ABAnders Buen

Anders Buen

*This is an algorithmically generated author record based on publicly available information.

Anders Buen has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Double basses on the stage floor: Tuning fork–tabletop effect, or not?

    by Knut Guettler, Anders Askenfelt, Anders Buen

    The question whether or not double basses can benefit from a compliant and radiating stage floor in the low end of their tonal register, similar to the well-known tuning fork–tabletop effect, was examined through field experiments in five concert halls. The topic comprises several aspects: (1) How well the mechanical impedances of double basses and the stage floor match, (2) amount of vibration velocity transmitted to the floor through the end pin of the bass, and (3) radiation efficiency of point-excited bending waves in the stage floor far below the coincidence frequency. Each aspect represents a prerequisite for the tuning fork–tabletop effect to take place. The input impedance at the end pin was measured for three representative double basses. The stage floors of five orchestra halls were measured with respect input impedance and damping, while sound radiation to the audience area was measured for two of them. In Lindeman Hall, Oslo, all conditions for the tuning fork–tabletop effect to take place were clearly met. The contribution from the stage-floor radiation to the sound pressure level in the audience area was found to be about 5 dB between 40 and 60 Hz, and even higher between 30 and 40 Hz.


  • On the interaction between double basses and the stage floor

    by Knut Guettler, Anders Askenfelt, Anders Buen

    Double bassists unanimously claim the importance of a compliant stage floor for producing a warm and nuanced orchestrasound. However, in the limited number of reports studying the stage floor's contribution to radiated sound no clear conclusion has been reached. The present study, based on measurements of three concert halls and three double basses, points at some measurable features that should be considered when trying to settle the question: (1) With a compliant floor the velocity transfer between the bass bridge and floor is often higher than 0 dB in the low‐frequency range. In these cases the bass largely acts as a mass (viewed from the end pin) while the floor acts like a spring. (2) The floor properties affect the bridge mobility in the low‐frequency range. (3) Below the Helmholtz resonance, around 60 Hz, the radiation of the bass corpus falls about 40 dB within one octave while the ratio between the input power at the bridge and the power transferred to the floor via the end pin has been observed to boost from 3 to 40% in the same range. (4) The effect of a compliant floor may be more pronounced for the player than for the audience.


  • Simplified Room Acoustic Measurements

    by Tor Halmrast, Anders Buen

    Standardised room acousticmeasurements are needed for concert halls etc., but they imply heavy equipment. Thus, many interesting rooms are not measured. Most musicians (and even some acousticians) find that clapping and shouting in a room/hall might give an overview of the room acoustics. In the literature we even find that acoustic parameters are derived from scratchy recordings of music. Modern handheld high quality recording technology and possibilities of analysingsound files gives that one should investigate simpler (non standardised) measurements for simpler rooms/halls. This paper gives analysis of Impulse‐Responses recorded from balloons, paper bags, clapping, compared with measurements taken with more academic measurement equipment.