David Schnerch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Schnerch has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Sami Rizkalla
Engineering Associate, Wiss, Janney, Elstner Associates, Inc., 245 First St., Ste. 1200, Cambridge, MA 02142-1292
4 shared publications- Mina Dawood
University of Houston
3 shared publications S. Rizkalla
3 shared publicationsE. Sumner
Constructed Facilities Laboratory, North Carolina State University, 2414 Campus Shore Dr., Campus Box 7533, Raleigh, NC 27695-7533, United States
2 shared publicationsA. Z. Fam
Department of Civil Engineering, Queen's University, Kingston, Ontario, K7L 3N6, Canada
1 shared publication- Amir Fam
Queen’s Univ
1 shared publication
Latest Publications
- 1 June 2017
- Published by ASTM International
- p. 1-17
Lap Weld Strength of Reinforced Concrete Pipe Cages
ASTM C76, Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe, and ASTM C1417, Standard Specification for Manufacture of Reinforced Concrete Sewer, Storm Drain, and Culvert Pipe for Direct Design, specify the requirements for reinforced concrete pipe, including the requirements for cage reinforcing welded lap splices. A discrepancy in the pull test requirement for welded lap splices existed between the 2008 versions of both specifications until ASTM C1417-11 was revised to mirror ASTM C76-08. ASTM C76-08 required pull tests of representative specimens to develop at least 50 % of the minimum specified tensile strength (or ultimate strength) of the steel. ASTM C1417-08 specified that pull tests of representative specimens develop no less than 0.9 times (or 90 %) the design yield strength of the circumferential. This discrepancy raised questions when ASTM C1417-08 was revised as to how the required lap splice strength of 90 % of the yield strength was established for ASTM C1417-08 and concern that this might be a more appropriate requirement. Therefore, the concrete pipe industry produced and tested 24-in. and 36-in. diameter pipe in which the welded lap splices did not meet the ASTM C76 requirement of 50 % ultimate strength in order to demonstrate that this requirement does not affect the final three-edge bearing product test results.
- 1 June 2017
- Published by ASTM International
- p. 1-17
Lap Weld Strength of Reinforced Concrete Pipe Cages
ASTM C76, Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe, and ASTM C1417, Standard Specification for Manufacture of Reinforced Concrete Sewer, Storm Drain, and Culvert Pipe for Direct Design, specify the requirements for reinforced concrete pipe, including the requirements for cage reinforcing welded lap splices. A discrepancy in the pull test requirement for welded lap splices existed between the 2008 versions of both specifications until ASTM C1417-11 was revised to mirror ASTM C76-08. ASTM C76-08 required pull tests of representative specimens to develop at least 50 % of the minimum specified tensile strength (or ultimate strength) of the steel. ASTM C1417-08 specified that pull tests of representative specimens develop no less than 0.9 times (or 90 %) the design yield strength of the circumferential. This discrepancy raised questions when ASTM C1417-08 was revised as to how the required lap splice strength of 90 % of the yield strength was established for ASTM C1417-08 and concern that this might be a more appropriate requirement. Therefore, the concrete pipe industry produced and tested 24-in. and 36-in. diameter pipe in which the welded lap splices did not meet the ASTM C76 requirement of 50 % ultimate strength in order to demonstrate that this requirement does not affect the final three-edge bearing product test results.
- 1 January 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 15 (1) , 118
Closure to “Flexural Strengthening of Steel Bridges with High Modulus CFRP Strips” by David Schnerch and Sami Rizkalla
- 1 January 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 15 (1) , 118
Closure to “Flexural Strengthening of Steel Bridges with High Modulus CFRP Strips” by David Schnerch and Sami Rizkalla
- 1 October 2009
- Published by Elsevier in Thin-Walled Structures
- Vol. 47 (10) , 1037-1047
Behavior of steel monopoles strengthened with high-modulus CFRP materials
- 1 October 2009
- Published by Elsevier in Thin-Walled Structures
- Vol. 47 (10) , 1037-1047
Behavior of steel monopoles strengthened with high-modulus CFRP materials
- 1 March 2008
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 13 (2) , 192-201
Flexural Strengthening of Steel Bridges with High Modulus CFRP Strips
Acceptance of carbon fiber-reinforced polymer (CFRP) materials for strengthening concrete structures, together with the recent availability of higher modulus CFRP strips, has resulted in the possibility to also strengthen steel structures. Steel bridge girders and building frames may require strengthening due to corrosion induced cross-section losses or changes in use. An experimental study investigating the feasibility of different strengthening approaches was conducted. Large-scale steel-concrete composite beams, typical of bridge structures, were used to consider the effect of CFRP modulus, prestressing of the CFRP strips, and splicing finite lengths of CFRP strips. All of the techniques examined were effective in utilizing the full capacity of the CFRP material, and increasing the elastic stiffness and ultimate strength of the beams. Results of the experimental program were compared to an analytical model that requires only the beam geometry and the constitutive properties of the CFRP, steel, and conc...
- 1 March 2008
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 13 (2) , 192-201
Flexural Strengthening of Steel Bridges with High Modulus CFRP Strips
Acceptance of carbon fiber-reinforced polymer (CFRP) materials for strengthening concrete structures, together with the recent availability of higher modulus CFRP strips, has resulted in the possibility to also strengthen steel structures. Steel bridge girders and building frames may require strengthening due to corrosion induced cross-section losses or changes in use. An experimental study investigating the feasibility of different strengthening approaches was conducted. Large-scale steel-concrete composite beams, typical of bridge structures, were used to consider the effect of CFRP modulus, prestressing of the CFRP strips, and splicing finite lengths of CFRP strips. All of the techniques examined were effective in utilizing the full capacity of the CFRP material, and increasing the elastic stiffness and ultimate strength of the beams. Results of the experimental program were compared to an analytical model that requires only the beam geometry and the constitutive properties of the CFRP, steel, and conc...
- 1 February 2008
- Published by Elsevier in Composites Part A: Applied Science and Manufacturing
- Vol. 39 (2) , 388-397
Development of a carbon fiber reinforced polymer system for strengthening steel structures
- 1 February 2008
- Published by Elsevier in Composites Part A: Applied Science and Manufacturing
- Vol. 39 (2) , 388-397
Development of a carbon fiber reinforced polymer system for strengthening steel structures
- 1 May 2007
- Published by Elsevier in Construction and Building Materials
- Vol. 21 (5) , 1001-1010
Proposed design guidelines for strengthening of steel bridges with FRP materials
- 1 May 2007
- Published by Elsevier in Construction and Building Materials
- Vol. 21 (5) , 1001-1010
Proposed design guidelines for strengthening of steel bridges with FRP materials
- 1 December 2006
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 9 (6) , 805-817
Bond Behavior of CFRP Strengthened Steel Structures
Recent research has focused on rehabilitation and strengthening of steel structures and bridges using fiber reinforced polymer (FRP) materials. The bond behavior of FRP materials to steel structures is quite different from that of concrete structures. Preliminary test results showed the occurrence of very high bond stresses for most strengthening applications due to the amount of strengthening required for steel structures and bridges. In this paper, surface preparation methods and means of preventing galvanic corrosion are discussed. The results of an experimental program for selection of suitable adhesives through determination of the development length is discussed as well as preliminary testing showing the importance of proper detailing of the ends of the FRP strips. The shear stress distribution determined in the experimental program is compared to analytical models using a stress-based approach. The remainder of the paper focuses on the current methods for determining bond stresses and their use for the design of FRP strengthening system for steel structures.
- 1 December 2006
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 9 (6) , 805-817
Bond Behavior of CFRP Strengthened Steel Structures
Recent research has focused on rehabilitation and strengthening of steel structures and bridges using fiber reinforced polymer (FRP) materials. The bond behavior of FRP materials to steel structures is quite different from that of concrete structures. Preliminary test results showed the occurrence of very high bond stresses for most strengthening applications due to the amount of strengthening required for steel structures and bridges. In this paper, surface preparation methods and means of preventing galvanic corrosion are discussed. The results of an experimental program for selection of suitable adhesives through determination of the development length is discussed as well as preliminary testing showing the importance of proper detailing of the ends of the FRP strips. The shear stress distribution determined in the experimental program is compared to analytical models using a stress-based approach. The remainder of the paper focuses on the current methods for determining bond stresses and their use for the design of FRP strengthening system for steel structures.
- 1 February 2005
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 9 (1) , 25-33
Rectangular Filament-Wound Glass Fiber Reinforced Polymer Tubes Filled with Concrete under Flexural and Axial Loading: Experimental Investigation
This paper presents results of an experimental investigation on three beams and five short columns, consisting of glass fiber reinforced polymer concrete-filled rectangular filament-wound tubes (CFRFTs). The tubes included fibers oriented at ±45 ° and 90° with respect to the longitudinal axis. Additional longitudinal fibers [0°] were provided in flanges for flexural rigidity. Beams included totally filled tubes and a tube partially filled with concrete, which had a central hole for reducing deadweight. The effect of reinforcement ratio was examined by using tubes of two different sizes. Flexural behavior of CFRFT was compared to concrete-filled rectangular steel tubes (CFRSTs) of similar reinforcement ratios. Short columns were tested under eccentricity ratios (e∕h) of 0, 0.09, 0.18, and 0.24, where h is the section depth. Transverse strains were measured around the perimeter of concentrically loaded column to evaluate confinement effect. The study showed that CFRFT is a feasible system that could offer s...
- 1 February 2005
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 9 (1) , 25-33
Rectangular Filament-Wound Glass Fiber Reinforced Polymer Tubes Filled with Concrete under Flexural and Axial Loading: Experimental Investigation
This paper presents results of an experimental investigation on three beams and five short columns, consisting of glass fiber reinforced polymer concrete-filled rectangular filament-wound tubes (CFRFTs). The tubes included fibers oriented at ±45 ° and 90° with respect to the longitudinal axis. Additional longitudinal fibers [0°] were provided in flanges for flexural rigidity. Beams included totally filled tubes and a tube partially filled with concrete, which had a central hole for reducing deadweight. The effect of reinforcement ratio was examined by using tubes of two different sizes. Flexural behavior of CFRFT was compared to concrete-filled rectangular steel tubes (CFRSTs) of similar reinforcement ratios. Short columns were tested under eccentricity ratios (e∕h) of 0, 0.09, 0.18, and 0.24, where h is the section depth. Transverse strains were measured around the perimeter of concentrically loaded column to evaluate confinement effect. The study showed that CFRFT is a feasible system that could offer s...
- 1 January 2004
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 1892 (1) , 237-245
Strengthening Steel Structures and Bridges with High-Modulus Carbon Fiber-Reinforced Polymers Resin Selection and Scaled Monopole Behavior
Cost-effective solutions for the rehabilitation and strengthening of steel structures, including bridges and monopole towers, are greatly needed. Rehabilitation is often required because of cross-section losses occurring as a result of corrosion; strengthening may also be required because of changes in the use of a structure. Current techniques for strengthening steel structures have several drawbacks, including their fatigue performance and the need for ongoing maintenance owing to continued corrosion attack. The current research program makes use of a high-modulus carbon fiber for the strengthening of steel structures. This program, currently in progress, includes phases for the resin and adhesive selection for wet layup of carbon fiber sheets and bonding of precured laminate plates. Test results of the first scaled monopole tower showed a 25% increase in stiffness in the elastic range compared with the same monopole before strengthening.
- 1 January 2004
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 1892 (1) , 237-245
Strengthening Steel Structures and Bridges with High-Modulus Carbon Fiber-Reinforced Polymers Resin Selection and Scaled Monopole Behavior
Cost-effective solutions for the rehabilitation and strengthening of steel structures, including bridges and monopole towers, are greatly needed. Rehabilitation is often required because of cross-section losses occurring as a result of corrosion; strengthening may also be required because of changes in the use of a structure. Current techniques for strengthening steel structures have several drawbacks, including their fatigue performance and the need for ongoing maintenance owing to continued corrosion attack. The current research program makes use of a high-modulus carbon fiber for the strengthening of steel structures. This program, currently in progress, includes phases for the resin and adhesive selection for wet layup of carbon fiber sheets and bonding of precured laminate plates. Test results of the first scaled monopole tower showed a 25% increase in stiffness in the elastic range compared with the same monopole before strengthening.
- 6 June 2003
- Published by World Scientific Pub Co Pte Ltd
- p. 685-694
RECTANGULAR FRP TUBES FILLED WITH CONCRETE FOR BEAM AND COLUMN APPLICATIONS
- 6 June 2003
- Published by World Scientific Pub Co Pte Ltd
- p. 685-694
RECTANGULAR FRP TUBES FILLED WITH CONCRETE FOR BEAM AND COLUMN APPLICATIONS