critical factors considered include the spatial positioning of coarse aggregates and steel fibers, fiber content, length and diameter, and the bonding property of fiber-mortar ITZs. Results indicate that steel fibers modify crack development in notched beams, causing greater distortion in the primary crack. Increasing fiber content from 0 to 2% enhances flexural tensile strength but introduces more variability. Longer fibers initially increase strength, then decrease, while thicker fibers consistently reduce strength. Improving the bond between fibers and mortar does not substantially increase the load-bearing capacity of the beam. In conclusion, this study shows how the established approach enhances understanding of the mechanical responses of SFRC under flexural-fracture loading.
- 10 January 2024
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 27 (4) , 565-584
Mesoscale modeling of flexural fracture behavior in steel fiber reinforced concrete
This paper presents a computational study on the flexural fracture behaviors of steel fiber reinforced concrete (SFRC). The focus is on investigating the impacts of various factors on SFRC, utilizing a discrete-continuum coupled finite element method. This method explicitly models each material phase, including coarse aggregates, mortar paste, steel fibers and interfacial transition zones (ITZs), allowing precise tracking of mesoscale cracking during bending. The simulation method is developed, calibrated and validated before conducting a parametric investigation. Critical factors considered include the spatial positioning of coarse aggregates and steel fibers, fiber content, length and diameter, and the bonding property of fiber-mortar ITZs. Results indicate that steel fibers modify crack development in notched beams, causing greater distortion in the primary crack. Increasing fiber content from 0 to 2% enhances flexural tensile strength but introduces more variability. Longer fibers initially increase strength, then decrease, while thicker fibers consistently reduce strength. Improving the bond between fibers and mortar does not substantially increase the load-bearing capacity of the beam. In conclusion, this study shows how the established approach enhances understanding of the mechanical responses of SFRC under flexural-fracture loading.
- 15 June 2023
- Published by Elsevier in Construction and Building Materials
- Vol. 393
Fracture and flexural behaviors of recycled lump-aggregate concrete
- 15 June 2023
- Published by Elsevier in Construction and Building Materials
- Vol. 393
Fracture and flexural behaviors of recycled lump-aggregate concrete
- 22 March 2023
- Published by Elsevier in Engineering Structures
- Vol. 284
Shear strength of square concrete-filled steel tubular columns reinforced with internal steel stirrups
- 22 March 2023
- Published by Elsevier in Engineering Structures
- Vol. 284
Shear strength of square concrete-filled steel tubular columns reinforced with internal steel stirrups
- Open Access
- 11 October 2022
- Published by Frontiers Media SA in Frontiers in Materials
- Vol. 9
Fire resistance of composite shear walls filled with demolished concrete lumps and self-compacting concrete
The recycling and reuse of waste concrete is conducive to promoting the sustainable development of resources and practicing the concept of green development. Demolished concrete lumps (DCLs) and self-compacting concrete (SCC) made from waste concrete take full advantage of their recyclability. In order to fully utilize the advantages of demolished concrete lumps and self-compacting concrete in construction, applying demolished concrete lumps and self-compacting concrete to composite shear wall structures is an effective way to reduce costs and improve industrial production. In this paper, a new composite shear wall filled with demolished concrete lumps and self-compacting concrete is proposed, and its fire performance is investigated. The shear wall combines edge constraints of concrete-filled steel tubes, demolished concrete lumps and self-compacting concrete. In order to facilitate the mass pouring of demolished concrete lumps, a cavity is formed between the steel tubes at the ends and the precast walls on both sides. A double-sided fire tests was conducted on three composite shear wall specimens filled with demolished concrete lumps and self-compacting concrete at a constant axial compression ratio, where the fire-retardant coating and the wall width-to-depth ratio were considered as the main test parameters. The specimens were able to steadily withstand the predetermined axial loads during the fire resistance time of 180 min and showed good fire resistance. The concrete temperature variation trends of the three specimens in the wall section were basically the same. The fire-retardant coating on the concealed column had a significant effect on the section temperature of the steel tube, while increasing the wall width-to-depth ratio had little effect. When the axial compression ratio was 0.19, the specimens were in the expansion stage within 180 min and no compression occurred. The results show that the expansion deformation of the shear wall sprayed with fire-retardant coating on the outer surface of the concealed column is smaller than that of the shear wall without fire-retardant coating, and the axial deformation of the composite shear wall infilled with demolished concrete lumps and self-compacting concrete is not affected by increasing the wall width-to-depth ratio.
- 11 October 2022
- Published by Frontiers Media SA in Frontiers in Materials
- Vol. 9
Open AccessFire resistance of composite shear walls filled with demolished concrete lumps and self-compacting concrete
The recycling and reuse of waste concrete is conducive to promoting the sustainable development of resources and practicing the concept of green development. Demolished concrete lumps (DCLs) and self-compacting concrete (SCC) made from waste concrete take full advantage of their recyclability. In order to fully utilize the advantages of demolished concrete lumps and self-compacting concrete in construction, applying demolished concrete lumps and self-compacting concrete to composite shear wall structures is an effective way to reduce costs and improve industrial production. In this paper, a new composite shear wall filled with demolished concrete lumps and self-compacting concrete is proposed, and its fire performance is investigated. The shear wall combines edge constraints of concrete-filled steel tubes, demolished concrete lumps and self-compacting concrete. In order to facilitate the mass pouring of demolished concrete lumps, a cavity is formed between the steel tubes at the ends and the precast walls on both sides. A double-sided fire tests was conducted on three composite shear wall specimens filled with demolished concrete lumps and self-compacting concrete at a constant axial compression ratio, where the fire-retardant coating and the wall width-to-depth ratio were considered as the main test parameters. The specimens were able to steadily withstand the predetermined axial loads during the fire resistance time of 180 min and showed good fire resistance. The concrete temperature variation trends of the three specimens in the wall section were basically the same. The fire-retardant coating on the concealed column had a significant effect on the section temperature of the steel tube, while increasing the wall width-to-depth ratio had little effect. When the axial compression ratio was 0.19, the specimens were in the expansion stage within 180 min and no compression occurred. The results show that the expansion deformation of the shear wall sprayed with fire-retardant coating on the outer surface of the concealed column is smaller than that of the shear wall without fire-retardant coating, and the axial deformation of the composite shear wall infilled with demolished concrete lumps and self-compacting concrete is not affected by increasing the wall width-to-depth ratio.
- 21 September 2022
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 26 (3) , 413-427
An experimental study of the shear behavior of joints in precast concrete columns
The shear behavior of joints in precast concrete columns with a new type of column-to-column connection was investigated in this research. Shear tests were performed with 12 precast concrete columns. The influences of the shear key width (0, 70 mm, 100 mm), the diameter of the reinforcement across the joint (0, 16 mm) and the axial compression load ratio (0.3, 0.4, 0.5) on the shear performance of the joint were studied. An expression to give the prediction of the shear capacity of such joints is proposed. The data show that: (1) shear keys have a huge influence on the shear capacity of precast column joints, but the increment of shear capacity due to such influence is limited over a range of shear key widths from 70 to 100 mm; (2) when the axial compression load ratio does not exceed 0.5, a joint’s shear capacity enhances gradually with the load ratio; (3) the expression developed in these experiments outperforms those recommended by four widely-used codes in giving the prediction of the shear capacity of column-to-column connections with shear keys, reinforcement across the joint and grouting.
- 21 September 2022
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 26 (3) , 413-427
An experimental study of the shear behavior of joints in precast concrete columns
The shear behavior of joints in precast concrete columns with a new type of column-to-column connection was investigated in this research. Shear tests were performed with 12 precast concrete columns. The influences of the shear key width (0, 70 mm, 100 mm), the diameter of the reinforcement across the joint (0, 16 mm) and the axial compression load ratio (0.3, 0.4, 0.5) on the shear performance of the joint were studied. An expression to give the prediction of the shear capacity of such joints is proposed. The data show that: (1) shear keys have a huge influence on the shear capacity of precast column joints, but the increment of shear capacity due to such influence is limited over a range of shear key widths from 70 to 100 mm; (2) when the axial compression load ratio does not exceed 0.5, a joint’s shear capacity enhances gradually with the load ratio; (3) the expression developed in these experiments outperforms those recommended by four widely-used codes in giving the prediction of the shear capacity of column-to-column connections with shear keys, reinforcement across the joint and grouting.
- 20 November 2021
- Published by Springer Nature in Materials and Structures
- Vol. 54 (6) , 1-17
The direct shear behavior of recycled lump concrete
- 20 November 2021
- Published by Springer Nature in Materials and Structures
- Vol. 54 (6) , 1-17
The direct shear behavior of recycled lump concrete
- 15 June 2021
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 24 (14) , 3281-3298
Flexural behavior of reinforced geopolymer concrete beams with recycled coarse aggregates
Geopolymer recycled aggregate concrete (GRAC) is a new green construction material, which uses geopolymer as the binder and recycled concrete as aggregates. To compare the flexural performance of GRAC and ordinary recycled aggregate concrete (RAC) beams, static loading tests were conducted on seven GRAC beams and three RAC beams. The effects of the replacement ratio of recycled aggregates (RAs), the replacement patterns, and the reinforcement ratio on the flexural behavior of GRAC beams are evaluated. The test data show that the replacement ratio has no significant effect on the cracking pattern, failure mode, or bending capacity of GRAC beams, but the replacement pattern does have an effect. Under a given replacement ratio, replacing only the larger fraction of natural aggregates (NA) with RA improves the concrete strength and crack resistance of both RAC and GRAC beams, compared to that using same replacement percentage for all fractions. Due to the lower elastic modulus and strength of GRAC prepared in this study, the GRAC beams have lower height of neutral axis and greater deflection than RAC beams at the same load level and possess slightly lower cracking load, bending capacity, and ductility. The bending capacity of GRAC beams can be predicted by the formulas proposed for ordinary reinforced concrete beams in the Chinese code GB50010-2010, ACI 318-11, or BS EN 1992-1-1:2004 codes, but the safety margin is generally lower than that of ordinary reinforced concrete beams.
- 15 June 2021
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 24 (14) , 3281-3298
Flexural behavior of reinforced geopolymer concrete beams with recycled coarse aggregates
Geopolymer recycled aggregate concrete (GRAC) is a new green construction material, which uses geopolymer as the binder and recycled concrete as aggregates. To compare the flexural performance of GRAC and ordinary recycled aggregate concrete (RAC) beams, static loading tests were conducted on seven GRAC beams and three RAC beams. The effects of the replacement ratio of recycled aggregates (RAs), the replacement patterns, and the reinforcement ratio on the flexural behavior of GRAC beams are evaluated. The test data show that the replacement ratio has no significant effect on the cracking pattern, failure mode, or bending capacity of GRAC beams, but the replacement pattern does have an effect. Under a given replacement ratio, replacing only the larger fraction of natural aggregates (NA) with RA improves the concrete strength and crack resistance of both RAC and GRAC beams, compared to that using same replacement percentage for all fractions. Due to the lower elastic modulus and strength of GRAC prepared in this study, the GRAC beams have lower height of neutral axis and greater deflection than RAC beams at the same load level and possess slightly lower cracking load, bending capacity, and ductility. The bending capacity of GRAC beams can be predicted by the formulas proposed for ordinary reinforced concrete beams in the Chinese code GB50010-2010, ACI 318-11, or BS EN 1992-1-1:2004 codes, but the safety margin is generally lower than that of ordinary reinforced concrete beams.
- 18 May 2021
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 24 (13) , 2981-2995
An experimental study of the axial compression performance of two-part precast concrete columns
Recycled lump concrete (RLC) made with demolished concrete lumps (DCLs) and fresh concrete (FC) provides a solution for effective waste concrete recycling. To promote the development of precast RLC structures, this study tested a new type of connection for precast concrete columns: connecting the upper and the lower halves of columns with bent longitudinal reinforcements and structural adhesive. In this work the behavior of precast RLC columns with the new connection was studied under axial compression. The axial compressive strength of nine two-part columns was tested. The effects of the degree of bending in the longitudinal reinforcement, the replacement ratio of DCLs and the stirrup spacing were investigated. Tests showed that: (1) the failure mode of precast concrete columns is different from that of cast-in-place columns; (2) when the strength of the waste concrete is close to that of the fresh material, there is no significant difference in the axial compression performance of either precast or cast-in-place columns; (3) the bent longitudinal reinforcement causes the axial load bearing capacity of precast concrete columns to be 4.2%–12.3% lower than that of a similar cast-in-place column; (4) reducing the stirrup spacing has little effect on a precast column’s axial load bearing capacity and ductility; (5) when using Chinese and American codes to predict the axial load bearing capacity of the column, the predicted value should be multiplied by a reduction factor.
- 18 May 2021
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 24 (13) , 2981-2995
An experimental study of the axial compression performance of two-part precast concrete columns
Recycled lump concrete (RLC) made with demolished concrete lumps (DCLs) and fresh concrete (FC) provides a solution for effective waste concrete recycling. To promote the development of precast RLC structures, this study tested a new type of connection for precast concrete columns: connecting the upper and the lower halves of columns with bent longitudinal reinforcements and structural adhesive. In this work the behavior of precast RLC columns with the new connection was studied under axial compression. The axial compressive strength of nine two-part columns was tested. The effects of the degree of bending in the longitudinal reinforcement, the replacement ratio of DCLs and the stirrup spacing were investigated. Tests showed that: (1) the failure mode of precast concrete columns is different from that of cast-in-place columns; (2) when the strength of the waste concrete is close to that of the fresh material, there is no significant difference in the axial compression performance of either precast or cast-in-place columns; (3) the bent longitudinal reinforcement causes the axial load bearing capacity of precast concrete columns to be 4.2%–12.3% lower than that of a similar cast-in-place column; (4) reducing the stirrup spacing has little effect on a precast column’s axial load bearing capacity and ductility; (5) when using Chinese and American codes to predict the axial load bearing capacity of the column, the predicted value should be multiplied by a reduction factor.