David M. Gaba
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David M. Gaba has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
David M.
Center for Immersive and Simulation-based Learning, Stanford School of Medicine, Stanford, CA ()
5 shared publications- Andrew Ames
Smithsonian Astrophysical Observatory, 60 Garden Street, Cambridge, Massachusetts 02138, USA
3 shared publications - Christina M Ignarra
SLAC National Accelerator Laboratory Palo Alto, CA United States
3 shared publications - Daniel S. Akerib
SLAC Natl Accelerator Lab, 2575 Sand Hill Rd, Menlo Pk, CA 94205 USA
3 shared publications - Eric Charles
SLAC National Accelerator Laboratory
3 shared publications - Martin Breidenbach
SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025, USA
3 shared publications
Latest Publications
- 7 October 2024
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 141 (5) , 819-821
The Many Worlds of Patient Safety in Anesthesiology
ANESTHESIOLOGY is the highest-impact, peer-reviewed medical journal that publishes trusted evidence that transforms the practice of perioperative,
- 7 October 2024
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 141 (5) , 819-821
The Many Worlds of Patient Safety in Anesthesiology
ANESTHESIOLOGY is the highest-impact, peer-reviewed medical journal that publishes trusted evidence that transforms the practice of perioperative,
- 22 September 2023
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 131 (5) , e157-e160
Screening for hazardous attitudes among anaesthesiologists: a pilot study
- 22 September 2023
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 131 (5) , e157-e160
Screening for hazardous attitudes among anaesthesiologists: a pilot study
- 5 June 2023
- Published by Elsevier in Anaesthesia Critical Care & Pain Medicine
- Vol. 42 (4) , 101263
New guidelines on human factors in critical situations should save lives, hearts, and brains
- 5 June 2023
- Published by Elsevier in Anaesthesia Critical Care & Pain Medicine
- Vol. 42 (4) , 101263
New guidelines on human factors in critical situations should save lives, hearts, and brains
- Open Access
- 5 August 2021
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 6 (3) , e26047
A Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing
Background: The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. Objective: We aimed to develop an acute shortage ventilator. Methods: The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. Results: The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. Conclusions: The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured.
- 5 August 2021
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 6 (3) , e26047
Open AccessA Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing
Background: The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. Objective: We aimed to develop an acute shortage ventilator. Methods: The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. Results: The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. Conclusions: The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured.
- Open Access
- 30 November 2020
- Published by JMIR Publications Inc. in JMIR Preprints
A Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing (Preprint)
BACKGROUND The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. OBJECTIVE We aimed to develop an acute shortage ventilator. METHODS The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. RESULTS The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. CONCLUSIONS The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured. CLINICALTRIAL
- 30 November 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessA Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing (Preprint)
BACKGROUND The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. OBJECTIVE We aimed to develop an acute shortage ventilator. METHODS The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. RESULTS The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. CONCLUSIONS The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured. CLINICALTRIAL
- Open Access
Acute Shortage Ventilator
We have implemented an “Acute Shortage Ventilator” (ASV) motivated by the COVID-19 pandemic and the possibility of severe ventilator shortages in the near future. The unit cost per ventilator is less than $400 US excluding the patient circuit parts. The ASV mechanically compresses a self-inflating bag resuscitator, uses a modified patient circuit, and is commanded by a microcontroller and an optional laptop. It operates in both Volume-Controlled Assist-Control mode and a Pressure-Controlled Assist-Control mode. It has been tested using an artificial lung against the EURS guidelines. The key design goals were to develop a simple device with high performance for short-term use, made primarily from common hospital parts and generally-available non-medical components, and at low cost and ease in manufacturing.
Open AccessAcute Shortage Ventilator
We have implemented an “Acute Shortage Ventilator” (ASV) motivated by the COVID-19 pandemic and the possibility of severe ventilator shortages in the near future. The unit cost per ventilator is less than $400 US excluding the patient circuit parts. The ASV mechanically compresses a self-inflating bag resuscitator, uses a modified patient circuit, and is commanded by a microcontroller and an optional laptop. It operates in both Volume-Controlled Assist-Control mode and a Pressure-Controlled Assist-Control mode. It has been tested using an artificial lung against the EURS guidelines. The key design goals were to develop a simple device with high performance for short-term use, made primarily from common hospital parts and generally-available non-medical components, and at low cost and ease in manufacturing.
- 1 April 2016
- Published by Wolters Kluwer Health in Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare
- Vol. 11 (2) , 71
Introduction to Special Issue on Highly Communicable Disease Management
- 1 April 2016
- Published by Wolters Kluwer Health in Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare
- Vol. 11 (2) , 71
Introduction to Special Issue on Highly Communicable Disease Management
- Open Access
- 1 February 2016
- Published by Wolters Kluwer Health in Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare
- Vol. 11 (1) , 19-24
Evaluating the Impact of Classroom Education on the Management of Septic Shock Using Human Patient Simulation
Classroom lectures are the mainstay of imparting knowledge in a structured manner and have the additional goals of stimulating critical thinking, lifelong learning, and improvements in patient care. The impact of lectures on patient care is difficult to examine in critical care because of the heterogeneity in patient conditions and personnel as well as confounders such as time pressure, interruptions, fatigue, and nonstandardized observation methods. The critical care environment was recreated in a simulation laboratory using a high-fidelity mannequin simulator, where a mannequin simulator with a standardized script for septic shock was presented to trainees. The reproducibility of this patient and associated conditions allowed the evaluation of “clinical performance” in the management of septic shock. In a previous study, we developed and validated tools for the quantitative analysis of house staff managing septic shock simulations. In the present analysis, we examined whether measures of clinical performance were improved in those cases where a lecture on the management of shock preceded a simulated exercise on the management of septic shock. The administration of the septic shock simulations allowed for performance measurements to be calculated for both medical interns and for subsequent management by a larger resident-led team. The analysis revealed that receiving a lecture on shock before managing a simulated patient with septic shock did not produce scores higher than for those who did not receive the previous lecture. This result was similar for both interns managing the patient and for subsequent management by a resident-led team. We failed to find an immediate impact on clinical performance in simulations of septic shock after a lecture on the management of this syndrome. Lectures are likely not a reliable sole method for improving clinical performance in the management of complex disease processes.
- 1 February 2016
- Published by Wolters Kluwer Health in Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare
- Vol. 11 (1) , 19-24
Open AccessEvaluating the Impact of Classroom Education on the Management of Septic Shock Using Human Patient Simulation
Classroom lectures are the mainstay of imparting knowledge in a structured manner and have the additional goals of stimulating critical thinking, lifelong learning, and improvements in patient care. The impact of lectures on patient care is difficult to examine in critical care because of the heterogeneity in patient conditions and personnel as well as confounders such as time pressure, interruptions, fatigue, and nonstandardized observation methods. The critical care environment was recreated in a simulation laboratory using a high-fidelity mannequin simulator, where a mannequin simulator with a standardized script for septic shock was presented to trainees. The reproducibility of this patient and associated conditions allowed the evaluation of “clinical performance” in the management of septic shock. In a previous study, we developed and validated tools for the quantitative analysis of house staff managing septic shock simulations. In the present analysis, we examined whether measures of clinical performance were improved in those cases where a lecture on the management of shock preceded a simulated exercise on the management of septic shock. The administration of the septic shock simulations allowed for performance measurements to be calculated for both medical interns and for subsequent management by a larger resident-led team. The analysis revealed that receiving a lecture on shock before managing a simulated patient with septic shock did not produce scores higher than for those who did not receive the previous lecture. This result was similar for both interns managing the patient and for subsequent management by a resident-led team. We failed to find an immediate impact on clinical performance in simulations of septic shock after a lecture on the management of this syndrome. Lectures are likely not a reliable sole method for improving clinical performance in the management of complex disease processes.
- 1 December 2014
- Published by Wolters Kluwer Health in Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare
- Vol. 9 (6) , 337-338
Simulation as a Critical Resource in the Response to Ebola Virus Disease
- 1 December 2014
- Published by Wolters Kluwer Health in Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare
- Vol. 9 (6) , 337-338
Simulation as a Critical Resource in the Response to Ebola Virus Disease
- Open Access
- 1 November 2013
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 117 (5) , 1033-1036
Perioperative Cognitive Aids in Anesthesia
- 1 November 2013
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 117 (5) , 1033-1036
Open AccessPerioperative Cognitive Aids in Anesthesia