Po-Yu Chu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Po-Yu Chu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chia-Hsun Hsieh
Department of Medical Oncology, Chang Gung Memorial Hospital and Chang Gung University, Taoyuan, Taiwan, ROC
3 shared publications - Min-Hsien Wu
Graduate Institute of Biomedical Engineering, Chang Gung University, Taoyuan City 33302, Taiwan
3 shared publications - Chia-Ming Yang
Department of Electronic Engineering, Institute of Electro-Optical Engineering, Chang-Gung University, Taoyuan City, Taiwan (R.O.C.)
2 shared publications - Jian-Cyun Yu
Graduate Institute of Biomedical Engineering, Chang Gung University, Taoyuan City 33302, Taiwan
2 shared publications - Ai-Yun Wu
Graduate Institute of Biomedical Engineering, Chang Gung University, Taoyuan City 33302, Taiwan
1 shared publication - Hsin-Yuan Hung
Division of Colon and Rectal Surgery, New Taipei Municipal TuCheng Hospital, New Taipei City 23652, Taiwan
1 shared publication
Latest Publications
- Open Access
- 16 December 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (12) , 540
Virtual Filter Membranes in a Microfluidic System for Sorting and Separating Size-Based Micro Polystyrene Beads by Illumination Intensity Design in Optically Induced Dielectrophoresis (ODEP)
In biomedical diagnosis, the efficient separation and purification of specific targets from clinical samples is the desired first step. Herein, the concept of virtual filter membranes based on optically-induced dielectrophoresis (ODEP) manipulation in a microfluidic channel is proposed as a light screening membrane for the separation of polystyrene (PS) microparticles with three different diameters of 15.8, 10.8 and 5.8 µm. The ODEP manipulation velocity of three types of PS microparticles reacted with the color brightness setting was investigated to determine the light intensity to induce an ODEP force higher than the drag force of fluid speed. The color brightness of the light bar in three areas of the light screening membrane was selected as 60%, 70% and 100% to isolate PS microparticles with diameters of 15.8, 10.8 and 5.8 µm, respectively. With a double light bar and a flow rate of 3 µL/min, the recovery rate and isolation purity was improved by 95.1~100% and 94.4~98.6% from the mixture of three types of PS microparticles within 2 min, respectively. This proposed light screening membrane could be a candidate for the separation of small-volume and rare biomedical samples, including circulating tumor cells (CTCs) and bacteria in the blood.
- 16 December 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (12) , 540
Open AccessVirtual Filter Membranes in a Microfluidic System for Sorting and Separating Size-Based Micro Polystyrene Beads by Illumination Intensity Design in Optically Induced Dielectrophoresis (ODEP)
In biomedical diagnosis, the efficient separation and purification of specific targets from clinical samples is the desired first step. Herein, the concept of virtual filter membranes based on optically-induced dielectrophoresis (ODEP) manipulation in a microfluidic channel is proposed as a light screening membrane for the separation of polystyrene (PS) microparticles with three different diameters of 15.8, 10.8 and 5.8 µm. The ODEP manipulation velocity of three types of PS microparticles reacted with the color brightness setting was investigated to determine the light intensity to induce an ODEP force higher than the drag force of fluid speed. The color brightness of the light bar in three areas of the light screening membrane was selected as 60%, 70% and 100% to isolate PS microparticles with diameters of 15.8, 10.8 and 5.8 µm, respectively. With a double light bar and a flow rate of 3 µL/min, the recovery rate and isolation purity was improved by 95.1~100% and 94.4~98.6% from the mixture of three types of PS microparticles within 2 min, respectively. This proposed light screening membrane could be a candidate for the separation of small-volume and rare biomedical samples, including circulating tumor cells (CTCs) and bacteria in the blood.
- Open Access
- 14 September 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (9) , 755
The Utilization of Tunable Transducer Elements Formed by the Manipulation of Magnetic Beads with Different Sizes via Optically Induced Dielectrophoresis (ODEP) for High Signal-to-Noise Ratios (SNRs) and Multiplex Fluorescence-Based Biosensing Applications
Magnetic beads improve biosensing performance by means of their small volume and controllability by magnetic force. In this study, a new technique composed of optically induced dielectrodphoresis (ODEP) manipulation and image processing was used to enhance the signal-to-noise ratio of the fluorescence for stained magnetic beads. According to natural advantages of size-dependent particle isolation by ODEP manipulation, biomarkers in clinical samples can be easily separated by different sizes of magnetic beads with corresponding captured antibodies, and rapidly distinguished by separated location of immunofluorescence. To verify the feasibility of the concept, magnetic beads with three different diameters, including 21.8, 8.7, and 4.2 μm, were easily separated and collected into specific patterns in the defined target zone treated as three dynamic transducer elements to evaluate fluorescence results. In magnetic beads with diameter of 4.2 μm, the lowest signal-to-noise ratio between stained and nonstained magnetic beads was 3.5. With the help of ODEP accumulation and detection threshold setting of 32, the signal-to-noise ratio was increased to 77.4, which makes this method more reliable. With the further optimization of specific antibodies immobilized on different-size magnetic beads in the future, this platform can be a potential candidate for a high-efficiency sensor array in clinical applications.
- 14 September 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (9) , 755
Open AccessThe Utilization of Tunable Transducer Elements Formed by the Manipulation of Magnetic Beads with Different Sizes via Optically Induced Dielectrophoresis (ODEP) for High Signal-to-Noise Ratios (SNRs) and Multiplex Fluorescence-Based Biosensing Applications
Magnetic beads improve biosensing performance by means of their small volume and controllability by magnetic force. In this study, a new technique composed of optically induced dielectrodphoresis (ODEP) manipulation and image processing was used to enhance the signal-to-noise ratio of the fluorescence for stained magnetic beads. According to natural advantages of size-dependent particle isolation by ODEP manipulation, biomarkers in clinical samples can be easily separated by different sizes of magnetic beads with corresponding captured antibodies, and rapidly distinguished by separated location of immunofluorescence. To verify the feasibility of the concept, magnetic beads with three different diameters, including 21.8, 8.7, and 4.2 μm, were easily separated and collected into specific patterns in the defined target zone treated as three dynamic transducer elements to evaluate fluorescence results. In magnetic beads with diameter of 4.2 μm, the lowest signal-to-noise ratio between stained and nonstained magnetic beads was 3.5. With the help of ODEP accumulation and detection threshold setting of 32, the signal-to-noise ratio was increased to 77.4, which makes this method more reliable. With the further optimization of specific antibodies immobilized on different-size magnetic beads in the future, this platform can be a potential candidate for a high-efficiency sensor array in clinical applications.
- Open Access
Enhancing Prediction Performance by Add-On Combining Circulating Tumor Cell Count, CD45neg EpCAMneg Cell Count on Colorectal Cancer, Advance, and Metastasis
Conventional circulating tumor cell (CTC) enumeration could ignore the CTCs more relevant to cancer metastasis. Thus, negative selection CTC enumeration was proposed, by which information on two cellular biomarkers (numbers of CTCs and CD45neg EpCAMneg cells) can be obtained. By combining this approach with the conventional biomarker carcinoembryonic antigen (CEA), this study aimed to explore whether any combination of these biomarkers could improve the predictive performance for colorectal cancer (CRC) or its status. In this work, these two cell populations in healthy donors and CRC patients were quantified. Results revealed that enumeration of these two cell populations was able to discriminate healthy donors from CRC patients, even patients with non-advanced CRC. Moreover, the combination of the two cell populations showed improved performance (AUROC: 0.893) for CRC prediction over the use of only one population. Compared with CEA alone, the combination of the three biomarkers increased the performance (AUROC) for advanced CRC prediction from 0.643 to 0.727. Compared with that of CEA alone for metastatic CRC prediction, the AUROC was increased from 0.780 to 0.837 when the CTC count was included. Overall, this study demonstrated that the combination of these two cellular biomarkers with CEA improved the predictive performance for CRC and its status.
Open AccessEnhancing Prediction Performance by Add-On Combining Circulating Tumor Cell Count, CD45neg EpCAMneg Cell Count on Colorectal Cancer, Advance, and Metastasis
Conventional circulating tumor cell (CTC) enumeration could ignore the CTCs more relevant to cancer metastasis. Thus, negative selection CTC enumeration was proposed, by which information on two cellular biomarkers (numbers of CTCs and CD45neg EpCAMneg cells) can be obtained. By combining this approach with the conventional biomarker carcinoembryonic antigen (CEA), this study aimed to explore whether any combination of these biomarkers could improve the predictive performance for colorectal cancer (CRC) or its status. In this work, these two cell populations in healthy donors and CRC patients were quantified. Results revealed that enumeration of these two cell populations was able to discriminate healthy donors from CRC patients, even patients with non-advanced CRC. Moreover, the combination of the two cell populations showed improved performance (AUROC: 0.893) for CRC prediction over the use of only one population. Compared with CEA alone, the combination of the three biomarkers increased the performance (AUROC) for advanced CRC prediction from 0.643 to 0.727. Compared with that of CEA alone for metastatic CRC prediction, the AUROC was increased from 0.780 to 0.837 when the CTC count was included. Overall, this study demonstrated that the combination of these two cellular biomarkers with CEA improved the predictive performance for CRC and its status.