EVEric L. G. Verhoeven

Eric L. G. Verhoeven

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Eric L. G. Verhoeven has a total of 271 co-authors. Here are the top co-authors by number of shared publications:

  • Athanasios Katsargyris

    Department of Vascular and Endovascular Surgery, General Hospital Nuremberg, Paracelsus Medical University Nuremberg, Nuremberg, Germany

    18 shared publications
  • A. Katsargyris

    Department of Vascular and Endovascular Surgery, Paracelsus Medical University, Nuremberg, Germany

    16 shared publications
  • Kyriakos Oikonomou

    Department of Vascular and Endovascular Surgery, Paracelsus Medical University, Nuremberg, Germany; Department of Vascular Surgery, University Medical Centre Regensburg, Regensburg, Germany

    10 shared publications
  • Athanasios Katsargyris

    2nd Department of Vascular Surgery, Laiko General Hospital of Athens, National and Kapodistrian University of Athens Medical School, Athens, Greece

    7 shared publications
  • George Kouvelos

    Department of Vascular Surgery, University Hospital of Larissa, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece

    7 shared publications
  • Clark J. Zeebregts

    Department of Surgery, University Medical Centre Groningen, Groningen, The Netherlands

    6 shared publications

Latest Publications

  • Mid-term Outcomes of Four-Fenestrated Endovascular Aneurysm Repair Without Stenting of the Celiac Artery (The UNCAP Study): Insights From a Multicentric European Experience

    by Pablo Marques de Marino, Mario D’ORia, Athanasios Katsargyris, Sergio Zacà, Melad Abu Jiries, Natasha Hasemaki, Domenico Angiletta, Sandro Lepidi, Eric L Verhoeven

    Objectives: This study analyses the results of endovascular treatment of juxtarenal and suprarenal aortic aneurysms (J/SAAAs) using fenestrated stent-grafts with 4 fenestrations (4×FEVAR) in which the celiac artery (CA) was left unstented. Methods: Retrospective multicentre study of all consecutive patients treated between May 2018 and January 2024 at 4 European aortic centres. Patients undergoing 4×FEVAR for a J/SAAA in which the fenestration for the CA was left unstented were included. The primary outcomes were primary patency of the CA and CA-related endoleaks, reinterventions and target vessel instability. Results: 68 patients (64 males; mean age 73±7 years) were included. Sixty-two (91%) patients were preoperatively planned to leave the CA unstented. In the remaining six (9%) there was a failure to catheterize the vessel or advance the introducer. There was no CA-related endoleak or occlusion in any patient in the completion angiography. During a median follow-up of 27 months (interquartile range 17–54), a CA-related endoleak was detected in one (1.5%) patient that required reintervention and stenting 2 years after the index procedure. Three (4%) patients presented with an asymptomatic occlusion at 6, 12 and 13 months after surgery, which were treated conservatively. Estimated CA-primary patency at 1, 2 and 3 years was 98.4±1.6%, 94.8±2.9% and 94.8±2.9%, respectively. Two (3%) patients underwent a reintervention involving the CA: the patient with the CA-related endoleak and one patient with thoracic stent-graft extension and stenting of the CA due to proximal progression of disease. Estimated freedom from target vessel instability at 1, 2 and 3 years was 98.4±1.6%, 92.2±3.8% and 92.2±3.8%, respectively. Conclusions: Endovascular repair with 4×FEVAR without stenting of the CA appears to be a safe and effective strategy to treat J/SAAA in selected patients with adequate sealing in the visceral aorta. Clinical Impact: This study analyses the outcomes of endovascular treatment of juxtarenal/suprarenal aneurysms (J/SAAA) using fenestrated stent-grafts with 4 fenestrations (4xFEVAR) in which the fenestration for the celiac artery (CA) was left unstented. This approach can decrease the complexity and duration of 4xFEVAR procedures virtually converting them to simpler 3xFEVAR procedures, while adding proximal sealing length and potentially facilitating a proximal extension of the endovascular repair. The outcomes of this multicentre study suggest that this strategy can be a safe and effective option to treat J/SAAA with adequate sealing in the visceral aorta.

  • Penetrating Chest Injury With a Crossbow Arrow

    by Pablo Marques de Marino, Francesco Pollari, Caroline Eckrich, Eric L. Verhoeven, Markus Preclik

  • Open Access

    Transatlantic Delphi Consensus on the Common Iliac Artery Sealing Zone in Endovascular Aorto-Iliac Aneurysm Repair (the DECIDE Study)

    by Maria-Annette Kooijman, Mario D’ORia, Luca Bertoglio, Isabelle Van Herzeele, Ross Milner, Jean-Paul P.M. de Vries, Richte C.L. Schuurmann, Gautam Agarwal, Michele Antonello, Frederico Bastos Goncalves, et al.

    Objective: Knowledge of hostile factors and their influence on long-term seal in the iliac landing zone is limited. Currently endorsed clinical practice guidelines lack structural evidence on how the iliac landing zone should be assessed in the pre-, intra-, and postoperative phases. The goal of this study was to obtain an international, expert-based consensus on the definition of a hostile iliac landing zone, on how to size and plan stent-grafts to optimize sustainable distal seal, and on the postprocedural follow-up protocol. Methods: Delphi consensus methodology was used, involving a panel of international vascular surgeons experienced in endovascular aneurysm repair (EVAR). The first round consisted of open-ended and multiple-choice questions to explore current practices, with subsequent rounds refining statements through a 4-point Likert scale. Consensus was defined as >75% agreement or disagreement, and the analysis included stability testing and strength of consensus. Results: The study engaged 77 international vascular surgeons, reflecting diverse geographic locations and hospital affiliations. Consensus was achieved on critical preoperative planning elements for EVAR, including a clear definition for a hostile iliac landing zone. The importance of computed tomography angiography for postoperative follow-up imaging was emphasized, including evaluating distal seal length and recommending specific timing for follow-up computed tomography scans and intervention strategies for diminishing iliac seal. Conclusions: This international expert-based Delphi consensus establishes a comprehensive set of consensus-driven recommendations focused on the definition and management of hostile iliac landing zones in EVAR. The key recommendation of this study is the definition of a hostile iliac landing zone as short (24 mm), or conical (>10% diameter difference along the landing zone). Although consensus was achieved on several critical aspects, the study also reveals ongoing debates and considerations that warrant further exploration, including how to tackle diminishing seal without a type IB endoleak. Clinical Impact: This Delphi consensus introduces a standardized definition of a hostile iliac landing zone as short (24 mm), or conical (>10% diameter difference), clinicians now have a clearer framework for assessing complex anatomies. This study provides a comprehensive set of consensus-driven recommendations focused on the definition and management of hostile iliac landing zones in EVAR which gives guidance where current guidelines lack specificity, particularly for distal iliac sealing. The study also reveals ongoing debates and considerations that warrant further exploration, including how to tackle diminishing seal without a type IB endoleak.


  • Endovascular Preservation of Segmental Arteries during Treatment of Thoracoabdominal Aortic Aneurysms with Fenestrated/Branched Stent Grafts: Feasibility and Outcomes

    by Ahmed Eleshra, Gustavo S. Oderich, Richard G. McWilliams, Giuseppe Panuccio, Athanasios Katsargyris, Nikolaos Tsilimparis, Emanuel R. Tenorio, Robert K. Fisher, Eric Verhoeven, Tilo Kölbel


  • Open Access

    Three-Dimensional Geometric Analysis of Balloon-Expandable Covered Stents Improves Classification of Complications after Fenestrated Endovascular Aneurysm Repair

    by Claire van der Riet, Richte C. L. Schuurmann, Eric L. G. Verhoeven, Athanasios Katsargyris, Ignace F. J. Tielliu, Timothy Resch, Reinoud P. H. Bokkers, Jean-Paul P. M. de Vries

    In balloon-expandable covered stent (BECS) associated complications after fenestrated endovascular aneurysm repair (FEVAR), geometric analysis may determine the cause of failure and influence reintervention strategies. This study retrospectively classifies BECS-associated complications based on computed tomographic angiography (CTA) applied geometric analysis. BECS-associated complications of FEVAR-patients treated in two large vascular centers between 2012 and 2021 were included. The post-FEVAR CTA scans of complicated Advanta V12 BECSs were analyzed geometrically and complications were classified according to its location in the BECS. BECS fractures were classified according to an existing classification system. In 279 FEVAR-patients, 34 out of the 683 included Advanta V12 BECS (5%) presented with a complication. Two Advanta V12 complications occurred during the FEVAR procedure and 32 occurred during follow-up of which five post-FEVAR CTA scans were missing or not suitable for analysis. In the remaining 27 BECSs complications were classified as (endoleaks (n = 8), stenoses (n = 4), occlusions (n = 6), fractures (n = 3), and a combination of complications (n = 6)). All BECSs associated complications after FEVAR with available follow up CTA scans could be classified. Geometric analysis of BECS failure post-FEVAR can help to plan the reintervention strategy.


  • Open Access

    Mid-Term Results of Fenestrated Endovascular Repair after Prior Open Aortic Reconstruction

    by Pablo Marques de Marino, Melad Abu Jiries, Pavel Tesinsky, Anas Ibraheem, Athanasios Katsargyris, Eric L. Verhoeven

    This study aims to assess the mid-term results of fenestrated endovascular aneurysm repair (FEVAR) for the treatment of proximal aortic pathology after previous open surgical repair (OSR). All patients with a previous history of OSR of an abdominal aortic aneurysm undergoing a FEVAR procedure between October 2010 and November 2021 were included. The endpoints of the study were technical success, mortality, target vessel patency and reinterventions during follow-up. Thirty-five patients (34 male, mean age 72.9 ± 7 years) were included. The median interval from the primary surgery to the FEVAR procedure was 136 months (range 47–261). The indication for treatment was a para-anastomotic aneurysm in 18 (51%) patients and a true aneurysm due to progression of disease in 17 (49%) patients. Technical success was achieved in 33 (94%) patients. There was one (3%) early death due to postoperative bleeding from a renal artery. Estimated survival at 12, 24 and 36 months was 89.1% ± 6%, 84.4% ± 7.3% and 84.4% ± 7.3%, respectively. There was no aneurysm-related mortality. One (3%) target vessel occluded during follow-up and three (9%) patients underwent late reinterventions. In conclusion, FEVAR is a safe and effective alternative for the endovascular treatment of para-anastomotic aneurysms/pseudoaneurysms after OSR showing high technical success, low mortality and morbidity, and good mid-term outcomes.


  • The Impact of the Proctor Assistance for a Safe Learning Curve in the Development of a Complex Aortic Endovascular Program

    by Ryan Gouveia e Melo, Ruy Fernandes e Fernandes, Margarida Salvado, António Duarte, Alice Lopes, Eric Verhoeven, José Fernandes e Fernandes, Luís Mendes Pedro

    Introduction: Initiating an endovascular aortic program for treatment of complex aortic aneurysms with fenestrated and branched grafts (FB-EVAR) is challenging. Using a Proctor is one option for training and development of the team. However, this approach has not been formally analyzed. The aim of this study was to analyze the learning curve and the effect of the Proctor regarding safety and effectiveness in FB-EVAR. Methods: A single-center retrospective cohort study was performed, including all consecutive elective patients submitted to FB-EVAR (including both thoraco-abdominal-TAAA and complex abdominal aortic aneurysms-C-AAA) from 2013 to 2021. Patients were divided into 2 groups, the first operated with the Proctor present and the second without. Primary outcomes were 30-day mortality (safety) and technical and procedure success (efficacy). Secondary outcomes included treatment performance (procedure time, blood loss, contrast, and radiation use), re-interventions, aneurysm shrinking, target vessel patency, 30-day mortality, aneurysm-related mortality, and overall mortality. Results: Overall, 105 patients were included in the study, 35 operated with Proctor and 70 operated without. The first 20 patients were operated always with the Proctor, and the remaining were operated with the Proctor selectively. Mean age was 71.8 (±7.3) years and 95 patients were male (90.5%). Overall, 62 (65%) patients had C-AAA or extent IV TAAAs and 43 (35%) had extensive TAAAs. There were no significant differences regarding 30-day mortality (Log Rank=0.99), technical success (p=0.4), or procedure success (p=0.8). Mean surgical time was longer in the non-Proctor group (p=0.005), as well as significant intra-operative blood loss (p=0.042). Contrast use (p=0.5) and radiation (p=0.53) were non-significantly different between groups. There were no significant differences regarding length of stay (p=0.4), major adverse events (p=0.6), target vessel patency (Log Rank=0.97), early (p=0.7) and late endoleaks (0.7), aneurysm shrinking (p=0.6), re-interventions (p=0.2), and overall mortality (Log Rank=0.87). Conclusion: In our experience, the use of a Proctor to start and accompany our complex endovascular aortic program for FB-EVAR was both safe and effective and may serve as a template by other countries and centers that aim to developing their programs.