Luminita Barote has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Establishing an Optimal Residential RES PV Source by Modelling

    by Luminita Barote, Corneliu Marinescu

    The analyzed Microgrid (MG) is implemented in the Research Centre of Transilvania University of Brasov Institute and consists in an 8 kW photovoltaic (PV) system, a grid connecting PV inverter of 4.6 kW and a 48V Li-ion stationary battery interfaced with the MG by a 6 kW inverter which provides around 20 kWh storage capacity. The main issue of this paper is to establishing by modeling, an optimal residential PV renewable energy source (RES), that provide for a given inverter the best energy production based on the solar potential from Brasov area. Simulations are accomplished in Homer Pro software in order to estimate the optimal PV power source to obtain a maximum amount of energy for a given PV system structure.


  • Dynamic Performance Analysis of a Photovoltaic Power Plant with Integrated Storage for Microgrids Dynamic Support

    by Daniel Munteanu, Ioan Serban, Luminita Barote, Corneliu Marinescu

    This paper presents a solution to improve the dynamic performance of the frequency-control process in autonomous microgrids by means of photovoltaic (PV) power plants. An energy storage system was integrated in the PV power plant primarily to enhance the power-control capability of the PV system. Because the the focus of this paper is on how the PV-storage system can provide dynamic frequency support in the microgrid, a frequency controller was added to the control scheme of the voltage source converter (VSC) that interfaced the PV power plant with the microgrid. The PV response to frequency deviations was adapted from the existing Romanian grid code and, according to the system’s characteristics, a modified power-frequency curve was proposed. The system being studied was examined through both simulations and experiments, and the results showed that, when the storage system was enabled, the PV power plant improved the microgrid’s dynamic frequency response.

  • Current-Controller Effectiveness for Grid-Connected Converters: Comparative Case Studies

    by Luminita Barote, Corneliu Marinescu

    This paper describes the implementation and comparison of two current-control strategies for a three-phase voltage source inverter (VSI) system grid connected via a LCL filter and used in distributed power generation systems (DPGS) applications. The performance of a proportional integrator (PI) current controller in the dq-synchronous reference frame and a proportional resonant (PR) controller in the αβ stationary reference frame are evaluated and compared. A voltage source (playing the role of a generic renewable energy source) is connected to the grid using a two-level inverter in order to verify the performance of the proposed approach. Both methods are implemented and tested at the laboratory-level using a dSPACE setup. The comparative study is performed to demonstrate the stability and effectiveness of the control algorithms across a wide range of operating conditions. The experimental results confirm that the proposed control achieves good current tracking, thus satisfying the grid-connection harmonics standards.


  • Open Access

    Enhancing with EV Charging Station Functions a Residential RES based Network

    by Corneliu Marinescu, Luminita Barote, Daniel Munteanu, Vitalijs Komasilovs, Aleksejs Zacepins, Armands Kviesis


  • Toward a practical solution for residential RES based EV charging system

    by C. Marinescu, L. Barote

    The world population depends highly on fossil fuels (for power generation, transportation, etc), this leads to oil price increases because of the depletion of fossil fuels. This paper is dealing with the use of RES in transportation. Pollution from the today transportation means, based on ICE (burning gas) especially in urban conglomerates and is off great concern. The renewable energy sources (RES) based microgrids (MGs) with energy storage facilities, can contribute to charge the future electric vehicles (EVs) based transportation system. Renewable energy charging stations can play a key role in the successful development and deployment of EVs contributing to pollution reduction, too. The proposed charging station is powered by renewable energy sources such as wind and photovoltaic used in hybrid configuration with energy storage system. The target of it is the residential application in future Smart cities. The storage system can contribute to V2G peak shaving and power quality functions. This study focused on a practical solution for residential RES based EV charging station.


  • Control of PV inverter with energy storage capacity to improve microgrid dynamic response

    by Daniel Munteanu, Corneliu Marinescu, Ioan Serban, Luminita Barote

    Achieving a high-level of stability represents one major concern in autonomous microgrids (MGs) with high penetration levels of renewable energy sources. The aim of this paper is to study how photovoltaic (PV) power plants can provide dynamic frequency support in an MG, in order to obtain an improved stability for the entire power system. On the PV side an energy storage subsystem is added, which ensures a better controllability and a higher power reserve for the PV power plant. To improve the dynamic frequency stability of the MG, specific functions are implemented within the PV inverter control. The proposed system is validated by means of simulation results.


  • PV-battery system with enhanced control for microgrid integration

    by Corneliu Marinescu, Luminita Barote, Daniel Munteanu

    With the development of Distributed Energy Systems the dynamic support of Microgrids Energy Quality is of great importance an optimized operating scheme for a grid-connected based photovoltaic (PV) system is analyzed. The proposed model comprises of a PV plant with lead acid batteries (LABs) Energy Storage coupled to the grid by means of a three-phase inverter (VSI). The PV plant and the battery storage are integrated with the help of dc-dc and dc-ac converters in such a way that bidirectional flow of active and reactive powers can be achieved. The required power for the connected loads can be effectively delivered and supplied by the proposed PV system and energy storage systems, subject to an appropriate control method. The ultimate goal of any power system is to maintain a balance between demand and supply of active and reactive power at any given point in time. Controllers integrating energy sources respond to the received signals and attempt to fulfill the grid demand. The system response is almost instantaneous and thus can be very helpful in grid frequency and voltage support. The grid voltage harmonic generation influences the current controller and generates current harmonics; the used compensator is effective for both positive and negative sequence fifth and seventh harmonics. Simulation tests validate the proposed analyzed control.


  • Reactive power influence on power quality for grid connected converter in DPGS applications

    by Luminita Barote, Corneliu Marinescu

    In this paper, the reactive power influence on power quality (especially THD - total harmonic distortion) for grid connected converter is investigated. This paper deals with the design and implementation of PI current control method in the dq synchronous reference frame for the grid side converter in DPGS (distributed power generation systems) applications. The goals of this paper are to test the reactive power influence on power quality for the grid side converter including a control method with LC filter, a compensation technique for low-order harmonics and to examine the grid current harmonic content with and without harmonic compensation. A comparative study in terms of current harmonic distortion between two different proportional gain values and of the PI controller running in steady state condition with different active/reactive power values is made through experiments. The analyzed structure was implemented and tested in laboratory using a dSPACE setup.

  • Control Structure for Single-Phase Stand-Alone Wind-Based Energy Sources

    by Luminita Barote, Corneliu Marinescu, Marcian N. Cirstea

    This paper is analyzing the operation of a stand-alone wind turbine system with variable-speed permanent-magnet synchronous generator (PMSG) and a system for storing energy during wind speed and load variations. Energy storage devices are required for power balance and power quality in stand-alone wind energy systems. Initially, the holistic model of the entire system is achieved, including the PMSG, the boost converter, and the storage system. The power absorbed by the connected loads can be effectively delivered and supplied by the proposed wind turbine and energy storage systems, subject to an appropriate control method. The main purpose is to supply 230-V/50-Hz domestic appliances through a single-phase inverter. The simulation results, validated by experimental testing, show a good prediction of the electrical parameter waveforms. The control system is implemented on a dSPACE DS1103 real-time board. Furthermore, the results confirm the stability of the supply.