Harun Uysal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Harun Uysal has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Suna Koc
Biruni Univ, Dept Anesthesiol & Reanimat, Istanbul, Turkey
2 shared publications- Ali Asram Sağıroğlu
Department of Pharmaceutical Technology, Faculty of Pharmacy, Istanbul University-Cerrahpasa
1 shared publication - Alper Yenigun
Department of Otorhinolaryngology, Faculty of Medicine, Bezmialem Vakif University, Fatih, Istanbul, Turkey
1 shared publication Hakan Senturk
Department of Gastroenterology and Hepatology, Faculty of Medicine, Bezmialem Vakif University, Istanbul, Turkey
1 shared publicationHayrettin Daskaya
Department of Anesthesiology and Reanimation, Faculty of Medicine, Bezmialem Vakif University, Istanbul, Turkey
1 shared publication- Hayrettin Daşkaya
BEZM-İ ÂLEM VAKIF ÜNİVERSİTESİ
1 shared publication
Latest Publications
- 5 September 2025
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 198, 112552
Intranasal diclofenac sodium, ibuprofen and paracetamol for pain relief after pediatric tonsillectomy
- 5 September 2025
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 198, 112552
Intranasal diclofenac sodium, ibuprofen and paracetamol for pain relief after pediatric tonsillectomy
- Open Access
- 16 December 2022
- Published by Wolters Kluwer Health in Medicine
- Vol. 101 (50) , e32269
Utility of the gastro-laryngeal tube during transesophageal echocardiography: A prospective randomized clinical trial
Background: To validate the utility and performance of the gastro-laryngeal tube (GLT) in terms of cardiologist and patient satisfaction levels, incidence of and attempts at successful transesophageal echocardiography (TEE) probe placement, perioperative and postoperative hemodynamics, and adverse events related to the TEE procedure. Methods: In this randomized prospective clinical study, forty-four patients undergoing TEE and aged 20 to 80 years old scheduled for TEE were randomly allocated to two study groups: Group SA (sedation and analgesia) and Group GLT. Cardiologist and patient satisfaction levels, TEE probe placement performance, hemodynamics, adverse events related to the TEE procedure, demographic characteristics, and TEE procedure data were recorded. Results: The cardiologist satisfaction level was significantly higher in Group GLT (P = .011). The TEE probe was successfully placed at the first attempt in all the patients in Group GLT and at the first attempt in 11 patients, at the second attempt in 8 patients, and at the third attempt in 3 patients in Group SA. The TEE probe placement success was significantly higher in Group GLT (P < .001), and TEE probe placement was significantly easier in Group GLT (P < .001). There were no significant differences in patient satisfaction, heart rate, mean arterial pressure, oxygen saturation, adverse events related to the TEE procedure between the groups. Conclusion: The present study revealed that GLT use elicited a higher cardiologist satisfaction level and resulted in more successful and easier TEE probe placement. We thus conclude that the use of the recently developed GLT may ensure airway management safety and a comfortable TEE experience.
- 16 December 2022
- Published by Wolters Kluwer Health in Medicine
- Vol. 101 (50) , e32269
Open AccessUtility of the gastro-laryngeal tube during transesophageal echocardiography: A prospective randomized clinical trial
Background: To validate the utility and performance of the gastro-laryngeal tube (GLT) in terms of cardiologist and patient satisfaction levels, incidence of and attempts at successful transesophageal echocardiography (TEE) probe placement, perioperative and postoperative hemodynamics, and adverse events related to the TEE procedure. Methods: In this randomized prospective clinical study, forty-four patients undergoing TEE and aged 20 to 80 years old scheduled for TEE were randomly allocated to two study groups: Group SA (sedation and analgesia) and Group GLT. Cardiologist and patient satisfaction levels, TEE probe placement performance, hemodynamics, adverse events related to the TEE procedure, demographic characteristics, and TEE procedure data were recorded. Results: The cardiologist satisfaction level was significantly higher in Group GLT (P = .011). The TEE probe was successfully placed at the first attempt in all the patients in Group GLT and at the first attempt in 11 patients, at the second attempt in 8 patients, and at the third attempt in 3 patients in Group SA. The TEE probe placement success was significantly higher in Group GLT (P < .001), and TEE probe placement was significantly easier in Group GLT (P < .001). There were no significant differences in patient satisfaction, heart rate, mean arterial pressure, oxygen saturation, adverse events related to the TEE procedure between the groups. Conclusion: The present study revealed that GLT use elicited a higher cardiologist satisfaction level and resulted in more successful and easier TEE probe placement. We thus conclude that the use of the recently developed GLT may ensure airway management safety and a comfortable TEE experience.
- 1 January 2022
- Published by Kare Publishing in Eurasian Journal of Medical Investigation
- Vol. 6 (2) , 157-164
Comparison of Anesthesia Managements with General Anesthesia and Sedation in Multi Parametric Magnetic Resonance Imaging (mpMRI) Transrectal Ultrasound Guided (TRUS) Fusion Targeted Prostate Biopsy: A Prospective, Randomized Study
- 1 January 2022
- Published by Kare Publishing in Eurasian Journal of Medical Investigation
- Vol. 6 (2) , 157-164
Comparison of Anesthesia Managements with General Anesthesia and Sedation in Multi Parametric Magnetic Resonance Imaging (mpMRI) Transrectal Ultrasound Guided (TRUS) Fusion Targeted Prostate Biopsy: A Prospective, Randomized Study
- 1 January 2022
- Published by Clinical Laboratory Publications in Clinical Laboratory
- Vol. 68 (02/2022) , 401-409
Literature Review of Hemadsorption Therapy in Severe COVID-19 Cases: a Narrative Review
Background: A novel therapy for reducing the cytokines in the circulatory system used for severe COVID-19 cases was hemoperfusion or hemadsorption method. Although the hemoperfusion methods have been shown to be beneficial in the cytokine storm during influenza infection, it is not known to what extent it is successful for COVID-19 patients. Therefore, the purpose of this study is to review the studies on severe COVID-19 treated with the hemoperfusion methods. Methods: A literature search was conducted using the databases PubMed, Science Direct, and Springer databases. Since the included articles consisted of case reports, case series, and one controlled trial, only the mean of the analyzed data could be calculated. Results: Sixteen studies were included in the narrative review, including 86 patients with severe COVID-19. All the patients had hemoperfusion therapy with following cartridges: CytoSorb (R), oXiris (R), Biosky filter, SeaStar (R) CLR filter, HA280, HA330 Jafron (c), and resin directed hemadsorption cartridges. Mortality rate, the mean of intubation time, duration in intensive care unit and hospital were 29%, 14.93 days, 17.21 days, and 31.7 days, respectively. The mean values of C-reactive protein and interleukin-6 decreased after hemoperfusion sessions (131.7 to 66.0, 527.5 to 334.7, respectively). Conclusions: In this narrative review, it is demonstrated that hemadsorption therapy is an alternative salvage treatment method in critically ill COVID-19 patients, but the data must be supported by strong evidence.
- 1 January 2022
- Published by Clinical Laboratory Publications in Clinical Laboratory
- Vol. 68 (02/2022) , 401-409
Literature Review of Hemadsorption Therapy in Severe COVID-19 Cases: a Narrative Review
Background: A novel therapy for reducing the cytokines in the circulatory system used for severe COVID-19 cases was hemoperfusion or hemadsorption method. Although the hemoperfusion methods have been shown to be beneficial in the cytokine storm during influenza infection, it is not known to what extent it is successful for COVID-19 patients. Therefore, the purpose of this study is to review the studies on severe COVID-19 treated with the hemoperfusion methods. Methods: A literature search was conducted using the databases PubMed, Science Direct, and Springer databases. Since the included articles consisted of case reports, case series, and one controlled trial, only the mean of the analyzed data could be calculated. Results: Sixteen studies were included in the narrative review, including 86 patients with severe COVID-19. All the patients had hemoperfusion therapy with following cartridges: CytoSorb (R), oXiris (R), Biosky filter, SeaStar (R) CLR filter, HA280, HA330 Jafron (c), and resin directed hemadsorption cartridges. Mortality rate, the mean of intubation time, duration in intensive care unit and hospital were 29%, 14.93 days, 17.21 days, and 31.7 days, respectively. The mean values of C-reactive protein and interleukin-6 decreased after hemoperfusion sessions (131.7 to 66.0, 527.5 to 334.7, respectively). Conclusions: In this narrative review, it is demonstrated that hemadsorption therapy is an alternative salvage treatment method in critically ill COVID-19 patients, but the data must be supported by strong evidence.
- 1 October 2021
- Published by Edizioni Minerva Medica in Minerva Anestesiologica
- Vol. 87 (9) , 987-996
Comparison of LMA® Gastro™ airway and gastrolaryngeal tube in endoscopic retrograde cholangiopancreatography: a prospective randomized observational trial
Article: Comparison of LMA® gastro airway and gastro-laryngeal tube in endoscopic retrograde cholangiopancreatography: a prospective randomized observational trial - Minerva Anestesiologica 2021 May 13 - Minerva Medica - Journals
- 1 October 2021
- Published by Edizioni Minerva Medica in Minerva Anestesiologica
- Vol. 87 (9) , 987-996
Comparison of LMA® Gastro™ airway and gastrolaryngeal tube in endoscopic retrograde cholangiopancreatography: a prospective randomized observational trial
Article: Comparison of LMA® gastro airway and gastro-laryngeal tube in endoscopic retrograde cholangiopancreatography: a prospective randomized observational trial - Minerva Anestesiologica 2021 May 13 - Minerva Medica - Journals