ESEnes Senel

Enes Senel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Enes Senel has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Benchmarking single-cell foundation models for real-world RNA-seq data integration

    by Siyu Han, Tamas Sztanka-Toth, Enes Senel, Ahmed Elnaggar, Jaymala Patel, Tommaso Mansi, Denis Smirnov, Joel Greshock, Alex Javidi

    Single-cell foundation models enable reusable representations and streamlined analysis workflows, yet rigorous evaluation of their performance and robustness in real-world pharmaceutical settings remain underexplored. Here, we benchmarked leading single-cell foundation models (scGPT; scGPT_CP, a continually pretrained checkpoint of scGPT; scFoundation; scMulan; CellFM) against established baseline methods (scVI; Harmony) for data integration using over 1.5 million cells from clinical and preclinical samples. Performance was assessed using well-established and complementary metrics for technical correction and biological structure preservation. We further introduced robustness-oriented rankings to summarize metric trade-offs and quantify performance consistency across datasets and evaluation settings. Our findings show that fine-tuning improved technical correction performance; among the foundation models, fine-tuned scGPT_CP performed best. However, the baseline scVI was the top overall performer, ranking first by our multi-metric Leximax ranking and achieving the highest Pareto Front-1 hit. Collectively, our study provides practical insights for adapting foundation models to real-world drug design and development.


  • Open Access

    Benchmarking Next-Generation Sequencing Platforms: A Comprehensive Comparison Of Single-Cell RNA-Seq from Ultima UG 100 vs. Illumina NovaSeq X Plus

    by Ruoyun Xiong, Jaymala Patel, Tamas Sztanka-Toth, Enes Senel, Karl Calara-Nielsen, Yashoda Rajpurohit, Tom Altenburg, Joel Greshock, Denis Smirnov, Alex Javidi

    Single-cell RNA sequencing (scRNA-seq) has become an essential technology for dissecting cellular heterogeneity in complex biological systems, with Illumina platforms serving as the dominant NGS provider 1–3 . The recent emergence of the Ultima Genomics UG 100 platform offers a high-throughput and potentially more cost-effective alternative, warranting a rigorous comparative analysis. Here, we conducted a comprehensive head-to-head comparison of the Ultima Genomics UG 100 and Illumina NovaSeq X Plus platforms, generating deep-coverage scRNA-seq data from human PBMCs and stimulated T-cell samples. Our multi-level analysis revealed highly concordant performance in both cell type identification and gene expression. We found that both platforms robustly captured all major immune lineages and demonstrated good transcriptional agreement. Minor observed discrepancies were primarily correlated with low UMI counts, suggesting stochastic biological effects rather than technical variance. Overall, our study establishes that the Ultima UG 100 delivers performance highly comparable to the Illumina NovaSeq X Plus for single-cell transcriptomics.

  • Open Access

    Optocoder: computational decoding of spatially indexed bead arrays

    by Enes Senel, Nikolaus Rajewsky, Nikos Karaiskos

    Motivation Advancing technologies that quantify gene expression in space are transforming contemporary biology research. A class of spatial transcriptomics methods uses barcoded bead arrays that are optically decoded via microscopy and are later matched to sequenced data from the respective libraries. To obtain a detailed representation of the tissue in space, robust and efficient computational pipelines are required to process microscopy images and accurately basecall the bead barcodes. Results Optocoder is a computational framework that processes microscopy images to decode bead barcodes in space. It efficiently aligns images, detects beads, and corrects for confounding factors of the fluorescence signal, such as crosstalk and phasing. Furthermore, Optocoder employs supervised machine learning to strongly increase the number of matches between optically decoded and sequenced barcodes. We benchmark Optocoder using data from an in-house spatial transcriptomics platform, as well as from Slide-Seq(V2), and we show that it efficiently processes all datasets without modification. Availability Optocoder is publicly available, open-source and provided as a stand-alone Python package on GitHub: https://github.com/rajewsky-lab/optocoder


  • Visual needle tip tracking in 2D US guided robotic interventions

    by Mert Kaya, Enes Senel, Awais Ahmad, Ozkan Bebek


  • Visual tracking of multiple moving targets in 2D ultrasound guided robotic percutaneous interventions

    by Mert Kaya, Enes Senel, Awais Ahmad, Ozkan Bebek

    Percutaneous needle procedures are mostly carried out with the guidance of 2D ultrasound (US) imaging. US images are inherently noisy and their resolutions are low. Hence, target tracking can be challenging. Image based tracking methods can be used to track the needle and the target. This paper proposes visual tracking of multiple moving points, such as biopsy needles and targets, in 2D US images using normalized cross correlation and mutual information similarity functions. Both moving and deformable targets can be tracked. An affine motion model is used for small and moving target tracking and a thin plate spline motion model is used for deformable target tracking. During the tracking, needle and target template images are updated with a template update strategy. Also, tracking outputs of normalized cross correlation and mutual information are fused using the Kalman filter to reduce the tracking error. During the experiments, needle is inserted using a needle insertion robot. 2D US probe is attached to a robotic arm's end effector to servo the probe along the needle insertion path. Proposed needle and target tracking methods were tested with phantoms. Accuracies of the needle tip and moving target tracking methods were measured using an optical tracking system. Experimental results showed that the proposed tracking method could be used to simultaneously track the needle tip and the targets in real-time in 2D US guided percutaneous needle procedures.


  • Visual tracking of biopsy needles in 2D ultrasound images

    by Mert Kaya, Enes Senel, Awais Ahmad, Ozkan Bebek

    Ultrasound (US) is one the most commonly used medical imaging techniques in percutaneous needle procedures. However, US images are inherently noisy and contain excessive number of artifacts. Hence, it is not easy to track the needle tip in the US images during the needle insertions. At this point, image based visual tracking techniques can be used for needle tip tracking. This paper presents a method for visual tracking of biopsy needles in 2D US images using sum of squared differences and sum of conditional variances. Second order Gauss-Newton optimization is used to decrease processing time and make the tracking more robust. The needle template images used in the method are updated with a strategy to prevent needle loss and detection failures during tracking. The paper also explains how to identify needle losses during tracking and how to recover the needle position without using a needle localization algorithm. We demonstrate the precision of the visual needle tip tracking method with experiments under challenging tracking conditions.


  • Real-time needle tip localization in 2D ultrasound images for robotic biopsies

    by Mert Kaya, Enes Senel, Awais Ahmad, Orcun Orhan, Ozkan Bebek

    In this paper, real-time needle tip tracking method using 2D ultrasound (US) images for robotic biopsies is presented. In this method, the needle tip is estimated with the Gabor filter based image processing algorithm, and the estimation noise is reduced with the Kalman filter. This paper also presents the needle tip tracking simulation to test accuracy of the Kalman filter under position misalignments and tissue deformations. In order to execute proposed method in real-time, the bin packing method is used and the processing time is reduced by 56%, without a GPU. The proposed method was tested in four different phantoms and water medium. The accuracy of the needle tip estimation was measured with optical tracking system, and root mean square error (RMS) of the tip position is found to be 1.17 mm. The experiments showed that the algorithm could track the needle tip in real-time.