Sara Sadeqi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sara Sadeqi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Vijay K. Goel
4 shared publicationsAmanda Murray
3 shared publicationsDeniz U. Erbulut
Engineering Center for Orthopaedic Research Excellence (E-CORE), Departments of Bioengineering and Orthopaedic Surgery, Colleges of Engineering and Medicine, University of Toledo, Toledo, OH 43606, USA
2 shared publications- Deniz Ufuk Erbulut
Metro North Hospital and Health Service
2 shared publications Grant E. Norte
Cognition, Neuroplasticity, & Sarcopenia (CNS) Laboratory, Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL 32816, USA
2 shared publications- Vijay Kumar Goel
Engineering Center for Orthopedic Research Excellence (E-CORE), Departments of Bioengineering and Orthopaedic Surgery, University of Toledo, Toledo, OH, USA
2 shared publications
Latest Publications
- Open Access
Soft Tissue Mechanics in Hip Distraction after Total Knee Arthroplasty: A Finite Element Analysis
INTRODUCTION: Improvement in diagnostic and surgical techniques in hip arthroscopy have led to a surge in hip distraction procedures over the recent years with the predicted annual frequency being four out of every 10,000 orthopedic procedures in 2017. Due to the large traction force required to achieve the appropriate joint spacing intra-operatively, an emergence of traction-related neurological and soft tissue injuries have surfaced. Pre-existing hip joint pathologies and surgical procedures disrupt the biomechanical stability of the joint and significantly increase the risk of iatrogenic damage. Furthermore, patients with total knee arthroplasties are often subject to intra-articular ligament releases, leading to reduced stability; however, it is not well understood how this may impact their outcomes of hip arthroscopic procedures. The current study aims to investigate the biomechanical behavior of various instrumented knee joints subjected to traction forces to aid clinical understanding and advancements of hip arthroscopy techniques. METHODS: A validated finite element (FE) model of the pelvis and lower extremity was developed from computed tomography (CT) scans of a healthy 45-year-old female. Three different models were assembled according to different TKA techniques performed: Bi-Cruciate Retaining (BCR) model, Posterior-Cruciate Retaining (PCR) model, and Posterior Stabilized (PS) model. The BCR model is noted by retaining all native ligaments of the knee joint (ACL, PCL, MCL, and LCL), whereas the PCR model was subject to ACL removal and the PS model required ACL and PCL removal (Figure 1). The pelvis was encastered to prevent translation under the traction forces as motion of the patient’s trunk is restrained, intraoperatively. To simulate the loading condition of hip distraction, an axial force was coupled to the distal fibula and tibia and incrementally increased from 100N to 500N. Joint spacing and ligament strain in the hip and knee joint were analyzed to assess the effects of traction forces. RESULTS: The medial and lateral compartment stiffness of the knee joint was analyzed under hip distraction for the three different TKA scenarios. The BCR model displayed the greatest average knee complex stiffness. Release of the ACL resulted in a larger decrease of stiffness compared to release of the PCL. There was no change in forces required for hip distraction as result of changes in the knee joint stiffness (Figure 3). The PCR and PS models were subject to excess knee joint distraction that exceeded 12 mm and ligament strain greater than 20% before adequate hip joint distraction of 10 mm was achieved. The BCR model remained below 10 mm of knee distraction and 15% ligament strain at 10 mm of hip joint distraction. DISCUSSION: Our study reveals patients undergoing hip distraction with a prior TKA may experience increased soft tissue damage or iatrogenic dislocation due to reduced knee joint stability. The PCR and PS models outline a trend suggesting patients who have undergone ligament sacrificing TKAs experience large reductions in knee joint stability, causing strain levels that are indicative of soft tissue injury. The BCR TKA was indicated to be the safest under the distraction conditions as joint spacing and strain levels were largely reduced comparatively; however, when surpassing 10 mm of knee joint distraction at forces greater than 350 N, the strain levels in the ACL suggest minor injury may occur.
Open AccessSoft Tissue Mechanics in Hip Distraction after Total Knee Arthroplasty: A Finite Element Analysis
INTRODUCTION: Improvement in diagnostic and surgical techniques in hip arthroscopy have led to a surge in hip distraction procedures over the recent years with the predicted annual frequency being four out of every 10,000 orthopedic procedures in 2017. Due to the large traction force required to achieve the appropriate joint spacing intra-operatively, an emergence of traction-related neurological and soft tissue injuries have surfaced. Pre-existing hip joint pathologies and surgical procedures disrupt the biomechanical stability of the joint and significantly increase the risk of iatrogenic damage. Furthermore, patients with total knee arthroplasties are often subject to intra-articular ligament releases, leading to reduced stability; however, it is not well understood how this may impact their outcomes of hip arthroscopic procedures. The current study aims to investigate the biomechanical behavior of various instrumented knee joints subjected to traction forces to aid clinical understanding and advancements of hip arthroscopy techniques. METHODS: A validated finite element (FE) model of the pelvis and lower extremity was developed from computed tomography (CT) scans of a healthy 45-year-old female. Three different models were assembled according to different TKA techniques performed: Bi-Cruciate Retaining (BCR) model, Posterior-Cruciate Retaining (PCR) model, and Posterior Stabilized (PS) model. The BCR model is noted by retaining all native ligaments of the knee joint (ACL, PCL, MCL, and LCL), whereas the PCR model was subject to ACL removal and the PS model required ACL and PCL removal (Figure 1). The pelvis was encastered to prevent translation under the traction forces as motion of the patient’s trunk is restrained, intraoperatively. To simulate the loading condition of hip distraction, an axial force was coupled to the distal fibula and tibia and incrementally increased from 100N to 500N. Joint spacing and ligament strain in the hip and knee joint were analyzed to assess the effects of traction forces. RESULTS: The medial and lateral compartment stiffness of the knee joint was analyzed under hip distraction for the three different TKA scenarios. The BCR model displayed the greatest average knee complex stiffness. Release of the ACL resulted in a larger decrease of stiffness compared to release of the PCL. There was no change in forces required for hip distraction as result of changes in the knee joint stiffness (Figure 3). The PCR and PS models were subject to excess knee joint distraction that exceeded 12 mm and ligament strain greater than 20% before adequate hip joint distraction of 10 mm was achieved. The BCR model remained below 10 mm of knee distraction and 15% ligament strain at 10 mm of hip joint distraction. DISCUSSION: Our study reveals patients undergoing hip distraction with a prior TKA may experience increased soft tissue damage or iatrogenic dislocation due to reduced knee joint stability. The PCR and PS models outline a trend suggesting patients who have undergone ligament sacrificing TKAs experience large reductions in knee joint stability, causing strain levels that are indicative of soft tissue injury. The BCR TKA was indicated to be the safest under the distraction conditions as joint spacing and strain levels were largely reduced comparatively; however, when surpassing 10 mm of knee joint distraction at forces greater than 350 N, the strain levels in the ACL suggest minor injury may occur.
- Open Access
- 6 January 2024
- Published by Elsevier in Clinical Biomechanics
- Vol. 112, 106170
Two-to-three times increase in natural hip and lumbar non-sagittal plane kinematics can lead to anterior cruciate ligament injury and cartilage failure scenarios during single-leg landings
- 6 January 2024
- Published by Elsevier in Clinical Biomechanics
- Vol. 112, 106170
Open AccessTwo-to-three times increase in natural hip and lumbar non-sagittal plane kinematics can lead to anterior cruciate ligament injury and cartilage failure scenarios during single-leg landings
- 1 June 2023
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 51 (8) , 2098-2109
Effect of Whole Body Parameters on Knee Joint Biomechanics: Implications for ACL Injury Prevention During Single-Leg Landings
Background: Previous studies have examined the effect of whole body (WB) parameters on anterior cruciate ligament (ACL) strain and loads, as well as knee joint kinetics and kinematics. However, articular cartilage damage occurs in relation to ACL failure, and the effect of WB parameters on ACL strain and articular cartilage biomechanics during dynamic tasks is unclear. Purposes: (1) To investigate the effect of WB parameters on ACL strain, as well as articular cartilage stress and contact force, during a single-leg cross drop (SLCD) and single-leg drop (SLD). (2) To identify WB parameters predictive of high ACL strain during these tasks. Study Design: Descriptive laboratory study. Methods: Three-dimensional motion analysis data from 14 physically active men and women were recorded during an SLCD and SLD. OpenSim was used to obtain their kinematics, kinetics, and muscle forces for the WB model. Using these data in kinetically driven finite element simulations of the knee joint produced outputs of ACL strains and articular cartilage stresses and contact forces. Spearman correlation coefficients were used to assess relationships between WB parameters and ACL strain and cartilage biomechanics. Moreover, receiver operating characteristic curve analyses and multivariate binary logistic regressions were used to find the WB parameters that could discriminate high from low ACL strain trials. Results: Correlations showed that more lumbar rotation away from the stance limb at peak ACL strain had the strongest overall association (ρ = 0.877) with peak ACL strain. Higher knee anterior shear force (ρ = 0.895) and lower gluteus maximus muscle force (ρ = 0.89) at peak ACL strain demonstrated the strongest associations with peak articular cartilage stress or contact force in ≥1 of the analyzed tasks. The regression model that used muscle forces to predict high ACL strain trials during the dominant limb SLD yielded the highest accuracy (93.5%), sensitivity (0.881), and specificity (0.952) among all regression models. Conclusion: WB parameters that were most consistently associated with and predictive of high ACL strain and poor articular cartilage biomechanics during the SLCD and SLD tasks included greater knee abduction angle at initial contact and higher anterior shear force at peak ACL strain, as well as lower gracilis, gluteus maximus, and medial gastrocnemius muscle forces. Clinical relevance: Knowledge of which landing postures create a high risk for ACL or cartilage injury may help reduce injuries in athletes by avoiding those postures and practicing the tasks with reduced high-risk motions, as well as by strengthening the muscles that protect the knee during single-leg landings.
- 1 June 2023
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 51 (8) , 2098-2109
Effect of Whole Body Parameters on Knee Joint Biomechanics: Implications for ACL Injury Prevention During Single-Leg Landings
Background: Previous studies have examined the effect of whole body (WB) parameters on anterior cruciate ligament (ACL) strain and loads, as well as knee joint kinetics and kinematics. However, articular cartilage damage occurs in relation to ACL failure, and the effect of WB parameters on ACL strain and articular cartilage biomechanics during dynamic tasks is unclear. Purposes: (1) To investigate the effect of WB parameters on ACL strain, as well as articular cartilage stress and contact force, during a single-leg cross drop (SLCD) and single-leg drop (SLD). (2) To identify WB parameters predictive of high ACL strain during these tasks. Study Design: Descriptive laboratory study. Methods: Three-dimensional motion analysis data from 14 physically active men and women were recorded during an SLCD and SLD. OpenSim was used to obtain their kinematics, kinetics, and muscle forces for the WB model. Using these data in kinetically driven finite element simulations of the knee joint produced outputs of ACL strains and articular cartilage stresses and contact forces. Spearman correlation coefficients were used to assess relationships between WB parameters and ACL strain and cartilage biomechanics. Moreover, receiver operating characteristic curve analyses and multivariate binary logistic regressions were used to find the WB parameters that could discriminate high from low ACL strain trials. Results: Correlations showed that more lumbar rotation away from the stance limb at peak ACL strain had the strongest overall association (ρ = 0.877) with peak ACL strain. Higher knee anterior shear force (ρ = 0.895) and lower gluteus maximus muscle force (ρ = 0.89) at peak ACL strain demonstrated the strongest associations with peak articular cartilage stress or contact force in ≥1 of the analyzed tasks. The regression model that used muscle forces to predict high ACL strain trials during the dominant limb SLD yielded the highest accuracy (93.5%), sensitivity (0.881), and specificity (0.952) among all regression models. Conclusion: WB parameters that were most consistently associated with and predictive of high ACL strain and poor articular cartilage biomechanics during the SLCD and SLD tasks included greater knee abduction angle at initial contact and higher anterior shear force at peak ACL strain, as well as lower gracilis, gluteus maximus, and medial gastrocnemius muscle forces. Clinical relevance: Knowledge of which landing postures create a high risk for ACL or cartilage injury may help reduce injuries in athletes by avoiding those postures and practicing the tasks with reduced high-risk motions, as well as by strengthening the muscles that protect the knee during single-leg landings.
- 26 July 2022
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 51 (1) , 24-33
A Validated Open-Source Shoulder Finite Element Model and Investigation of the Effect of Analysis Precision
Understanding the loads and stresses on different tissues within the shoulder complex is crucial for preventing joint injury and developing shoulder implants. Finite element (FE) models of the shoulder joint can be helpful in describing these forces and the biomechanics of the joint. Currently, there are no validated FE models of the intact shoulder available in the public domain. This study aimed to develop and validate a shoulder FE model, then make the model available to the orthopaedic research community. Publicly available medical images of the Visible Human Project male subject’s right shoulder were used to generate the model geometry. Material properties from the literature were applied to the different tissues. The model simulated abduction in the scapular plane. Simulated glenohumeral (GH) contact force was compared to in vivo data from the literature, then further compared to other in vitro experimental studies. Output variable results were within one standard deviation of the mean in vivo experimental values of the GH contact force in 0°, 10°, 20°, 30°, and 45° of abduction. Furthermore, a comparison among different analysis precision in the Abaqus/Explicit platform was made. The complete shoulder model is available for download at github.com/OSEL-DAM/ShoulderFiniteElementModel.
- 26 July 2022
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 51 (1) , 24-33
A Validated Open-Source Shoulder Finite Element Model and Investigation of the Effect of Analysis Precision
Understanding the loads and stresses on different tissues within the shoulder complex is crucial for preventing joint injury and developing shoulder implants. Finite element (FE) models of the shoulder joint can be helpful in describing these forces and the biomechanics of the joint. Currently, there are no validated FE models of the intact shoulder available in the public domain. This study aimed to develop and validate a shoulder FE model, then make the model available to the orthopaedic research community. Publicly available medical images of the Visible Human Project male subject’s right shoulder were used to generate the model geometry. Material properties from the literature were applied to the different tissues. The model simulated abduction in the scapular plane. Simulated glenohumeral (GH) contact force was compared to in vivo data from the literature, then further compared to other in vitro experimental studies. Output variable results were within one standard deviation of the mean in vivo experimental values of the GH contact force in 0°, 10°, 20°, 30°, and 45° of abduction. Furthermore, a comparison among different analysis precision in the Abaqus/Explicit platform was made. The complete shoulder model is available for download at github.com/OSEL-DAM/ShoulderFiniteElementModel.
- 17 June 2021
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 143 (10)
Tibiofemoral Cartilage Contact Pressures in Athletes During Landing: A Dynamic Finite Element Study
Cartilage defects are common in the knee joint of active athletes and remain a problem as a strong risk factor for osteoarthritis. We hypothesized that landing during sport activities, implication for subfailure ACL loading, would generate greater contact pressures (CP) at the lateral knee compartment. The purpose of this study is to investigate tibiofemoral cartilage CP of athletes during landing. Tibiofemoral cartilage contact pressures (TCCP) under clinically relevant anterior cruciate ligament subfailure external loadings were predicted using four dynamic explicit finite element (FE) models (2 males and 2 females) of the knee. Bipedal landing from a jump for five cases of varying magnitudes of external loadings (knee abduction moment, internal tibial torque, and anterior tibial shear) followed by an impact load were simulated. Lateral TCCP from meniscus (area under meniscus) and from femur (area under femur) increased by up to 94% and %30 respectively when external loads were incorporated with impact load in all the models compared to impact-only case. In addition, FE model predicted higher CP in lateral compartment by up to 37% (11.87 MPa versus 8.67 MPa) and 52% (20.19 MPa versus 13.29 MPa) for 90% and 50% percentile models, respectively. For the same percentile populations, CPs were higher by up to 25% and 82% in smaller size models than larger size models. We showed that subfailure ACL loadings obtained from previously conducted in vivo study led to high pressures on the tibiofemoral cartilage. This knowledge is helpful in enhancing neuromuscular training for athletes to prevent cartilage damage.
- 17 June 2021
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 143 (10)
Tibiofemoral Cartilage Contact Pressures in Athletes During Landing: A Dynamic Finite Element Study
Cartilage defects are common in the knee joint of active athletes and remain a problem as a strong risk factor for osteoarthritis. We hypothesized that landing during sport activities, implication for subfailure ACL loading, would generate greater contact pressures (CP) at the lateral knee compartment. The purpose of this study is to investigate tibiofemoral cartilage CP of athletes during landing. Tibiofemoral cartilage contact pressures (TCCP) under clinically relevant anterior cruciate ligament subfailure external loadings were predicted using four dynamic explicit finite element (FE) models (2 males and 2 females) of the knee. Bipedal landing from a jump for five cases of varying magnitudes of external loadings (knee abduction moment, internal tibial torque, and anterior tibial shear) followed by an impact load were simulated. Lateral TCCP from meniscus (area under meniscus) and from femur (area under femur) increased by up to 94% and %30 respectively when external loads were incorporated with impact load in all the models compared to impact-only case. In addition, FE model predicted higher CP in lateral compartment by up to 37% (11.87 MPa versus 8.67 MPa) and 52% (20.19 MPa versus 13.29 MPa) for 90% and 50% percentile models, respectively. For the same percentile populations, CPs were higher by up to 25% and 82% in smaller size models than larger size models. We showed that subfailure ACL loadings obtained from previously conducted in vivo study led to high pressures on the tibiofemoral cartilage. This knowledge is helpful in enhancing neuromuscular training for athletes to prevent cartilage damage.