JSJarupol Suriyawanakul

Jarupol Suriyawanakul

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jarupol Suriyawanakul has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Stress Distribution and Deformation of Maxillary Bilateral Distal-Extension Removable Partial Dentures with U-Shaped Palatal Major Connectors Fabricated from Different Materials: A Finite Element Analysis

    by Peerada Weerayutsil, Daraporn Sae-Lee, Jarupol Suriyawanakul, Pimduen Rungsiyakull, Pongsakorn Poovarodom

    Background/Objectives: This study aims to investigate the stress distribution and deformation of cobalt–chromium (CoCr) and polyetheretherketone (PEEK) maxillary bilateral distal-extension removable partial dentures (RPDs) on the abutment, periodontal ligament (PDL), mucosa, and RPD framework. Methods: A three-dimensional maxilla model was obtained from the patient’s cone-beam computed tomography (CBCT) and master model scan, composed of six maxillary anterior teeth, and U-shaped palatal major connectors for both the CoCr and PEEK RPD designs were constructed with computer-aided design (CAD) using the software program SolidWorks 2017 (SolidWorks Corp., Waltham, (MA), USA). A total vertical force of 320 N was applied bilaterally to the posterior artificial teeth. Three-dimensional finite element analysis was applied to evaluate the von Mises stress (VMS) distributions of the CoCr and PEEK RPDs on the abutment, PDL, mucosa, and RPD framework, and the deformation of the RPD framework was analyzed using ANSYS Workbench software, version 2020 (ANSYS Workbench 2020; ANSYS Inc.). Results: The stress distribution originated from the RPD free-end and was distributed to the mucosa, abutment, and PDL. The maximum stress observed in the oral structures was highest at the abutment, followed by the mucosa and PDL. The VMS occurring at the abutment in the CoCr RPD (9.098 MPa) was higher than that at the PEEK RPD (7.515 MPa), while the VMSs occurring at the mucosa and PDL in the CoCr RPD and PEEK RPD were similar. RPD frameworks constructed from different materials generated different stress distribution patterns. The maximum VMS occurring in the CoCr RPD framework (107.99 MPa) was significantly greater than that at the PEEK RPD framework (11.7 MPa). Meanwhile, the maximum deformation in the vertical direction of the PEEK RPD framework (0.0128 mm) was higher than that of the CoCr RPD framework (0.0082 mm). Conclusions: The results suggested that the PEEK RPD may have a better protective effect on the abutment. Both the PEEK and CoCr RPDs were unlikely to cause severe mechanical damage to the mucosa and PDL. However, the thickness of the PEEK framework should be focused on to reduce the stress distribution to the residual ridge mucosa.

  • Effect of customized abutment taper configuration on bone remodeling and peri‐implant tissue around implant‐supported single crown: A 3D nonlinear finite element study

    by Pongsakorn Poovarodom, Chaiy Rungsiyakull, Jarupol Suriyawanakul, Qing Li, Keiichi Sasaki, Nobuhiro Yoda, Pimduen Rungsiyakull

    Purpose: The optimal configuration of a customized implant abutment plays a crucial role in promoting bone remodeling and maintaining the peri‐implant gingival contour. However, the biomechanical effects of abutment configuration on bone remodeling and peri‐implant tissue remain unclear. This study aimed to evaluate the influence of abutment taper configurations on bone remodeling and peri‐implant tissue.Materials and methods: Five models with different abutment taper configurations (10°, 20°, 30°, 40°, and 50°) were analyzed using finite element analysis (FEA) to evaluate the biomechanical responses in peri‐implant bone and the hydrostatic pressure in peri‐implant tissue.Results: The results demonstrated that the rate of increase in bone density was similar in all models. On the other hand, the hydrostatic pressure in peri‐implant gingiva revealed significantly different results. Model 10° showed the highest maximum and volume‐averaged hydrostatic pressures (69.31 and 4.5 mmHg), whereas Model 30° demonstrated the lowest values (57.83 and 3.88 mmHg) with the lowest excessive pressure area. The area of excessive hydrostatic pressure decreased in all models as the degree of abutment taper increased from 10° to 30°. In contrast, Models 40° and 50° exhibited greater hydrostatic pressure concentration at the cervical region.Conclusion: In conclusion, the abutment taper configuration had a slight effect on bone remodeling but exerted a significant effect on the peri‐implant gingiva above the implant platform via hydrostatic pressure. Significant decreases in greatest and average hydrostatic pressures were observed in the peri‐implant tissues of Model 30°. However, the results indicate that implant abutment tapering wider than 40° could result in a larger area of excessive hydrostatic pressure in peri‐implant tissue, which could induce gingival recession.


  • Effect of gingival height of a titanium base on the biomechanical behavior of 2-piece custom implant abutments: A 3-dimensional nonlinear finite element study

    by Pongsakorn Poovarodom, Chaiy Rungsiyakull, Jarupol Suriyawanakul, Qing Li, Keiichi Sasaki, Nobuhiro Yoda, Pimduen Rungsiyakull


  • Open Access

    Possibility of Locking Compression Plate as the Treatment of External Fixation for Femoral Bone Based on Finite Element Method

    by Kriengkrai Nabudda, Jarupol Suriyawanakul, Kiatfa Tangchaichit, Weerachai Kosuwon, Kamolsak Sukhonthamarn, Nattadon Pannucharoenwong

  • Open Access

    Identification of Flexural Modulus and Poisson's Ratio of Fresh Femoral Bone Based on a Finite Element Model

    by Kriengkrai Nabudda, Jarupol Suriyawanakul, Kiatfa Tangchaichit, Nantiwat Pholdee, Weerachai Kosuwon, Taweechok Wisanuyotin, Kamolsak Sukhonthamarn

    Finite element analysis (FEA) is increasingly applied to medicine because it could increase accuracy and rapid outcomes. However, there is a lack of the method to determine Young's modulus and Poisson's ratio for fresh femoral bone and the mathematical principle's optimization for calculating nonuniform configuration. This study aimed to investigate the surrogate model for the optimization method to determine Young's modulus and Poisson's ratio of the fresh femoral bone. Young's modulus and Poisson's ratio obtained 20 ranked pairs by the Latin hypercube sampling method. The values were calculated in the finite element for root mean square error (RMSE) and were then used for solutions by a quadratic function, radial basis function (RBF), and Kriging (KG). The lowest RMSE value was 0.1518 for the RBF method, with the young's modulus at 304.4756 and the Poisson's ratio at 0.3334. The current study identified the RBF technique to determine the properties of the femoral bone. Moreover, the RBF procedure might apply to other long bones because of the comparable nonuniform configuration.


  • Open Access

    Decreasing turbulent helium flow in hard disk drive

    by Supitcha Tawinprai, Jarupol Suriyawanakul, Kiatfa Tangchaichit


  • Open Access

    Comparison of airflow-uniformity in different ceiling-diffuser designs with various concentric circles in shrimp freezer using CFD

    by Chanya Uraijaree, Kiatfa Tangchaichit, Jarupol Suriyawanakul

    This study presents airflow patterns in the air chamber of a shrimp freezer by using computational fluid dynamics (CFD) simulations made with SC/Tetra V.13 software. The quality of the product depends on the duration of the freezing time and airflow-uniformity. The objective of this study is to improve the airflow pattern by simulating and analyzing the airflow distribution in the air chamber of a shrimp freezer with different designs of ceiling diffuser, with various concentric circles. The results from the simulations show that the ceiling diffuser with 5 concentric circles improves airflow-uniformity at the outlet by 13.57% in SD compared to the original model, resulting in a reduced freezing time.

  • CFD Investigation of Damper Plate Effect on Air Flow in High Speed Rotation Hard Disk Drive by Using K-E with a Partial Model

    by Jarupol Suriyawanakul, Kiatfa Tangchaichit

    In HDD air flow simulation, the well known LES turbulent model requires large computing times and resources, including CPU, RAM and storage intensive which is not appropriate when using various variables. The effect of an air damper is studied by the k-e model with a reduced boundary due to the lower number of equations, computing time and computer resources. Firstly the RMS velocities of a partial model are compared between LES and k-e and then the reduced boundary models are compared with the partial model. The RMS velocity errors of the partial model compared with LES and k-e are less than 6 %. The mean RMS velocity errors compared with the reduced boundary model and the partial model are 3.93% at ID and 2.12% at MD position while the OD position increased to 26.5% because there is no effect from a return flow from the flex bracket and voice coil zone. Computing time of the reduced boundary and k-e model is reduced by 68.4%. In primary HDD air flow analysis, the k-e method together with a reduced model can be used to predict the effect of an air damper.


  • A Method to Reduce Calculation Time for a Study of a Damper Plate in a High Speed Hard Disk Drive Simulation

    by Jarupol Suriyawanakul, Kiatfa Tangchaichit

    The damper plate effect in a hard disk drive is studied using computational fluid dynamics technique. The well known Large Eddy Simulation technique needs high resources for computing power and time. This study presents a steady k-e turbulent model which needs lower resources but can predict the flow effect. The 3.5 inch hard disk drive is modeled with a hexahedral mesh for the computational domain. First, the RMS velocities of the model without damper plate and head stack assembly compared with LES and the transient k-e method are less than 6 %. After that, the damper plate is inserted into the model and the RMS velocity is compared using 4 methods which are LES, transient k-e, steady-transient k-e and steady k-e respectively. The results of k-e are very close to each other. The RMS velocity errors compared with LES rises up to 12.35-13.20 percent in the middle diameter zone, where there is an effect from diverted flow. The steady k-e provides a good computing time with 20 min/100 iterations and can show the trend of the damper plate effect which can be used usefully in future design work for various variables.