Stephanie Maitz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stephanie Maitz has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Clemens Kittinger
Institute of Hygiene, Microbiology and Environmental Medicine, Medical University Graz, Graz, Austria
3 shared publications - Daniela Dreisiebner
Diagnostic & Research Institute for Hygiene, Microbiology and Environmental Medicine, Medical University of Graz, Graz, Austria
1 shared publication - Daniela Toplitsch
D&R-Institute of Hygiene, Microbiology and Environmental Medicine, Medical University of Graz, 8010 Graz, Austria
1 shared publication - Eva Zarschenas
Diagnostic & Research Institute for Hygiene, Microbiology and Environmental Medicine, Medical University of Graz, Graz, Austria
1 shared publication - Franz Mascher
Diagnostic & Research Institute of Hygiene, Microbiology and Environmental Medicine, Medical University of Graz, 8010 Graz, Austria
1 shared publication - Paul Jakob Schmid
Diagnostic and Research Institute of Hygiene, Microbiology and Environmental Medicine, Diagnostic and Research Center for Molecular Biomedicine, Medical University of Graz , Graz , Austria
1 shared publication
Latest Publications
- Open Access
- 15 April 2026
- Published by Springer Nature in BMC Microbiology
- Vol. 26 (1)
Assessing non-porous antimicrobial surfaces against bacteria, phages and fungi: a comparative study under varied normative conditions using glass as a benchmark for microbial persistence
The survival of pathogenic microorganisms on surfaces is contingent on environmental factors, including humidity and temperature. In order to analyze the s
- 15 April 2026
- Published by Springer Nature in BMC Microbiology
- Vol. 26 (1)
Open AccessAssessing non-porous antimicrobial surfaces against bacteria, phages and fungi: a comparative study under varied normative conditions using glass as a benchmark for microbial persistence
The survival of pathogenic microorganisms on surfaces is contingent on environmental factors, including humidity and temperature. In order to analyze the s
- Open Access
- 4 March 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (5) , 2996
Modelling and Determination of Parameters Influencing the Transfer of Microorganisms from Food Contact Materials
The transfer of microorganisms on packaging materials to a contact surface has only been investigated in the context of laboratory-produced spiked packaging products and agar surfaces in small quantities (0.03–0.10%) so far. Correspondingly, this study focused on the localization of microorganisms on/in industrially produced packaging materials and on the establishment of an experimental laboratory set-up to determine and quantify the parameters influencing the microbial transport from surfaces and different layers of packaging materials to contact agar media. We established a simple model to determine the transfer of microorganisms from packaging materials to microbiological agar plates. In order to clarify the transfer of microorganisms within the material, the samples were split horizontally in their z-dimension, and so produced layers (inner layers) were investigated for their microbial transfer. The parameters incubation time, applied weight and bacterial load for the samples were investigated in more detail in the outer layers (front/back) and the inner layers. No significant difference in the microbial transfer was observed between the outer and inner layers of all samples. We indicate a time-dependent transfer to the media and an independence of the transfer from the applied weight. Moreover, the number of transferred microorganisms is not dependent on the bacterial load of the samples.
- 4 March 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (5) , 2996
Open AccessModelling and Determination of Parameters Influencing the Transfer of Microorganisms from Food Contact Materials
The transfer of microorganisms on packaging materials to a contact surface has only been investigated in the context of laboratory-produced spiked packaging products and agar surfaces in small quantities (0.03–0.10%) so far. Correspondingly, this study focused on the localization of microorganisms on/in industrially produced packaging materials and on the establishment of an experimental laboratory set-up to determine and quantify the parameters influencing the microbial transport from surfaces and different layers of packaging materials to contact agar media. We established a simple model to determine the transfer of microorganisms from packaging materials to microbiological agar plates. In order to clarify the transfer of microorganisms within the material, the samples were split horizontally in their z-dimension, and so produced layers (inner layers) were investigated for their microbial transfer. The parameters incubation time, applied weight and bacterial load for the samples were investigated in more detail in the outer layers (front/back) and the inner layers. No significant difference in the microbial transfer was observed between the outer and inner layers of all samples. We indicate a time-dependent transfer to the media and an independence of the transfer from the applied weight. Moreover, the number of transferred microorganisms is not dependent on the bacterial load of the samples.
- Open Access
- 19 May 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (10) , 5436
Comparison of Updated Methods for Legionella Detection in Environmental Water Samples
The difficulty of cultivation of Legionella spp. from water samples remains a strenuous task even for experienced laboratories. The long incubation periods for Legionellae make isolation difficult. In addition, the water samples themselves are often contaminated with accompanying microbial flora, and therefore require complex cultivation methods from diagnostic laboratories. In addition to the recent update of the standard culture method ISO 11731:2017, new strategies such as quantitative PCR (qPCR) are often discussed as alternatives or additions to conventional Legionella culture approaches. In this study, we compared ISO 11731:2017 with qPCR assays targeting Legionella spp., Legionella pneumophila, and Legionella pneumophila serogroup 1. In samples with a high burden of accompanying microbial flora, qPCR shows an excellent negative predictive value for Legionella pneumophila, thus making qPCR an excellent tool for pre-selection of negative samples prior to work-intensive culture methods. This and its low limit of detection make qPCR a diagnostic asset in Legionellosis outbreak investigations, where quick-risk assessments are essential, and are a useful method for monitoring risk sites.
- 19 May 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (10) , 5436
Open AccessComparison of Updated Methods for Legionella Detection in Environmental Water Samples
The difficulty of cultivation of Legionella spp. from water samples remains a strenuous task even for experienced laboratories. The long incubation periods for Legionellae make isolation difficult. In addition, the water samples themselves are often contaminated with accompanying microbial flora, and therefore require complex cultivation methods from diagnostic laboratories. In addition to the recent update of the standard culture method ISO 11731:2017, new strategies such as quantitative PCR (qPCR) are often discussed as alternatives or additions to conventional Legionella culture approaches. In this study, we compared ISO 11731:2017 with qPCR assays targeting Legionella spp., Legionella pneumophila, and Legionella pneumophila serogroup 1. In samples with a high burden of accompanying microbial flora, qPCR shows an excellent negative predictive value for Legionella pneumophila, thus making qPCR an excellent tool for pre-selection of negative samples prior to work-intensive culture methods. This and its low limit of detection make qPCR a diagnostic asset in Legionellosis outbreak investigations, where quick-risk assessments are essential, and are a useful method for monitoring risk sites.