Vitaliano Gomes Araújo-Neto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Vitaliano Gomes Araújo-Neto has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Marcelo Giannini
Department of Restorative Dentistry, Piracicaba Dental School University of Campinas Piracicaba São Paulo Brazil
16 shared publications - Victor Pinheiro Feitosa
University of Iowa, USA
7 shared publications - Carolina Bosso André
Federal University of Minas Gerais, Brazil
6 shared publications Marcelo Giannini
Department of Restorative Dentistry, Piracicaba Dental School University of Campinas Campinas Brazil
4 shared publications- Tainah Oliveira Rifane
Paulo Picanço School of Dentistry Fortaleza Ceará Brazil
4 shared publications - Anna Caroliny Detogni
Department of Restorative Dentistry, Piracicaba Dental School University of Campinas Campinas Brazil
3 shared publications
Latest Publications
- 16 November 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Effect of Resin Cement Type, Root Canal Depth, and Aging on the Push‐Out Bond Strength of Fiberglass Posts Cemented to Intraradicular Dentin
Objective: To evaluate the influence of cementing system, root canal depth, and storage time on the push‐out bond strength (POBS) of fiberglass posts to intraradicular dentin. Methods: One hundred and eighty standardized bovine roots were prepared with a 2‐mm‐diameter helical drill. Fiberglass posts were cemented using six systems ( n = 15): Super‐Bond + M&C Primer (SUBO), Estecem Plus II + Universal Bond II (ESTE), Set PP (SETP), Stela + Stela Primer (STEL), Panavia V5 + Tooth Primer (PANA), and RelyX Universal + Scotchbond Universal Plus (REUN). Specimens were stored in water for 24 h or 18 months and sectioned into 2‐mm‐thick slices from the cervical, middle, and apical thirds for POBS testing. Data were analyzed using generalized linear models and Bonferroni‐adjusted comparisons ( α = 0.05). Results: At 24 h, POBS did not differ among cementing systems, regardless of root third. After 18 months, SUBO, PANA, and REUN maintained their POBS, showed no differences among root thirds, and outperformed SETP and STEL. Conclusion: Cementing systems performed similarly at 24 h, but not all maintained stable POBS after 18 months.
- 16 November 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Effect of Resin Cement Type, Root Canal Depth, and Aging on the Push‐Out Bond Strength of Fiberglass Posts Cemented to Intraradicular Dentin
Objective: To evaluate the influence of cementing system, root canal depth, and storage time on the push‐out bond strength (POBS) of fiberglass posts to intraradicular dentin. Methods: One hundred and eighty standardized bovine roots were prepared with a 2‐mm‐diameter helical drill. Fiberglass posts were cemented using six systems ( n = 15): Super‐Bond + M&C Primer (SUBO), Estecem Plus II + Universal Bond II (ESTE), Set PP (SETP), Stela + Stela Primer (STEL), Panavia V5 + Tooth Primer (PANA), and RelyX Universal + Scotchbond Universal Plus (REUN). Specimens were stored in water for 24 h or 18 months and sectioned into 2‐mm‐thick slices from the cervical, middle, and apical thirds for POBS testing. Data were analyzed using generalized linear models and Bonferroni‐adjusted comparisons ( α = 0.05). Results: At 24 h, POBS did not differ among cementing systems, regardless of root third. After 18 months, SUBO, PANA, and REUN maintained their POBS, showed no differences among root thirds, and outperformed SETP and STEL. Conclusion: Cementing systems performed similarly at 24 h, but not all maintained stable POBS after 18 months.
- Open Access
- 29 October 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Evaluation of the Integrity of Ceramic Laminates After Adhesive Cementation
Objectives: This study evaluated the effects of resin‐based materials on crack occurrence in ceramic laminate veneers (CLVs) after adhesive cementation. Additionally, the polymerization shrinkage stress (PSS) and maximum polymerization rate (MPR) of the resin‐based materials were determined. Materials and Methods: Four resin‐based materials were used as luting agents: Variolink Esthetic LC (Ivoclar), SDR Plus (Dentsply), heated Z100 (69°C, Solventum), and heated VisCalor Bulk (65°C, Voco). Twenty‐eight prepared premolars received CLVs ( n = 7). CLV integrity was assessed by transillumination and scanning electron microscopy. PSS was measured in a universal testing machine and MPR by FTIR spectroscopy ( n = 5). Data were analyzed by one‐way ANOVA and Tukey's test ( α = 0.05). Results: No CLV cracks were detected. VisCalor Bulk showed the lowest PSS (74.2 ± 15.3 MPa) and Variolink Esthetic LC the highest (135.4 ± 8.4 MPa) and the highest MPR (15.5%/s ± 2.3%/s). SDR Plus presented the lowest (10.0%/s ± 1.2%/s). Conclusions: The type of luting agent did not influence crack formation in CLVs. The PSS and MPR varied among materials.
- 29 October 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Open AccessEvaluation of the Integrity of Ceramic Laminates After Adhesive Cementation
Objectives: This study evaluated the effects of resin‐based materials on crack occurrence in ceramic laminate veneers (CLVs) after adhesive cementation. Additionally, the polymerization shrinkage stress (PSS) and maximum polymerization rate (MPR) of the resin‐based materials were determined. Materials and Methods: Four resin‐based materials were used as luting agents: Variolink Esthetic LC (Ivoclar), SDR Plus (Dentsply), heated Z100 (69°C, Solventum), and heated VisCalor Bulk (65°C, Voco). Twenty‐eight prepared premolars received CLVs ( n = 7). CLV integrity was assessed by transillumination and scanning electron microscopy. PSS was measured in a universal testing machine and MPR by FTIR spectroscopy ( n = 5). Data were analyzed by one‐way ANOVA and Tukey's test ( α = 0.05). Results: No CLV cracks were detected. VisCalor Bulk showed the lowest PSS (74.2 ± 15.3 MPa) and Variolink Esthetic LC the highest (135.4 ± 8.4 MPa) and the highest MPR (15.5%/s ± 2.3%/s). SDR Plus presented the lowest (10.0%/s ± 1.2%/s). Conclusions: The type of luting agent did not influence crack formation in CLVs. The PSS and MPR varied among materials.
- Open Access
- 28 October 2026
- Published by Elsevier in Dental Materials
Influence of non-thermal atmospheric plasma on the mechanical properties and phase stability of zirconia ceramics
- 28 October 2026
- Published by Elsevier in Dental Materials
Open AccessInfluence of non-thermal atmospheric plasma on the mechanical properties and phase stability of zirconia ceramics
- 6 June 2026
- Published by Elsevier in Dental Materials
- Vol. 42 (11) , 2097-2107
Comparison of methods for evaluating interfacial fracture toughness and bond strength of adhesives to dentin
- 6 June 2026
- Published by Elsevier in Dental Materials
- Vol. 42 (11) , 2097-2107
Comparison of methods for evaluating interfacial fracture toughness and bond strength of adhesives to dentin
- Open Access
- 31 May 2026
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 51 (2)
Effect of high irradiance and short exposure curing time on the fracture toughness of bulk-fill resin-based composite: an in vitro study
Effect of high irradiance and short exposure curing time on the fracture toughness of bulk-fill resin-based composite: an in vitro study
- 31 May 2026
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 51 (2)
Open AccessEffect of high irradiance and short exposure curing time on the fracture toughness of bulk-fill resin-based composite: an in vitro study
Effect of high irradiance and short exposure curing time on the fracture toughness of bulk-fill resin-based composite: an in vitro study
- 24 April 2026
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 149
Adhesive performance of a universal adhesive using the quick technique on dentin: In vitro study
- 24 April 2026
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 149
Adhesive performance of a universal adhesive using the quick technique on dentin: In vitro study
- 28 March 2026
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 40 (22) , 3837-3852
Long-term enhancement of bond strength to zirconia using a modified tribochemical treatment
- 28 March 2026
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 40 (22) , 3837-3852
Long-term enhancement of bond strength to zirconia using a modified tribochemical treatment
- 20 January 2025
- Published by Elsevier in Ceramics International
- Vol. 51 (11) , 14957-14965
Bond strength and chemical interaction between experimental primers containing 10-MDP and zirconia ceramics
- 20 January 2025
- Published by Elsevier in Ceramics International
- Vol. 51 (11) , 14957-14965
Bond strength and chemical interaction between experimental primers containing 10-MDP and zirconia ceramics