Christopher Nemeth
Research Subjects
Christopher Nemeth has a total of 171 co-authors. Here are the top co-authors by number of shared publications:
Richard Cook
9 shared publicationsRichard I. Cook
9 shared publicationsBeth Crandall
Cognitive Solutions Division, Applied Research Associates, Inc., 1750 Commerce Center Boulevard Drive North, Fairborn, OH 23542
6 shared publicationsAnna Grome
Cognitive Solutions Division, Applied Research Associates, Inc., 1750 Commerce Center Boulevard Drive North, Fairborn, OH 23542
4 shared publicationsDawn Laufersweiler
Applied Research Associates (United States)
4 shared publicationsElizabeth Mann-Salinas
4 shared publications
Latest Publications
- 23 October 2025
- Published by Massachusetts Medical Society in NEJM AI
- Vol. 2 (11)
A Case Study of AI-Enabled Software as a Medical Device Cleared by the FDA for Assessing Hemorrhage Risk Index (APPRAISE-HRI) after Trauma
Hemorrhage is the leading cause of preventable death on the battlefield, yet combat medics lack clinical decision support systems to help stratify hemorrhage risk in trauma casualties. We previously trained the Automated Processing of the Physiological Registry for Assessment of Injury Severity — Hemorrhage Risk Index (APPRAISE-HRI) software to associate patterns in vital signs (heart rate and blood pressure) collected from trauma patients with three HRI levels: I (low), II (average), or III (high). To independently validate APPRAISE-HRI and obtain U.S. Food and Drug Administration (FDA) clearance, we collected trauma registry and continuous vital sign data from 5895 trauma patients (543 with hemorrhagic injuries and 5352 controls) in an emergency department or during prehospital transport to one of eight medical centers. The study outcome was hemorrhagic injury, defined by documented injuries and blood transfusion. Using the likelihood ratio to assess the ability of APPRAISE-HRI to stratify hemorrhage risk, we found that hemorrhagic patients were 6.88 times as likely as controls to be at level III, strongly suggesting the presence of hemorrhage at this level. Similarly, hemorrhagic patients were 0.18 times as likely as controls to be at level I, suggesting the absence of hemorrhage at this level. Hemorrhagic patients were almost as likely as controls to be at level II (0.70 times as likely). Subsequently, the U.S. Department of Defense obtained FDA 510(k) clearance for the artificial intelligence–enabled APPRAISE-HRI Class II device (K233249), the first software as a medical device approved for assessing hemorrhage risk in trauma patients, allowing for triage and identification of casualties who need immediate attention and evacuation. (Funded by the U.S. Army Medical Materiel Development Activity and the Combat Casualty Care Program Area Directorate (CCCPAD) of the U.S. Army Medical Research and Development Command (USAMRDC), Fort Detrick, MD and others.)
- 23 October 2025
- Published by Massachusetts Medical Society in NEJM AI
- Vol. 2 (11)
A Case Study of AI-Enabled Software as a Medical Device Cleared by the FDA for Assessing Hemorrhage Risk Index (APPRAISE-HRI) after Trauma
Hemorrhage is the leading cause of preventable death on the battlefield, yet combat medics lack clinical decision support systems to help stratify hemorrhage risk in trauma casualties. We previously trained the Automated Processing of the Physiological Registry for Assessment of Injury Severity — Hemorrhage Risk Index (APPRAISE-HRI) software to associate patterns in vital signs (heart rate and blood pressure) collected from trauma patients with three HRI levels: I (low), II (average), or III (high). To independently validate APPRAISE-HRI and obtain U.S. Food and Drug Administration (FDA) clearance, we collected trauma registry and continuous vital sign data from 5895 trauma patients (543 with hemorrhagic injuries and 5352 controls) in an emergency department or during prehospital transport to one of eight medical centers. The study outcome was hemorrhagic injury, defined by documented injuries and blood transfusion. Using the likelihood ratio to assess the ability of APPRAISE-HRI to stratify hemorrhage risk, we found that hemorrhagic patients were 6.88 times as likely as controls to be at level III, strongly suggesting the presence of hemorrhage at this level. Similarly, hemorrhagic patients were 0.18 times as likely as controls to be at level I, suggesting the absence of hemorrhage at this level. Hemorrhagic patients were almost as likely as controls to be at level II (0.70 times as likely). Subsequently, the U.S. Department of Defense obtained FDA 510(k) clearance for the artificial intelligence–enabled APPRAISE-HRI Class II device (K233249), the first software as a medical device approved for assessing hemorrhage risk in trauma patients, allowing for triage and identification of casualties who need immediate attention and evacuation. (Funded by the U.S. Army Medical Materiel Development Activity and the Combat Casualty Care Program Area Directorate (CCCPAD) of the U.S. Army Medical Research and Development Command (USAMRDC), Fort Detrick, MD and others.)
- 24 October 2024
- Published by Elsevier in Applied Ergonomics
- Vol. 122, 104375
Quantitative analysis of facial shape in children to support respirator design
- 24 October 2024
- Published by Elsevier in Applied Ergonomics
- Vol. 122, 104375
Quantitative analysis of facial shape in children to support respirator design
- 21 May 2024
- Published by Springer Nature in Cognition, Technology & Work
- Vol. 26 (3) , 375-384
Decision support for CBRN avoid and protect missions
- 21 May 2024
- Published by Springer Nature in Cognition, Technology & Work
- Vol. 26 (3) , 375-384
Decision support for CBRN avoid and protect missions
- Open Access
- 31 January 2024
- Published by Springer Nature in Research Square
Decision Support for CBRN Avoid and Protect Missions
Modern Chemical Biological Radiological Nuclear (CBRN) operations require a significant reduction in the time between decision making and decision execution. This calls for effective decision support to improve situational awareness (SA) at the lowest practical echelon. Applied Research Associates, Inc. conducted a 22-month project to research Avoidance and Protection, the CBRN phase with greatest uncertainty and cognitive work demands, to determine how the Android Tactical Assault Kit (ATAK) could best support operator procedures and decision making. We confirmed U.S. Department of Defense (DoD) CBRN doctrine, created battalion commander, medical officer, CBRN specialist, and Soldier or Marine use cases, developed a concept video around existing CBRN passive defense workflows and tasking, then reviewed the concept with CBRN specialists returning from deployment as well as Integrated Early Warning and CBRN Support to Command-and-Control developers. Resulting improvement to decision support can more effectively sustain the operator’s observe, orient, decide, and act (OODA) loop while minimizing cognitive load.
- 31 January 2024
- Published by Springer Nature in Research Square
Open AccessDecision Support for CBRN Avoid and Protect Missions
Modern Chemical Biological Radiological Nuclear (CBRN) operations require a significant reduction in the time between decision making and decision execution. This calls for effective decision support to improve situational awareness (SA) at the lowest practical echelon. Applied Research Associates, Inc. conducted a 22-month project to research Avoidance and Protection, the CBRN phase with greatest uncertainty and cognitive work demands, to determine how the Android Tactical Assault Kit (ATAK) could best support operator procedures and decision making. We confirmed U.S. Department of Defense (DoD) CBRN doctrine, created battalion commander, medical officer, CBRN specialist, and Soldier or Marine use cases, developed a concept video around existing CBRN passive defense workflows and tasking, then reviewed the concept with CBRN specialists returning from deployment as well as Integrated Early Warning and CBRN Support to Command-and-Control developers. Resulting improvement to decision support can more effectively sustain the operator’s observe, orient, decide, and act (OODA) loop while minimizing cognitive load.
- Open Access
- 1 November 2023
- Published by Oxford University Press (OUP) in Military Medicine
- Vol. 188 (Supplement) , 659-665
TCCC Decision Support With Machine Learning Prediction of Hemorrhage Risk, Shock Probability
Introduction: Expected future delays in evacuation during near-peer conflicts in remote locales are expected to require extended care including prolonged field care over hours to days. Such delays can increase potential complications, such as insufficient blood flow (shock), bloodstream infection (sepsis), internal bleeding (hemorrhage), and require more complex treatment beyond stabilization. The Trauma Triage Treatment and Training Decision Support (4TDS) system is a real-time decision support system to monitor casualty health and identify such complications. The 4TDS software prototype operates on an Android smart phone or tablet configured for use in the DoD Nett Warrior program. It includes machine learning models to evaluate trends in six vital signs streamed from a sensor placed on a casualty to identify shock probability, internal hemorrhage risk, and need for a massive transfusion. Materials and Methods: The project team used a mixed methods approach to create and evaluate the system including literature review, rapid prototyping, design requirements review, agile development, an algorithm “silent test,” and usability assessments with novice to expert medics from all three services. Results: Both models, shock (showing an accuracy of 0.83) and hemorrhage/massive transfusion protocol, were successfully validated using externally collected data. All usability assessment participants completed refresher training scenarios and were able to accurately assess a simulated casualty’s condition using the phone prototype. Mean responses to statements on evaluation criteria [e.g., fit with Tactical Combat Casualty Care (TCCC), ease of use, and decision confidence] fell at five or above on a 7-point scale, indicating strong support. Conclusions: Participatory design ensured 4TDS and machine learning models reflect medic and clinician mental models and work processes and built support among potential users should the system transition to operational use. Validation results can support 4TDS readiness for FDA 510k clearance as a Class II medical device.
- 1 November 2023
- Published by Oxford University Press (OUP) in Military Medicine
- Vol. 188 (Supplement) , 659-665
Open AccessTCCC Decision Support With Machine Learning Prediction of Hemorrhage Risk, Shock Probability
Introduction: Expected future delays in evacuation during near-peer conflicts in remote locales are expected to require extended care including prolonged field care over hours to days. Such delays can increase potential complications, such as insufficient blood flow (shock), bloodstream infection (sepsis), internal bleeding (hemorrhage), and require more complex treatment beyond stabilization. The Trauma Triage Treatment and Training Decision Support (4TDS) system is a real-time decision support system to monitor casualty health and identify such complications. The 4TDS software prototype operates on an Android smart phone or tablet configured for use in the DoD Nett Warrior program. It includes machine learning models to evaluate trends in six vital signs streamed from a sensor placed on a casualty to identify shock probability, internal hemorrhage risk, and need for a massive transfusion. Materials and Methods: The project team used a mixed methods approach to create and evaluate the system including literature review, rapid prototyping, design requirements review, agile development, an algorithm “silent test,” and usability assessments with novice to expert medics from all three services. Results: Both models, shock (showing an accuracy of 0.83) and hemorrhage/massive transfusion protocol, were successfully validated using externally collected data. All usability assessment participants completed refresher training scenarios and were able to accurately assess a simulated casualty’s condition using the phone prototype. Mean responses to statements on evaluation criteria [e.g., fit with Tactical Combat Casualty Care (TCCC), ease of use, and decision confidence] fell at five or above on a 7-point scale, indicating strong support. Conclusions: Participatory design ensured 4TDS and machine learning models reflect medic and clinician mental models and work processes and built support among potential users should the system transition to operational use. Validation results can support 4TDS readiness for FDA 510k clearance as a Class II medical device.
- 12 October 2021
- Published by Springer Nature
- p. 157-158
Quo Vadis?
- 12 October 2021
- Published by Springer Nature
- p. 1-9
From Resilience Engineering to Resilient Performance
- 12 October 2021
- Published by Springer Nature
- p. 1-9
From Resilience Engineering to Resilient Performance
- 23 July 2021
- Published by Springer Nature
- p. 37-42
Foresight: How Simulation Can Promote Resilient Performance
- 23 July 2021
- Published by Springer Nature
- p. 37-42
Foresight: How Simulation Can Promote Resilient Performance
- 3 July 2021
- Published by Springer Nature
- p. 218-226
Decision Support for Prolonged, and Tactical Combat Casualty Care
- 3 July 2021
- Published by Springer Nature
- p. 218-226
Decision Support for Prolonged, and Tactical Combat Casualty Care
- 12 March 2020
- Published by Wolters Kluwer Health in Journal of Patient Safety
- Vol. 16 (2) , 117-122
Preparing for an Influenza Pandemic: Hospital Acceptance Study of Filtering Facepiece Respirator Decontamination Using Ultraviolet Germicidal Irradiation
Objectives: Predictions estimate supplies of filtering facepiece respirators (FFRs) would be limited in the event of a severe influenza pandemic. Ultraviolet decontamination and reuse (UVDR) is a potential approach to mitigate an FFR shortage. A field study sought to understand healthcare workers’ perspectives and potential logistics issues related to implementation of UVDR methods for FFRs in hospitals. Methods: Data were collected at three hospitals using a structured guide to conduct 19 individual interviews, 103 focus group interviews, and 285 individual surveys. Data were then evaluated using thematic analysis to reveal key themes. Results: Data revealed noteworthy variation in FFR use across the sample, along with preferences and requirements for the use of UVDR, unit design, and FFR reuse. Based on a scale of 1 (low) to 10 (high), the mean perception of safety in a high mortality pandemic wearing no FFR was 1.25 of 10, wearing an FFR for an extended period without decontamination was 4.20 of 10, and using UVDR was 7.72 of 10. Conclusions: In addition to technical design and development, preparation and training will be essential to successful implementation of a UVDR program. Ultraviolet decontamination and reuse program design and implementation must account for actual clinical practice, compliance with regulations, and practical financial considerations to be successfully adopted so that it can mitigate potential FFR shortages in a pandemic.
- 12 March 2020
- Published by Wolters Kluwer Health in Journal of Patient Safety
- Vol. 16 (2) , 117-122
Preparing for an Influenza Pandemic: Hospital Acceptance Study of Filtering Facepiece Respirator Decontamination Using Ultraviolet Germicidal Irradiation
Objectives: Predictions estimate supplies of filtering facepiece respirators (FFRs) would be limited in the event of a severe influenza pandemic. Ultraviolet decontamination and reuse (UVDR) is a potential approach to mitigate an FFR shortage. A field study sought to understand healthcare workers’ perspectives and potential logistics issues related to implementation of UVDR methods for FFRs in hospitals. Methods: Data were collected at three hospitals using a structured guide to conduct 19 individual interviews, 103 focus group interviews, and 285 individual surveys. Data were then evaluated using thematic analysis to reveal key themes. Results: Data revealed noteworthy variation in FFR use across the sample, along with preferences and requirements for the use of UVDR, unit design, and FFR reuse. Based on a scale of 1 (low) to 10 (high), the mean perception of safety in a high mortality pandemic wearing no FFR was 1.25 of 10, wearing an FFR for an extended period without decontamination was 4.20 of 10, and using UVDR was 7.72 of 10. Conclusions: In addition to technical design and development, preparation and training will be essential to successful implementation of a UVDR program. Ultraviolet decontamination and reuse program design and implementation must account for actual clinical practice, compliance with regulations, and practical financial considerations to be successfully adopted so that it can mitigate potential FFR shortages in a pandemic.