Anne Vakkuri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Anne Vakkuri has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Noora Skants
Anesthesia and Surgery Unit, Peijas Hospital HUS Helsinki University Hospital and University of Helsinki Vantaa Finland
6 shared publications - Riikka Vuokko
Department for Steering of Healthcare and Social Welfare, Ministry of Social Affairs and Health, PO Box 33, Helsinki, FI-00023, Finland, 358 295 16001
5 shared publications - Sari Palojoki
Department for Steering of Healthcare and Social Welfare, Ministry of Social Affairs and Health, PO Box 33, Helsinki, FI-00023, Finland, 358 295 16001
5 shared publications - Mikko Rantasalo
Orton Orthopaedic Hospital, Helsinki, Finland
4 shared publications - Riku Palanne
Department of Anaesthesiology, Intensive Care and Pain Medicine Peijas Hospital, University of Helsinki and HUS Helsinki University Hospital Vantaa Finland
4 shared publications A. Yli‐Hankala
Department of Anesthesia, Tampere University Hospital, Tampere
3 shared publications
Latest Publications
- Open Access
- 26 May 2023
- Published by Wiley in European journal of pain
- Vol. 27 (8) , 961-972
Testing of a predictive risk index for persistent postsurgical pain on patients undergoing total knee arthroplasty: A prospective cohort study
Background: We investigated whether a universal predictive risk index for persistent postsurgical pain (PPP) is applicable to patients who undergo total knee arthroplasty (TKA).Methods: In this cohort study, 392 participants of a randomized study investigating the effects of anaesthesia methods and tourniquet use on TKA were divided into low‐, moderate‐, and high‐risk groups for PPP, as suggested in the previous risk index study. Patients reported pain using the Oxford Knee Score pain subscale and Brief Pain Inventory–short form preoperatively and 3 and 12 months postoperatively. We compared the pain scores of the low‐ to moderate‐ and high‐risk groups at respective time points and investigated changes in pain scores and the prevalence of PPP at 3 and 12 months after surgery.Results: The high‐risk group reported more pain 3 and 12 months after TKA than the low‐ to moderate‐risk group. However, of seven variables, only a single difference reached the threshold for minimal clinical importance between the groups at 12 months. Additionally, at 12 months, the low‐ to moderate‐risk group reported slightly worse improvements in three of seven pain variables than the high‐risk group. Depending on the definition, the prevalence of PPP ranged from 2% to 29% in the low‐ to moderate‐risk group and 4% to 41% in the high‐risk group 12 months postoperatively.Conclusions: Although the investigated risk index might predict clinically important differences in PPP between the risk groups at 3 months after TKA, it seems poorly applicable for predicting PPP at 12 months after TKA.Significance: Although many risk factors for persistent postsurgical pain after total knee arthroplasty have been identified, predicting the risk of this pain has remained a challenge. Results of the current study suggest that accumulation of previously presented modifiable risk factors might be associated with increased postsurgical pain at 3 months, but not at 12 months after total knee arthroplasty.
- 26 May 2023
- Published by Wiley in European journal of pain
- Vol. 27 (8) , 961-972
Open AccessTesting of a predictive risk index for persistent postsurgical pain on patients undergoing total knee arthroplasty: A prospective cohort study
Background: We investigated whether a universal predictive risk index for persistent postsurgical pain (PPP) is applicable to patients who undergo total knee arthroplasty (TKA).Methods: In this cohort study, 392 participants of a randomized study investigating the effects of anaesthesia methods and tourniquet use on TKA were divided into low‐, moderate‐, and high‐risk groups for PPP, as suggested in the previous risk index study. Patients reported pain using the Oxford Knee Score pain subscale and Brief Pain Inventory–short form preoperatively and 3 and 12 months postoperatively. We compared the pain scores of the low‐ to moderate‐ and high‐risk groups at respective time points and investigated changes in pain scores and the prevalence of PPP at 3 and 12 months after surgery.Results: The high‐risk group reported more pain 3 and 12 months after TKA than the low‐ to moderate‐risk group. However, of seven variables, only a single difference reached the threshold for minimal clinical importance between the groups at 12 months. Additionally, at 12 months, the low‐ to moderate‐risk group reported slightly worse improvements in three of seven pain variables than the high‐risk group. Depending on the definition, the prevalence of PPP ranged from 2% to 29% in the low‐ to moderate‐risk group and 4% to 41% in the high‐risk group 12 months postoperatively.Conclusions: Although the investigated risk index might predict clinically important differences in PPP between the risk groups at 3 months after TKA, it seems poorly applicable for predicting PPP at 12 months after TKA.Significance: Although many risk factors for persistent postsurgical pain after total knee arthroplasty have been identified, predicting the risk of this pain has remained a challenge. Results of the current study suggest that accumulation of previously presented modifiable risk factors might be associated with increased postsurgical pain at 3 months, but not at 12 months after total knee arthroplasty.
- Open Access
- 6 February 2023
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 11, e43750
Systematized Nomenclature of Medicine–Clinical Terminology (SNOMED CT) Clinical Use Cases in the Context of Electronic Health Record Systems: Systematic Literature Review
Background: The Systematized Medical Nomenclature for Medicine–Clinical Terminology (SNOMED CT) is a clinical terminology system that provides a standardized and scientifically validated way of representing clinical information captured by clinicians. It can be integrated into electronic health records (EHRs) to increase the possibilities for effective data use and ensure a better quality of documentation that supports continuity of care, thus enabling better quality in the care process. Even though SNOMED CT consists of extensively studied clinical terminology, previous research has repeatedly documented a lack of scientific evidence for SNOMED CT in the form of reported clinical use cases in electronic health record systems. Objective: The aim of this study was to explore evidence in previous literature reviews of clinical use cases of SNOMED CT integrated into EHR systems or other clinical applications during the last 5 years of continued development. The study sought to identify the main clinical use purposes, use phases, and key clinical benefits documented in SNOMED CT use cases. Methods: The Cochrane review protocol was applied for the study design. The application of the protocol was modified step-by-step to fit the research problem by first defining the search strategy, identifying the articles for the review by isolating the exclusion and inclusion criteria for assessing the search results, and lastly, evaluating and summarizing the review results. Results: In total, 17 research articles illustrating SNOMED CT clinical use cases were reviewed. The use purpose of SNOMED CT was documented in all the articles, with the terminology as a standard in EHR being the most common (8/17). The clinical use phase was documented in all the articles. The most common category of use phases was SNOMED CT in development (6/17). Core benefits achieved by applying SNOMED CT in a clinical context were identified by the researchers. These were related to terminology use outcomes, that is, to data quality in general or to enabling a consistent way of indexing, storing, retrieving, and aggregating clinical data (8/17). Additional benefits were linked to the productivity of coding or to advances in the quality and continuity of care. Conclusions: While the SNOMED CT use categories were well supported by previous research, this review demonstrates that further systematic research on clinical use cases is needed to promote the scalability of the review results. To achieve the best out-of-use case reports, more emphasis is suggested on describing the contextual factors, such as the electronic health care system and the use of previous frameworks to enable comparability of results. A lesson to be drawn from our study is that SNOMED CT is essential for structuring clinical data; however, research is needed to gather more evidence of how SNOMED CT benefits clinical care and patient safety.
- 6 February 2023
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 11, e43750
Open AccessSystematized Nomenclature of Medicine–Clinical Terminology (SNOMED CT) Clinical Use Cases in the Context of Electronic Health Record Systems: Systematic Literature Review
Background: The Systematized Medical Nomenclature for Medicine–Clinical Terminology (SNOMED CT) is a clinical terminology system that provides a standardized and scientifically validated way of representing clinical information captured by clinicians. It can be integrated into electronic health records (EHRs) to increase the possibilities for effective data use and ensure a better quality of documentation that supports continuity of care, thus enabling better quality in the care process. Even though SNOMED CT consists of extensively studied clinical terminology, previous research has repeatedly documented a lack of scientific evidence for SNOMED CT in the form of reported clinical use cases in electronic health record systems. Objective: The aim of this study was to explore evidence in previous literature reviews of clinical use cases of SNOMED CT integrated into EHR systems or other clinical applications during the last 5 years of continued development. The study sought to identify the main clinical use purposes, use phases, and key clinical benefits documented in SNOMED CT use cases. Methods: The Cochrane review protocol was applied for the study design. The application of the protocol was modified step-by-step to fit the research problem by first defining the search strategy, identifying the articles for the review by isolating the exclusion and inclusion criteria for assessing the search results, and lastly, evaluating and summarizing the review results. Results: In total, 17 research articles illustrating SNOMED CT clinical use cases were reviewed. The use purpose of SNOMED CT was documented in all the articles, with the terminology as a standard in EHR being the most common (8/17). The clinical use phase was documented in all the articles. The most common category of use phases was SNOMED CT in development (6/17). Core benefits achieved by applying SNOMED CT in a clinical context were identified by the researchers. These were related to terminology use outcomes, that is, to data quality in general or to enabling a consistent way of indexing, storing, retrieving, and aggregating clinical data (8/17). Additional benefits were linked to the productivity of coding or to advances in the quality and continuity of care. Conclusions: While the SNOMED CT use categories were well supported by previous research, this review demonstrates that further systematic research on clinical use cases is needed to promote the scalability of the review results. To achieve the best out-of-use case reports, more emphasis is suggested on describing the contextual factors, such as the electronic health care system and the use of previous frameworks to enable comparability of results. A lesson to be drawn from our study is that SNOMED CT is essential for structuring clinical data; however, research is needed to gather more evidence of how SNOMED CT benefits clinical care and patient safety.
- Open Access
- 14 April 2022
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 93, 432-437
Postoperative pain as a risk factor for stiff knee following total knee arthroplasty and excellent patientreported outcomes after manipulation under anesthesia
Background and purpose: Manipulation under anesthesia (MUA) is the first-choice treatment for stiffness following total knee arthroplasty (TKA) unresponsive to pain management and physiotherapy. Some of the predisposing factors and patient-reported outcome measures (PROMs) following MUA remain poorly studied. We retrospectively investigated the etiological risk factors and the outcomes of MUA.Patients and methods: 391 TKA patients from a randomized trial comparing the use of a tourniquet and anesthesia (spinal or general) were analyzed, and patients needing MUA were identified (MUA group). We evaluated in-hospital opioid consumption, Oxford Knee Score (OKS), range of motion (ROM), and pain assessed by the Brief Pain Inventory-short form with a 1-year follow-up.Results: 39 (10%) MUA patients were identified. The MUA patients were younger (60 years vs. 64 years, difference –4, 95% CI –6 to –1) and had higher postoperative oxycodone consumption (66 mg vs. 51 mg, median difference 11, CI 1–22) than the no-MUA patients. The proportion of MUA patients who contacted the emergency department within 3 months because of pain was larger than that of non-MUA patients (41% vs. 12%, OR 5, CI 3–10). At the 1-year follow-up, the ROM was improved by 39° following MUA, but the total ROM was worse in the MUA group (115° vs. 124°, p < 0.001). No difference was found in the OKS between the MUA and no-MUA patients.Interpretation: Higher postoperative pain seems to predict MUA risk. MUA performed 3 months postoperatively offers substantial ROM improvement and comparable PROMs to no-MUA patients 1 year after TKA.
- 14 April 2022
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 93, 432-437
Open AccessPostoperative pain as a risk factor for stiff knee following total knee arthroplasty and excellent patientreported outcomes after manipulation under anesthesia
Background and purpose: Manipulation under anesthesia (MUA) is the first-choice treatment for stiffness following total knee arthroplasty (TKA) unresponsive to pain management and physiotherapy. Some of the predisposing factors and patient-reported outcome measures (PROMs) following MUA remain poorly studied. We retrospectively investigated the etiological risk factors and the outcomes of MUA.Patients and methods: 391 TKA patients from a randomized trial comparing the use of a tourniquet and anesthesia (spinal or general) were analyzed, and patients needing MUA were identified (MUA group). We evaluated in-hospital opioid consumption, Oxford Knee Score (OKS), range of motion (ROM), and pain assessed by the Brief Pain Inventory-short form with a 1-year follow-up.Results: 39 (10%) MUA patients were identified. The MUA patients were younger (60 years vs. 64 years, difference –4, 95% CI –6 to –1) and had higher postoperative oxycodone consumption (66 mg vs. 51 mg, median difference 11, CI 1–22) than the no-MUA patients. The proportion of MUA patients who contacted the emergency department within 3 months because of pain was larger than that of non-MUA patients (41% vs. 12%, OR 5, CI 3–10). At the 1-year follow-up, the ROM was improved by 39° following MUA, but the total ROM was worse in the MUA group (115° vs. 124°, p < 0.001). No difference was found in the OKS between the MUA and no-MUA patients.Interpretation: Higher postoperative pain seems to predict MUA risk. MUA performed 3 months postoperatively offers substantial ROM improvement and comparable PROMs to no-MUA patients 1 year after TKA.
- Open Access
- 29 March 2022
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 6 (3) , e35474
Preliminary Exploration of Main Elements for Systematic Classification Development: Case Study of Patient Safety Incidents
Background: Currently, there is no holistic theoretical approach available for guiding classification development. On the basis of our recent classification development research in the area of patient safety in health information technology, this focus area would benefit from a more systematic approach. Although some valuable theoretical and methodological approaches have been presented, classification development literature typically is limited to methodological development in a specific domain or is practically oriented. Objective: The main purposes of this study are to fill the methodological gap in classification development research by exploring possible elements of systematic development based on previous literature and to promote sustainable and well-grounded classification outcomes by identifying a set of recommended elements. Specifically, the aim is to answer the following question: what are the main elements for systematic classification development based on research evidence and our use case? Methods: This study applied a qualitative research approach. On the basis of previous literature, preliminary elements for classification development were specified, as follows: defining a concept model, documenting the development process, incorporating multidisciplinary expertise, validating results, and maintaining the classification. The elements were compiled as guiding principles for the research process and tested in the case of patient safety incidents (n=501). Results: The results illustrate classification development based on the chosen elements, with 4 examples of technology-induced errors. Examples from the use case regard usability, system downtime, clinical workflow, and medication section problems. The study results confirm and thus suggest that a more comprehensive and theory-based systematic approach promotes well-grounded classification work by enhancing transparency and possibilities for assessing the development process. Conclusions: We recommend further testing the preliminary main elements presented in this study. The research presented herein could serve as a basis for future work. Our recently developed classification and the use case presented here serve as examples. Data retrieved from, for example, other type of electronic health records and use contexts could refine and validate the suggested methodological approach.
- 29 March 2022
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 6 (3) , e35474
Open AccessPreliminary Exploration of Main Elements for Systematic Classification Development: Case Study of Patient Safety Incidents
Background: Currently, there is no holistic theoretical approach available for guiding classification development. On the basis of our recent classification development research in the area of patient safety in health information technology, this focus area would benefit from a more systematic approach. Although some valuable theoretical and methodological approaches have been presented, classification development literature typically is limited to methodological development in a specific domain or is practically oriented. Objective: The main purposes of this study are to fill the methodological gap in classification development research by exploring possible elements of systematic development based on previous literature and to promote sustainable and well-grounded classification outcomes by identifying a set of recommended elements. Specifically, the aim is to answer the following question: what are the main elements for systematic classification development based on research evidence and our use case? Methods: This study applied a qualitative research approach. On the basis of previous literature, preliminary elements for classification development were specified, as follows: defining a concept model, documenting the development process, incorporating multidisciplinary expertise, validating results, and maintaining the classification. The elements were compiled as guiding principles for the research process and tested in the case of patient safety incidents (n=501). Results: The results illustrate classification development based on the chosen elements, with 4 examples of technology-induced errors. Examples from the use case regard usability, system downtime, clinical workflow, and medication section problems. The study results confirm and thus suggest that a more comprehensive and theory-based systematic approach promotes well-grounded classification work by enhancing transparency and possibilities for assessing the development process. Conclusions: We recommend further testing the preliminary main elements presented in this study. The research presented herein could serve as a basis for future work. Our recently developed classification and the use case presented here serve as examples. Data retrieved from, for example, other type of electronic health records and use contexts could refine and validate the suggested methodological approach.
- Open Access
- 6 December 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Preliminary Exploration of Main Elements for Systematic Classification Development: Case Study of Patient Safety Incidents (Preprint)
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Currently, there is no holistic theoretical approach available for guiding classification development. On the basis of our recent classification development research in the area of patient safety in health information technology, this focus area would benefit from a more systematic approach. Although some valuable theoretical and methodological approaches have been presented, classification development literature typically is limited to methodological development in a specific domain or is practically oriented. Objective: The main purposes of this study are to fill the methodological gap in classification development research by exploring possible elements of systematic development based on previous literature and to promote sustainable and well-grounded classification outcomes by identifying a set of recommended elements. Specifically, the aim is to answer the following question: what are the main elements for systematic classification development based on research evidence and our use case? Methods: This study applied a qualitative research approach. On the basis of previous literature, preliminary elements for classification development were specified, as follows: defining a concept model, documenting the development process, incorporating multidisciplinary expertise, validating results, and maintaining the classification. The elements were compiled as guiding principles for the research process and tested in the case of patient safety incidents (n=501). Results: The results illustrate classification development based on the chosen elements, with 4 examples of technology-induced errors. Examples from the use case regard usability, system downtime, clinical workflow, and medication section problems. The study results confirm and thus suggest that a more comprehensive and theory-based systematic approach promotes well-grounded classification work by enhancing transparency and possibilities for assessing the development process. Conclusions: We recommend further testing the preliminary main elements presented in this study. The research presented herein could serve as a basis for future work. Our recently developed classification and the use case presented here serve as examples. Data retrieved from, for example, other type of electronic health records and use contexts could refine and validate the suggested methodological approach. Trial Registration:
- 6 December 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessPreliminary Exploration of Main Elements for Systematic Classification Development: Case Study of Patient Safety Incidents (Preprint)
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Currently, there is no holistic theoretical approach available for guiding classification development. On the basis of our recent classification development research in the area of patient safety in health information technology, this focus area would benefit from a more systematic approach. Although some valuable theoretical and methodological approaches have been presented, classification development literature typically is limited to methodological development in a specific domain or is practically oriented. Objective: The main purposes of this study are to fill the methodological gap in classification development research by exploring possible elements of systematic development based on previous literature and to promote sustainable and well-grounded classification outcomes by identifying a set of recommended elements. Specifically, the aim is to answer the following question: what are the main elements for systematic classification development based on research evidence and our use case? Methods: This study applied a qualitative research approach. On the basis of previous literature, preliminary elements for classification development were specified, as follows: defining a concept model, documenting the development process, incorporating multidisciplinary expertise, validating results, and maintaining the classification. The elements were compiled as guiding principles for the research process and tested in the case of patient safety incidents (n=501). Results: The results illustrate classification development based on the chosen elements, with 4 examples of technology-induced errors. Examples from the use case regard usability, system downtime, clinical workflow, and medication section problems. The study results confirm and thus suggest that a more comprehensive and theory-based systematic approach promotes well-grounded classification work by enhancing transparency and possibilities for assessing the development process. Conclusions: We recommend further testing the preliminary main elements presented in this study. The research presented herein could serve as a basis for future work. Our recently developed classification and the use case presented here serve as examples. Data retrieved from, for example, other type of electronic health records and use contexts could refine and validate the suggested methodological approach. Trial Registration:
- Open Access
- 31 August 2021
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 9 (8) , e30470
Classification of Electronic Health Record–Related Patient Safety Incidents: Development and Validation Study
Background: It is assumed that the implementation of health information technology introduces new vulnerabilities within a complex sociotechnical health care system, but no international consensus exists on a standardized format for enhancing the collection, analysis, and interpretation of technology-induced errors.Objective: This study aims to develop a classification for patient safety incident reporting associated with the use of mature electronic health records (EHRs). It also aims to validate the classification by using a data set of incidents during a 6-month period immediately after the implementation of a new EHR system.Methods: The starting point of the classification development was the Finnish Technology-Induced Error Risk Assessment Scale tool, based on research on commonly recognized error types. A multiprofessional research team used iterative tests on consensus building to develop a classification system. The final classification, with preliminary descriptions of classes, was validated by applying it to analyze EHR-related error incidents (n=428) during the implementation phase of a new EHR system and also to evaluate this classification’s characteristics and applicability for reporting incidents. Interrater agreement was applied.Results: The number of EHR-related patient safety incidents during the implementation period (n=501) was five-fold when compared with the preimplementation period (n=82). The literature identified new error types that were added to the emerging classification. Error types were adapted iteratively after several test rounds to develop a classification for reporting patient safety incidents in the clinical use of a high-maturity EHR system. Of the 427 classified patient safety incidents, interface problems accounted for 96 (22.5%) incident reports, usability problems for 73 (17.1%), documentation problems for 60 (14.1%), and clinical workflow problems for 33 (7.7%). Altogether, 20.8% (89/427) of reports were related to medication section problems, and downtime problems were rare (n=8). During the classification work, 14.8% (74/501) of reports of the original sample were rejected because of insufficient information, even though the reports were deemed to be related to EHRs. The interrater agreement during the blinded review was 97.7%.Conclusions: This study presents a new classification for EHR-related patient safety incidents applicable to mature EHRs. The number of EHR-related patient safety incidents during the implementation period may reflect patient safety challenges during the implementation of a new type of high-maturity EHR system. The results indicate that the types of errors previously identified in the literature change with the EHR development cycle.
- 31 August 2021
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 9 (8) , e30470
Open AccessClassification of Electronic Health Record–Related Patient Safety Incidents: Development and Validation Study
Background: It is assumed that the implementation of health information technology introduces new vulnerabilities within a complex sociotechnical health care system, but no international consensus exists on a standardized format for enhancing the collection, analysis, and interpretation of technology-induced errors.Objective: This study aims to develop a classification for patient safety incident reporting associated with the use of mature electronic health records (EHRs). It also aims to validate the classification by using a data set of incidents during a 6-month period immediately after the implementation of a new EHR system.Methods: The starting point of the classification development was the Finnish Technology-Induced Error Risk Assessment Scale tool, based on research on commonly recognized error types. A multiprofessional research team used iterative tests on consensus building to develop a classification system. The final classification, with preliminary descriptions of classes, was validated by applying it to analyze EHR-related error incidents (n=428) during the implementation phase of a new EHR system and also to evaluate this classification’s characteristics and applicability for reporting incidents. Interrater agreement was applied.Results: The number of EHR-related patient safety incidents during the implementation period (n=501) was five-fold when compared with the preimplementation period (n=82). The literature identified new error types that were added to the emerging classification. Error types were adapted iteratively after several test rounds to develop a classification for reporting patient safety incidents in the clinical use of a high-maturity EHR system. Of the 427 classified patient safety incidents, interface problems accounted for 96 (22.5%) incident reports, usability problems for 73 (17.1%), documentation problems for 60 (14.1%), and clinical workflow problems for 33 (7.7%). Altogether, 20.8% (89/427) of reports were related to medication section problems, and downtime problems were rare (n=8). During the classification work, 14.8% (74/501) of reports of the original sample were rejected because of insufficient information, even though the reports were deemed to be related to EHRs. The interrater agreement during the blinded review was 97.7%.Conclusions: This study presents a new classification for EHR-related patient safety incidents applicable to mature EHRs. The number of EHR-related patient safety incidents during the implementation period may reflect patient safety challenges during the implementation of a new type of high-maturity EHR system. The results indicate that the types of errors previously identified in the literature change with the EHR development cycle.
- Open Access
- 30 July 2021
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 135 (4) , 699-710
Anesthesia Method, Tourniquet Use, and Persistent Postsurgical Pain after Total Knee Arthroplasty: A Prespecified Secondary Analysis of a Randomized Trial
Background: Persistent postsurgical pain after total knee arthroplasty is a common problem and a major reason for patient dissatisfaction. This secondary analysis aimed to investigate the effects of anesthesia (spinal vs. general) and tourniquet use on persistent pain after total knee arthroplasty. Methods: In this secondary analysis of a previously presented parallel, single-center, randomized trial, 404 patients scheduled for total knee arthroplasty were randomized to spinal versus general anesthesia and no-tourniquet versus tourniquet groups. Patients assessed pain using the Brief Pain Inventory–short form preoperatively and 3 and 12 months postoperatively. The prespecified main outcome was the change in “average pain” measured with numerical 0 to 10 rating scale 1 yr postoperatively. The threshold for clinical importance between groups was set to 1.0. Results: The change in average pain scores 1 yr postoperatively did not differ between the spinal and general anesthesia groups (–2.6 [SD 2.5] vs. –2.3 [SD 2.5], respectively; mean difference, –0.4; 95% CI, –0.9 to 0.1; P = 0.150). The no-tourniquet group reported a smaller decrease in the average pain scores than the tourniquet group (–2.1 [SD 2.7] vs. –2.8 [SD 2.3]; mean difference, 0.6; 95% CI, 0.1 to 1.1; P = 0.012). After 1 yr, the scores concerning the mean of four pain severity variables (numerical rating scale) decreased more in the spinal than in the general anesthesia group (–2.3 [SD 2.2] vs. –1.8 [SD 2.1]; mean difference, –0.5; 95% CI, –0.9 to –0.05; P = 0.029) and less in the no-tourniquet than in the tourniquet group (–1.7 [SD 2.3] vs. –2.3 [SD 2.0]; mean difference, 0.6; 95% CI, 0.2 to 1.0; P = 0.005). None of the differences in pain scores reached the threshold for clinical importance. Conclusions: The type of anesthesia (spinal vs. general) or tourniquet use has no clinically important effect on persistent postsurgical pain after total knee arthroplasty. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:
- 30 July 2021
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 135 (4) , 699-710
Open AccessAnesthesia Method, Tourniquet Use, and Persistent Postsurgical Pain after Total Knee Arthroplasty: A Prespecified Secondary Analysis of a Randomized Trial
Background: Persistent postsurgical pain after total knee arthroplasty is a common problem and a major reason for patient dissatisfaction. This secondary analysis aimed to investigate the effects of anesthesia (spinal vs. general) and tourniquet use on persistent pain after total knee arthroplasty. Methods: In this secondary analysis of a previously presented parallel, single-center, randomized trial, 404 patients scheduled for total knee arthroplasty were randomized to spinal versus general anesthesia and no-tourniquet versus tourniquet groups. Patients assessed pain using the Brief Pain Inventory–short form preoperatively and 3 and 12 months postoperatively. The prespecified main outcome was the change in “average pain” measured with numerical 0 to 10 rating scale 1 yr postoperatively. The threshold for clinical importance between groups was set to 1.0. Results: The change in average pain scores 1 yr postoperatively did not differ between the spinal and general anesthesia groups (–2.6 [SD 2.5] vs. –2.3 [SD 2.5], respectively; mean difference, –0.4; 95% CI, –0.9 to 0.1; P = 0.150). The no-tourniquet group reported a smaller decrease in the average pain scores than the tourniquet group (–2.1 [SD 2.7] vs. –2.8 [SD 2.3]; mean difference, 0.6; 95% CI, 0.1 to 1.1; P = 0.012). After 1 yr, the scores concerning the mean of four pain severity variables (numerical rating scale) decreased more in the spinal than in the general anesthesia group (–2.3 [SD 2.2] vs. –1.8 [SD 2.1]; mean difference, –0.5; 95% CI, –0.9 to –0.05; P = 0.029) and less in the no-tourniquet than in the tourniquet group (–1.7 [SD 2.3] vs. –2.3 [SD 2.0]; mean difference, 0.6; 95% CI, 0.2 to 1.0; P = 0.005). None of the differences in pain scores reached the threshold for clinical importance. Conclusions: The type of anesthesia (spinal vs. general) or tourniquet use has no clinically important effect on persistent postsurgical pain after total knee arthroplasty. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:
- 15 June 2021
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (20) , 1890-1899
Use of a Tourniquet and Spinal Anesthesia Increases Satisfactory Outcomes After Total Knee Arthroplasty
Background: Total knee arthroplasty (TKA) is usually performed successfully with or without a tourniquet and under spinal anesthesia (SA) or general anesthesia (GA). However, 10% to 34% of patients experience dissatisfaction and pain after TKA. We aimed to compare the effects of tourniquet use and SA or GA on TKA outcomes. Methods: We randomly assigned 404 patients to 4 study groups: SA without a tourniquet (NT/SA), SA with a tourniquet (T/SA), GA without a tourniquet (NT/GA), and GA with a tourniquet (T/GA). The primary outcome was the change in the Oxford Knee Score (OKS) at 1 year postoperatively. Secondary outcomes included a satisfactory TKA outcome assessed using the OKS minimal important change (MIC) and OKS patient acceptable symptom state (PASS), adverse events, and quality of life using the 15-dimensional health-related quality of life tool. Results: At 1 year, the OKS was obtained for 381 patients. In the 2-group comparisons, the tourniquet did not affect the OKS improvement. The SA group had more substantial improvement in the OKS than the GA group (16.21 compared with 14.08 a mean difference of 2.13; 95% confidence interval [CI], 0.55 to 3.71; p = 0.008). In the 4-group comparisons, the T/SA group had more substantial improvements in the OKS than the NT/GA group (16.87 compared with 13.65, a mean difference of 3.2; 95% CI, 0.28 to 6.17; p = 0.026). The SA group reached the OKS MIC more frequently than the GA group (91.7% compared with 81.7%; odds ratio [OR] = 2.49 [95% CI, 1.32 to 4.69]; p = 0.005). The SA group also reached the OKS PASS more frequently than the GA group (86.0% compared with 75.7%; OR = 2.00 [95% CI, 1.18 to 3.39]; p = 0.010). The T/SA group had significantly more patients reaching the OKS MIC than the NT/GA group (95.7% compared with 79.6%; p = 0.005) and more patients reaching the OKS PASS than the NT/GA group (92.6% compared with 74.5%; p = 0.004). No differences were seen with respect to adverse events in any comparisons. Conclusions: The tourniquet had no detrimental effects on the outcomes of TKA. SA had a positive effect on the OKS. The use of SA combined with a tourniquet resulted in the best improvement in OKS and the highest proportion of satisfactory outcomes with TKA. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
- 15 June 2021
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (20) , 1890-1899
Use of a Tourniquet and Spinal Anesthesia Increases Satisfactory Outcomes After Total Knee Arthroplasty
Background: Total knee arthroplasty (TKA) is usually performed successfully with or without a tourniquet and under spinal anesthesia (SA) or general anesthesia (GA). However, 10% to 34% of patients experience dissatisfaction and pain after TKA. We aimed to compare the effects of tourniquet use and SA or GA on TKA outcomes. Methods: We randomly assigned 404 patients to 4 study groups: SA without a tourniquet (NT/SA), SA with a tourniquet (T/SA), GA without a tourniquet (NT/GA), and GA with a tourniquet (T/GA). The primary outcome was the change in the Oxford Knee Score (OKS) at 1 year postoperatively. Secondary outcomes included a satisfactory TKA outcome assessed using the OKS minimal important change (MIC) and OKS patient acceptable symptom state (PASS), adverse events, and quality of life using the 15-dimensional health-related quality of life tool. Results: At 1 year, the OKS was obtained for 381 patients. In the 2-group comparisons, the tourniquet did not affect the OKS improvement. The SA group had more substantial improvement in the OKS than the GA group (16.21 compared with 14.08 a mean difference of 2.13; 95% confidence interval [CI], 0.55 to 3.71; p = 0.008). In the 4-group comparisons, the T/SA group had more substantial improvements in the OKS than the NT/GA group (16.87 compared with 13.65, a mean difference of 3.2; 95% CI, 0.28 to 6.17; p = 0.026). The SA group reached the OKS MIC more frequently than the GA group (91.7% compared with 81.7%; odds ratio [OR] = 2.49 [95% CI, 1.32 to 4.69]; p = 0.005). The SA group also reached the OKS PASS more frequently than the GA group (86.0% compared with 75.7%; OR = 2.00 [95% CI, 1.18 to 3.39]; p = 0.010). The T/SA group had significantly more patients reaching the OKS MIC than the NT/GA group (95.7% compared with 79.6%; p = 0.005) and more patients reaching the OKS PASS than the NT/GA group (92.6% compared with 74.5%; p = 0.004). No differences were seen with respect to adverse events in any comparisons. Conclusions: The tourniquet had no detrimental effects on the outcomes of TKA. SA had a positive effect on the OKS. The use of SA combined with a tourniquet resulted in the best improvement in OKS and the highest proportion of satisfactory outcomes with TKA. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 16 May 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Classification of Electronic Health Record–Related Patient Safety Incidents: Development and Validation Study (Preprint)
BACKGROUND It is assumed that the implementation of health information technology introduces new vulnerabilities within a complex sociotechnical health care system, but no international consensus exists on a standardized format for enhancing the collection, analysis, and interpretation of technology-induced errors. OBJECTIVE This study aims to develop a classification for patient safety incident reporting associated with the use of mature electronic health records (EHRs). It also aims to validate the classification by using a data set of incidents during a 6-month period immediately after the implementation of a new EHR system. METHODS The starting point of the classification development was the Finnish Technology-Induced Error Risk Assessment Scale tool, based on research on commonly recognized error types. A multiprofessional research team used iterative tests on consensus building to develop a classification system. The final classification, with preliminary descriptions of classes, was validated by applying it to analyze EHR-related error incidents (n=428) during the implementation phase of a new EHR system and also to evaluate this classification’s characteristics and applicability for reporting incidents. Interrater agreement was applied. RESULTS The number of EHR-related patient safety incidents during the implementation period (n=501) was five-fold when compared with the preimplementation period (n=82). The literature identified new error types that were added to the emerging classification. Error types were adapted iteratively after several test rounds to develop a classification for reporting patient safety incidents in the clinical use of a high-maturity EHR system. Of the 427 classified patient safety incidents, interface problems accounted for 96 (22.5%) incident reports, usability problems for 73 (17.1%), documentation problems for 60 (14.1%), and clinical workflow problems for 33 (7.7%). Altogether, 20.8% (89/427) of reports were related to medication section problems, and downtime problems were rare (n=8). During the classification work, 14.8% (74/501) of reports of the original sample were rejected because of insufficient information, even though the reports were deemed to be related to EHRs. The interrater agreement during the blinded review was 97.7%. CONCLUSIONS This study presents a new classification for EHR-related patient safety incidents applicable to mature EHRs. The number of EHR-related patient safety incidents during the implementation period may reflect patient safety challenges during the implementation of a new type of high-maturity EHR system. The results indicate that the types of errors previously identified in the literature change with the EHR development cycle.
- 16 May 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessClassification of Electronic Health Record–Related Patient Safety Incidents: Development and Validation Study (Preprint)
BACKGROUND It is assumed that the implementation of health information technology introduces new vulnerabilities within a complex sociotechnical health care system, but no international consensus exists on a standardized format for enhancing the collection, analysis, and interpretation of technology-induced errors. OBJECTIVE This study aims to develop a classification for patient safety incident reporting associated with the use of mature electronic health records (EHRs). It also aims to validate the classification by using a data set of incidents during a 6-month period immediately after the implementation of a new EHR system. METHODS The starting point of the classification development was the Finnish Technology-Induced Error Risk Assessment Scale tool, based on research on commonly recognized error types. A multiprofessional research team used iterative tests on consensus building to develop a classification system. The final classification, with preliminary descriptions of classes, was validated by applying it to analyze EHR-related error incidents (n=428) during the implementation phase of a new EHR system and also to evaluate this classification’s characteristics and applicability for reporting incidents. Interrater agreement was applied. RESULTS The number of EHR-related patient safety incidents during the implementation period (n=501) was five-fold when compared with the preimplementation period (n=82). The literature identified new error types that were added to the emerging classification. Error types were adapted iteratively after several test rounds to develop a classification for reporting patient safety incidents in the clinical use of a high-maturity EHR system. Of the 427 classified patient safety incidents, interface problems accounted for 96 (22.5%) incident reports, usability problems for 73 (17.1%), documentation problems for 60 (14.1%), and clinical workflow problems for 33 (7.7%). Altogether, 20.8% (89/427) of reports were related to medication section problems, and downtime problems were rare (n=8). During the classification work, 14.8% (74/501) of reports of the original sample were rejected because of insufficient information, even though the reports were deemed to be related to EHRs. The interrater agreement during the blinded review was 97.7%. CONCLUSIONS This study presents a new classification for EHR-related patient safety incidents applicable to mature EHRs. The number of EHR-related patient safety incidents during the implementation period may reflect patient safety challenges during the implementation of a new type of high-maturity EHR system. The results indicate that the types of errors previously identified in the literature change with the EHR development cycle.
- 16 December 2008
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 53 (1) , 77-84
Topographic electroencephalogram in children during mask induction of anaesthesia with sevoflurane
Background: Epileptiform patterns, spikes, polyspikes and periodic epileptiform discharges (PED) have been reported in electroencephalograms (EEGs) during anaesthesia induction with sevoflurane in healthy adults and children. Published recordings have been performed with a limited number of channels, and therefore the topographic distributions of these patterns are not known. Methods: Twenty ASA I children aged 4–10 years undergoing routine operations were anaesthetized with 8% sevoflurane in 50%/50% oxygen and nitrous oxide using mask induction with controlled normoventilation. An EEG was recorded with a full 10–20 electrode system including orbitofrontal and ear electrodes, and a recording band of 0.016–70 Hz. Beat-to-beat heart rate (HR) was calculated off-line. Results: Nineteen out of 20 children developed multifocal spikes and polyspikes with a maximum over the frontal lobes. Four patients developed suppression, which was almost continuous and lasted several minutes, and thereafter a continuous EEG resumed, a few spikes were seen and then a nonepileptiform pattern. In three children a couple of PED waves were seen at the onset of a continuous EEG. HR increased maximally before the onset of spikes. No motor phenomena were seen. Conclusion: These recordings confirm the epileptogenic property of sevoflurane in mask induction. The spikes and polyspikes had frontal multifocal maxima and may be missed in recordings from frontopolar electrodes used by depth-of-anaesthesia monitors. PED and burst suppression were synchronous over the whole cortex. Epileptiform activity was indiscernible from epileptiform waveforms without anaesthesia, such as the patterns seen in status epilepticus.
- 16 December 2008
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 53 (1) , 77-84
Topographic electroencephalogram in children during mask induction of anaesthesia with sevoflurane
Background: Epileptiform patterns, spikes, polyspikes and periodic epileptiform discharges (PED) have been reported in electroencephalograms (EEGs) during anaesthesia induction with sevoflurane in healthy adults and children. Published recordings have been performed with a limited number of channels, and therefore the topographic distributions of these patterns are not known. Methods: Twenty ASA I children aged 4–10 years undergoing routine operations were anaesthetized with 8% sevoflurane in 50%/50% oxygen and nitrous oxide using mask induction with controlled normoventilation. An EEG was recorded with a full 10–20 electrode system including orbitofrontal and ear electrodes, and a recording band of 0.016–70 Hz. Beat-to-beat heart rate (HR) was calculated off-line. Results: Nineteen out of 20 children developed multifocal spikes and polyspikes with a maximum over the frontal lobes. Four patients developed suppression, which was almost continuous and lasted several minutes, and thereafter a continuous EEG resumed, a few spikes were seen and then a nonepileptiform pattern. In three children a couple of PED waves were seen at the onset of a continuous EEG. HR increased maximally before the onset of spikes. No motor phenomena were seen. Conclusion: These recordings confirm the epileptogenic property of sevoflurane in mask induction. The spikes and polyspikes had frontal multifocal maxima and may be missed in recordings from frontopolar electrodes used by depth-of-anaesthesia monitors. PED and burst suppression were synchronous over the whole cortex. Epileptiform activity was indiscernible from epileptiform waveforms without anaesthesia, such as the patterns seen in status epilepticus.