Muhammad Thahiruddin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Muhammad Thahiruddin has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Adhi Nugraha
Universitas Muhammadiyah Malang
1 shared publication Alfie Nuril Mustofa
Department of Mathematics, Universitas Annuqayah, Sumenep, Jawa Timur, Indonesia
1 shared publication- Anisah Anisah1 shared publication
B. Widodo
1 shared publicationBasuki Widodo
1 shared publicationC. Imron
Department of Mathematics, Faculty of Mathematics, Computing and Data Sciences, Institut Teknologi Sepuluh Nopember, Surabaya 60111, Indonesia
1 shared publication
Latest Publications
- 18 October 2026
- Published by SAGE Publications in Ultrasonic Imaging
MTL-LymphNet: A Lightweight Multi-Task Learning Framework for Simultaneous Lymph Node Segmentation and Metastasis Classification in Thyroid Cancer Ultrasound
Ultrasound assessment of cervical lymph node metastasis in papillary thyroid carcinoma is crucial but suffers from inter-observer variability. Existing deep learning solutions typically use separate single-task pipelines, resulting in parameter redundancy. We propose MTL-LymphNet, a lightweight, backbone-agnostic multi-task learning framework that simultaneously segments lymph nodes and classifies metastasis within a single forward pass, evaluated across 3 backbones and 4 loss weighting strategies. On 338 images from 2 independent clinical centers, MTL-LymphNet achieved an internal cross-validation Dice coefficient of 0.891 ± 0.022 and AUC of 0.948 ± 0.027. Bidirectional external validation revealed substantial domain shift, with cross-center Dice of 0.865 and 0.779, and AUC of 0.733 and 0.830. The multi-task configuration offered a favorable efficiency–performance trade-off (∆Dice = Δ , − 0 . 014 , P < .0001) for 40% fewer parameters than separate models. No backbone or weighting strategy consistently dominated, and calibration degraded substantially under domain shift (ECE: 0.049 internally vs 0.178-0.304 externally), requiring center-specific recalibration before clinical use. To our knowledge, this is the first MTL framework for cervical lymph node analysis with bidirectional multi-center validation and systematic ablation. With a compact size of 22.6 to 29.1 MB and CPU inference of 81 to 131 ms, MTL-LymphNet demonstrates technical feasibility as a CAD tool warranting prospective validation.
- 18 October 2026
- Published by SAGE Publications in Ultrasonic Imaging
MTL-LymphNet: A Lightweight Multi-Task Learning Framework for Simultaneous Lymph Node Segmentation and Metastasis Classification in Thyroid Cancer Ultrasound
Ultrasound assessment of cervical lymph node metastasis in papillary thyroid carcinoma is crucial but suffers from inter-observer variability. Existing deep learning solutions typically use separate single-task pipelines, resulting in parameter redundancy. We propose MTL-LymphNet, a lightweight, backbone-agnostic multi-task learning framework that simultaneously segments lymph nodes and classifies metastasis within a single forward pass, evaluated across 3 backbones and 4 loss weighting strategies. On 338 images from 2 independent clinical centers, MTL-LymphNet achieved an internal cross-validation Dice coefficient of 0.891 ± 0.022 and AUC of 0.948 ± 0.027. Bidirectional external validation revealed substantial domain shift, with cross-center Dice of 0.865 and 0.779, and AUC of 0.733 and 0.830. The multi-task configuration offered a favorable efficiency–performance trade-off (∆Dice = Δ , − 0 . 014 , P < .0001) for 40% fewer parameters than separate models. No backbone or weighting strategy consistently dominated, and calibration degraded substantially under domain shift (ECE: 0.049 internally vs 0.178-0.304 externally), requiring center-specific recalibration before clinical use. To our knowledge, this is the first MTL framework for cervical lymph node analysis with bidirectional multi-center validation and systematic ablation. With a compact size of 22.6 to 29.1 MB and CPU inference of 81 to 131 ms, MTL-LymphNet demonstrates technical feasibility as a CAD tool warranting prospective validation.
- Open Access
- 20 March 2026
- Published by Elsevier in SSRN Electronic Journal
Comparative Evaluation of Lightweight Deep Learning Architectures for Indonesian Medicinal Plant Classification
Accurate identification of medicinal plants is essential for traditional medicine practices, biodiversity conservation, and pharmaceutical research in Indonesia. However, manual identification requires expert knowledge and is prone to human error. This study presents a comprehensive evaluation of five state-of-the-art deep learning architectures for automated classification of 100 Indonesian medicinal plant species based on digital images. We evaluated ConvNeXt-Base, GhostNetV3, RepViT-M2, EfficientFormerV2-S1, and TinyViT-5M using a dataset of 10,000 leaf images with rigorous 5-fold stratified cross-validation. The experimental results demonstrate that ConvNeXt-Base achieved the highest classification accuracy of 97.07% with an F1-score of 97.04% and ROC-AUC of 99.88%. For resource-constrained edge deployment, TinyViT-5M emerged as the optimal choice, achieving 94.73% accuracy with only 5.10 million parameters and 8.66 ms GPU latency, representing the best accuracy-efficiency trade-off among lightweight models. Statistical analysis using the Friedman test confirmed significant differences between model performances (p-value = 0.00227). This study provides valuable insights for deploying deep learning-based medicinal plant identification systems on mobile and embedded devices, supporting traditional medicine practices, agricultural extension services, and biodiversity documentation in Indonesia.
- 20 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessComparative Evaluation of Lightweight Deep Learning Architectures for Indonesian Medicinal Plant Classification
Accurate identification of medicinal plants is essential for traditional medicine practices, biodiversity conservation, and pharmaceutical research in Indonesia. However, manual identification requires expert knowledge and is prone to human error. This study presents a comprehensive evaluation of five state-of-the-art deep learning architectures for automated classification of 100 Indonesian medicinal plant species based on digital images. We evaluated ConvNeXt-Base, GhostNetV3, RepViT-M2, EfficientFormerV2-S1, and TinyViT-5M using a dataset of 10,000 leaf images with rigorous 5-fold stratified cross-validation. The experimental results demonstrate that ConvNeXt-Base achieved the highest classification accuracy of 97.07% with an F1-score of 97.04% and ROC-AUC of 99.88%. For resource-constrained edge deployment, TinyViT-5M emerged as the optimal choice, achieving 94.73% accuracy with only 5.10 million parameters and 8.66 ms GPU latency, representing the best accuracy-efficiency trade-off among lightweight models. Statistical analysis using the Friedman test confirmed significant differences between model performances (p-value = 0.00227). This study provides valuable insights for deploying deep learning-based medicinal plant identification systems on mobile and embedded devices, supporting traditional medicine practices, agricultural extension services, and biodiversity documentation in Indonesia.
- 1 June 2020
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2242 (1) , 030027
Unsteady magnetohydrodynamics of nano fluid over porous sliced magnetic sphere
There have been many studies that consider the effect of mixed convection on nanofluid that passes a magnetic object or not, whether it is a flat plate, solid sphere, or porous sphere. The implementation of those problems can be found in engineering and industrial fields such as nuclear reactors, pistons, oil drilling, chemical piping in factories and propulsion on ships. However, it has never been studied about object with magnetic sliced porous sphere. Therefore, we consider the effect of magnetic, porosity and slicing angle parameters towards velocity and temperature profiles of nanofluids when passes porous sliced magnetic sphere problem. Therefore, we develop mathematical model of the problem that consists of continuity equation, momentum equation and dimensional energy equation. Furthermore, Keller-Box method is used to solved the problem numerically. From the simulation, we obtain that the velocity of nanofluid flow become slower when magnetic parameter increases and the temperature of nanofluid flow become lower when the magnetic parameter increases. For porosity parameter, we obtain that with a greater porosity parameter value, the velocity of fluid flow is slower and the temperature of fluid is lower. For Slicing angle, we obtain that the velocity of the fluid increases with increasing slicing angle while the fluid temperature decreases.
- 1 June 2020
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2242 (1) , 030027
Unsteady magnetohydrodynamics of nano fluid over porous sliced magnetic sphere
There have been many studies that consider the effect of mixed convection on nanofluid that passes a magnetic object or not, whether it is a flat plate, solid sphere, or porous sphere. The implementation of those problems can be found in engineering and industrial fields such as nuclear reactors, pistons, oil drilling, chemical piping in factories and propulsion on ships. However, it has never been studied about object with magnetic sliced porous sphere. Therefore, we consider the effect of magnetic, porosity and slicing angle parameters towards velocity and temperature profiles of nanofluids when passes porous sliced magnetic sphere problem. Therefore, we develop mathematical model of the problem that consists of continuity equation, momentum equation and dimensional energy equation. Furthermore, Keller-Box method is used to solved the problem numerically. From the simulation, we obtain that the velocity of nanofluid flow become slower when magnetic parameter increases and the temperature of nanofluid flow become lower when the magnetic parameter increases. For porosity parameter, we obtain that with a greater porosity parameter value, the velocity of fluid flow is slower and the temperature of fluid is lower. For Slicing angle, we obtain that the velocity of the fluid increases with increasing slicing angle while the fluid temperature decreases.
- Open Access
- 1 March 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1490 (1)
Numerical Solution of Unsteady A12O3 -Water Nanofluid Flow Past A Magnetic Porous Sliced Sphere
This study aims to investigate the MHD stagnation point flow of Al2O3 -Water nanofluid with mixed convection effect pass a sliced magnetic porous sphere. The unsteady Al2 O3 -Water nanofluid mixed convection boundary layer flows the stagnation point is an interesting study. This implementation of this concept can use in the problems of engineering and industrial fields such as propulsion ships system, oil drilling, chemical piping, and nuclear reactor coolant. In this paper, we consider the effect of magnetic, porosity, and slicing angel parameters towards the velocity and temperature profiles. We construct a mathematical model of MHD flow in Al2O3 -Water nanofluid to obtain dimensional governing equations. Then, the equations converted into non-dimensional equations by using non-dimensional variables and unsimilarity equations using stream function. The solution of the model solved by numerically using the Keller-Box scheme. The velocity and temperature profiles are determined for various non-dimensional parameters such as magnetic parameter, sliced angle, and porosity parameter. We obtain that the velocity of Al2O3 -Water nanofluid decreases but the temperature decreases when magnetic parameters increases. For the porosity parameter increases then the velocity of the fluid decreases but the temperature of the fluid increases. For the sliced angle parameter increases then the velocity of the fluid increases but temperature of the fluid decrease. For the volume fraction parameter increases then the fluid velocity decreaes but the fluid temperature increases.
- 1 March 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1490 (1)
Open AccessNumerical Solution of Unsteady A12O3 -Water Nanofluid Flow Past A Magnetic Porous Sliced Sphere
This study aims to investigate the MHD stagnation point flow of Al2O3 -Water nanofluid with mixed convection effect pass a sliced magnetic porous sphere. The unsteady Al2 O3 -Water nanofluid mixed convection boundary layer flows the stagnation point is an interesting study. This implementation of this concept can use in the problems of engineering and industrial fields such as propulsion ships system, oil drilling, chemical piping, and nuclear reactor coolant. In this paper, we consider the effect of magnetic, porosity, and slicing angel parameters towards the velocity and temperature profiles. We construct a mathematical model of MHD flow in Al2O3 -Water nanofluid to obtain dimensional governing equations. Then, the equations converted into non-dimensional equations by using non-dimensional variables and unsimilarity equations using stream function. The solution of the model solved by numerically using the Keller-Box scheme. The velocity and temperature profiles are determined for various non-dimensional parameters such as magnetic parameter, sliced angle, and porosity parameter. We obtain that the velocity of Al2O3 -Water nanofluid decreases but the temperature decreases when magnetic parameters increases. For the porosity parameter increases then the velocity of the fluid decreases but the temperature of the fluid increases. For the sliced angle parameter increases then the velocity of the fluid increases but temperature of the fluid decrease. For the volume fraction parameter increases then the fluid velocity decreaes but the fluid temperature increases.