Krystian Wróbel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Krystian Wróbel has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Maciej Szkulmowski
Nicolaus Copernicus University in Torun
3 shared publications Szymon Tamborski
3 shared publications- Maciej M. Bartuzel
Center for Human Ophthalmic Imaging Research (CHOIR) UC Davis Eye Center, Sacramento, CA 95817, USA
2 shared publications Maciej Szkulmowski
2 shared publications- Michał Meina
Nicolaus Copernicus University in Torun
2 shared publications Anna Szkulmowska
AM2M Ltd LP, Mickiewicza 7-17, PL-87100 Torun, Poland
1 shared publication
Latest Publications
- Open Access
- 23 December 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (1) , 015005
Comparative analysis of retinal and cerebral vascular responses to CO₂ using Doppler optical coherence tomography and transcranial Doppler ultrasound
Objective. Access to blood flow data in cerebral and retinal vascular beds is crucial for diagnosing cerebrovascular diseases. This study addresses two technological gaps: (1) simultaneous recording of vascular responses in the brain and eye by integrating transcranial Doppler ultrasonography (TCD) with Doppler optical coherence tomography (DOCT); (2) automation of DOCT image processing, including vessel segmentation, to enable quantification of flow in small retinal vessels as a proxy for cerebral microcirculation. The research evaluates vascular reactivity to CO₂ changes, measuring pulsatility index (PI), resistive index (RI), and systolic/diastolic ratio (S/D). Approach. Ten healthy volunteers were recruited. Blood flow was simultaneously recorded in the middle cerebral artery (MCA) using TCD and in retinal microarteries and microveins (diameters 50–130 µ m) using DOCT (95 Hz sampling rate). A novel software framework was developed for automated DOCT analysis: B-scan preprocessing, alignment, vessel segmentation, filtering, and extraction of parameters (area, lumen diameter, axial velocity component). Data were analyzed across cardiac phases (S/D) during normal breathing, apnea, and hyperventilation. Correlations were assessed statistically, comparing velocity changes and vascular indices. Main results. In the MCA, significant correlations were observed between flow velocity changes and breathing tests (increase during apnea, decrease during hyperventilation; p < 0.01). Retinal vessels showed no statistically significant correlations ( p > 0.05), despite DOCT enabling precise measurement of PI, RI, and S/D comparable to TCD. Retinal vessels exhibited lower CO₂ reactivity, confirming fundamental differences in ocular and cerebral microcirculation regulation. Significance. TCD-DOCT integration enables noninvasive, synchronized vascular reactivity assessment, paving the way for studies on brain-eye microcirculation interactions. Results in healthy subjects highlight retinal vessels’ uniqueness as a model but indicate limitations in directly mirroring cerebral changes, guiding future hybrid protocols. The automated framework eliminates subjective errors, facilitating scalable clinical analyses in pathologies like ischemic stroke or cerebral small vessel disease.
- 23 December 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (1) , 015005
Open AccessComparative analysis of retinal and cerebral vascular responses to CO₂ using Doppler optical coherence tomography and transcranial Doppler ultrasound
Objective. Access to blood flow data in cerebral and retinal vascular beds is crucial for diagnosing cerebrovascular diseases. This study addresses two technological gaps: (1) simultaneous recording of vascular responses in the brain and eye by integrating transcranial Doppler ultrasonography (TCD) with Doppler optical coherence tomography (DOCT); (2) automation of DOCT image processing, including vessel segmentation, to enable quantification of flow in small retinal vessels as a proxy for cerebral microcirculation. The research evaluates vascular reactivity to CO₂ changes, measuring pulsatility index (PI), resistive index (RI), and systolic/diastolic ratio (S/D). Approach. Ten healthy volunteers were recruited. Blood flow was simultaneously recorded in the middle cerebral artery (MCA) using TCD and in retinal microarteries and microveins (diameters 50–130 µ m) using DOCT (95 Hz sampling rate). A novel software framework was developed for automated DOCT analysis: B-scan preprocessing, alignment, vessel segmentation, filtering, and extraction of parameters (area, lumen diameter, axial velocity component). Data were analyzed across cardiac phases (S/D) during normal breathing, apnea, and hyperventilation. Correlations were assessed statistically, comparing velocity changes and vascular indices. Main results. In the MCA, significant correlations were observed between flow velocity changes and breathing tests (increase during apnea, decrease during hyperventilation; p < 0.01). Retinal vessels showed no statistically significant correlations ( p > 0.05), despite DOCT enabling precise measurement of PI, RI, and S/D comparable to TCD. Retinal vessels exhibited lower CO₂ reactivity, confirming fundamental differences in ocular and cerebral microcirculation regulation. Significance. TCD-DOCT integration enables noninvasive, synchronized vascular reactivity assessment, paving the way for studies on brain-eye microcirculation interactions. Results in healthy subjects highlight retinal vessels’ uniqueness as a model but indicate limitations in directly mirroring cerebral changes, guiding future hybrid protocols. The automated framework eliminates subjective errors, facilitating scalable clinical analyses in pathologies like ischemic stroke or cerebral small vessel disease.
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 73
Zero-latency retinal movement tracker with high spatial and temporal resolution
SPIE Digital Library Proceedings
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 73
Zero-latency retinal movement tracker with high spatial and temporal resolution
SPIE Digital Library Proceedings
- Open Access
- 1 October 2020
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 133
Spectral and time domain optical coherence spectroscopy
- 1 October 2020
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 133
Open AccessSpectral and time domain optical coherence spectroscopy
- 19 May 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (6) , 3164-3180
High-resolution, ultrafast, wide-field retinal eye-tracking for enhanced quantification of fixational and saccadic motion
We introduce a novel, noninvasive retinal eye-tracking system capable of detecting eye displacements with an angular resolution of 0.039 arcmin and a maximum velocity of 300°/s across an 8° span. Our system is designed based on a confocal retinal imaging module similar to a scanning laser ophthalmoscope. It utilizes a 2D MEMS scanner ensuring high image frame acquisition frequencies up to 1.24 kHz. In contrast with leading eye-tracking technology, we measure the eye displacements via the collection of the observed spatial excursions for all the times corresponding a full acquisition cycle, thus obviating the need for both a baseline reference frame and absolute spatial calibration. Using this approach, we demonstrate the precise measurement of eye movements with magnitudes exceeding the spatial extent of a single frame, which is not possible using existing image-based retinal trackers. We describe our retinal tracker, tracking algorithms and assess the performance of our system by using programmed artificial eye movements. We also demonstrate the clinical capabilities of our system with in vivo subjects by detecting microsaccades with angular extents as small as 0.028°. The rich kinematic ocular data provided by our system with its exquisite degree of accuracy and extended dynamic range opens new and exciting avenues in retinal imaging and clinical neuroscience. Several subtle features of ocular motion such as saccadic dysfunction, fixation instability and abnormal smooth pursuit can be readily extracted and inferred from the measured retinal trajectories thus offering a promising tool for identifying biomarkers of neurodegenerative diseases associated with these ocular symptoms.
- 19 May 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (6) , 3164-3180
High-resolution, ultrafast, wide-field retinal eye-tracking for enhanced quantification of fixational and saccadic motion
We introduce a novel, noninvasive retinal eye-tracking system capable of detecting eye displacements with an angular resolution of 0.039 arcmin and a maximum velocity of 300°/s across an 8° span. Our system is designed based on a confocal retinal imaging module similar to a scanning laser ophthalmoscope. It utilizes a 2D MEMS scanner ensuring high image frame acquisition frequencies up to 1.24 kHz. In contrast with leading eye-tracking technology, we measure the eye displacements via the collection of the observed spatial excursions for all the times corresponding a full acquisition cycle, thus obviating the need for both a baseline reference frame and absolute spatial calibration. Using this approach, we demonstrate the precise measurement of eye movements with magnitudes exceeding the spatial extent of a single frame, which is not possible using existing image-based retinal trackers. We describe our retinal tracker, tracking algorithms and assess the performance of our system by using programmed artificial eye movements. We also demonstrate the clinical capabilities of our system with in vivo subjects by detecting microsaccades with angular extents as small as 0.028°. The rich kinematic ocular data provided by our system with its exquisite degree of accuracy and extended dynamic range opens new and exciting avenues in retinal imaging and clinical neuroscience. Several subtle features of ocular motion such as saccadic dysfunction, fixation instability and abnormal smooth pursuit can be readily extracted and inferred from the measured retinal trajectories thus offering a promising tool for identifying biomarkers of neurodegenerative diseases associated with these ocular symptoms.
- Open Access
- 22 April 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11359, 113590Q
Blood flow rate estimation in optic disc capillaries and vessels using Doppler optical coherence tomography
The volumetric flow rate contains useful information in ophthalmology. According to a recent study, quantitative blood flow could be applied in the diagnosis of common civilization diseases such as diabetic retinopathy, Alzheimer's disease and macular degeneration. Non-invasive optical methods as Doppler optical coherence tomography can be used to calculate the blood flow, but have some limitations. One of the problems is phase wrapping that makes impossible to calculate the flow in the full range of retinal vessels diameters. We demonstrate that Doppler OCT and more specifically the joint Spectral and Time domain Optical Coherence Tomography method (STdOCT) combined with three-dimensional fast phase unwrapping method (3D 4FT FPU) allows for fast calculation of blood flow rate in human optic disc area for capillaries and vessels with diameters in the range of 12-180 μm. All data processing including raw spectral domain OCT data set to complex tomograms processing (1024×1024×256 pixels), Doppler OCT processing and 3D 4FT FPU unwrapping was processed in GPU in time 1 s or 27 s for standard Doppler OCT and STdOCT, respectively. Unwrapped axial velocities of flow were obtained for all vessels in the 3D data set at the same time. The ability to calculate blood flow rate is proven on a microfluidic device with controlled flow and on arteriole bifurcations in data acquired form five healthy subjects. The additive character of flow within human retinal vessels, as well as parabolic relation between flow and vessel diameter, are shown.
- 22 April 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11359, 113590Q
Open AccessBlood flow rate estimation in optic disc capillaries and vessels using Doppler optical coherence tomography
The volumetric flow rate contains useful information in ophthalmology. According to a recent study, quantitative blood flow could be applied in the diagnosis of common civilization diseases such as diabetic retinopathy, Alzheimer's disease and macular degeneration. Non-invasive optical methods as Doppler optical coherence tomography can be used to calculate the blood flow, but have some limitations. One of the problems is phase wrapping that makes impossible to calculate the flow in the full range of retinal vessels diameters. We demonstrate that Doppler OCT and more specifically the joint Spectral and Time domain Optical Coherence Tomography method (STdOCT) combined with three-dimensional fast phase unwrapping method (3D 4FT FPU) allows for fast calculation of blood flow rate in human optic disc area for capillaries and vessels with diameters in the range of 12-180 μm. All data processing including raw spectral domain OCT data set to complex tomograms processing (1024×1024×256 pixels), Doppler OCT processing and 3D 4FT FPU unwrapping was processed in GPU in time 1 s or 27 s for standard Doppler OCT and STdOCT, respectively. Unwrapped axial velocities of flow were obtained for all vessels in the 3D data set at the same time. The ability to calculate blood flow rate is proven on a microfluidic device with controlled flow and on arteriole bifurcations in data acquired form five healthy subjects. The additive character of flow within human retinal vessels, as well as parabolic relation between flow and vessel diameter, are shown.