VSVijay Shetty

Vijay Shetty

*This is an algorithmically generated author record based on publicly available information.

Vijay Shetty has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of Spaeth/Richman Contrast Sensitivity and Pelli-Robson Tests for Assessing Contrast Sensitivity in Patients with Glaucoma

    by Fatema Noble, Suhas Haldipurkar, Vijay Shetty, Tanvi Haldipurkar, Rita Dhamankar, Devendra Venkatramani, Shreyas Dhamorikar, Sarita Deshpande, Maninder Singh Setia

    Purpose: To determine the optimal cut-offs for Pelli-Robson (PR) and Spaeth/Richman contrast sensitivity (SPARCS) test scores for diagnosing glaucoma and to compare PR and SPARCS scores (total and individual quadrants) for assessing contrast sensitivity in patients with glaucoma. Methods: This study was a single-center, cross-sectional, two-group analysis of 87 glaucomatous eyes and 87 non-glaucomatous control eyes. We assessed visual acuity, refraction, intraocular pressure (IOP), cup disc ratio (CDR), and anterior chamber depth in these patients. The PR score for central contrast sensitivity was obtained, and the SPARCS scores were generated for four outer zones and the central region. Results: The mean IOP [SD] was significantly higher in the glaucoma group (19.3 [5.2] mm Hg) compared with the control group (17.5 [3.6] mm Hg; P = 0.008). The mean CDR [SD] was significantly higher in the glaucoma group compared with the control group (0.73 [0.14] vs. 0.46 [0.12]; P < 0.001). The mean [SD] PR score (1.48 [0.17] vs. 1.23 [0.19]; P < 0.001) and total SPARCS score (78.2 [5.1] vs. 62.4 [11.2]; P < 0.001) were significantly higher in the control group compared with the glaucoma group. The optimal cut-off for identifying glaucoma was 1.35 for the PR score and 70 for the total SPARCS score. At this value of SPARCS score, the sensitivity for identifying glaucoma was 83.9% (95% CI, 74.5 to 90.9), specificity was 96.6% (95% CI, 90.3 to 99.3), positive predictive value (PPV) was 96.1% (95% CI, 88.9 to 99.2), and negative predictive value (NPV) was 85.7% (95% CI, 77.2 to 92.0). The area under the curve (AUC) value was significantly higher for the total SPARCS score compared with the PR score (0.92 vs. 0.83; P = 0.001). All individual SPARCS scores (superior nasal, superior temporal, central, inferior nasal, and inferior temporal) had lower AUC, sensitivity, specificity, PPV, and NPV values compared with the total SPARCS score. Conclusion: At the optimal cut-offs, the total SPARCS score offers significantly better diagnostic test properties for identifying glaucoma compared with the PR score.

  • Open Access

    Diagnostic Performance of the PalmScan VF2000 Virtual Reality Visual Field Analyzer for Identification and Classification of Glaucoma

    by Vijay Shetty, Prachi Sankhe, Suhas S Haldipurkar, Tanvi Haldipurkar, Rita Dhamankar, Priyanka Kashelkar, Dhruven Shah, Paresh Mhatre, Maninder Singh Setia

    Purpose: To evaluate the diagnostic test properties of the Palm Scan VF2000® Virtual Reality Visual Field Analyzer for diagnosis and classification of the severity of glaucoma. Methods: This study was a prospective cross-sectional analysis of 166 eyes from 97 participants. All of them were examined by the Humphrey® Field Analyzer (used as the gold standard) and the Palm Scan VF 2000® Virtual Reality Visual Field Analyzer on the same day by the same examiner. We estimated the kappa statistic (including 95% confidence interval [CI]) as a measure of agreement between these two methods. The diagnostic test properties were assessed using sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Results: The sensitivity, specificity, PPV, and NPV for the Virtual Reality Visual Field Analyzer for the classification of individuals as glaucoma/non-glaucoma was 100%. The general agreement for the classification of glaucoma between these two instruments was 0.63 (95% CI: 0.56–0.78). The agreement for mild glaucoma was 0.76 (95% CI: 0.61–0.92), for moderate glaucoma was 0.37 (0.14–0.60), and for severe glaucoma was 0.70 (95% CI: 0.55–0.85). About 28% of moderate glaucoma cases were misclassified as mild and 17% were misclassified as severe by the virtual reality visual field analyzer. Furthermore, 20% of severe cases were misclassified as moderate by this instrument. Conclusion: The instrument is 100% sensitive and specific in detection of glaucoma. However, among patients with glaucoma, there is a relatively high proportion of misclassification of severity of glaucoma. Thus, although useful for screening of glaucoma, it cannot replace the Humphrey® Field Analyzer for the clinical management in its current form.


  • Factors affecting changes in the intraocular pressure after phacoemulsification surgery

    by Rita Dhamankar, Suhas S Haldipurkar, Tanvi Haldipurkar, Vijay Shetty, Maninder Singh Setia, Nandini Chandok


  • Open Access

    Verion digital marking versus smartphone-assisted manual marking and isolated manual marking in toric intraocular lens implantation

    by Zain Irfan Khatib, Suhas S Haldipurkar, Vijay Shetty

    Purpose: To compare the accuracy of isolated manual marking and smartphone-assisted manual marking with the Verion image-guided system for toric intraocular lens (IOL) implantation. Methods: In this prospective observational study, 42 eyes of 36 patients planned for phacoemulsification with toric IOL implantation with corneal astigmatism >1D as measured on Lenstar LS 900 optical biometer were included. Patients were preoperatively registered and photographed on the Verion image-guided system. In the operating room, the patient's eye was manually marked at the 6 o′ clock limbus (Manual axis-90°) on slit-lamp in sitting position. Next, using the smartphone android app—iToric Patwardhan, the exact mark axis was confirmed (Smartphone axis). Following this, the patient was taken on the operation table where the mark axis was confirmed with Verion digital overlay on an external screen (Verion axis). The absolute angular deviation of manual axis from Verion was compared with the absolute angular deviation of the smartphone axis from Verion as the primary outcome measure. Results: The mean absolute angular deviation between the smartphone axis and the Verion axis was 2.62°, which was significantly lower (P < 0.05) than that between the manual axis and Verion axis (4.60°). Moreover, the intraclass correlation coefficient between the smartphone axis and Verion axis was 0.88 indicating a strong agreement between the two. Conclusion: Smartphone-assisted manual marking significantly improves the accuracy of manual marking alone when comparing with the Verion Digital Marker system for toric IOL implantation.


  • Incision size changes after cataract surgery with intraocular lens implantation: comparison of 2 preloaded IOL implantation injectors

    by Suhas S Doms Haldipurkar, Vijay Ms Shetty, Tanvi Haldipurkar, Rita Ms Dhamankar, Nancy Dnb Sehdev, Zain Ms Khatib, Pranoti Ms Nagvekar, Paresh Moptom Mhatre, Maninder Singh Setia

    Purpose: To compare incision size enlargement at different times of cataract surgery and visual outcomes after surgery in 2 different intraocular lens (IOL) delivery systems (Vivinex iSert and UltraSert Preloaded IOL Delivery System). Setting: Tertiary care eye institution. Design: Prospective nonrandomized comparison study. Methods: All eyes had uneventful temporal clear corneal phacoemulsification cataract surgery. The surgery was done by standard direct horizontal chop with a bimanual irrigation aspiration of the cortex. The primary incision size was measured after clear corneal incision, after the completion of phacoemulsification, and after IOL implantation. Results: The study comprised 276 eyes of 220 patients. The mean initial corneal incision was similar in both groups (2.2 mm). There was no significant difference in the mean incision size after phacoemulsification between the 2 groups (2.250 mm ± 0.068 mm [SD] vs 2.251 ± 0.066 mm [SD], P > .99). There was no significant difference in the mean (SD) incision size after IOL insertion between the 2 groups (2.367 ± 0.066 mm vs 2.369 ± 0.062 mm [SD], P = .815. The corrected distance visual acuity was 6/6 at 1 month in 80% of the participants in the UltraSert group and 86% in the Vivinex group. After adjusting for age, sex, grade of cataract, and IOL power, no significant difference was found in the magnitude of surgically induced astigmatism (SIA) in the Vivinex group compared with the UltraSert group (0.06, 95% CI, −0.11 to 0.24; P = .47). Conclusions: No significant difference was found in the change in the incision size, visual acuity, and SIA between UltraSert and Vivinex IOL delivery systems. This suggests that both IOL delivery systems are comparable in terms of post-IOL delivery incision enlargement for incisions of 2.2 mm.


  • A comparison of visual outcomes in three different types of monofocal intraocular lenses.

    by Vijay Shetty, Suhas S Haldipurkar, Rujuta Gore, Rita Dhamankar, Anirban Paik, Maninder Singh Setia

    To compare the visual outcomes (distance and near) in patients opting for three different types of monofocal intraocular lens (IOL) (Matrix Aurium, AcrySof single piece, and AcrySof IQ lens). The present study is a cross-sectional analysis of secondary clinical data collected from 153 eyes (52 eyes in Matrix Aurium, 48 in AcrySof single piece, and 53 in AcrySof IQ group) undergoing cataract surgery (2011-2012). We compared near vision, distance vision, distance corrected near vision in these three types of lenses on day 15 (±3) post-surgery. About 69% of the eyes in the Matrix Aurium group had good uncorrected distance vision post-surgery; the proportion was 48% and 57% in the AcrySof single piece and AcrySof IQ group (P=0.09). The proportion of eyes with good distance corrected near vision were 38%, 33%, and 15% in the Matrix Aurium, AcrySof single piece, and AcrySof IQ groups respectively (P=0.02). Similarly, The proportion with good "both near and distance vision" were 38%, 33%, and 15% in the Matrix Aurium, AcrySof single piece, and AcrySof IQ groups respectively (P=0.02). It was only the Matrix Aurium group which had significantly better both "distance and near vision" compared with the AcrySof IQ group (odds ratio: 5.87, 95% confidence intervals: 1.68 to 20.56). Matrix Aurium monofocal lenses may be a good option for those patients who desire to have a good near as well as distance vision post-surgery.