HYHuan Yao

Huan Yao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Huan Yao has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Coupling Supercritical Fluid Chromatography with Internal Standard Corrected Quantitative NMR for Rapid and Accurate Purity Assessment

    by Huan Yao, Ting Huang, Zhifang Li, Huaxin Wu, Xueyao Li, Hua Tang, Fuhai Su, Xinliang Jin, Wei Zhang

    Purity assessment is critical for the quality control of active pharmaceutical ingredients (APIs). However, there is a lack of rapid and accurate purity assessment methods that operate independently of target-specific certified reference materials (CRMs). Herein, we proposed a traceable quantification method, named SFC-ISC-qNMR, for purity assessment and quantitative determination of low-purity APIs, which was accomplished by tracing the test solution to the reference solution via supercritical fluid chromatography (SFC) collection with internal standard-correction (ISC), followed by an SI-traceable quantitative nuclear magnetic resonance (qNMR) analysis of the reference solution (SI = International System of Units). Digitoxin, a widely used cardiac glycoside in the treatment of heart failure and arrhythmias, was used as a model compound. By employing a mobile phase of supercritical CO2 modified with 24%-26% methanol, digitoxin with a purity exceeding 99.87% was isolated and collected. A national CRM of ethyl para-hydroxybenzoate was used as the IS for digitoxin. The SFC-ISC reference solution can be prepared in 15 min without the need for precise weighing, simply by reconstitution of the SFC collected high-purity analyte in deuterated methanol containing IS. The feasibility and reliability of the SFC-ISC-qNMR method were exhibited through the quantitative determination of digitoxin in chemical mixtures. The purity of a commercially available digitoxin reagent was determined to be 94.17% ± 0.15%, which was consistent with high-resolution qNMR analysis. The contents of spiked digitoxin in a digoxin analytical standard were measured at 1.06%, 1.37%, 2.39%, and 4.43%, respectively, showing high consistency with the gravimetric value with a bias less than 0.13%. In contrast, direct qNMR with deconvolution and HPLC analysis failed to provide accurate measurements. These results highlight the applicability of the SFC-ISC-qNMR method for drug evaluation and research, demonstrating its significant potential for the purity assessment of APIs.


  • High-Throughput Metabolite Analysis of Unicellular Microalgae by Orthogonal Hybrid Ionization Label-Free Mass Cytometry

    by Huan Yao, Jinlei Yang, Zhengmao Wang, Xingyu Pan, Junmin Pan, Hongmei Li, Sichun Zhang

    Microalgae metabolite analysis is fundamental for the rational design of metabolic engineering strategies for the biosynthesis of high-value products. Mass spectrometry (MS) has been utilized for single-cell microalgae analysis. However, limitations in the detection throughput and polarities of detectable substances make it difficult to realize high-throughput screening of high-performance microalgae. Herein, a plasma-assisted label-free mass cytometry, named as PACyESI-MS, was proposed combining the advantages of orthogonal hybrid ionization and high-throughput MS analysis, which realized rapid metabolite detection of single microalgae. The cell detection throughput of PACyESI-MS was up to 52 cells/min. Dozens of the critical primary and secondary metabolites within single microalgae were detected simultaneously, including pigments, lipids, and energy metabolites. Furthermore, metabolite changes of Chlamydomonas reinhardtii and Haematococcus pluvialis under nitrogen deficiency stress were studied. Discrimination of Chlamydomonas under different nutrient conditions was realized using single-cell metabolite profiles obtained by PACyESI-MS. The relationships between the accumulation of bioactive astaxanthin and changes in functional primary metabolites of Haematococcus were investigated. It was demonstrated that PACyESI-MS can detect the flexible change of metabolites in single microalgae cells under different nutritional conditions and during the synthesis of high-value products, which is expected to become an important tool for the design of metabolic engineering-based high-performance microalgae factories.


  • Single-Cell Unsaturated Lipid Profiling for Studying Chemoresistance Heterogeneity of Triple-Negative Breast Cancer Cells

    by Jinlei Yang, Runsong Cheng, Xingyu Pan, Siyuan Pan, Murong Du, Huan Yao, Zhian Hu, Sichun Zhang, Xinrong Zhang

    Chemoresistance to triple-negative breast cancer (TNBC) is a critical issue in clinical practice. Lipid metabolism takes a unique role in breast cancer cells; especially, unsaturated lipids involving cell membrane fluidity and peroxidation are highly remarked. At present, for the lack of a high-resolution molecular recognition platform at the single-cell level, it is still hard to systematically study chemoresistance heterogeneity based on lipid unsaturation proportion. By designing a single-cell mass spectrometry workflow based on CyESI-MS, we profiled the unsaturated lipids of TNBC cells to evaluate lipidomic remodeling under platinum stress. Profiling revealed the heterogeneity of the polyunsaturated lipid proportion of TNBC cells under cisplatin treatment. A cluster of cells identified by polyunsaturated lipid accumulation was found to be involved in platinum sensitivity. Furthermore, we found that the chemoresistance of TNBC cells could be regulated by fatty acid supplementation, which determinates the composition of unsaturated lipids. These discoveries provide insights for monitoring and controlling cellular unsaturated lipid proportions to overcome chemoresistance in breast cancer.


  • Covalent Organic Framework Nanosheets for Fluorescence Quantification of Peptide

    by Huan Yao, Yongliang Yang, Siyuan Pan, Rong Zhao, Yaqi Cai, Sichun Zhang, Hongmei Li

    Rapid and sensitive quantification of peptides plays an important role in clinical diagnosis. Fluorescence assay is one of the most promising peptide detection tools, but it relies on intrinsic fluorescence or additional derivatization, resulting in poor versatility. Covalent organic frameworks (COFs) have shown a good application prospect in the field of fluorescence detection, but their application scope is limited to heavy metal ions and some small polar organic molecules. Herein, we report the application of COFs nanosheet for fluorescence detection of peptides. Fluorescent sp2 acrylonitrile-linked COFs nanosheets (TTAN-CON) were prepared by water-assisted ultrasonic exfoliation which performed with excellent fluorescence properties with Stokes shifts of 146 nm and fluorescence quantum yield of up to 24.45%. Compared to the bulk fluorescent COFs, exfoliated CONs films performed with better stability of fluorescence signal in solution. We found the fluorescence of TTAN-CON can be effectively quenched by hydrophobic peptides at a very rapid rate (less than 5 min per sample). TTAN-CON presented good sensitivity and selectivity for hydrophobic peptides detection via the static and dynamic joint quenching mechanism. TTAN-CON was further used to detect NLLGLIEAK and ProGRP31-98, two target peptide fragments of lung cancer biomarker ProGRP. The fluorescence intensities of TTAN-CON were negative linearly correlated with the amounts of hydrophobic NLLGLIEAK over the range of 5-1000 ng/mL with the correlation coefficients over 0.99, and the limit of detection was 1.67 ng/mL, displaying higher sensitivity and convenience than traditional optical methods. What's more, the quantification of ProGRP31-98 was achieved by the quantification of hydrophobic peptides in its enzyme hydrolysis products. We anticipate COFs nanosheets to be a universal fluorescence detection work-box for peptides biomarkers with clinical significance.


  • Label-free Mass Cytometry for Unveiling Cellular Metabolic Heterogeneity

    by Huan Yao, Hansen Zhao, Xu Zhao, Xingyu Pan, Jiaxin Feng, Fujian Xu, Sichun Zhang, Xinrong Zhang

    Comprehensive analysis of single-cell metabolites is critical since differences in cellular chemical compositions give rise to specialized biological functions. Herein, we propose a label-free mass cytometry by coupling flow cytometry to ESI-MS (named CyESI-MS) for high-coverage and high-throughput detection of cellular metabolites. Cells in suspension were isolated, online extracted by sheath fluid, lysed during gas-assisted electrospray and followed by real-time MS analysis. Hundreds of metabolites, including nucleotides, amino acids, peptides, carbohydrates, fatty acyls, glycerolipids, glycerophospholipids and sphingolipids, were detect-ed and identified from one single cell. Discrimination of four types of cancer cell lines, and even three subtypes of breast cancer cells were readily achieved using their distinct metabolic profiles. Furthermore, we screened out 102 characteristic ions from 615 detected peak signals for distinguishing breast cancer cell subtypes and identified 40 characteristic molecules which exhibited significant differences among these subtypes and would be potential metabolic markers for clinical diagnosis. CyESI-MS is expected to be a new-generation mass cytometry for studying cell heterogeneity on the metabolic level.