Shurong Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shurong Wei has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Fangxing Li
University of Tennessee
3 shared publications Yao Xu
Pacific Gas and Electric Company, San Francisco, CA, USA
3 shared publications- Ren Zixu
Electric Power Engineering Shanghai University of Electric Power, Shanghai, China
2 shared publications Yang Fu
Department of Electrical Power Engineering Shanghai University of Electric power 2588 Changyang Road, Yangpu District Shanghai People's Republic of China
2 shared publications- Yang Fu
Engineering Research Center of Offshore Wind Technology Ministry of Education, Shanghai University of Electric Power, Shanghai, China
2 shared publications - Chao SiMa
School of Electrical Engineering, Shanghai University of Electric Power, Shanghai 200090, China
1 shared publication
Latest Publications
- 25 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 246-251
Game optimization of Environmental Friendly New Offshore Wind Farm Power Collection System
The electrical system of offshore wind farm is the key to deliver power to the onshore power grid. With the expansion of the scale of offshore wind farm, the traditional centralized offshore substation is facing the problems of large installation capacity and difficult construction. Therefore, a new technology-lightweight offshore substation, is introduced, and an improved k-medoids clustering method is proposed to establish the life cycle cost model of the new offshore wind farm collection system. In addition, considering the environmental impact, the collection system is optimized for different voltage levels, The Nash equilibrium theory of multiparty game evaluation is used to evaluate each scheme. Taking an offshore wind farm in a certain sea area as an example, the final results show that the integrated performance of the offshore wind farm collection system can be effectively improved by introducing the light substation and optimizing the voltage level.
- 25 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 246-251
Game optimization of Environmental Friendly New Offshore Wind Farm Power Collection System
The electrical system of offshore wind farm is the key to deliver power to the onshore power grid. With the expansion of the scale of offshore wind farm, the traditional centralized offshore substation is facing the problems of large installation capacity and difficult construction. Therefore, a new technology-lightweight offshore substation, is introduced, and an improved k-medoids clustering method is proposed to establish the life cycle cost model of the new offshore wind farm collection system. In addition, considering the environmental impact, the collection system is optimized for different voltage levels, The Nash equilibrium theory of multiparty game evaluation is used to evaluate each scheme. Taking an offshore wind farm in a certain sea area as an example, the final results show that the integrated performance of the offshore wind farm collection system can be effectively improved by introducing the light substation and optimizing the voltage level.
- 13 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 3007-3015
Using Flux Linkage Difference Vector in Early Inter-Turn Short Circuit Detection for the Windings of Offshore Wind DFIGs
Winding faults are the most commonly occurring type of fault in offshore doubly-fed generator units. Such faults are difficult to detect and repair, and therefore higher fault identification accuracy is required. Most of the existing research analyzes stator and rotor winding faults separately, but due to the coupling characteristics between windings, it is necessary to analyze doubly-fed induction generator (DFIG) winding faults in a unified way. This paper proposes a general fault diagnosis method that can be applied to both the stator and rotor winding faults of DFIGs. First, a general mathematical model of a windings short circuit of a doubly-fed generator is established. Then, according to the mechanism of a turn-to-turn short circuit fault of a DFIG and the expression of a bilateral flux linkage between stator winding and rotor winding, a new fault feature-bilateral flux linkage difference vector (FLDV) is obtained by mathematical derivation. Finally, the recommended value for an experimental motor of feature quantity is set. The proposed method for inter-turn fault (ITF) diagnosis of stator and rotor windings provides technical support for the sustainable development of offshore wind power. A simulation and experiment prove that FLDV has high sensitivity and high reliability for windings ITF diagnosis.
- 13 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 3007-3015
Using Flux Linkage Difference Vector in Early Inter-Turn Short Circuit Detection for the Windings of Offshore Wind DFIGs
Winding faults are the most commonly occurring type of fault in offshore doubly-fed generator units. Such faults are difficult to detect and repair, and therefore higher fault identification accuracy is required. Most of the existing research analyzes stator and rotor winding faults separately, but due to the coupling characteristics between windings, it is necessary to analyze doubly-fed induction generator (DFIG) winding faults in a unified way. This paper proposes a general fault diagnosis method that can be applied to both the stator and rotor winding faults of DFIGs. First, a general mathematical model of a windings short circuit of a doubly-fed generator is established. Then, according to the mechanism of a turn-to-turn short circuit fault of a DFIG and the expression of a bilateral flux linkage between stator winding and rotor winding, a new fault feature-bilateral flux linkage difference vector (FLDV) is obtained by mathematical derivation. Finally, the recommended value for an experimental motor of feature quantity is set. The proposed method for inter-turn fault (ITF) diagnosis of stator and rotor windings provides technical support for the sustainable development of offshore wind power. A simulation and experiment prove that FLDV has high sensitivity and high reliability for windings ITF diagnosis.
- Open Access
A Multi-Stage Coordinated Volt-Var Optimization for Integrated and Unbalanced Radial Distribution Networks
The growing penetrations of rooftop photovoltaics (PVs) into low-voltage (LV) distribution networks are challenging voltage regulation. Developing an effective volt-var (VV) control has been the focus of many researchers with various approaches proposed so far. However, assuming a single voltage level and balanced network model, widely adopted in existing literatures, tends to cause inaccurate and even infeasible control solutions. Besides, existing distribution VV control studies are usually based on the day-ahead predictions of PV generations and loads, introducing inevitable and non-negligible errors. To address the challenges above, this paper proposes a VV co-optimization across unbalanced medium-voltage (MV) and LV networks, by traditional and emerging techniques, to ensure the network operation with the required power quality. Specifically, the operation of MV delta-connected switched capacitors and LV distributed PV inverters is coordinated, under a three-stage strategy that suits integrated and unbalanced radial distribution networks. The proposal aims to simultaneously improve voltage magnitude and balance profiles while reducing network power loss, at the least controlling cost. To effectively solve the proposed VV optimization problem, a joint solver of the modified particle swarm optimization and the improved direct load flow is employed. Finally, the proposal is evaluated by simulations on real Australian distribution networks over 24 h.
Open AccessA Multi-Stage Coordinated Volt-Var Optimization for Integrated and Unbalanced Radial Distribution Networks
The growing penetrations of rooftop photovoltaics (PVs) into low-voltage (LV) distribution networks are challenging voltage regulation. Developing an effective volt-var (VV) control has been the focus of many researchers with various approaches proposed so far. However, assuming a single voltage level and balanced network model, widely adopted in existing literatures, tends to cause inaccurate and even infeasible control solutions. Besides, existing distribution VV control studies are usually based on the day-ahead predictions of PV generations and loads, introducing inevitable and non-negligible errors. To address the challenges above, this paper proposes a VV co-optimization across unbalanced medium-voltage (MV) and LV networks, by traditional and emerging techniques, to ensure the network operation with the required power quality. Specifically, the operation of MV delta-connected switched capacitors and LV distributed PV inverters is coordinated, under a three-stage strategy that suits integrated and unbalanced radial distribution networks. The proposal aims to simultaneously improve voltage magnitude and balance profiles while reducing network power loss, at the least controlling cost. To effectively solve the proposed VV optimization problem, a joint solver of the modified particle swarm optimization and the improved direct load flow is employed. Finally, the proposal is evaluated by simulations on real Australian distribution networks over 24 h.
- Open Access
- 24 July 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (18) , 3905-3912
Extended Park's vector method in early inter‐turn short circuit fault detection for the stator windings of offshore wind doubly‐fed induction generators
To avoid dramatic economic losses and unrecoverable failures in offshore wind farms, it is necessary to accurately detect faults at the early stage of doubly‐fed induction generators. The new extended Park's vector method is proposed in the study. The amplitude of the twice fundamental frequency component of the square of the Park's vector module is selected as the new fault feature to realise the early fault detection. The relationship between the extended Park's vector method and negative sequence current of the stator is also analysed in the study. The Fryze–Buchholz–Dpenbrock algorithm and the non‐linear least squares method are applied to estimate the mathematic relationship among unbalanced stator voltage, load change and the negative sequence current of the stator. The experiments were conducted and the results showed that the proposed method is robust to the effects of the unbalanced stator voltage and load change. Therefore, the proposed method can accurately detect faults at the early stage with high sensitivity and reliability.
- 24 July 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (18) , 3905-3912
Open AccessExtended Park's vector method in early inter‐turn short circuit fault detection for the stator windings of offshore wind doubly‐fed induction generators
To avoid dramatic economic losses and unrecoverable failures in offshore wind farms, it is necessary to accurately detect faults at the early stage of doubly‐fed induction generators. The new extended Park's vector method is proposed in the study. The amplitude of the twice fundamental frequency component of the square of the Park's vector module is selected as the new fault feature to realise the early fault detection. The relationship between the extended Park's vector method and negative sequence current of the stator is also analysed in the study. The Fryze–Buchholz–Dpenbrock algorithm and the non‐linear least squares method are applied to estimate the mathematic relationship among unbalanced stator voltage, load change and the negative sequence current of the stator. The experiments were conducted and the results showed that the proposed method is robust to the effects of the unbalanced stator voltage and load change. Therefore, the proposed method can accurately detect faults at the early stage with high sensitivity and reliability.
- 28 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 8 (3) , 1029-1039
Hierarchical Optimization for the Double-Sided Ring Structure of the Collector System Planning of Large Offshore Wind Farms
High reliability double-sided ring collector systems have been applied in practice for long distance and off the coast large-capacity offshore wind farms. To reduce investment and improve reliability, it is important to optimize and evaluate the double-sided ring collector systems. In this paper, a capital cost optimization model is developed to solve the mutual coupling effects among the system structure, power flow, and short circuit current in the collector system constraints. Based on the characteristics of the offshore electrical collector systems, the optimization model is divided into the offshore substation layer, the wind turbine layer, and the submarine cable layer. The fuzzy clustering algorithm, single parent genetic algorithm, and multiple traveling salesman solution technique are integrated and applied to solve the hierarchical optimization model. Finally, the proposed model and the optimization algorithms are tested in a real, large-scale offshore wind farm. The simulation results are compared with the radial collector systems from an economics and reliability point of view. The simulation results show that the double-sided ring design will achieve more profit with higher reliability in the long run. The results can also provide a benchmark for the collector system design of large-scale offshore wind farms.
- 28 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 8 (3) , 1029-1039
Hierarchical Optimization for the Double-Sided Ring Structure of the Collector System Planning of Large Offshore Wind Farms
High reliability double-sided ring collector systems have been applied in practice for long distance and off the coast large-capacity offshore wind farms. To reduce investment and improve reliability, it is important to optimize and evaluate the double-sided ring collector systems. In this paper, a capital cost optimization model is developed to solve the mutual coupling effects among the system structure, power flow, and short circuit current in the collector system constraints. Based on the characteristics of the offshore electrical collector systems, the optimization model is divided into the offshore substation layer, the wind turbine layer, and the submarine cable layer. The fuzzy clustering algorithm, single parent genetic algorithm, and multiple traveling salesman solution technique are integrated and applied to solve the hierarchical optimization model. Finally, the proposed model and the optimization algorithms are tested in a real, large-scale offshore wind farm. The simulation results are compared with the radial collector systems from an economics and reliability point of view. The simulation results show that the double-sided ring design will achieve more profit with higher reliability in the long run. The results can also provide a benchmark for the collector system design of large-scale offshore wind farms.