Thao Nguyen-Tran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thao Nguyen-Tran has a total of 118 co-authors. Here are the top co-authors by number of shared publications:
- Steffany A. L. Bennett
University of Ottawa
6 shared publications Irina Alecu
Neural Regeneration Laboratory, Ottawa Institute of Systems Biology, Ottawa Brain and Mind Research Institute, Department of Biochemistry, Microbiology, and Immunology, and Department of Chemistry, Centre for Catalysis Research and Innovation, University of Ottawa, Ottawa, Canada
3 shared publications- Theodore J. Perkins
Ottawa Institute of Systems Biology, Department of Biochemistry, Microbiology and Immunology, University of Ottawa, 451 Smyth Road, Ottawa, ON, K1H 8M5, Canada
3 shared publications Anuradha Surendra
National Research Council of Canada, Digital Technologies Research Centre , Ottawa, Ontario, Canada
2 shared publicationsHongbin Xu
Neural Regeneration Laboratory and India Taylor Lipidomics Research Platform, University of Ottawa Brain and Mind Research Institute , Ottawa, ON K1H 8M5, Canada
2 shared publications- Miroslava Cuperlovic-Culf
Digital Technologies Research Centre, National Research Council of Canada
2 shared publications
Latest Publications
- Open Access
Desktop iDMS: A stand-alone application of intelligent differential mobility spectrometry (iDMS), a neural network that predicts optimal separation and compensation voltages for field asymmetric differential ion mobility spectrometry
Summary: Mass spectrometry resolution of glycosphingolipids requires advanced separation methods. The virtually identical structures of glycolipid epimers cannot be discriminated by routine multiple reaction monitoring-high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (MRM-LC-ESI-MS/MS). Separation can be achieved using field asymmetric (differential) ion mobility mass spectrometry (FAIMS/DMS). A major bottleneck to MRM-LC-ESI-DMS-MS/MS method development lies in manually optimizing the compound-dependent parameters of separation voltage (SV) and compensation voltage (CoV). To address this challenge, we developed intelligent Differential Mobility Spectrometry (iDMS). iDMS is a supervised deep neural network that evaluates and predicts the optimal ion mobility SV and CoV parameters for any user-requested monoglycosphingolipid from a training set of measured signal intensities composed of 12 lipids (6 stereoisomer pairs). We initially introduced iDMS as a series of python scripts. Here, we share desktop applications of both iDMS and its pre-processing input data assembly modules (DMS Data Extraction Toolkit). Both software assemblies enable users to rapidly deploy a validated machine learning alternative to manual DMS optimization. The applications are user-friendly, operate without need for any technical operating environment, make training dataset assembly quick and simple, and return measured, normalized, and predicted ionograms at every user-interrogated SV, evaluation of separability at each SV and CoV combination, and prediction of optimal resolution parameters to accelerate users’ MRM-LC-ESI-DMS-MS/MS deployment. Availability and implementation: Desktop iDMS and DMS Data Extraction Toolkit are native desktop applications for macOS (Apple Silicon), freely available for download at https://www.neurolipidomics.com/platforms.html under the GNU v3.0 license. The source code is available from GitHub and Zenodo at https://github.com/Neurolipidomics/iDMS , https://zenodo.org/records/22214408 , https://github.com/Neurolipidomics/DMSDataExtractionToolkit , and https://ze-nodo.org/records/22777403 . Benchmarking metrics are available at https://www.biorxiv.org/content/10.64898/2026.08.26.747394v1 . Contact: ldomic@uottawa.ca Supplementary Information: Supplementary material is available at Bioinformatics online.
Open AccessDesktop iDMS: A stand-alone application of intelligent differential mobility spectrometry (iDMS), a neural network that predicts optimal separation and compensation voltages for field asymmetric differential ion mobility spectrometry
Summary: Mass spectrometry resolution of glycosphingolipids requires advanced separation methods. The virtually identical structures of glycolipid epimers cannot be discriminated by routine multiple reaction monitoring-high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (MRM-LC-ESI-MS/MS). Separation can be achieved using field asymmetric (differential) ion mobility mass spectrometry (FAIMS/DMS). A major bottleneck to MRM-LC-ESI-DMS-MS/MS method development lies in manually optimizing the compound-dependent parameters of separation voltage (SV) and compensation voltage (CoV). To address this challenge, we developed intelligent Differential Mobility Spectrometry (iDMS). iDMS is a supervised deep neural network that evaluates and predicts the optimal ion mobility SV and CoV parameters for any user-requested monoglycosphingolipid from a training set of measured signal intensities composed of 12 lipids (6 stereoisomer pairs). We initially introduced iDMS as a series of python scripts. Here, we share desktop applications of both iDMS and its pre-processing input data assembly modules (DMS Data Extraction Toolkit). Both software assemblies enable users to rapidly deploy a validated machine learning alternative to manual DMS optimization. The applications are user-friendly, operate without need for any technical operating environment, make training dataset assembly quick and simple, and return measured, normalized, and predicted ionograms at every user-interrogated SV, evaluation of separability at each SV and CoV combination, and prediction of optimal resolution parameters to accelerate users’ MRM-LC-ESI-DMS-MS/MS deployment. Availability and implementation: Desktop iDMS and DMS Data Extraction Toolkit are native desktop applications for macOS (Apple Silicon), freely available for download at https://www.neurolipidomics.com/platforms.html under the GNU v3.0 license. The source code is available from GitHub and Zenodo at https://github.com/Neurolipidomics/iDMS , https://zenodo.org/records/22214408 , https://github.com/Neurolipidomics/DMSDataExtractionToolkit , and https://ze-nodo.org/records/22777403 . Benchmarking metrics are available at https://www.biorxiv.org/content/10.64898/2026.08.26.747394v1 . Contact: ldomic@uottawa.ca Supplementary Information: Supplementary material is available at Bioinformatics online.
- Open Access
Intelligent differential ion mobility spectrometry (iDMS): A deep neural network that predicts optimal space-resolved ion mobility parameters for isomeric monoglycosphingolipids
Simultaneous quantification of monoglycosphingolipid stereoisomers is required to monitor changes in defective enzymatic pathways linked to diseases such as Gaucher Disease, Parkinson's Disease, and Krabbe Disease. Resolution of beta-glucosyl and beta-galactosyl epimers cannot be achieved by standard liquid chromatography, electrospray ionization, tandem mass spectrometry (LC-ESI-MS/MS). Separation becomes possible when field asymmetric ion mobility spectrometry (FAIMS), also known as differential mobility mass spectrometry (DMS), is added as an orthogonal separation technique to LC. FAIMS/DMS separates epimeric ion clusters in a high versus low electric field (separation voltage, SV) then redirects the target epimeric ions to the mass spectrometer through the application of a direct current (compensation voltage, CoV). Resolving SVs and CoVs must be manually determined for each lipid. Manual derivation is a labour-intensive process that requires pure synthetic standards, limiting the number of stereoisomers a user can include in an assay. To address this problem, we introduce here intelligent DMS (iDMS). iDMS is an in silico supervised neural network model that learns the ion mobility relationships between SV and CoV and the monoglycosphingolipid structural features of sugar headgroup, N-acyl chain length, and N-acyl degree of unsaturation. iDMS predicts the SV and CoV combinations capable of resolving any stereoisomer pair from a training dataset of composed of measured signal intensities across a range of SVs and CoVs of 12 lipids. This machine learning alternative to manual DMS optimization promises to accelerate the deployment of multiple-reaction-monitoring mode (MRM) RPLC-ESI-DMS-MS/MS assays for the routine and rapid quantification of biologically relevant monoglycosphingolipid stereoisomers.
Open AccessIntelligent differential ion mobility spectrometry (iDMS): A deep neural network that predicts optimal space-resolved ion mobility parameters for isomeric monoglycosphingolipids
Simultaneous quantification of monoglycosphingolipid stereoisomers is required to monitor changes in defective enzymatic pathways linked to diseases such as Gaucher Disease, Parkinson's Disease, and Krabbe Disease. Resolution of beta-glucosyl and beta-galactosyl epimers cannot be achieved by standard liquid chromatography, electrospray ionization, tandem mass spectrometry (LC-ESI-MS/MS). Separation becomes possible when field asymmetric ion mobility spectrometry (FAIMS), also known as differential mobility mass spectrometry (DMS), is added as an orthogonal separation technique to LC. FAIMS/DMS separates epimeric ion clusters in a high versus low electric field (separation voltage, SV) then redirects the target epimeric ions to the mass spectrometer through the application of a direct current (compensation voltage, CoV). Resolving SVs and CoVs must be manually determined for each lipid. Manual derivation is a labour-intensive process that requires pure synthetic standards, limiting the number of stereoisomers a user can include in an assay. To address this problem, we introduce here intelligent DMS (iDMS). iDMS is an in silico supervised neural network model that learns the ion mobility relationships between SV and CoV and the monoglycosphingolipid structural features of sugar headgroup, N-acyl chain length, and N-acyl degree of unsaturation. iDMS predicts the SV and CoV combinations capable of resolving any stereoisomer pair from a training dataset of composed of measured signal intensities across a range of SVs and CoVs of 12 lipids. This machine learning alternative to manual DMS optimization promises to accelerate the deployment of multiple-reaction-monitoring mode (MRM) RPLC-ESI-DMS-MS/MS assays for the routine and rapid quantification of biologically relevant monoglycosphingolipid stereoisomers.
- Open Access
- 3 October 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-15
Concordant inter-laboratory derived concentrations of ceramides in human plasma reference materials via authentic standards
In this community effort, we compare measurements between 34 laboratories from 19 countries, utilizing mixtures of labelled authentic synthetic standards, to quantify by mass spectrometry four clinically used ceramide species in the NIST (National Institute of Standards and Technology) human blood plasma Standard Reference Material (SRM) 1950, as well as a set of candidate plasma reference materials (RM 8231). Participants either utilized a provided validated method and/or their method of choice. Mean concentration values, and intra- and inter-laboratory coefficients of variation (CV) were calculated using single-point and multi-point calibrations, respectively. These results are the most precise (intra-laboratory CVs ≤ 4.2%) and concordant (inter-laboratory CVs < 14%) community-derived absolute concentration values reported to date for four clinically used ceramides in the commonly analyzed SRM 1950. We demonstrate that calibration using authentic labelled standards dramatically reduces data variability. Furthermore, we show how the use of shared RM can correct systematic quantitative biases and help in harmonizing lipidomics. Collectively, the results from the present study provide a significant knowledge base for translation of lipidomic technologies to future clinical applications that might require the determination of reference intervals (RIs) in various human populations or might need to estimate reference change values (RCV), when analytical variability is a key factor for recall during multiple testing of individuals.
- 3 October 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-15
Open AccessConcordant inter-laboratory derived concentrations of ceramides in human plasma reference materials via authentic standards
In this community effort, we compare measurements between 34 laboratories from 19 countries, utilizing mixtures of labelled authentic synthetic standards, to quantify by mass spectrometry four clinically used ceramide species in the NIST (National Institute of Standards and Technology) human blood plasma Standard Reference Material (SRM) 1950, as well as a set of candidate plasma reference materials (RM 8231). Participants either utilized a provided validated method and/or their method of choice. Mean concentration values, and intra- and inter-laboratory coefficients of variation (CV) were calculated using single-point and multi-point calibrations, respectively. These results are the most precise (intra-laboratory CVs ≤ 4.2%) and concordant (inter-laboratory CVs < 14%) community-derived absolute concentration values reported to date for four clinically used ceramides in the commonly analyzed SRM 1950. We demonstrate that calibration using authentic labelled standards dramatically reduces data variability. Furthermore, we show how the use of shared RM can correct systematic quantitative biases and help in harmonizing lipidomics. Collectively, the results from the present study provide a significant knowledge base for translation of lipidomic technologies to future clinical applications that might require the determination of reference intervals (RIs) in various human populations or might need to estimate reference change values (RCV), when analytical variability is a key factor for recall during multiple testing of individuals.
- Open Access
- 1 May 2023
- Published by Oxford University Press (OUP) in Bioinformatics
- Vol. 39 (5)
Signed Distance Correlation (SiDCo): an online implementation of distance correlation and partial distance correlation for data-driven network analysis
Motivation: There is a need for easily accessible implementations that measure the strength of both linear and non-linear relationships between metabolites in biological systems as an approach for data-driven network development. While multiple tools implement linear Pearson and Spearman methods, there are no such tools that assess distance correlation.Results: We present here SIgned Distance COrrelation (SiDCo). SiDCo is a GUI platform for calculation of distance correlation in omics data, measuring linear and non-linear dependencies between variables, as well as correlation between vectors of different lengths, e.g. different sample sizes. By combining the sign of the overall trend from Pearson’s correlation with distance correlation values, we further provide a novel “signed distance correlation” of particular use in metabolomic and lipidomic analyses. Distance correlations can be selected as one-to-one or one-to-all correlations, showing relationships between each feature and all other features one at a time or in combination. Additionally, we implement “partial distance correlation,” calculated using the Gaussian Graphical model approach adapted to distance covariance. Our platform provides an easy-to-use software implementation that can be applied to the investigation of any dataset.Availability and implementation: The SiDCo software application is freely available at https://complimet.ca/sidco. Supplementary help pages are provided at https://complimet.ca/sidco. Supplementary Material shows an example of an application of SiDCo in metabolomics.
- 1 May 2023
- Published by Oxford University Press (OUP) in Bioinformatics
- Vol. 39 (5)
Open AccessSigned Distance Correlation (SiDCo): an online implementation of distance correlation and partial distance correlation for data-driven network analysis
Motivation: There is a need for easily accessible implementations that measure the strength of both linear and non-linear relationships between metabolites in biological systems as an approach for data-driven network development. While multiple tools implement linear Pearson and Spearman methods, there are no such tools that assess distance correlation.Results: We present here SIgned Distance COrrelation (SiDCo). SiDCo is a GUI platform for calculation of distance correlation in omics data, measuring linear and non-linear dependencies between variables, as well as correlation between vectors of different lengths, e.g. different sample sizes. By combining the sign of the overall trend from Pearson’s correlation with distance correlation values, we further provide a novel “signed distance correlation” of particular use in metabolomic and lipidomic analyses. Distance correlations can be selected as one-to-one or one-to-all correlations, showing relationships between each feature and all other features one at a time or in combination. Additionally, we implement “partial distance correlation,” calculated using the Gaussian Graphical model approach adapted to distance covariance. Our platform provides an easy-to-use software implementation that can be applied to the investigation of any dataset.Availability and implementation: The SiDCo software application is freely available at https://complimet.ca/sidco. Supplementary help pages are provided at https://complimet.ca/sidco. Supplementary Material shows an example of an application of SiDCo in metabolomics.
- Open Access
- 24 December 2021
- Published by Oxford University Press (OUP) in Bioinformatics
- Vol. 38 (6) , 1593-1599
BATL: Bayesian annotations for targeted lipidomics
Bioinformatic tools capable of annotating, rapidly and reproducibly, large, targeted lipidomic datasets are limited. Specifically, few programs enable high-throughput peak assessment of liquid chromatography–electrospray ionization tandem mass spectrometry data acquired in either selected or multiple reaction monitoring modes. We present here Bayesian Annotations for Targeted Lipidomics, a Gaussian naïve Bayes classifier for targeted lipidomics that annotates peak identities according to eight features related to retention time, intensity, and peak shape. Lipid identification is achieved by modeling distributions of these eight input features across biological conditions and maximizing the joint posterior probabilities of all peak identities at a given transition. When applied to sphingolipid and glycerophosphocholine selected reaction monitoring datasets, we demonstrate over 95% of all peaks are rapidly and correctly identified. BATL software is freely accessible online at https://complimet.ca/batl/ and is compatible with Safari, Firefox, Chrome and Edge. Supplementary data are available at Bioinformatics online.
- 24 December 2021
- Published by Oxford University Press (OUP) in Bioinformatics
- Vol. 38 (6) , 1593-1599
Open AccessBATL: Bayesian annotations for targeted lipidomics
Bioinformatic tools capable of annotating, rapidly and reproducibly, large, targeted lipidomic datasets are limited. Specifically, few programs enable high-throughput peak assessment of liquid chromatography–electrospray ionization tandem mass spectrometry data acquired in either selected or multiple reaction monitoring modes. We present here Bayesian Annotations for Targeted Lipidomics, a Gaussian naïve Bayes classifier for targeted lipidomics that annotates peak identities according to eight features related to retention time, intensity, and peak shape. Lipid identification is achieved by modeling distributions of these eight input features across biological conditions and maximizing the joint posterior probabilities of all peak identities at a given transition. When applied to sphingolipid and glycerophosphocholine selected reaction monitoring datasets, we demonstrate over 95% of all peaks are rapidly and correctly identified. BATL software is freely accessible online at https://complimet.ca/batl/ and is compatible with Safari, Firefox, Chrome and Edge. Supplementary data are available at Bioinformatics online.
- Open Access
- 1 January 2019
- Published by Elsevier in Journal of Lipid Research
- Vol. 60 (1) , 200-211
DMS as an orthogonal separation to LC/ESI/MS/MS for quantifying isomeric cerebrosides in plasma and cerebrospinal fluid
- 1 January 2019
- Published by Elsevier in Journal of Lipid Research
- Vol. 60 (1) , 200-211
Open AccessDMS as an orthogonal separation to LC/ESI/MS/MS for quantifying isomeric cerebrosides in plasma and cerebrospinal fluid
- Open Access
- 1 July 2018
- Published by Elsevier in Journal of Biological Chemistry
- Vol. 293 (29) , 11600-11611
Choline transport links macrophage phospholipid metabolism and inflammation
- 1 July 2018
- Published by Elsevier in Journal of Biological Chemistry
- Vol. 293 (29) , 11600-11611
Open AccessCholine transport links macrophage phospholipid metabolism and inflammation