Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rola Muhammed Shadid has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Full-mouth rehabilitation with implant-supported overdentures in a heavy smoker with multiple sclerosis: A 3-year follow-up case report

    by Rola Muhammed Shadid

    This case report describes the rehabilitation of a 70-year-old Arab male patient with relapsing-remitting multiple sclerosis (MS), controlled type 2 diabetes, and heavy smoking. The patient was treated with a maxillary four-implant bar-supported overdenture and a mandibular two-implant tissue-supported overdenture chosen for their stability, minimal invasiveness, affordability, and ease of hygiene. At three-year follow-up, peri-implant bone levels remained stable, and function and quality of life improved. However, moderate inflammation and plaque accumulation reflected fair oral hygiene and persistent smoking. This case emphasizes the need for strict maintenance at three-month intervals and elimination of risk factors, particularly smoking and poor glycemic control. Implant therapy in MS patients should be undertaken cautiously with comprehensive risk assessment and interdisciplinary planning. Although this single case showed favorable outcomes, the findings should be interpreted with caution, given the persistent high-risk factors and limited generalizability.

  • Open Access

    Retention of CAD-CAM Implant-Supported Ceramic Restorations Luted to Titanium Bases: A Systematic Review of in-vitro Studies

    by Rola Muhammed Shadid

    This review aimed to compare the results of laboratory studies performed on adhesion methods of CAD-CAM implant-supported ceramic restorations to titanium-bases to analyze the factors that could affect this bond strength. The review was directed according to the guidelines delineated in the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Three databases including PubMed, Google Scholar, and Cochrane were investigated to identify related in vitro studies that mimicked clinical settings and published in international peer-reviewed journals between January 2000 and September 2024. The search yielded 5191 records; of these, 51 full-text articles were evaluated based on eligibility criteria. Ultimately, 31 studies were included. Different factors were assessed as possible influencers on ceramic/Ti-base bonding stability and strength. These include Ti-base height, different mechanical and chemical surface pretreatments of bonding surfaces, ceramic restoration material, luting system, and others. Ti-base abutment height is an important factor and thus it is recommended to use adequate Ti-base abutment height, whereas 3-mm-height should be used cautiously in posterior region. Combination of mechanical and chemical pretreatments of both bonding surfaces seems to enhance the bond strength; however, smooth Ti-bases rather than micro-grooved ones most likely benefit from sandblasting pretreatment. While the type of resin bonding system may affect the bonding performance, the interaction of some cements with definite ceramic materials could enhance the bond strength. The clinician must consider all those factors to have an effective bonding.


  • Open Access

    How Much is Stable the Bonding of CAD-CAM Implant-Supported All-Ceramic Restorations to Titanium Bases Clinically? A Systematic Review

    by Rola Muhammed Shadid

    The rapid advancement of digital technologies and the introduction of new ceramic materials have largely attributed to the notable transition from metal-ceramic to all-ceramic implant restorations bonded to Ti-bases. The purpose of this review was to evaluate all clinical studies reporting on the bond stability between CAD-CAM implant-supported all-ceramic restorations and Ti-bases. The review was directed according to the PRISMA guidelines to answer the focused question “How much is the stability and durability of the resin bond between implant-supported fixed CAD-CAM ceramic restorations and Ti- bases clinically?”. The PubMed, Google Scholar, and Cochrane databases were investigated to identify related clinical studies. Human studies assessing at least 10 patients restored with implant-supported fixed CAD-CAM ceramic restorations luted to prefabricated Ti-bases with a mean follow-up of at least 1 year and published in an English-language up to Sep. 2024 were included. The restorations could be single crown, fixed dental prosthesis, or full-arch fixed prosthesis. The search yielded 5,190 records; of these, 59 full-text articles were evaluated based on eligibility criteria. Ultimately, 40 studies were included. All 40 studies demonstrated low debonding rates from Ti-bases for single copings, multi-unit fixed dental prostheses, and full arch zirconia prostheses. Based on the limited evidence available, different factors were blamed for the debonding incidence, such as Ti-base height, geometry, luting agent, inadequacy of passive fit and biomechanical patient- and prosthesis-related factors. CAD-CAM implant-supported all-ceramic restorations bonded to Ti-bases demonstrated relatively high bond stability during observation period ranging from 1 to 7.5 years. More well-designed clinical research with long-term observation periods is highly recommended.


  • Open Access

    What Do Dental Students Know About E-Cigarettes? A Cross-Sectional Survey from One Palestinian Dental School

    by Rola Muhammed Shadid, Reeta Alsaeed

    Owing to the vital role played by dentists in patient education and due to the growing popularity of e-cigarette use among the younger population, this cross-sectional study aimed to assess the use, knowledge, beliefs, and attitudes toward e-cigarettes among dental students. A cross-sectional questionnaire was given between March and June of 2024 to undergraduate dental students in the Faculty of Dentistry at the Arab American University in Palestine. A 32-item questionnaire with five sections, namely demographics, smoking habits, knowledge, beliefs and attitude, and education about e-cigarettes was sent to all appropriate participants (N = 1050). The response rate was 31% (N = 325). About 11.7% of the respondents were current e-cigarette smokers. The two most commonly cited reasons for initial use of e-cigarettes were curiosity (52.8%) and a desire to quit conventional smoking (27.8%). The average knowledge score was 6.63 (3.08) out of 12, demonstrating a generally inadequate level of knowledge about e-cigarettes. Conventional cigarette smokers were more knowledgeable about e-cigarettes than non-smokers (OR = 1.928; 95% CI: 1.061–3.505; p-value = 0.031). The majority of students (92%) considered the level of education they received in the dental school about e-cigarettes as inadequate, and more than half (53.2%) received information from social media. In conclusion, the prevalence of e-cigarette use among Palestinian dental students is relatively high compared with that reported for other dental students worldwide. Since the students showed a generally inadequate level of knowledge about e-cigarettes, this study casts doubt on the competency of Palestinian dental students to offer cessation counseling, highlighting the necessity to revise the dental curricula to foster positive knowledge and belief conducive to ideal behaviors.


  • Open Access

    Knowledge, Opinions, and Practices of Oral Cancer Prevention among Palestinian Practicing Dentists: An Online Cross-Sectional Questionnaire

    by Rola Muhammed Shadid, Ghassan Habash

    Oral-health professionals play a critical role in the early recognition and prevention of oral cancer; however, most patients are diagnosed in the advanced stages that demonstrate poor prognosis. Therefore, this study aimed to investigate the knowledge, opinions, and clinical practices of practicing dentists related to oral cancer prevention and oral mucosal screening in Palestine. This research used an online cross-sectional questionnaire design. Practicing dentists in Palestine completed the 44-item questionnaire encompassing the following four sections: (a) personal data (6 items); (b) oral cancer knowledge (21 items); (c) opinions and beliefs related to oral cancer (10 items); and (d) clinical practices related to oral cancer (7 items). The questionnaire was sent to all eligible participants (N = 650) between July and September of 2022. The response rate was 39.1% (N = 254). About 70.1% of the respondents had poor knowledge of oral cancer and its risk factors, and almost 84.3% had positive opinions related to oral cancer prevention and oral mucosal screening. Concerning the clinical practices, only 29.9% routinely examined their patients every time their patients visited. More experienced dentists showed significantly more positive opinions and better clinical practices related to oral cancer prevention and screening; however, they had significantly lower knowledge scores compared with the younger dentists (p < 0.05). Inadequate training was the most reported perceived boundary against routine oral cancer screening. Palestinian dentists appeared to have positive opinions related to oral cancer prevention and oral mucosal screening. However, the assessment of the knowledge and clinical practices revealed deficiencies in this regard.


  • Open Access

    Comparing Dual-Zone Immediate Implant Placement and Socket Shield Technique for Ridge Width Changes in the Maxilla: A Prospective Cohort Study

    by Rola Muhammad Shadid

    Purpose: The aim of this prospective cohort study was to assess the facial-palatal ridge dimensional changes that occurred at 8-10 months following flapless dual-zone (DZ) immediate implant placement and socket-shield (SS) immediate placement in the maxilla. Materials and Methods: A total of 19 patients who received 20 implants were included, with 10 implants (MegaGen AnyRidge) placed for each treatment, DZ and SS. Cast models were made at 8-10 months after implant placement to assess the dimensional ridge changes by measuring the facial-palatal ridge width on implant sites (T) at six designated points starting from the gingival margin (0, 1, 2, 3, 5 and 7) and comparing it with the corresponding measurement on the contralateral tooth site (C). Results: All 20 implants demonstrated successful osseointegration at 8-10 months follow-up (survival rate 100%). Two out of ten cases of SS group presented with minor manageable complications of external shield exposure. DZ group showed an average of 0.3 mm facial-palatal ridge width reduction, while SS group revealed a mean gain in ridge width of approximately 0.2 mm at 8-10 months follow-up. Conclusion: When comparing between two treatments, there was a significant difference in ridge width change at 8-10 months following implant placement, indicating better preservation of the ridge contour for socket shield technique.


  • Open Access

    Knowledge, attitudes, and practices of oral cancer prevention among dental students and interns: an online cross‑sectional questionnaire in Palestine

    by Rola Muhammed Shadid, Mohammad Amid Abu Ali, Omar Kujan

    Background: Oral cancer is frequently characterized with an aggressive behavior and an unfavorable prognosis; however, it is generally associated with promising prognosis if detected early. Therefore, this study aimed to assess knowledge, practices, and attitudes toward oral cancer prevention among dental students and interns; and to investigate the factors that influence their practices of oral cancer screening or prevention. Material and methods: A cross-sectional questionnaire-based survey was conducted between March and April of 2022 on the fourth- and fifth-year undergraduate dental students and interns in the College of Dentistry at Arab American University in Palestine. A 48-item questionnaire which has 4 sections: demographics, knowledge, practices, and attitudes toward oral cancer prevention and early detection was sent to all eligible participants (N = 570). Results: The response rate was 68.7% (N = 351). About 66.8% of the respondents had poor knowledge about oral cancer and its risk factors, and 85.5% had a poor practice of oral cancer early detection and prevention; however, the majority of the respondents (81.1%) had shown favorable attitudes toward oral cancer prevention. Interns had significantly better knowledge and attitude scores compared to the undergraduate dental students (P < 0.05). Lack of training, time, confidence, and effectiveness were stated among the barriers to oral cancer screening. Conclusions: Most of the participants surveyed in this study appeared to lack adequate knowledge and skills in oral cancer prevention and early detection; however, they seemed to have good motivation and a good attitude toward oral cancer prevention training.


  • Open Access

    Immediate implant placement with socket shield technique in the maxilla: a prospective case series evaluation at 1-year follow-up

    by Rola Muhammed Shadid

    Background: The aims of this case series were to investigate the clinical, radiographic, implant success, complication incidence, esthetic, and patient-reported outcomes of 10 immediately placed implants associated with the socket shield technique at 12 months post-loading and to assess the ridge width changes that occurred at 8 months following implant placement.Methods: A total of 10 patients received 10 socket shield immediate implants (MegaGen AnyRidge). At 8 months postimplantation, casts were made to assess the ridge width changes by measuring the ridge width at the implant sites and comparing them with the corresponding measurements at the contralateral tooth site. At 12 months post-loading, clinical indices, marginal bone loss, pink esthetic score, and patient-assessed outcomes were evaluated. The mean, standard deviation and median were calculated for all continuous variables.Results: All implants demonstrated a 100% success rate, while 2 implants presented with external shield exposure that was managed successfully. The mean marginal bone loss was 0.08 ± 0.14 mm mesially and 0.21 ± 0.23 mm distally. Esthetic evaluation yielded an average modified pink esthetic score of 8.65. A mean gain of 0.17 mm in the facial-palatal ridge width was recorded at 8 months postimplantation.Conclusions: The socket shield technique enhanced the functional and esthetic results by preserving the alveolar bone and peri-implant soft tissues. However, this is a sensitive technique and still needs more robust evidence before it can be recommended for everyday clinical practice.


  • Open Access

    Socket shield technique and delayed implant placement in maxilla: a series of five case reports

    by Rola Muhammed Shadid

    Background: Tooth extraction is often followed by remodeling of hard and soft tissues, while socket shield technique has been proposed to prevent or minimize this remodeling. Socket shield accompanied with delayed implant placement is a novel technique that could be used when delayed implantation is selected; however, more scientific based evidence is required to recommend this technique as everyday clinical practice. Thus, the aim of this case series was to assess the clinical, radiographic, and esthetic outcomes of the delayed placed implants associated with previously prepared socket shield at 3–15 months follow-up after loading. The stability of the shield and the depth of soft tissue penetration palatal to the shield at reentry of 3–6 months were also assessed. Cases presentation: Five case reports of socket shield with delayed implant placement were described in the study. The facial shields were prepared and simultaneously the sockets were grafted with mineralized allograft particles, then the implants were placed 3–6 months later. Periodontal probe was used to measure the depth of soft tissue penetration palatal to the shield at reentry. Clinical indices of bleeding index, plaque index, and probing depths were recorded. Radiographic evaluation to record the amount of marginal bone loss post-loading, esthetic assessment using modified pink esthetic score, and patient assessed outcomes were also evaluated at 3–15 months follow-up after loading. At 3–6 months reentry, all shields were stable with maintenance of the facial bone and with extreme hard tissue formation in the sockets. All five implants were successful and functional without any pain or inflammation, with optimal soft tissue health and esthetics, and with minimal radiographic marginal bone loss at the last follow-up visit (3–15 months after loading). Conclusions: Within the limits of this study, socket shield technique with delayed implant placement could be a predictable minimally invasive option for cases requiring delayed implant placement; however, a long-term well-designed clinical proof is warranted.


  • Open Access

    Comparing Dual-zone Immediate Implant Placement and Socket-shield Technique for Ridge Width Changes in Maxilla: a Prospective Cohort Study

    by Rola Shadid

    Background: The socket-shield technique still requires more scientific based evidence to be recommended as everyday clinical practice, the aim of this prospective cohort study was to assess the facial-palatal ridge dimensional changes that occurred after a minimum of 8 months following flapless dual-zone (DZ) immediate implant placement and socket-shield (SS) immediate placement in the maxilla.Methods: A total of 19 patients who received 20 implants were included with 10 implants (MegaGen AnyRidge) were placed for each treatment, DZ and SS. Cast models were made at least 8 months after implant placement to assess the dimensional ridge changes by measuring the facial palatal ridge width on implant sites (T) at six designated points starting from gingival margin (0, 1, 2, 3, 5 and 7) and comparing it with the corresponding measurement on contralateral tooth site (C). Results: All 20 placed implants demonstrated successful osseointegration and survived 9-24 months following implantation (survival rate 100%). Two out of ten cases of SS group presented with minor manageable complications of external shield exposure. DZ group showed an average facial-palatal reduction of nearly 0.3 mm; however, there were no significant differences between T and C (P =.47), while SS group revealed a mean gain in ridge contour of approximately 0.2 mm with also no significant differences existed between T and C (P = .64) in the 8-months follow-up. When comparing between the two treatments, there were significant differences in ridge width changes (P < .05), indicating better preservation of the ridge contour at 8-months for SS treatment.Conclusion: The socket shield immediate implant placement produced better preservation of the ridge contour at 8-months post-extraction; however, the dual-zone technique yielded non clinically significant reduction in the ridge contour at the same follow-up.