Farzad Sadjadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Farzad Sadjadi has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Firooz A. Sadjadi
Lockheed Martin Corporation, Saint Anthony, Minnesota 55418, USA
1 shared publication Firooz Sadjadi
Lockheed Martin Corporation
1 shared publicationFirooz Sadjadiz
Lockheed Martin Corporation, Saint Paul, Minnesota
1 shared publication
Latest Publications
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Joint estimation of objects geometry and material labels from single view polarized hyperspectral imagery
This paper presents a novel method for extracting 3D information and material labels from a scene by means of a hyperspectral polarimetric passive imaging sensor. This sensor provides full Stokes vector at each sensor pixel location, from which, degree, angle of linear polarization and indices of refraction are computed. Angle of linear polarization provides the azimuth angle of the surface normal vector. The depression angle of this surface normal vector is obtained in terms of the emitting object's spectral index of refraction, from the solution of a set of equations derived from Fresnel equations, snell's law, and Sellmeier dispersion formula. Results of the application of this approach on simulated spectral infrared polarimetric data are provided.
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Joint estimation of objects geometry and material labels from single view polarized hyperspectral imagery
This paper presents a novel method for extracting 3D information and material labels from a scene by means of a hyperspectral polarimetric passive imaging sensor. This sensor provides full Stokes vector at each sensor pixel location, from which, degree, angle of linear polarization and indices of refraction are computed. Angle of linear polarization provides the azimuth angle of the surface normal vector. The depression angle of this surface normal vector is obtained in terms of the emitting object's spectral index of refraction, from the solution of a set of equations derived from Fresnel equations, snell's law, and Sellmeier dispersion formula. Results of the application of this approach on simulated spectral infrared polarimetric data are provided.
- 5 January 2009
- Published by Springer Nature
- p. 37-61
Passive Polarimetric Information Processing for Target Classification
- 5 January 2009
- Published by Springer Nature
- p. 37-61
Passive Polarimetric Information Processing for Target Classification
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10636919,p. 1-5
Extraction of surface normal and index of refraction using a pair of passive infrared polarimetric sensors
This paper summarizes a method for extracting 3D information and indices of refraction from a scene by means of a pair of polarimetric passive imaging sensors. Each sensor provides the Stokes vector at each sensor pixel location, from which, degree and angle of linear polarization are computed. Angle of linear polarization provides the azimuth angle of the surface normal vector. Two cases are considered. For the special case when the two sensors have a common azimuth plane the index of refraction can be find analytically in terms of the degrees of polarization and the angle between the lines of sight from the two sensors, from which the depression angle of the surface normal can be computed. For the second and more general case the surface normal is estimated from the cross-product of the azimuth vectors from the two sensors and the inner product of the line of sight vectors and surface normal. Once the de-presion angles are estimated the index of refraction can be computed.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10636919,p. 1-5
Extraction of surface normal and index of refraction using a pair of passive infrared polarimetric sensors
This paper summarizes a method for extracting 3D information and indices of refraction from a scene by means of a pair of polarimetric passive imaging sensors. Each sensor provides the Stokes vector at each sensor pixel location, from which, degree and angle of linear polarization are computed. Angle of linear polarization provides the azimuth angle of the surface normal vector. Two cases are considered. For the special case when the two sensors have a common azimuth plane the index of refraction can be find analytically in terms of the degrees of polarization and the angle between the lines of sight from the two sensors, from which the depression angle of the surface normal can be computed. For the second and more general case the surface normal is estimated from the cross-product of the azimuth vectors from the two sensors and the inner product of the line of sight vectors and surface normal. Once the de-presion angles are estimated the index of refraction can be computed.
- 22 October 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5557, 356-364
Comparison of fitness scaling functions in genetic algorithms with applications to optical processing
Many optical or image processing tasks reduce to the optimization of some set of parameters. Genetic algorithms can optimize these parameters even when the functions they map are fairly complicated, but they can only do so the point where the fitness functions they are given can differentiate between good results and the best result. This can occur when the optimal point is in a region (in a three dimensional example) such as a plateau, where all the surrounding points are of very nearly the same fitness. If there are multiple peaks in close proximity, all of nearly the same fitness but with very deep divides, the algorithm will have trouble 'hopping' from one to the other. One way to overcome these obstacles is to scale the fitness values given by the fitness function, thereby gently modifying the fitness function from the point of view of the algorithm, thus rewarding the more fit solutions to a higher precision than would naturally occur. Four such scaling methods will be compared based upon their handling of a sample set of optical processing data. Success will be determined by comparing the variance over time, selection pressure over time, and best of generation graphs.
- 22 October 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5557, 356-364
Comparison of fitness scaling functions in genetic algorithms with applications to optical processing
Many optical or image processing tasks reduce to the optimization of some set of parameters. Genetic algorithms can optimize these parameters even when the functions they map are fairly complicated, but they can only do so the point where the fitness functions they are given can differentiate between good results and the best result. This can occur when the optimal point is in a region (in a three dimensional example) such as a plateau, where all the surrounding points are of very nearly the same fitness. If there are multiple peaks in close proximity, all of nearly the same fitness but with very deep divides, the algorithm will have trouble 'hopping' from one to the other. One way to overcome these obstacles is to scale the fitness values given by the fitness function, thereby gently modifying the fitness function from the point of view of the algorithm, thus rewarding the more fit solutions to a higher precision than would naturally occur. Four such scaling methods will be compared based upon their handling of a sample set of optical processing data. Success will be determined by comparing the variance over time, selection pressure over time, and best of generation graphs.
- 21 June 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6, 3659-3661
Measures of effectiveness and their use in comparative image fusion analysis
- 21 June 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6, 3659-3661
Measures of effectiveness and their use in comparative image fusion analysis