Graziano Montaruli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Graziano Montaruli has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Michele Tepedino
Department of Biotechnological and Applied Clinical Sciences, University of L’Aquila, 67100 L’Aquila, Italy
10 shared publications - Lorenzo Lo Muzio
Department of Clinical and Experimental Medicine, University of Foggia, 71122 Foggia, Italy
9 shared publications - Michele Laurenziello
Department of Clinical and Experimental Medicine, University of Foggia, 71122 Foggia, Italy
8 shared publications Domenico Ciavarella
Department of Clinical and Experimental Medicine, University of Foggia, Via Luigi Rovelli 48, 71122 Foggia, Italy
7 shared publications- Domenico Ciavarella
Department of Clinical and Experimental Medicine, University of Foggia, 71122 Foggia, Italy
5 shared publications - Giuseppe Troiano
Department of Clinical and Experimental Medicine University of Foggia Foggia Italy
5 shared publications
Latest Publications
- Open Access
- 24 May 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (11) , 5262
Treatment of Skeletal Mandibular Asymmetry with Functional Appliances—A Retrospective Case-Control Study
Objective: Skeletal mandibular asymmetry (MA) is a pathological condition characterised by asymmetric mandibular growth, resulting in chin deviation and, in some cases, non-coincident dental midlines. Because it is a skeletal condition, some clinicians choose to treat it with functional appliances. The present study therefore evaluated whether functional appliances with asymmetric activation can promote more symmetrical growth of the mandibular condyles and rami. Methods: Eighty-five patients with MA were retrospectively selected based on cervical skeletal maturation stage 2 or 3, the presence of skeletal and dental Class II malocclusion, and the availability of good-quality orthopantomograms taken before and after treatment. Among the enrolled patients, 40 were treated with functional appliances to protrude and re-centre the mandible (study group), while 45 were treated only with a rapid maxillary expander (positive and treated control group). This control group was chosen because it has no direct effects on the mandible and avoided the ethical concerns associated with postponing time-sensitive treatment to recruit a negative control group. Ramus and condyle asymmetry were evaluated pre- and post-treatment using Habets’ method. The Mann–Whitney U-test was used to compare pre- and post-treatment asymmetry indices between the two groups. Results: Although both groups showed a post-treatment symmetry improvement, no statistically significant between-group differences were observed (p = 0.712, effect size r = 0.14 for ramal symmetry; p = 0.663, effect size r = −0.01 for condylar symmetry). Conclusions: Within the limitations of this study, functional appliances did not demonstrate greater skeletal effects than the positive control treatment.
- 24 May 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (11) , 5262
Open AccessTreatment of Skeletal Mandibular Asymmetry with Functional Appliances—A Retrospective Case-Control Study
Objective: Skeletal mandibular asymmetry (MA) is a pathological condition characterised by asymmetric mandibular growth, resulting in chin deviation and, in some cases, non-coincident dental midlines. Because it is a skeletal condition, some clinicians choose to treat it with functional appliances. The present study therefore evaluated whether functional appliances with asymmetric activation can promote more symmetrical growth of the mandibular condyles and rami. Methods: Eighty-five patients with MA were retrospectively selected based on cervical skeletal maturation stage 2 or 3, the presence of skeletal and dental Class II malocclusion, and the availability of good-quality orthopantomograms taken before and after treatment. Among the enrolled patients, 40 were treated with functional appliances to protrude and re-centre the mandible (study group), while 45 were treated only with a rapid maxillary expander (positive and treated control group). This control group was chosen because it has no direct effects on the mandible and avoided the ethical concerns associated with postponing time-sensitive treatment to recruit a negative control group. Ramus and condyle asymmetry were evaluated pre- and post-treatment using Habets’ method. The Mann–Whitney U-test was used to compare pre- and post-treatment asymmetry indices between the two groups. Results: Although both groups showed a post-treatment symmetry improvement, no statistically significant between-group differences were observed (p = 0.712, effect size r = 0.14 for ramal symmetry; p = 0.663, effect size r = −0.01 for condylar symmetry). Conclusions: Within the limitations of this study, functional appliances did not demonstrate greater skeletal effects than the positive control treatment.
- Open Access
- 1 January 2026
- Published by XMLink in Journal of Periodontal & Implant Science
- Vol. 56
Influence of torque-curve dynamics on initial bone remodeling around dental implants: a multicenter prospective study
Stacchi C, et al. J Periodontal Implant Sci. 2026 ;56:e42. https://doi.org/10.5051/jpis.2601980099
- 1 January 2026
- Published by XMLink in Journal of Periodontal & Implant Science
- Vol. 56
Open AccessInfluence of torque-curve dynamics on initial bone remodeling around dental implants: a multicenter prospective study
Stacchi C, et al. J Periodontal Implant Sci. 2026 ;56:e42. https://doi.org/10.5051/jpis.2601980099
- Open Access
- 22 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (23) , 8309
Impact of Mandibular Advancement Therapy on Occlusal Plane Orientation and Incisor Inclination in Obstructive Sleep Apnea Patients: A Retrospective Observational Study
Objective: This observational study aimed to evaluate occlusal changes in patients with obstructive sleep apnea (OSA) treated with a mandibular advancement device after two years of therapy. Methods: Sixty adult patients with mild to moderate OSA (apnea–hypopnea index 15–30 events/h) were treated with the IMYS MAD for 24 months. Digital dental impressions were analyzed using Autodesk Meshmixer and Fusion 360 to measure sagittal, frontal, and occlusal angles, as well as upper incisor inclination at baseline (T0) and after treatment (T1). In addition, changes in the polysomnographic indices AHI and ODI were evaluated. Statistical analyses were performed using paired t-tests or Wilcoxon signed-rank tests depending on data normality (p < 0.05). Results: No significant differences were found between T0 and T1 in sagittal (IC 95% −2.053,1.433), occlusal (IC 95%, −1.202, 0.722) or frontal angles (IC 95% −1.487, 0.447), or in upper incisor inclination (IC 95%, 0.06,3.04). Polysomnographic parameters improved significantly, with mean AHI decreasing from 27.7 ± 12.3 (IC 95% 24.53–30.87) to 6.2 ± 4.0 events/h (IC 95% 5.17–7.27) and ODI from 19.7 ± 9.4 (IC 95% 17.27–22.13) to 4.7 ± 3.2 (IC 95% 3.82–5.48, p < 0.001). Conclusions: This study found that the IMYS MAD did not induce significant variations in occlusal plane orientation or upper incisors inclination after two years of treatment. These null findings suggest that the IMYS device may provide effective OSA management while minimizing the risk of occlusal or dental side effects. However, the retrospective design and the 24-month follow-up duration should be taken into consideration.
- 22 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (23) , 8309
Open AccessImpact of Mandibular Advancement Therapy on Occlusal Plane Orientation and Incisor Inclination in Obstructive Sleep Apnea Patients: A Retrospective Observational Study
Objective: This observational study aimed to evaluate occlusal changes in patients with obstructive sleep apnea (OSA) treated with a mandibular advancement device after two years of therapy. Methods: Sixty adult patients with mild to moderate OSA (apnea–hypopnea index 15–30 events/h) were treated with the IMYS MAD for 24 months. Digital dental impressions were analyzed using Autodesk Meshmixer and Fusion 360 to measure sagittal, frontal, and occlusal angles, as well as upper incisor inclination at baseline (T0) and after treatment (T1). In addition, changes in the polysomnographic indices AHI and ODI were evaluated. Statistical analyses were performed using paired t-tests or Wilcoxon signed-rank tests depending on data normality (p < 0.05). Results: No significant differences were found between T0 and T1 in sagittal (IC 95% −2.053,1.433), occlusal (IC 95%, −1.202, 0.722) or frontal angles (IC 95% −1.487, 0.447), or in upper incisor inclination (IC 95%, 0.06,3.04). Polysomnographic parameters improved significantly, with mean AHI decreasing from 27.7 ± 12.3 (IC 95% 24.53–30.87) to 6.2 ± 4.0 events/h (IC 95% 5.17–7.27) and ODI from 19.7 ± 9.4 (IC 95% 17.27–22.13) to 4.7 ± 3.2 (IC 95% 3.82–5.48, p < 0.001). Conclusions: This study found that the IMYS MAD did not induce significant variations in occlusal plane orientation or upper incisors inclination after two years of treatment. These null findings suggest that the IMYS device may provide effective OSA management while minimizing the risk of occlusal or dental side effects. However, the retrospective design and the 24-month follow-up duration should be taken into consideration.
- Open Access
- 6 August 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (16) , 6856
Effects of Nail Biting (Onychophagy) on Upper Central Incisors in Children and Young Adolescents
Nail biting (NB) is a repetitive and uncontrolled parafunctional activity that can affect oral health by altering tooth shape and intraoral position. Nowadays, there is not enough scientific evidence about the impact of NB on teeth; therefore, this study aimed to evaluate the effects of NB on the length, width and inclination of upper central incisors. This retrospective study involved 76 patients, 40 males and 36 females, with a mean age of 10.6 ± 0.3 years. Digital scans of the maxillary arch of each patient were recorded. Next, the length, width and inclination of upper central incisors used and not used for NB were measured. Finally, data were analysed with a paired t-test. Statistical analysis showed statistically significant differences in the length and inclination of upper central incisors used for NB compared with those of upper central incisors not used for NB, while the width did not show a significant difference. There were relevant changes in upper central incisors subjected to NB, demonstrating that NB impairs the shape, morphology and inclination of teeth. Therefore, because of the potentially negative consequences of NB, it is recommended that NB not be underestimated.
- 6 August 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (16) , 6856
Open AccessEffects of Nail Biting (Onychophagy) on Upper Central Incisors in Children and Young Adolescents
Nail biting (NB) is a repetitive and uncontrolled parafunctional activity that can affect oral health by altering tooth shape and intraoral position. Nowadays, there is not enough scientific evidence about the impact of NB on teeth; therefore, this study aimed to evaluate the effects of NB on the length, width and inclination of upper central incisors. This retrospective study involved 76 patients, 40 males and 36 females, with a mean age of 10.6 ± 0.3 years. Digital scans of the maxillary arch of each patient were recorded. Next, the length, width and inclination of upper central incisors used and not used for NB were measured. Finally, data were analysed with a paired t-test. Statistical analysis showed statistically significant differences in the length and inclination of upper central incisors used for NB compared with those of upper central incisors not used for NB, while the width did not show a significant difference. There were relevant changes in upper central incisors subjected to NB, demonstrating that NB impairs the shape, morphology and inclination of teeth. Therefore, because of the potentially negative consequences of NB, it is recommended that NB not be underestimated.
- Open Access
- 3 October 2022
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 25 (1) , 133-140
Changes in implant stability using different site preparation techniques: Osseodensification drills versus piezoelectric surgery. A multi‐center prospective randomized controlled clinical trial
Introduction: Implant stability is influenced by bone density, implant design, and site preparation characteristics. Piezoelectric implant site preparation (PISP) has been demonstrated to improve secondary stability compared with conventional drilling techniques. Osseodensification drills (OD) have been recently introduced to enhance both bone density and implant secondary stability. The objective of the present multi‐center prospective randomized controlled trial was to monitor implant stability changes over the first 90 days of healing after implant bed preparation with OD or PISP.Methods: Each patient received two identical, adjacent or contralateral implants in the posterior maxilla. Following randomization, test sites were prepared with OD and control sites with PISP. Resonance frequency analysis was performed immediately after implant placement and after 7, 14, 21, 28, 60, and 90 days. Implants were then restored with single screw‐retained metal‐ceramic crowns and followed for 12 months after loading.Results: Twenty‐seven patients (15 males and 12 females; mean age 63.0 ± 11.8 years) were included in final analysis. Each patient received two identical implants in the posterior maxilla (total = 54 implants). After 1 year of loading, 53 implants were satisfactorily in function (one failure in test group 28 days after placement). Mean peak insertion torque (40.7 ± 12.3 Ncm and 39.5 ± 10.2 Ncm in test and control group, respectively) and mean implant stability quotient (ISQ) value at baseline (71.3 ± 6.9 and 69.3 ± 7.6 in test and control group, respectively) showed no significant differences between the two groups. After an initial slight stability decrease, a shift to increasing ISQ values occurred after 14 days in control group and after 21 days in test group, but with no significant differences in ISQ values between the two groups during the first 90 days of healing.Conclusion: No significant differences in either primary or secondary stability or implant survival rate after 1 year of loading were demonstrated between implants inserted into sites prepared with OD and PISP.
- 3 October 2022
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 25 (1) , 133-140
Open AccessChanges in implant stability using different site preparation techniques: Osseodensification drills versus piezoelectric surgery. A multi‐center prospective randomized controlled clinical trial
Introduction: Implant stability is influenced by bone density, implant design, and site preparation characteristics. Piezoelectric implant site preparation (PISP) has been demonstrated to improve secondary stability compared with conventional drilling techniques. Osseodensification drills (OD) have been recently introduced to enhance both bone density and implant secondary stability. The objective of the present multi‐center prospective randomized controlled trial was to monitor implant stability changes over the first 90 days of healing after implant bed preparation with OD or PISP.Methods: Each patient received two identical, adjacent or contralateral implants in the posterior maxilla. Following randomization, test sites were prepared with OD and control sites with PISP. Resonance frequency analysis was performed immediately after implant placement and after 7, 14, 21, 28, 60, and 90 days. Implants were then restored with single screw‐retained metal‐ceramic crowns and followed for 12 months after loading.Results: Twenty‐seven patients (15 males and 12 females; mean age 63.0 ± 11.8 years) were included in final analysis. Each patient received two identical implants in the posterior maxilla (total = 54 implants). After 1 year of loading, 53 implants were satisfactorily in function (one failure in test group 28 days after placement). Mean peak insertion torque (40.7 ± 12.3 Ncm and 39.5 ± 10.2 Ncm in test and control group, respectively) and mean implant stability quotient (ISQ) value at baseline (71.3 ± 6.9 and 69.3 ± 7.6 in test and control group, respectively) showed no significant differences between the two groups. After an initial slight stability decrease, a shift to increasing ISQ values occurred after 14 days in control group and after 21 days in test group, but with no significant differences in ISQ values between the two groups during the first 90 days of healing.Conclusion: No significant differences in either primary or secondary stability or implant survival rate after 1 year of loading were demonstrated between implants inserted into sites prepared with OD and PISP.
- Open Access
- 12 January 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (1) , 31
Maxillary Transverse Deficit: A Retrospective Study of Two Biologically Oriented Devices through a Digital Workflow
The aim of this retrospective study was to compare the efficiency of two biologically oriented devices in achieving maxillary expansion: Rapid Palatal Expander (RPE) and Nitanium Palatal Expander-2 (NPE-2). Thirty-six subjects, divided in two equal groups, were included in this study. Maxillary dental arches were scanned using Trios 3 shape®, in order to perform a digital analysis of 3D models. The models were analyzed using Autodesk Fusion 360® and Meshmixer®. All data obtained from analysis of pre-treatment and post-treatment models were processed using Prism® software. The anterior arch width, the posterior arch width, the palate height, and palatal surface were measured to evaluate differences between the devices. A D’Agostino–Pearson normality test was done to check the data. A non-parametric t-test was used to compare the anterior and posterior arch width between the two groups, while a parametric t-test was used to compare the palatal height measurements between the two groups. The p-value was calculated. The limit value fixed was 0.05. Palatal width and surface showed a significant increase in both groups, but no significant changes in palatal height were found. The data processed showed that there were no significant differences between the devices (ΔREP−ΔNPE) in variation of anterior arch width, there were no significant differences in variation of posterior arch width and there were no significant differences in variation of palatal height. The comparison between the two groups showed that both methods were equally effective in correcting transverse defect.
- 12 January 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (1) , 31
Open AccessMaxillary Transverse Deficit: A Retrospective Study of Two Biologically Oriented Devices through a Digital Workflow
The aim of this retrospective study was to compare the efficiency of two biologically oriented devices in achieving maxillary expansion: Rapid Palatal Expander (RPE) and Nitanium Palatal Expander-2 (NPE-2). Thirty-six subjects, divided in two equal groups, were included in this study. Maxillary dental arches were scanned using Trios 3 shape®, in order to perform a digital analysis of 3D models. The models were analyzed using Autodesk Fusion 360® and Meshmixer®. All data obtained from analysis of pre-treatment and post-treatment models were processed using Prism® software. The anterior arch width, the posterior arch width, the palate height, and palatal surface were measured to evaluate differences between the devices. A D’Agostino–Pearson normality test was done to check the data. A non-parametric t-test was used to compare the anterior and posterior arch width between the two groups, while a parametric t-test was used to compare the palatal height measurements between the two groups. The p-value was calculated. The limit value fixed was 0.05. Palatal width and surface showed a significant increase in both groups, but no significant changes in palatal height were found. The data processed showed that there were no significant differences between the devices (ΔREP−ΔNPE) in variation of anterior arch width, there were no significant differences in variation of posterior arch width and there were no significant differences in variation of palatal height. The comparison between the two groups showed that both methods were equally effective in correcting transverse defect.
- 1 November 2021
- Published by Edra SpA in Dental Cadmos
- Vol. 89 (9) , 688-696
Platform switching vs platform matching: a radiographic analysis of marginal bone loss
OBJECTIVES A considerable literature claimed that the use of platform switching protocol reduces the exposure of bone crest to the effects of inflammation at implant-abutment junction. The aim of this study was to evaluate differences in marginal bone loss (MBL) between sites treated with platform switching (PS) protocol and sites treated with platform matching (PM) protocol, evaluating the existence of an advantage that PS can bring in the process of bone remodeling. MATERIALS AND METHODS A retrospective study based on the analysis of a series of data on patients undergoing implant-prosthetic treatment was carried out. 24 patients was included in the cohort, of these: 12 patients were treated with a PS approach and formed the test group, while 12 patients were treated with a PM protocol forming the control group. A total of 36 external connection implants were evaluated: out of 15 implants the PS protocol was applied and on 21 the PM protocol. For each patient, periapical radiographs were made using the long-cone technique at the end of the surgical phase (T0) and at the end of the prosthetic phase. A time range of 4-6 months was considered, between the surgical phase and the delivery of the definitive prosthesis. All the implants underwent a non-submerged healing process. After collecting all the oral radiographs in T0 and T1 for each implant of each patient from both study groups, the bone height around the implant with the Auto-CAD (R) program was assessed on each oral radiograph. Measurements have been made on both mesial and distal bone height of the fixture. In this way it was possible to evaluate both the initial marginal bone level at T0 (I-MBL) and the final marginal bone level at T1 (F-MBL) around to the implants treated with the PS or PM protocol. Subsequently, the Marginal Bone Loss (Delta-MBL) was calculated as a difference between I-MBL and F-MBL at both mesial and distal side of the implant, in addition the average Delta-MBL between mesial and distal aspect was also calculated. RESULTS After elaborating the measurements taken at the mesial and distal levels for each implant at T0 and T1, and after calculating all the averages in both study groups, the total averages were calculated. The data were subjected to statistical analysis by means of the independent samples Mann-Whitney U Test, in order to compare the MBL results obtained at implant level. Results of this study revealed a significant lower distal Delta-MBL in the PS group than in the PM group. Indeed, both mesial Delta-MBL and average Delta-MBL showed no statistically significant differences between the two groups. CONCLUSIONS At mesial MBL and the average of the two MBL there were no statistically significant results that allow to prefer one protocol instead to the other. Radiographic evaluation of Delta-MBLs between implants treated with PS and PM protocols showed small differences in favor of the PS protocol at mesial side, while no differences were detected at distal side and as average between the two sites. The results obtained can be integrated by a medium-long term radiographic follow-up, thus analyzing the changes of mesial and distal MBL over time. CLINICAL SIGNIFICANCE Within the limits of this study, it is considered advisable to apply the surgical/prosthetic platform switching protocol in order to obtain a homogeneous and predictable response of hard tissues, reducing the rate of peri-implant bone resorption.
- 1 November 2021
- Published by Edra SpA in Dental Cadmos
- Vol. 89 (9) , 688-696
Platform switching vs platform matching: a radiographic analysis of marginal bone loss
OBJECTIVES A considerable literature claimed that the use of platform switching protocol reduces the exposure of bone crest to the effects of inflammation at implant-abutment junction. The aim of this study was to evaluate differences in marginal bone loss (MBL) between sites treated with platform switching (PS) protocol and sites treated with platform matching (PM) protocol, evaluating the existence of an advantage that PS can bring in the process of bone remodeling. MATERIALS AND METHODS A retrospective study based on the analysis of a series of data on patients undergoing implant-prosthetic treatment was carried out. 24 patients was included in the cohort, of these: 12 patients were treated with a PS approach and formed the test group, while 12 patients were treated with a PM protocol forming the control group. A total of 36 external connection implants were evaluated: out of 15 implants the PS protocol was applied and on 21 the PM protocol. For each patient, periapical radiographs were made using the long-cone technique at the end of the surgical phase (T0) and at the end of the prosthetic phase. A time range of 4-6 months was considered, between the surgical phase and the delivery of the definitive prosthesis. All the implants underwent a non-submerged healing process. After collecting all the oral radiographs in T0 and T1 for each implant of each patient from both study groups, the bone height around the implant with the Auto-CAD (R) program was assessed on each oral radiograph. Measurements have been made on both mesial and distal bone height of the fixture. In this way it was possible to evaluate both the initial marginal bone level at T0 (I-MBL) and the final marginal bone level at T1 (F-MBL) around to the implants treated with the PS or PM protocol. Subsequently, the Marginal Bone Loss (Delta-MBL) was calculated as a difference between I-MBL and F-MBL at both mesial and distal side of the implant, in addition the average Delta-MBL between mesial and distal aspect was also calculated. RESULTS After elaborating the measurements taken at the mesial and distal levels for each implant at T0 and T1, and after calculating all the averages in both study groups, the total averages were calculated. The data were subjected to statistical analysis by means of the independent samples Mann-Whitney U Test, in order to compare the MBL results obtained at implant level. Results of this study revealed a significant lower distal Delta-MBL in the PS group than in the PM group. Indeed, both mesial Delta-MBL and average Delta-MBL showed no statistically significant differences between the two groups. CONCLUSIONS At mesial MBL and the average of the two MBL there were no statistically significant results that allow to prefer one protocol instead to the other. Radiographic evaluation of Delta-MBLs between implants treated with PS and PM protocols showed small differences in favor of the PS protocol at mesial side, while no differences were detected at distal side and as average between the two sites. The results obtained can be integrated by a medium-long term radiographic follow-up, thus analyzing the changes of mesial and distal MBL over time. CLINICAL SIGNIFICANCE Within the limits of this study, it is considered advisable to apply the surgical/prosthetic platform switching protocol in order to obtain a homogeneous and predictable response of hard tissues, reducing the rate of peri-implant bone resorption.
- Open Access
- 1 January 2021
- Published by Medicina Oral, S.L. in Journal of Clinical and Experimental Dentistry
- Vol. 13 (6) , e594-e600
Long-term effect on adenoid dimensions and craniocervical angulation after maxillary expansion with fixed or functional appliances
Maxillary expansion is a common orthodontic procedure that could have a positive effect also on airway patency. The aim of the present study was to evaluate the long-term effects of rapid maxillary expansion (RME) on nasopharyngeal area and cranio-cervical angulation in growing patients, compared to controls treated with a function-generating bite appliance (FGB). Sixty patients aged 6-14 consecutively treated with RME or FGB were selected retrospectively and divided into two groups. Lateral cephalograms taken before and after treatment were retrieved, and the nasopharyngeal area, delimited superiorly by a sella-posterior nasal spine (PNS) line and inferiorly by a basion-PNS line, and the cranio-cervical angulation were measured. The mean observation time was 17.6 ± 8 months. No differences were present between the two groups regarding age and gender. The nasopharyngeal area increased significantly in both groups after treatment, but with no statistically significant difference between them. The cranio-cervical angulation showed no differences within or between groups. Maxillary deficiency treatment with either RME or FGB was followed by a comparable increase in nasopharyngeal area. Key words:Rapid maxillary expansion, Airway, Nasopharyngeal area, Adenoid.
- 1 January 2021
- Published by Medicina Oral, S.L. in Journal of Clinical and Experimental Dentistry
- Vol. 13 (6) , e594-e600
Open AccessLong-term effect on adenoid dimensions and craniocervical angulation after maxillary expansion with fixed or functional appliances
Maxillary expansion is a common orthodontic procedure that could have a positive effect also on airway patency. The aim of the present study was to evaluate the long-term effects of rapid maxillary expansion (RME) on nasopharyngeal area and cranio-cervical angulation in growing patients, compared to controls treated with a function-generating bite appliance (FGB). Sixty patients aged 6-14 consecutively treated with RME or FGB were selected retrospectively and divided into two groups. Lateral cephalograms taken before and after treatment were retrieved, and the nasopharyngeal area, delimited superiorly by a sella-posterior nasal spine (PNS) line and inferiorly by a basion-PNS line, and the cranio-cervical angulation were measured. The mean observation time was 17.6 ± 8 months. No differences were present between the two groups regarding age and gender. The nasopharyngeal area increased significantly in both groups after treatment, but with no statistically significant difference between them. The cranio-cervical angulation showed no differences within or between groups. Maxillary deficiency treatment with either RME or FGB was followed by a comparable increase in nasopharyngeal area. Key words:Rapid maxillary expansion, Airway, Nasopharyngeal area, Adenoid.
- 1 January 2020
- Published by VM Media Group sp. z o.o in Folia Morphologica
- Vol. 79 (1) , 51-57
Sella turcica and craniofacial morphology in patients with palatally displaced canines: a retrospective study
Background: The aim of the study was to evaluate the sella and craniofacial morphological features in growing patients with palatally displaced canines compared to controls. Materials and methods: Twenty-two subjects with palatally displaced canines were retrospectively selected and compared to 22 controls matched for age and gender. Lateral cephalograms were collected and sagittal and vertical cephalometric variables were measured, together with sella interclinoid distance, sella depth, and sella diameter. The independent samples T-test or Mann-Whitney U-test were used to compare all the variables between the two groups. A Pearson correlation was computed for the craniofacial and sella variables that differed significantly (p < 0.05) between the groups. Results: Patients with palatally displaced canines showed a smaller interclinoid distance and a greater SNA angle than control subjects. The interclinoid distance and the SNA angle were negatively correlated (-0.52, p = 0.017) in the experimental group. Conclusions: Growing patients with palatally displaced canines had smaller sella interclinoid distances and a greater SNA angle than control subjects.
- 1 January 2020
- Published by VM Media Group sp. z o.o in Folia Morphologica
- Vol. 79 (1) , 51-57
Sella turcica and craniofacial morphology in patients with palatally displaced canines: a retrospective study
Background: The aim of the study was to evaluate the sella and craniofacial morphological features in growing patients with palatally displaced canines compared to controls. Materials and methods: Twenty-two subjects with palatally displaced canines were retrospectively selected and compared to 22 controls matched for age and gender. Lateral cephalograms were collected and sagittal and vertical cephalometric variables were measured, together with sella interclinoid distance, sella depth, and sella diameter. The independent samples T-test or Mann-Whitney U-test were used to compare all the variables between the two groups. A Pearson correlation was computed for the craniofacial and sella variables that differed significantly (p < 0.05) between the groups. Results: Patients with palatally displaced canines showed a smaller interclinoid distance and a greater SNA angle than control subjects. The interclinoid distance and the SNA angle were negatively correlated (-0.52, p = 0.017) in the experimental group. Conclusions: Growing patients with palatally displaced canines had smaller sella interclinoid distances and a greater SNA angle than control subjects.
- Open Access
- 31 January 2019
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 13 (1) , 41-47
Comparison of the Stress Strain Capacity between Different Clear Aligners
Background: The rife use of aesthetic appliance in orthodontic treatment requires the study of the properties of the materials they are made of.Objective: The aim of the present study was to evaluate the dimensional stability of clear aligners made of three different materials after the application ofin-vivodynamic stress andin-vitrostatic stress.Methods: Three different aligners made of different materials (PET-G; PET; SmartTrack®), prepared on the dental arch of the same patient, were tested. For each material, three aligner samples were manufactured: one to be usedin-vivo, one to be testedin-vitro, and one to be used as a control.To evaluate the effects of the dynamic stress producedin-vivo, each aligner was worn by a single patient 22 hours per day, followed by a wash-out period of two weeks. To evaluate the effects of static stress, each aligner was exposed to thein-vitrocontinuous force of 50N. The tested and control aligners were scanned, then linear measurements were taken to evaluate their dimensional stability after different types of stresses.Results: PET seems to have the lowest percentage of deformation; PET-G and SmartTrack®showed a reduced deformation going from the posterior to the anterior area. The contact with human saliva induces a greater deformation.Conclusion: Different materials show different behavior following application of static stresses and dynamic stresses in the oral cavity. PET showed the highest dimensional stability.
- 31 January 2019
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 13 (1) , 41-47
Open AccessComparison of the Stress Strain Capacity between Different Clear Aligners
Background: The rife use of aesthetic appliance in orthodontic treatment requires the study of the properties of the materials they are made of.Objective: The aim of the present study was to evaluate the dimensional stability of clear aligners made of three different materials after the application ofin-vivodynamic stress andin-vitrostatic stress.Methods: Three different aligners made of different materials (PET-G; PET; SmartTrack®), prepared on the dental arch of the same patient, were tested. For each material, three aligner samples were manufactured: one to be usedin-vivo, one to be testedin-vitro, and one to be used as a control.To evaluate the effects of the dynamic stress producedin-vivo, each aligner was worn by a single patient 22 hours per day, followed by a wash-out period of two weeks. To evaluate the effects of static stress, each aligner was exposed to thein-vitrocontinuous force of 50N. The tested and control aligners were scanned, then linear measurements were taken to evaluate their dimensional stability after different types of stresses.Results: PET seems to have the lowest percentage of deformation; PET-G and SmartTrack®showed a reduced deformation going from the posterior to the anterior area. The contact with human saliva induces a greater deformation.Conclusion: Different materials show different behavior following application of static stresses and dynamic stresses in the oral cavity. PET showed the highest dimensional stability.