Aline Banquart
Aline Banquart has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Samuel Callé
Université de Tours
3 shared publications Arnaud Capri
Carestream Dental, Croissy-Beaubourg, France
2 shared publications- Franck Levassort
University of Tours
2 shared publications Frédéric Ossant
UMR 1253, IBrain, Universit de Tours, Inserm, Tours, France
2 shared publicationsLionel Fritsch
Irlynx SA, Meylan, France
2 shared publicationsStéphanie Chevalliot
Carestream Dental, Croissy-Beaubourg, France
2 shared publications
Latest Publications
- 7 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Etude d'un dispositif ultrasonore intra-oral pour le dépistage de la maladie parodontale
Les maladies parodontales sont des pathologies très répandues qui affectent le parodonte, tissu soutenant les dents. Elles débutent par la gingivite, progressent vers la parodontite et peuvent altérer l’état général du patient. Actuellement, le diagnostic de la maladie n’est pas efficace, long, imprécis et peut être douloureux. Le développement d’un nouvel outil diagnostic est aujourd’hui largement attendu. Dans ce contexte, plusieurs auteurs ont montré que l’échographie haute-résolution peut fournir des informations pertinentes sur le parodonte. Le but de ce travail a été d’élaborer un prototype d’échographe haute-fréquence pour le diagnostic des maladies parodontales. Une nouvelle technologie de fabrication de transducteurs ultrasonores haute-fréquence à base de P(VDF-TrFE) a été évaluée. Elle consiste au dépôt par jet d’encre du matériau piézoélectrique sur un substrat de silicium et a permis la réalisation d’un réseau annulaire HF. Plus globalement, un premier prototype d’échographe a été développé, comprenant une sonde intra-orale avec un système de balayage mécanique du faisceau acoustique et une électronique dédiée. Les performances de ce prototype, notamment du point de vue de la qualité d’image, sont compatibles avec une exploration du parodonte. Des images du parodonte porcin ex-vivo sur tissus sains et pathologiques ont été réalisées.
- 7 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Etude d'un dispositif ultrasonore intra-oral pour le dépistage de la maladie parodontale
Les maladies parodontales sont des pathologies très répandues qui affectent le parodonte, tissu soutenant les dents. Elles débutent par la gingivite, progressent vers la parodontite et peuvent altérer l’état général du patient. Actuellement, le diagnostic de la maladie n’est pas efficace, long, imprécis et peut être douloureux. Le développement d’un nouvel outil diagnostic est aujourd’hui largement attendu. Dans ce contexte, plusieurs auteurs ont montré que l’échographie haute-résolution peut fournir des informations pertinentes sur le parodonte. Le but de ce travail a été d’élaborer un prototype d’échographe haute-fréquence pour le diagnostic des maladies parodontales. Une nouvelle technologie de fabrication de transducteurs ultrasonores haute-fréquence à base de P(VDF-TrFE) a été évaluée. Elle consiste au dépôt par jet d’encre du matériau piézoélectrique sur un substrat de silicium et a permis la réalisation d’un réseau annulaire HF. Plus globalement, un premier prototype d’échographe a été développé, comprenant une sonde intra-orale avec un système de balayage mécanique du faisceau acoustique et une électronique dédiée. Les performances de ce prototype, notamment du point de vue de la qualité d’image, sont compatibles avec une exploration du parodonte. Des images du parodonte porcin ex-vivo sur tissus sains et pathologiques ont été réalisées.
- Open Access
High Acoustic Impedance and Attenuation Backing for High-Frequency Focused P(VDF-TrFE)-Based Transducers
Backing materials with tailored acoustic properties are beneficial for miniaturized ultrasonic transducer design. Whereas piezoelectric P(VDF-TrFE) films are common elements in high-frequency (>20 MHz) transducer design, their low coupling coefficient limits their sensitivity. Defining a suitable sensitivity–bandwidth trade-off for miniaturized high-frequency applications requires backings with impedances of >25 MRayl and strongly attenuating to account for miniaturized requirements. The motivation of this work is related to several medical applications such as small animal, skin or eye imaging. Simulations showed that increasing the acoustic impedance of the backing from 4.5 to 25 MRayl increases transducer sensitivity by 5 dB but decreases the bandwidth, which nevertheless remains high enough for the targeted applications. In this paper, porous sintered bronze material with spherically shaped grains, size-adapted for 25–30 MHz frequency, was impregnated with tin or epoxy resin to create multiphasic metallic backings. Microstructural characterizations of these new multiphasic composites showed that impregnation was incomplete and that a third air phase was present. The selected composites, sintered bronze–tin–air and sintered bronze–epoxy–air, at 5–35 MHz characterization, produced attenuation coefficients of 1.2 and >4 dB/mm/MHz and impedances of 32.4 and 26.4 MRayl, respectively. High-impedance composites were adopted as backing (thickness = 2 mm) to fabricate focused single-element P(VDF-TrFE)-based transducers (focal distance = 14 mm). The center frequency was 27 MHz, while the bandwidth at −6 dB was 65% for the sintered-bronze–tin–air-based transducer. We evaluated imaging performance using a pulse-echo system on a tungsten wire (diameter = 25 μm) phantom. Images confirmed the viability of integrating these backings in miniaturized transducers for imaging applications.
Open AccessHigh Acoustic Impedance and Attenuation Backing for High-Frequency Focused P(VDF-TrFE)-Based Transducers
Backing materials with tailored acoustic properties are beneficial for miniaturized ultrasonic transducer design. Whereas piezoelectric P(VDF-TrFE) films are common elements in high-frequency (>20 MHz) transducer design, their low coupling coefficient limits their sensitivity. Defining a suitable sensitivity–bandwidth trade-off for miniaturized high-frequency applications requires backings with impedances of >25 MRayl and strongly attenuating to account for miniaturized requirements. The motivation of this work is related to several medical applications such as small animal, skin or eye imaging. Simulations showed that increasing the acoustic impedance of the backing from 4.5 to 25 MRayl increases transducer sensitivity by 5 dB but decreases the bandwidth, which nevertheless remains high enough for the targeted applications. In this paper, porous sintered bronze material with spherically shaped grains, size-adapted for 25–30 MHz frequency, was impregnated with tin or epoxy resin to create multiphasic metallic backings. Microstructural characterizations of these new multiphasic composites showed that impregnation was incomplete and that a third air phase was present. The selected composites, sintered bronze–tin–air and sintered bronze–epoxy–air, at 5–35 MHz characterization, produced attenuation coefficients of 1.2 and >4 dB/mm/MHz and impedances of 32.4 and 26.4 MRayl, respectively. High-impedance composites were adopted as backing (thickness = 2 mm) to fabricate focused single-element P(VDF-TrFE)-based transducers (focal distance = 14 mm). The center frequency was 27 MHz, while the bandwidth at −6 dB was 65% for the sintered-bronze–tin–air-based transducer. We evaluated imaging performance using a pulse-echo system on a tungsten wire (diameter = 25 μm) phantom. Images confirmed the viability of integrating these backings in miniaturized transducers for imaging applications.
- 6 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (4) , 313-323
Inkjet-Printed P(VDF-TrFE) Film for High-Frequency Annular Array
An innovative processing to deposit P(VDF-TrFE) film on silicon wafers by an inkjet printing method was used to fabricate high-frequency annular array prototype. This prototype has a total aperture of 7.3 mm and 8 active elements. A polymer-based lens with low acoustic attenuation was added to the flat deposition on the wafer, setting the geometric focus to 13.8 mm. With a thickness of around 11 μm, the electromechanical performance of P(VDF-TrFE) films was evaluated with an effective thickness coupling factor of 22%. Electronics allowing all elements to simultaneously emit as a single element transducer was developed. In reception, a dynamic focusing, based on eight independent amplifying channels, was preferred. The center frequency of the prototype was 21.3 MHz, the insertion loss was 48.5 dB and the –6 dB fractional bandwidth was 143%. The trade-off sensitivity/bandwidth has rather favored the large bandwidth. Dynamic focusing on reception was applied and allowed to improvements in the lateral-full width at half maximum as shown on images obtained with a wire phantom at several depths. The next step, for a fully operational multi-element transducer, will be to achieve a significant increase of the acoustic attenuation in the silicon wafer.
- 6 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (4) , 313-323
Inkjet-Printed P(VDF-TrFE) Film for High-Frequency Annular Array
An innovative processing to deposit P(VDF-TrFE) film on silicon wafers by an inkjet printing method was used to fabricate high-frequency annular array prototype. This prototype has a total aperture of 7.3 mm and 8 active elements. A polymer-based lens with low acoustic attenuation was added to the flat deposition on the wafer, setting the geometric focus to 13.8 mm. With a thickness of around 11 μm, the electromechanical performance of P(VDF-TrFE) films was evaluated with an effective thickness coupling factor of 22%. Electronics allowing all elements to simultaneously emit as a single element transducer was developed. In reception, a dynamic focusing, based on eight independent amplifying channels, was preferred. The center frequency of the prototype was 21.3 MHz, the insertion loss was 48.5 dB and the –6 dB fractional bandwidth was 143%. The trade-off sensitivity/bandwidth has rather favored the large bandwidth. Dynamic focusing on reception was applied and allowed to improvements in the lateral-full width at half maximum as shown on images obtained with a wire phantom at several depths. The next step, for a fully operational multi-element transducer, will be to achieve a significant increase of the acoustic attenuation in the silicon wafer.
- 20 May 2021
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 129 (19) , 195107
Piezoelectric P(VDF-TrFE) film inkjet printed on silicon for high-frequency ultrasound applications
We investigated the innovative processing of poly(vinylidene fluoride-trifluoroethylene) P(VDFx-TrFE1-x) (x = 83 mol. %) by inkjet printing to deliver uniform and thickness-controlled layers on silicon substrates. Here, we provide detailed processing steps and optimize film deposition conditions. The thickness coupling factor for a P(VDF-TrFE) film around 11 μm thick was 22%, demonstrating good electromechanical performance after poling. These multilayer structures were specifically for high-frequency, single-element ultrasonic transducer applications. The measurements of electro-acoustic responses were in water. The maximal frequency was centered at 33.2 MHz and had a fine axial resolution at 22 μm, corresponding to a fractional bandwidth at −6 dB of 100%. In the context of technological evolutions aimed at miniaturized devices and integrated electronics, these results allow for the consideration of complex structures such as multi-element transducers for high-frequency imaging applications.
- 20 May 2021
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 129 (19) , 195107
Piezoelectric P(VDF-TrFE) film inkjet printed on silicon for high-frequency ultrasound applications
We investigated the innovative processing of poly(vinylidene fluoride-trifluoroethylene) P(VDFx-TrFE1-x) (x = 83 mol. %) by inkjet printing to deliver uniform and thickness-controlled layers on silicon substrates. Here, we provide detailed processing steps and optimize film deposition conditions. The thickness coupling factor for a P(VDF-TrFE) film around 11 μm thick was 22%, demonstrating good electromechanical performance after poling. These multilayer structures were specifically for high-frequency, single-element ultrasonic transducer applications. The measurements of electro-acoustic responses were in water. The maximal frequency was centered at 33.2 MHz and had a fine axial resolution at 22 μm, corresponding to a fractional bandwidth at −6 dB of 100%. In the context of technological evolutions aimed at miniaturized devices and integrated electronics, these results allow for the consideration of complex structures such as multi-element transducers for high-frequency imaging applications.