M. Kočan
Research Subjects
M. Kočan has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
E. Gauthier
CEA, IRFM, F-13108 Saint-Paul-lez-Durance, France
2 shared publicationsG. Bonhomme
Nancy Université, BP 239, 54506 Vandoeuvre-lès-Nancy cedex, France
2 shared publicationsJ.-Y. Pascal
CEA, IRFM, F-13108 Saint-Paul-lez-Durance, France
2 shared publicationsB. Pegourie
CEA, IRFM, F-13108 Saint-Paul-lez-Durance, France
1 shared publicationI. Ďuran
Institute of Plasma Physics, Association EURATOM/IPP.CR, Prague 18200, Czech Republic
1 shared publicationJ. P. Gunn
IRFM 1 CEA F-13108 Saint-Paul-lez-Durance, France
1 shared publication
Latest Publications
- 15 June 2009
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 390-391, 1074-1077
Measurements of scrape-off layer ion-to-electron temperature ratio in Tore Supra ohmic plasmas
- 15 June 2009
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 390-391, 1074-1077
Measurements of scrape-off layer ion-to-electron temperature ratio in Tore Supra ohmic plasmas
- 1 July 2008
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 79 (7) , 073502
On the reliability of scrape-off layer ion temperature measurements by retarding field analyzers
The retarding field analyzer (RFA) is one of the only widely accepted diagnostics for measurements of ion temperature Ti in the tokamak scrape-off layer. In this paper we analyze some instrumental effects of the RFA and their influence on Ti measurements. It is shown that selective ion transmission through the RFA slit is responsible for an overestimation of Ti by less than 14%, even for a relatively thick slit plate. Therefore, thicker slit plates are preferable, since they reduce, e.g., the risk of melting during off-normal events, and the effect of positive space charge inside the cavity. The influence of the electron repelling grid, as well as misalignment of the slit with respect to the magnetic field on Ti measurements are negligible.
- 1 July 2008
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 79 (7) , 073502
On the reliability of scrape-off layer ion temperature measurements by retarding field analyzers
The retarding field analyzer (RFA) is one of the only widely accepted diagnostics for measurements of ion temperature Ti in the tokamak scrape-off layer. In this paper we analyze some instrumental effects of the RFA and their influence on Ti measurements. It is shown that selective ion transmission through the RFA slit is responsible for an overestimation of Ti by less than 14%, even for a relatively thick slit plate. Therefore, thicker slit plates are preferable, since they reduce, e.g., the risk of melting during off-normal events, and the effect of positive space charge inside the cavity. The influence of the electron repelling grid, as well as misalignment of the slit with respect to the magnetic field on Ti measurements are negligible.