Jan P. C. van Santvoort
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jan P. C. van Santvoort has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Anna L. Petoukhova
Department of Medical Physics, Haaglanden Medical Center, Leidschendam, the Netherlands
4 shared publications - Ruud Wiggenraad
Radiotherapy Centre West, Lijnbaan 32, 2501 CK, The Hague, The Netherlands,
3 shared publications B J M Heijmen
University Hospital Rotterdam/Daniel den Hoed Cancer Center, Groene Hilledijk 301, 3075 EA Rotterdam, The Netherlands
2 shared publicationsB.J.M. Heijmen
2 shared publicationsD. Binnekamp
2 shared publicationsHenk Struikmans
Radiotherapy Centre West
2 shared publications
Latest Publications
- 1 June 2021
- Published by Taylor & Francis in British Journal Of Neurosurgery
- Vol. 35 (5) , 591-596
Atypical meningioma: patterns of postradiotherapy recurrences
There is no consensus on a target definition and optimal dose in radiotherapy for atypical meningioma (AM). Insight into the postradiotherapy recurrence pattern is needed for optimal target definit...
- 1 June 2021
- Published by Taylor & Francis in British Journal Of Neurosurgery
- Vol. 35 (5) , 591-596
Atypical meningioma: patterns of postradiotherapy recurrences
There is no consensus on a target definition and optimal dose in radiotherapy for atypical meningioma (AM). Insight into the postradiotherapy recurrence pattern is needed for optimal target definit...
- 1 January 2020
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 142, 147-153
Lower doses to hippocampi and other brain structures for skull-base meningiomas with intensity modulated proton therapy compared to photon therapy
- 1 January 2020
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 142, 147-153
Lower doses to hippocampi and other brain structures for skull-base meningiomas with intensity modulated proton therapy compared to photon therapy
- Open Access
- 1 July 2019
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 11, 30-33
The influence of a six degrees of freedom couch and an individual head support in patient positioning in radiotherapy of head and neck cancer
- 1 July 2019
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 11, 30-33
Open AccessThe influence of a six degrees of freedom couch and an individual head support in patient positioning in radiotherapy of head and neck cancer
- Open Access
- 1 April 2018
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 127, S1290-S1291
EP-2339: Evaluation of a new mask system for stereotactic radiotherapy in brain lesions
- 1 April 2018
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 127, S1290-S1291
Open AccessEP-2339: Evaluation of a new mask system for stereotactic radiotherapy in brain lesions
- 5 July 2014
- Published by Springer Nature in Journal of Neuro-Oncology
- Vol. 119 (2) , 437-443
Pseudo-progression after stereotactic radiotherapy of brain metastases: lesion analysis using MRI cine-loops
Stereotactic radiotherapy (SRT) of brain metastasis can lead to lesion growth caused by radiation toxicity. The pathophysiology of this so-called pseudo-progression is poorly understood. The purpose of this study was to evaluate the use of MRI cine-loops for describing the consecutive events in this radiation induced lesion growth. Ten patients were selected from our department’s database that had received SRT of brain metastases and had lesion growth caused by pseudo-progression as well as at least five follow-up MRI scans. Pre- and post SRT MRI scans were co-registered and cine-loops were made using post-gadolinium 3D T1 axial slices. The ten cine loops were discussed in a joint meeting of the authors. The use of cine-loops was superior to evaluation of separate MRI scans for interpretation of events after SRT. There was a typical lesion evolution pattern in all patients with varying time course. Initially regression of the metastases was observed, followed by an enlarging area of new contrast enhancement in the surrounding brain tissue. Analysis of consecutive MRI’s using cine-loops may improve understanding of pseudo-progression. It probably represents a radiation effect in brain tissue surrounding the irradiated metastasis and not enlargement of the metastasis itself.
- 5 July 2014
- Published by Springer Nature in Journal of Neuro-Oncology
- Vol. 119 (2) , 437-443
Pseudo-progression after stereotactic radiotherapy of brain metastases: lesion analysis using MRI cine-loops
Stereotactic radiotherapy (SRT) of brain metastasis can lead to lesion growth caused by radiation toxicity. The pathophysiology of this so-called pseudo-progression is poorly understood. The purpose of this study was to evaluate the use of MRI cine-loops for describing the consecutive events in this radiation induced lesion growth. Ten patients were selected from our department’s database that had received SRT of brain metastases and had lesion growth caused by pseudo-progression as well as at least five follow-up MRI scans. Pre- and post SRT MRI scans were co-registered and cine-loops were made using post-gadolinium 3D T1 axial slices. The ten cine loops were discussed in a joint meeting of the authors. The use of cine-loops was superior to evaluation of separate MRI scans for interpretation of events after SRT. There was a typical lesion evolution pattern in all patients with varying time course. Initially regression of the metastases was observed, followed by an enlarging area of new contrast enhancement in the surrounding brain tissue. Analysis of consecutive MRI’s using cine-loops may improve understanding of pseudo-progression. It probably represents a radiation effect in brain tissue surrounding the irradiated metastasis and not enlargement of the metastasis itself.
- 29 July 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (16) , 5411-5428
The ArcCHECK diode array for dosimetric verification of HybridArc
The aim of this work is to evaluate dosimetric accuracy of a new treatment modality, HybridArc, in iPlan RT Dose 4.5 (BrainLAB, Feldkirchen, Germany) using a four-dimensional diode array (ArcCHECK, Sun Nuclear Corporation, Melbourne, USA). HybridArc is able to enhance dynamic conformal arcs with inversely planned elements. HybridArc plans for various sites (intracranial and extracranial) were constructed and after that these plans were recalculated for the ArcCHECK diode array with Monte Carlo (MC) and Pencil Beam (PB) dose algorithms in iPlan RT Dose. All measurements of these HybridArc plans were performed with 6 MV photon beams of a Novalis accelerator (BrainLAB, Feldkirchen, Germany) using the ArcCHECK device without and with an insert containing an ionization chamber. Comparison of the absolute dose distributions measured and calculated in iPlan RT Dose with the MC algorithm at the cylinder of the ArcCHECK diode array for HybridArc plans gives good agreement, even for the 2% dose difference and 2 mm distance-to-agreement criteria. The PB calculations significantly differ from the ArcCHECK measurements so that the MC algorithm is found to be superior to the PB algorithm in the calculation of the HybridArc plans. One of the drawbacks of the PB calculations in iPlan RT Dose is the too large arc step size of 10°. Use of a finer angular resolution may improve the PB results significantly.
- 29 July 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (16) , 5411-5428
The ArcCHECK diode array for dosimetric verification of HybridArc
The aim of this work is to evaluate dosimetric accuracy of a new treatment modality, HybridArc, in iPlan RT Dose 4.5 (BrainLAB, Feldkirchen, Germany) using a four-dimensional diode array (ArcCHECK, Sun Nuclear Corporation, Melbourne, USA). HybridArc is able to enhance dynamic conformal arcs with inversely planned elements. HybridArc plans for various sites (intracranial and extracranial) were constructed and after that these plans were recalculated for the ArcCHECK diode array with Monte Carlo (MC) and Pencil Beam (PB) dose algorithms in iPlan RT Dose. All measurements of these HybridArc plans were performed with 6 MV photon beams of a Novalis accelerator (BrainLAB, Feldkirchen, Germany) using the ArcCHECK device without and with an insert containing an ionization chamber. Comparison of the absolute dose distributions measured and calculated in iPlan RT Dose with the MC algorithm at the cylinder of the ArcCHECK diode array for HybridArc plans gives good agreement, even for the 2% dose difference and 2 mm distance-to-agreement criteria. The PB calculations significantly differ from the ArcCHECK measurements so that the MC algorithm is found to be superior to the PB algorithm in the calculation of the HybridArc plans. One of the drawbacks of the PB calculations in iPlan RT Dose is the too large arc step size of 10°. Use of a finer angular resolution may improve the PB results significantly.
- 29 July 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (16) , 4601-4614
Verification measurements and clinical evaluation of the iPlan RT Monte Carlo dose algorithm for 6 MV photon energy
This study presents data for verification of the iPlan RT Monte Carlo (MC) dose algorithm (BrainLAB, Feldkirchen, Germany). MC calculations were compared with pencil beam (PB) calculations and verification measurements in phantoms with lung-equivalent material, air cavities or bone-equivalent material to mimic head and neck and thorax and in an Alderson anthropomorphic phantom. Dosimetric accuracy of MC for the micro-multileaf collimator (MLC) simulation was tested in a homogeneous phantom. All measurements were performed using an ionization chamber and Kodak EDR2 films with Novalis 6 MV photon beams. Dose distributions measured with film and calculated with MC in the homogeneous phantom are in excellent agreement for oval, C and squiggle-shaped fields and for a clinical IMRT plan. For a field with completely closed MLC, MC is much closer to the experimental result than the PB calculations. For fields larger than the dimensions of the inhomogeneities the MC calculations show excellent agreement (within 3%/1 mm) with the experimental data. MC calculations in the anthropomorphic phantom show good agreement with measurements for conformal beam plans and reasonable agreement for dynamic conformal arc and IMRT plans. For 6 head and neck and 15 lung patients a comparison of the MC plan with the PB plan was performed. Our results demonstrate that MC is able to accurately predict the dose in the presence of inhomogeneities typical for head and neck and thorax regions with reasonable calculation times (5-20 min). Lateral electron transport was well reproduced in MC calculations. We are planning to implement MC calculations for head and neck and lung cancer patients.
- 29 July 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (16) , 4601-4614
Verification measurements and clinical evaluation of the iPlan RT Monte Carlo dose algorithm for 6 MV photon energy
This study presents data for verification of the iPlan RT Monte Carlo (MC) dose algorithm (BrainLAB, Feldkirchen, Germany). MC calculations were compared with pencil beam (PB) calculations and verification measurements in phantoms with lung-equivalent material, air cavities or bone-equivalent material to mimic head and neck and thorax and in an Alderson anthropomorphic phantom. Dosimetric accuracy of MC for the micro-multileaf collimator (MLC) simulation was tested in a homogeneous phantom. All measurements were performed using an ionization chamber and Kodak EDR2 films with Novalis 6 MV photon beams. Dose distributions measured with film and calculated with MC in the homogeneous phantom are in excellent agreement for oval, C and squiggle-shaped fields and for a clinical IMRT plan. For a field with completely closed MLC, MC is much closer to the experimental result than the PB calculations. For fields larger than the dimensions of the inhomogeneities the MC calculations show excellent agreement (within 3%/1 mm) with the experimental data. MC calculations in the anthropomorphic phantom show good agreement with measurements for conformal beam plans and reasonable agreement for dynamic conformal arc and IMRT plans. For 6 head and neck and 15 lung patients a comparison of the MC plan with the PB plan was performed. Our results demonstrate that MC is able to accurately predict the dose in the presence of inhomogeneities typical for head and neck and thorax regions with reasonable calculation times (5-20 min). Lateral electron transport was well reproduced in MC calculations. We are planning to implement MC calculations for head and neck and lung cancer patients.
- 1 July 2009
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 74 (4) , 1018-1026
Stereotactic Radiotherapy of Intracranial Tumors: A Comparison of Intensity-Modulated Radiotherapy and Dynamic Conformal Arc
- 1 July 2009
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 74 (4) , 1018-1026
Stereotactic Radiotherapy of Intracranial Tumors: A Comparison of Intensity-Modulated Radiotherapy and Dynamic Conformal Arc
- 1 September 2008
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 72 (1) , 261-267
Positioning Accuracy in Stereotactic Radiotherapy Using a Mask System With Added Vacuum Mouth Piece and Stereoscopic X-Ray Positioning
- 1 September 2008
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 72 (1) , 261-267
Positioning Accuracy in Stereotactic Radiotherapy Using a Mask System With Added Vacuum Mouth Piece and Stereoscopic X-Ray Positioning
- 1 October 2005
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 181 (10) , 673-682
ConPas: a 3-D Conformal Parotid Gland-Sparing Irradiation Technique for Bilateral Neck Treatment as an Alternative to IMRT
Background and Purpose: Intensity-modulated radiotherapy (IMRT) is used in most reported techniques for bilateral neck irradiation that aim at parotid gland sparing. A relatively simple conformal parotid-sparing technique (ConPas) was developed that uses no beam-intensity modulation. The purpose of this paper is to demonstrate, in patients with larynx or hypopharynx carcinoma, that ConPas enables adequate coverage of the primary tumor and the bilateral neck nodes, while keeping the mean parotid dose (MPD) < 26 Gy. Patients and Methods: Treatment plans using ConPas and the conventional technique (using one anteroposterior supraclavicular and two lateral beams) were computed for ten consecutive patients with T1–4 N0–1 larynx or hypopharynx carcinoma (not T1 glottic). A dose of 46 Gy was prescribed to the primary tumor and the bilateral neck nodes, planned either with the conventional technique or ConPas, followed by a boost up to 70 Gy with a simple two-field technique. The target coverage of both techniques was compared using the V95, the percentage of the planning target volume (PTV) of the primary tumor and nodal regions receiving at least 95% of the prescribed elective dose. The MPDs and the normal-tissue complication probabilities (NTCPs) of the parotid glands were compared using either technique including the boost up to 70 Gy. Dosimetric verification of the technique has been carried out, using ionization chamber measurements and film dosimetry. Results: The mean V95 was 85.2% and 91.2% (p = 0.08), the mean MPD 38.7 Gy and 25.4 Gy (p < 0.001), and the mean NTCP for the parotid glands 0.87 and 0.22 (p < 0.001) for the conventional technique and ConPas, respectively. The dosimetric verification shows a good agreement between dose calculation and measurement. Conclusion: ConPas enables adequate target coverage and clinically relevant parotid sparing in bilateral neck irradiation without beam-intensity modulation.
- 1 October 2005
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 181 (10) , 673-682
ConPas: a 3-D Conformal Parotid Gland-Sparing Irradiation Technique for Bilateral Neck Treatment as an Alternative to IMRT
Background and Purpose: Intensity-modulated radiotherapy (IMRT) is used in most reported techniques for bilateral neck irradiation that aim at parotid gland sparing. A relatively simple conformal parotid-sparing technique (ConPas) was developed that uses no beam-intensity modulation. The purpose of this paper is to demonstrate, in patients with larynx or hypopharynx carcinoma, that ConPas enables adequate coverage of the primary tumor and the bilateral neck nodes, while keeping the mean parotid dose (MPD) < 26 Gy. Patients and Methods: Treatment plans using ConPas and the conventional technique (using one anteroposterior supraclavicular and two lateral beams) were computed for ten consecutive patients with T1–4 N0–1 larynx or hypopharynx carcinoma (not T1 glottic). A dose of 46 Gy was prescribed to the primary tumor and the bilateral neck nodes, planned either with the conventional technique or ConPas, followed by a boost up to 70 Gy with a simple two-field technique. The target coverage of both techniques was compared using the V95, the percentage of the planning target volume (PTV) of the primary tumor and nodal regions receiving at least 95% of the prescribed elective dose. The MPDs and the normal-tissue complication probabilities (NTCPs) of the parotid glands were compared using either technique including the boost up to 70 Gy. Dosimetric verification of the technique has been carried out, using ionization chamber measurements and film dosimetry. Results: The mean V95 was 85.2% and 91.2% (p = 0.08), the mean MPD 38.7 Gy and 25.4 Gy (p < 0.001), and the mean NTCP for the parotid glands 0.87 and 0.22 (p < 0.001) for the conventional technique and ConPas, respectively. The dosimetric verification shows a good agreement between dose calculation and measurement. Conclusion: ConPas enables adequate target coverage and clinically relevant parotid sparing in bilateral neck irradiation without beam-intensity modulation.