Johannes Amann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Johannes Amann has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Schütze
Saarland University
8 shared publications - Caroline Schultealbert
Lab for Measurement Technology, Saarland University, Campus A5 1, 66123 Saarbrücken, Germany
4 shared publications - Tizian Schneider
Lab for Measurement Technology, Saarland University, Campus A5 1, 66123 Saarbrücken, Germany
4 shared publications - Tobias Baur
Lab for Measurement Technology, Saarland University, Campus A5 1, 66123 Saarbrücken, Germany
4 shared publications - Yannick Robin
Systems Neuroscience & Neurotechnology Unit, Saarland University Medical Faculty & htw saar, 66421 Homburg/Saar, Germany and with the htw saar, School of Engineering, 66117 Saarbrücken, Germany
4 shared publications Caroline Schultealbert
3 shared publications
Latest Publications
- Open Access
- 17 July 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (30) , 15730-15740
Tagging Emissions from Indoor Biomass Combustion with a Cost-Effective Sensor Array: From Design to Field Deployment in Rural Indian Households
In this study, we introduce an innovative method for monitoring emissions from indoor biomass combustion, a prevalent practice in rural households in the Indo-Gangetic Plains. Our approach utilizes a portable and cost-efficient sensor array with advanced data handling, employing commercially available sensors to measure CO2, CO, NO2, SO2, PMs, VOC, NOx, cookstove and ambient temperature, relative humidity, and pressure. We developed hardware and software to gather and process sensor data and control the temperature cycle using the BME688 sensors. The field deployments reveal that CO2 emission from a cooking event is ∼2.3 ± 1.5 kg CO2 per family. Extrapolating this data, the total emissions from biomass (e.g., fuelwood, crop residues, animal dung, and charcoal) for household cooking in rural areas of India are estimated to be around 0.6 ± 0.4 teragrams (Tg) of CO2 per day. The integration of dual BME688 sensors, leveraging the standard Bosch Software Environmental Cluster library and temperature cycling, achieves an impressive 95% accuracy in fingerprinting emissions from different fuel types. This capability enables the creation of a comprehensive database, where each CO2 emission data point is meticulously linked to the original biomass source. This level of real-time detail, previously unattainable, greatly enhances our ability for emission quantification and offers broad applicability for mitigation efforts.
- 17 July 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (30) , 15730-15740
Open AccessTagging Emissions from Indoor Biomass Combustion with a Cost-Effective Sensor Array: From Design to Field Deployment in Rural Indian Households
In this study, we introduce an innovative method for monitoring emissions from indoor biomass combustion, a prevalent practice in rural households in the Indo-Gangetic Plains. Our approach utilizes a portable and cost-efficient sensor array with advanced data handling, employing commercially available sensors to measure CO2, CO, NO2, SO2, PMs, VOC, NOx, cookstove and ambient temperature, relative humidity, and pressure. We developed hardware and software to gather and process sensor data and control the temperature cycle using the BME688 sensors. The field deployments reveal that CO2 emission from a cooking event is ∼2.3 ± 1.5 kg CO2 per family. Extrapolating this data, the total emissions from biomass (e.g., fuelwood, crop residues, animal dung, and charcoal) for household cooking in rural areas of India are estimated to be around 0.6 ± 0.4 teragrams (Tg) of CO2 per day. The integration of dual BME688 sensors, leveraging the standard Bosch Software Environmental Cluster library and temperature cycling, achieves an impressive 95% accuracy in fingerprinting emissions from different fuel types. This capability enables the creation of a comprehensive database, where each CO2 emission data point is meticulously linked to the original biomass source. This level of real-time detail, previously unattainable, greatly enhances our ability for emission quantification and offers broad applicability for mitigation efforts.
- Open Access
- 1 January 2024
- Published by AMA Service GmbH
- p. 127-132
P19 - Validierung von Gassensoren für die Prüfung von Luftreiniger
- 1 January 2024
- Published by AMA Service GmbH
- p. 127-132
Open AccessP19 - Validierung von Gassensoren für die Prüfung von Luftreiniger
- Open Access
- 7 July 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (7) , 1123
Comparison of Transfer Learning and Established Calibration Transfer Methods for Metal Oxide Semiconductor Gas Sensors
Although metal oxide semiconductors are a promising candidate for accurate indoor air quality assessments, multiple drawbacks of the gas sensors prevent their widespread use. Examples include poor selectivity, instability over time, and sensor poisoning. Complex calibration methods and advanced operation modes can solve some of those drawbacks. However, this leads to long calibration times, which are unsuitable for mass production. In recent years, multiple attempts to solve calibration transfer have been made with the help of direct standardization, orthogonal signal correction, and many more methods. Besides those, a new promising approach is transfer learning from deep learning. This article will compare different calibration transfer methods, including direct standardization, piecewise direct standardization, transfer learning for deep learning models, and global model building. The machine learning methods to calibrate the initial models for calibration transfer are feature extraction, selection, and regression (established methods) and a custom convolutional neural network TCOCNN. It is shown that transfer learning can outperform the other calibration transfer methods regarding the root mean squared error, especially if the initial model is built with multiple sensors. It was possible to reduce the number of calibration samples by up to 99.3% (from 10 days to approximately 2 h) and still achieve an RMSE for acetone of around 18 ppb (15 ppb with extended individual calibration) if six different sensors were used for building the initial model. Furthermore, it was shown that the other calibration transfer methods (direct standardization and piecewise direct standardization) also work reasonably well for both machine learning approaches, primarily when multiple sensors are used for the initial model.
- 7 July 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (7) , 1123
Open AccessComparison of Transfer Learning and Established Calibration Transfer Methods for Metal Oxide Semiconductor Gas Sensors
Although metal oxide semiconductors are a promising candidate for accurate indoor air quality assessments, multiple drawbacks of the gas sensors prevent their widespread use. Examples include poor selectivity, instability over time, and sensor poisoning. Complex calibration methods and advanced operation modes can solve some of those drawbacks. However, this leads to long calibration times, which are unsuitable for mass production. In recent years, multiple attempts to solve calibration transfer have been made with the help of direct standardization, orthogonal signal correction, and many more methods. Besides those, a new promising approach is transfer learning from deep learning. This article will compare different calibration transfer methods, including direct standardization, piecewise direct standardization, transfer learning for deep learning models, and global model building. The machine learning methods to calibrate the initial models for calibration transfer are feature extraction, selection, and regression (established methods) and a custom convolutional neural network TCOCNN. It is shown that transfer learning can outperform the other calibration transfer methods regarding the root mean squared error, especially if the initial model is built with multiple sensors. It was possible to reduce the number of calibration samples by up to 99.3% (from 10 days to approximately 2 h) and still achieve an RMSE for acetone of around 18 ppb (15 ppb with extended individual calibration) if six different sensors were used for building the initial model. Furthermore, it was shown that the other calibration transfer methods (direct standardization and piecewise direct standardization) also work reasonably well for both machine learning approaches, primarily when multiple sensors are used for the initial model.
- Open Access
- 15 June 2023
- Published by MDPI AG in Preprints.org
Comparison of Transfer Learning and Established Calibration Transfer Methods for Metal Oxide Semiconductor Gas Sensors
With metal oxide semiconductors being a promising candidate for accurate indoor air quality assessments, multiple drawbacks of the gas sensors prevent their widespread use. Examples include poor selectivity, instability over time, and sensor poisoning. Complex calibration methods and advanced operation modes can solve some of those drawbacks. However, this leads to long calibration times, which are unsuitable for mass production. In recent years, multiple attempts to solve calibration transfer have been made with the help of direct standardization, orthogonal signal correction, and many more methods. Besides those, a new promising approach is transfer learning from deep learning. This article will compare different calibration transfer methods, including direct standardization, piecewise direct standardization, transfer learning for deep learning models, and global model building. The machine learning methods to calibrate the initial models for calibration transfer are feature extraction, selection, and regression (established methods) and a custom convolutional neural network TCOCNN. It is shown that transfer learning can outperform the other calibration transfer methods regarding the root mean squared error, especially if the initial model is built with multiple sensors. It was possible to reduce the number of calibration samples by up to 99.3 % (from 10 days to approximately 2 hours) and still achieve an RMSE for acetone of around 18 ppb (15 ppb with extended individual calibration) if six different sensors were used for building the initial model. Furthermore, it was shown that the other calibration transfer methods (direct standardization and piecewise direct standardization) also work reasonably well for both machine learning approaches, primarily when multiple sensors are used for the initial model.
- 15 June 2023
- Published by MDPI AG in Preprints.org
Open AccessComparison of Transfer Learning and Established Calibration Transfer Methods for Metal Oxide Semiconductor Gas Sensors
With metal oxide semiconductors being a promising candidate for accurate indoor air quality assessments, multiple drawbacks of the gas sensors prevent their widespread use. Examples include poor selectivity, instability over time, and sensor poisoning. Complex calibration methods and advanced operation modes can solve some of those drawbacks. However, this leads to long calibration times, which are unsuitable for mass production. In recent years, multiple attempts to solve calibration transfer have been made with the help of direct standardization, orthogonal signal correction, and many more methods. Besides those, a new promising approach is transfer learning from deep learning. This article will compare different calibration transfer methods, including direct standardization, piecewise direct standardization, transfer learning for deep learning models, and global model building. The machine learning methods to calibrate the initial models for calibration transfer are feature extraction, selection, and regression (established methods) and a custom convolutional neural network TCOCNN. It is shown that transfer learning can outperform the other calibration transfer methods regarding the root mean squared error, especially if the initial model is built with multiple sensors. It was possible to reduce the number of calibration samples by up to 99.3 % (from 10 days to approximately 2 hours) and still achieve an RMSE for acetone of around 18 ppb (15 ppb with extended individual calibration) if six different sensors were used for building the initial model. Furthermore, it was shown that the other calibration transfer methods (direct standardization and piecewise direct standardization) also work reasonably well for both machine learning approaches, primarily when multiple sensors are used for the initial model.
- Open Access
- 2 October 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (10) , 1614
Deep Learning Based Calibration Time Reduction for MOS Gas Sensors with Transfer Learning
In this study, methods from the field of deep learning are used to calibrate a metal oxide semiconductor (MOS) gas sensor in a complex environment in order to be able to predict a specific gas concentration. Specifically, we want to tackle the problem of long calibration times and the problem of transferring calibrations between sensors, which is a severe challenge for the widespread use of MOS gas sensor systems. Therefore, this contribution aims to significantly diminish those problems by applying transfer learning from the field of deep learning. Within the field of deep learning, transfer learning has become more and more popular. Nowadays, building a model (calibrating a sensor) based on pre-trained models instead of training from scratch is a standard routine. This allows the model to train with inherent information and reach a suitable solution much faster or more accurately. For predicting the gas concentration with a MOS gas sensor operated dynamically using temperature cycling, the calibration time can be significantly reduced for all nine target gases at the ppb level (seven volatile organic compounds plus carbon monoxide and hydrogen). It was possible to reduce the calibration time by up to 93% and still obtain root-mean-squared error (RMSE) values only double the best achieved RMSEs. In order to obtain the best possible transferability, different transfer methods and the influence of different transfer data sets for training were investigated. Finally, transfer learning based on neural networks is compared to a global calibration model based on feature extraction, selection, and regression to place the results in the context of already existing work.
- 2 October 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (10) , 1614
Open AccessDeep Learning Based Calibration Time Reduction for MOS Gas Sensors with Transfer Learning
In this study, methods from the field of deep learning are used to calibrate a metal oxide semiconductor (MOS) gas sensor in a complex environment in order to be able to predict a specific gas concentration. Specifically, we want to tackle the problem of long calibration times and the problem of transferring calibrations between sensors, which is a severe challenge for the widespread use of MOS gas sensor systems. Therefore, this contribution aims to significantly diminish those problems by applying transfer learning from the field of deep learning. Within the field of deep learning, transfer learning has become more and more popular. Nowadays, building a model (calibrating a sensor) based on pre-trained models instead of training from scratch is a standard routine. This allows the model to train with inherent information and reach a suitable solution much faster or more accurately. For predicting the gas concentration with a MOS gas sensor operated dynamically using temperature cycling, the calibration time can be significantly reduced for all nine target gases at the ppb level (seven volatile organic compounds plus carbon monoxide and hydrogen). It was possible to reduce the calibration time by up to 93% and still obtain root-mean-squared error (RMSE) values only double the best achieved RMSEs. In order to obtain the best possible transferability, different transfer methods and the influence of different transfer data sets for training were investigated. Finally, transfer learning based on neural networks is compared to a global calibration model based on feature extraction, selection, and regression to place the results in the context of already existing work.
- Open Access
- 1 January 2022
- Published by AMA Service GmbH
- p. 141-144
P23 - Monitoring Indoor Air Quality with low-cost Sensor Systems
- 1 January 2022
- Published by AMA Service GmbH
- p. 141-144
Open AccessP23 - Monitoring Indoor Air Quality with low-cost Sensor Systems
- Open Access
- 10 November 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (11) , 1487
High-Performance VOC Quantification for IAQ Monitoring Using Advanced Sensor Systems and Deep Learning
With air quality being one target in the sustainable development goals set by the United Nations, accurate monitoring also of indoor air quality is more important than ever. Chemiresistive gas sensors are an inexpensive and promising solution for the monitoring of volatile organic compounds, which are of high concern indoors. To fully exploit the potential of these sensors, advanced operating modes, calibration, and data evaluation methods are required. This contribution outlines a systematic approach based on dynamic operation (temperature-cycled operation), randomized calibration (Latin hypercube sampling), and the use of advances in deep neural networks originally developed for natural language processing and computer vision, applying this approach to volatile organic compound measurements for indoor air quality monitoring. This paper discusses the pros and cons of deep neural networks for volatile organic compound monitoring in a laboratory environment by comparing the quantification accuracy of state-of-the-art data evaluation methods with a 10-layer deep convolutional neural network (TCOCNN). The overall performance of both methods was compared for complex gas mixtures with several volatile organic compounds, as well as interfering gases and changing ambient humidity in a comprehensive lab evaluation. Furthermore, both were tested under realistic conditions in the field with additional release tests of volatile organic compounds. The results obtained during field testing were compared with analytical measurements, namely the gold standard gas chromatography mass spectrometry analysis based on Tenax sampling, as well as two mobile systems, a gas chromatograph with photo-ionization detection for volatile organic compound monitoring and a gas chromatograph with a reducing compound photometer for the monitoring of hydrogen. The results showed that the TCOCNN outperforms state-of-the-art data evaluation methods, for example for critical pollutants such as formaldehyde, achieving an uncertainty of around 11 ppb even in complex mixtures, and offers a more robust volatile organic compound quantification in a laboratory environment, as well as in real ambient air for most targets.
- 10 November 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (11) , 1487
Open AccessHigh-Performance VOC Quantification for IAQ Monitoring Using Advanced Sensor Systems and Deep Learning
With air quality being one target in the sustainable development goals set by the United Nations, accurate monitoring also of indoor air quality is more important than ever. Chemiresistive gas sensors are an inexpensive and promising solution for the monitoring of volatile organic compounds, which are of high concern indoors. To fully exploit the potential of these sensors, advanced operating modes, calibration, and data evaluation methods are required. This contribution outlines a systematic approach based on dynamic operation (temperature-cycled operation), randomized calibration (Latin hypercube sampling), and the use of advances in deep neural networks originally developed for natural language processing and computer vision, applying this approach to volatile organic compound measurements for indoor air quality monitoring. This paper discusses the pros and cons of deep neural networks for volatile organic compound monitoring in a laboratory environment by comparing the quantification accuracy of state-of-the-art data evaluation methods with a 10-layer deep convolutional neural network (TCOCNN). The overall performance of both methods was compared for complex gas mixtures with several volatile organic compounds, as well as interfering gases and changing ambient humidity in a comprehensive lab evaluation. Furthermore, both were tested under realistic conditions in the field with additional release tests of volatile organic compounds. The results obtained during field testing were compared with analytical measurements, namely the gold standard gas chromatography mass spectrometry analysis based on Tenax sampling, as well as two mobile systems, a gas chromatograph with photo-ionization detection for volatile organic compound monitoring and a gas chromatograph with a reducing compound photometer for the monitoring of hydrogen. The results showed that the TCOCNN outperforms state-of-the-art data evaluation methods, for example for critical pollutants such as formaldehyde, achieving an uncertainty of around 11 ppb even in complex mixtures, and offers a more robust volatile organic compound quantification in a laboratory environment, as well as in real ambient air for most targets.
- 24 August 2021
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 88 (s1) , s89-s94
Bewertung der Innenraumluftqualität über VOC-Messungen mit Halbleitergassensoren - Kalibrierung, Feldtest, Validierung
Zusammenfassung In jüngster Vergangenheit sind immer mehr Halbleitergassensoren im Bereich Innenraumluftqualität auf den Markt gekommen. Diese messen die Gesamtbelastung an flüchtigen organischen Komponenten (engl.: volatile organic compounds, kurz: VOCs) oder einen relativen Innenraumluftqualitätsindex. Mit einer optimierten Betriebsweise und Kalibrierung können die Sensoren in ihrer Selektivität und Sensitivität gesteigert werden, was für die Bewertung der Innenraumluftqualität wichtig wäre. Die Möglichkeiten und Grenzen werden in dieser Studie vorgestellt. Für diese Zielanwendung müssen die Sensoren zuerst kalibriert werden. Auf Basis der Daten einer umfangreichen Laborkalibrierung kommen verschiedene Methoden des maschinellen Lernens für die Datenauswertung zum Einsatz. Diese Studie beinhaltet die Untersuchung der Eignung eines kommerziell verfügbaren Multisensors (SGP30, Sensirion) im temperaturzyklischen Betrieb für die selektive Messung von VOCs im Innenraum. Nach der Laborkalibrierung wurde der Sensor vier Wochen im Feld betrieben. Über Freisetzungstests durch Verdampfung von Flüssigkeiten wurden die Modelle auf Funktionalität geprüft. Außerdem wurden mit den analytischen Messsystemen TD-GC-MS (ThermodesorptionGaschromatographie-Massenspektrometer mit Tenax Probennahme) und einem mobilen GC mit Photo-IonisationsDetektor, PID (X-pid 9500, Dräger) regelmäßig Vergleichsmessungen durchgeführt. Mithilfe von Rekalibrierungen im Labor und anschließenden Feldtests wurde außerdem die Stabilität der Modelle untersucht. Diese Studie zeigt, dass mit dem SGP30 eine Vor-Ort-Messung der Gesamt-VOC-Belastung in Innenräumen mit hoher zeitlicher Auflösung möglich ist und auch eine selektive Messung bestimmter Stoffe und Stoffgruppen realisierbar ist.
- 24 August 2021
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 88 (s1) , s89-s94
Bewertung der Innenraumluftqualität über VOC-Messungen mit Halbleitergassensoren - Kalibrierung, Feldtest, Validierung
Zusammenfassung In jüngster Vergangenheit sind immer mehr Halbleitergassensoren im Bereich Innenraumluftqualität auf den Markt gekommen. Diese messen die Gesamtbelastung an flüchtigen organischen Komponenten (engl.: volatile organic compounds, kurz: VOCs) oder einen relativen Innenraumluftqualitätsindex. Mit einer optimierten Betriebsweise und Kalibrierung können die Sensoren in ihrer Selektivität und Sensitivität gesteigert werden, was für die Bewertung der Innenraumluftqualität wichtig wäre. Die Möglichkeiten und Grenzen werden in dieser Studie vorgestellt. Für diese Zielanwendung müssen die Sensoren zuerst kalibriert werden. Auf Basis der Daten einer umfangreichen Laborkalibrierung kommen verschiedene Methoden des maschinellen Lernens für die Datenauswertung zum Einsatz. Diese Studie beinhaltet die Untersuchung der Eignung eines kommerziell verfügbaren Multisensors (SGP30, Sensirion) im temperaturzyklischen Betrieb für die selektive Messung von VOCs im Innenraum. Nach der Laborkalibrierung wurde der Sensor vier Wochen im Feld betrieben. Über Freisetzungstests durch Verdampfung von Flüssigkeiten wurden die Modelle auf Funktionalität geprüft. Außerdem wurden mit den analytischen Messsystemen TD-GC-MS (ThermodesorptionGaschromatographie-Massenspektrometer mit Tenax Probennahme) und einem mobilen GC mit Photo-IonisationsDetektor, PID (X-pid 9500, Dräger) regelmäßig Vergleichsmessungen durchgeführt. Mithilfe von Rekalibrierungen im Labor und anschließenden Feldtests wurde außerdem die Stabilität der Modelle untersucht. Diese Studie zeigt, dass mit dem SGP30 eine Vor-Ort-Messung der Gesamt-VOC-Belastung in Innenräumen mit hoher zeitlicher Auflösung möglich ist und auch eine selektive Messung bestimmter Stoffe und Stoffgruppen realisierbar ist.
- 30 May 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-01 (56) , 1488
Field Tests of Smart Mos Gas Sensor Systems for Selective Quantification of VOCs
Metal oxide semiconductor (MOS) gas sensors are excellent candidates for real-time indoor air quality monitoring due to their outstanding sensitivity for a broad spectrum of gases and low price. Selective detection and quantification in complex environments represent the ultimate challenge since some gases may be harmful at very low concentration while others are tolerable at much higher levels. To achieve this selective quantification with sensor systems based on physical (several sensitive layers) or virtual (temperature cycling) multisensors complex calibration and application of machine learning algorithms is needed [1]. These models are normally trained in complex gas mixing systems [2] and testing for generalizability is often omitted. In this work we show the performance of lab-calibrated smart sensors in field measurements of volatile organic compounds (VOCs) using release tests accompanied by reference measurements wherever possible. For this multilayer SGP30 sensors (Sensirion AG, Switzerland, [3], 4 sensors in total were measured, presented results are based on one of the sensors) in temperature cycled operation (TCO) were calibrated with randomized gas mixtures [4] containing hydrogen (H2, 400-4000 ppb), carbon monoxide (CO, 150-2000 ppb), ethanol (4-1000 ppb), toluene (4-1000 ppb), formaldehyde (1-400 ppb) and acetone (17-1000 ppb). The temperature cycle with a duration of 120 s comprises 10 phases at high temperature (400 °C, 5 s) each followed by a low temperature phase (100 °C, 125 °C, ..., 375 °C, 7 s). Features are extracted by computing the slope of 120 equidistant ranges, yielding 120 features per layer and 480 per sensor. For each sensor, a feature selection by recursive feature elimination is performed and PLSR (partial least squares regression) models predicting the concentration of the individual gases and the TVOC concentration (total volatile organic compounds, for this measurement: sum of gases except H2 and CO) both in ppb and µg/m³ are trained. The obtained RMSE values from a 10-fold cross-validation can be found in Tab. 1. The sensors are then brought to the field – a regular office at our lab – where they operated for 2-3 weeks followed by a repetition of the lab measurement followed by another 2-3 weeks of operation in the field followed by a final lab measurement. In the field several VOC release tests were conducted: toluene, acetone, ethanol, isopropanol, xylene, and limonene were released by evaporating liquid in the middle of the room. H2 is released via a controlled mass flow from a gas cylinder and CO generated by a tealight candle. Reference measurements were performed via thermal desorption (Tenax TA and Graphitized Carbon Universal, Markes International GmbH, Germany) with GC-MS analysis (for toluene, xylene, acetone), a portable GC-PID device (Draeger X-PID, Drägerwerk AG & Co. KGaA, Germany; acetone, isopropanol, toluene, xylene) and via a Peak Performer 1 RCP (Peak Laboratories, LLC, USA) chromatograph for H2. For the lab-calibrated substances the results show that selective signals can be obtained from the smart sensor system: only the output signal corresponding to the released component increases significantly during the test and recovers over hours through self-ventilation and decomposition inside the room. The predicted concentrations are a little below the theoretical maximum concentration determined from the volumes of the room and liquid released. Where reference data are available, we sometimes observe an offset between sensor and reference, especially with increasing time from last calibration, but relative values (signal height and shape over time) show an excellent match in all cases. The TVOC concentrations quantified in ppb and µg/m³ also match the released amount of gas. As an example, Fig. 1 shows the toluene sensor signal and obtained reference values and Fig. 2 all sensor signals during a release of 0.164 ml toluene and 0.114 ml acetone (corresponding to 600 ppb in the room, if evenly distributed, two release tests are shown). For substances not covered by the lab calibration different types of behaviors were observed. Xylene release affects the toluene quantification signal, indicating that identification of a chemical group was learned by the model. The sensitivity is slightly lower than for toluene. Releasing isopropanol does not affect any sensor signal, thus the ethanol signal does not represent the quantification of alcohols as a chemical group. Limonene which has no representative from its chemical group inside the calibration does not affect any signal. During the first field test period, we observed a drift of the predicted concentrations, especially for toluene, reaching negative values after some time. By extending the training with the repeated calibration after the field test this drift was corrected for all data, i.e. both the first and second field test period. This means that the model learns to compensate sensor drift and/or selects more stable features for the quantification if drift is included in the calibration. Data evaluation is ongoing, among others more types of machine learning algorithms will be tested and optimization of the calibration (less data samples for calibration and recalibration, transferability between sensors) will be studied. [1] M. Leidinger et al.: Selective detection of hazardous VOCs for indoor air quality applications using a virtual gas sensor array, J. Sens. Sens. Syst., 3 (2014), pp. 253-263, doi:10.5194/jsss-3-253-2014. [2] N. Helwig et al.: Gas mixing apparatus for automated gas sensor characterization, Meas. Sci. Technol. 25 (2014) 055903, doi:10.1088/0957-0233/25/5/055903 [3] D. Rüffner, F. Hoehne, J. Bühler, New Digital Metal-Oxide (MOx) Sensor Platform, Sensors, 18/4 (2018), 1052, doi:10.3390/s18041052. [4] T. Baur et al.: Random gas mixtures for efficient gas sensor calibration, J. Sens. Sens. Syst. (2020) 9, 411-424, doi:10.5194/jsss-9-411-2020. Figure 1
- 30 May 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-01 (56) , 1488
Field Tests of Smart Mos Gas Sensor Systems for Selective Quantification of VOCs
Metal oxide semiconductor (MOS) gas sensors are excellent candidates for real-time indoor air quality monitoring due to their outstanding sensitivity for a broad spectrum of gases and low price. Selective detection and quantification in complex environments represent the ultimate challenge since some gases may be harmful at very low concentration while others are tolerable at much higher levels. To achieve this selective quantification with sensor systems based on physical (several sensitive layers) or virtual (temperature cycling) multisensors complex calibration and application of machine learning algorithms is needed [1]. These models are normally trained in complex gas mixing systems [2] and testing for generalizability is often omitted. In this work we show the performance of lab-calibrated smart sensors in field measurements of volatile organic compounds (VOCs) using release tests accompanied by reference measurements wherever possible. For this multilayer SGP30 sensors (Sensirion AG, Switzerland, [3], 4 sensors in total were measured, presented results are based on one of the sensors) in temperature cycled operation (TCO) were calibrated with randomized gas mixtures [4] containing hydrogen (H2, 400-4000 ppb), carbon monoxide (CO, 150-2000 ppb), ethanol (4-1000 ppb), toluene (4-1000 ppb), formaldehyde (1-400 ppb) and acetone (17-1000 ppb). The temperature cycle with a duration of 120 s comprises 10 phases at high temperature (400 °C, 5 s) each followed by a low temperature phase (100 °C, 125 °C, ..., 375 °C, 7 s). Features are extracted by computing the slope of 120 equidistant ranges, yielding 120 features per layer and 480 per sensor. For each sensor, a feature selection by recursive feature elimination is performed and PLSR (partial least squares regression) models predicting the concentration of the individual gases and the TVOC concentration (total volatile organic compounds, for this measurement: sum of gases except H2 and CO) both in ppb and µg/m³ are trained. The obtained RMSE values from a 10-fold cross-validation can be found in Tab. 1. The sensors are then brought to the field – a regular office at our lab – where they operated for 2-3 weeks followed by a repetition of the lab measurement followed by another 2-3 weeks of operation in the field followed by a final lab measurement. In the field several VOC release tests were conducted: toluene, acetone, ethanol, isopropanol, xylene, and limonene were released by evaporating liquid in the middle of the room. H2 is released via a controlled mass flow from a gas cylinder and CO generated by a tealight candle. Reference measurements were performed via thermal desorption (Tenax TA and Graphitized Carbon Universal, Markes International GmbH, Germany) with GC-MS analysis (for toluene, xylene, acetone), a portable GC-PID device (Draeger X-PID, Drägerwerk AG & Co. KGaA, Germany; acetone, isopropanol, toluene, xylene) and via a Peak Performer 1 RCP (Peak Laboratories, LLC, USA) chromatograph for H2. For the lab-calibrated substances the results show that selective signals can be obtained from the smart sensor system: only the output signal corresponding to the released component increases significantly during the test and recovers over hours through self-ventilation and decomposition inside the room. The predicted concentrations are a little below the theoretical maximum concentration determined from the volumes of the room and liquid released. Where reference data are available, we sometimes observe an offset between sensor and reference, especially with increasing time from last calibration, but relative values (signal height and shape over time) show an excellent match in all cases. The TVOC concentrations quantified in ppb and µg/m³ also match the released amount of gas. As an example, Fig. 1 shows the toluene sensor signal and obtained reference values and Fig. 2 all sensor signals during a release of 0.164 ml toluene and 0.114 ml acetone (corresponding to 600 ppb in the room, if evenly distributed, two release tests are shown). For substances not covered by the lab calibration different types of behaviors were observed. Xylene release affects the toluene quantification signal, indicating that identification of a chemical group was learned by the model. The sensitivity is slightly lower than for toluene. Releasing isopropanol does not affect any sensor signal, thus the ethanol signal does not represent the quantification of alcohols as a chemical group. Limonene which has no representative from its chemical group inside the calibration does not affect any signal. During the first field test period, we observed a drift of the predicted concentrations, especially for toluene, reaching negative values after some time. By extending the training with the repeated calibration after the field test this drift was corrected for all data, i.e. both the first and second field test period. This means that the model learns to compensate sensor drift and/or selects more stable features for the quantification if drift is included in the calibration. Data evaluation is ongoing, among others more types of machine learning algorithms will be tested and optimization of the calibration (less data samples for calibration and recalibration, transferability between sensors) will be studied. [1] M. Leidinger et al.: Selective detection of hazardous VOCs for indoor air quality applications using a virtual gas sensor array, J. Sens. Sens. Syst., 3 (2014), pp. 253-263, doi:10.5194/jsss-3-253-2014. [2] N. Helwig et al.: Gas mixing apparatus for automated gas sensor characterization, Meas. Sci. Technol. 25 (2014) 055903, doi:10.1088/0957-0233/25/5/055903 [3] D. Rüffner, F. Hoehne, J. Bühler, New Digital Metal-Oxide (MOx) Sensor Platform, Sensors, 18/4 (2018), 1052, doi:10.3390/s18041052. [4] T. Baur et al.: Random gas mixtures for efficient gas sensor calibration, J. Sens. Sens. Syst. (2020) 9, 411-424, doi:10.5194/jsss-9-411-2020. Figure 1
- Open Access
- 19 May 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (5) , 647
Field Study of Metal Oxide Semiconductor Gas Sensors in Temperature Cycled Operation for Selective VOC Monitoring in Indoor Air
More and more metal oxide semiconductor (MOS) gas sensors with digital interfaces are entering the market for indoor air quality (IAQ) monitoring. These sensors are intended to measure volatile organic compounds (VOCs) in indoor air, an important air quality factor. However, their standard operating mode often does not make full use of their true capabilities. More sophisticated operation modes, extensive calibration and advanced data evaluation can significantly improve VOC measurements and, furthermore, achieve selective measurements of single gases or at least types of VOCs. This study provides an overview of the potential and limits of MOS gas sensors for IAQ monitoring using temperature cycled operation (TCO), calibration with randomized exposure and data-based models trained with advanced machine learning. After lab calibration, a commercial digital gas sensor with four different gas-sensitive layers was tested in the field over several weeks. In addition to monitoring normal ambient air, release tests were performed with compounds that were included in the lab calibration, but also with additional VOCs. The tests were accompanied by different analytical systems (GC-MS with Tenax sampling, mobile GC-PID and GC-RCP). The results show quantitative agreement between analytical systems and the MOS gas sensor system. The study shows that MOS sensors are highly suitable for determining the overall VOC concentrations with high temporal resolution and, with some restrictions, also for selective measurements of individual components.
- 19 May 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (5) , 647
Open AccessField Study of Metal Oxide Semiconductor Gas Sensors in Temperature Cycled Operation for Selective VOC Monitoring in Indoor Air
More and more metal oxide semiconductor (MOS) gas sensors with digital interfaces are entering the market for indoor air quality (IAQ) monitoring. These sensors are intended to measure volatile organic compounds (VOCs) in indoor air, an important air quality factor. However, their standard operating mode often does not make full use of their true capabilities. More sophisticated operation modes, extensive calibration and advanced data evaluation can significantly improve VOC measurements and, furthermore, achieve selective measurements of single gases or at least types of VOCs. This study provides an overview of the potential and limits of MOS gas sensors for IAQ monitoring using temperature cycled operation (TCO), calibration with randomized exposure and data-based models trained with advanced machine learning. After lab calibration, a commercial digital gas sensor with four different gas-sensitive layers was tested in the field over several weeks. In addition to monitoring normal ambient air, release tests were performed with compounds that were included in the lab calibration, but also with additional VOCs. The tests were accompanied by different analytical systems (GC-MS with Tenax sampling, mobile GC-PID and GC-RCP). The results show quantitative agreement between analytical systems and the MOS gas sensor system. The study shows that MOS sensors are highly suitable for determining the overall VOC concentrations with high temporal resolution and, with some restrictions, also for selective measurements of individual components.