Krishna Alluri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Krishna Alluri has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Abdel K. Tahari
5 shared publicationsRichard L. Wahl
Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University, 601 N Caroline St, JHOC 3235, Baltimore, MD 21287
5 shared publications- Rathan M. Subramaniam
Russell H Morgan Department of Radiology and Radiological Sciences
4 shared publications Nasir Shariff
Franciscan Heart & Vascular Associates Gig Harbor, WA, 98332, USA
3 shared publicationsRathan M. Subramaniam
Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University, 601 N Caroline St, JHOC 3235, Baltimore, MD 21287
3 shared publications- Samir Saba
University of Pittsburgh Medical Center
3 shared publications
Latest Publications
- 27 July 2019
- Published by Springer Nature in Current Cardiology Reports
- Vol. 21 (9) , 94
Imaging Strategies for Evaluating Low-Flow, Low-Gradient Aortic Stenosis with Reduced and Preserved Left Ventricular Ejection Fraction
Aortic stenosis (AS) is one of the most common valvular heart diseases, and aortic valve replacement (AVR) provides both symptomatic and survival benefit in symptomatic severe AS patients. The purpose of this review is to discuss low-flow low-gradient AS which is still a challenging diagnostic entity. Thirty-forty percent of patients with AS have low flow which makes it difficult to differentiate truly severe AS that benefits from AVR compared to pseudo-severe AS which is currently managed conservatively. Patients with low-flow low-gradient AS (LF-LG AS) include those with reduced left ventricular systolic function (classical LF-LG AS) and those with preserved left ventricular systolic function (paradoxical LF-LG AS). Low-dose dobutamine stress echocardiography (DSE) helps to identify truly severe stenosis in patients with classical LF-LG AS. Aortic valve calcium scoring with multidetector computed tomography plays a major role in patients with paradoxical LF-LG AS and also among classical LF-LG AS patients who have reduced contractile reserve on DSE. This article will provide an overview of imaging strategies for evaluating LF-LG AS with reduced and preserved left ventricular ejection fraction.
- 27 July 2019
- Published by Springer Nature in Current Cardiology Reports
- Vol. 21 (9) , 94
Imaging Strategies for Evaluating Low-Flow, Low-Gradient Aortic Stenosis with Reduced and Preserved Left Ventricular Ejection Fraction
Aortic stenosis (AS) is one of the most common valvular heart diseases, and aortic valve replacement (AVR) provides both symptomatic and survival benefit in symptomatic severe AS patients. The purpose of this review is to discuss low-flow low-gradient AS which is still a challenging diagnostic entity. Thirty-forty percent of patients with AS have low flow which makes it difficult to differentiate truly severe AS that benefits from AVR compared to pseudo-severe AS which is currently managed conservatively. Patients with low-flow low-gradient AS (LF-LG AS) include those with reduced left ventricular systolic function (classical LF-LG AS) and those with preserved left ventricular systolic function (paradoxical LF-LG AS). Low-dose dobutamine stress echocardiography (DSE) helps to identify truly severe stenosis in patients with classical LF-LG AS. Aortic valve calcium scoring with multidetector computed tomography plays a major role in patients with paradoxical LF-LG AS and also among classical LF-LG AS patients who have reduced contractile reserve on DSE. This article will provide an overview of imaging strategies for evaluating LF-LG AS with reduced and preserved left ventricular ejection fraction.
- Open Access
- 1 May 2019
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 19 (3) , 100-103
Rate and predictors of electrical failure in non-recalled defibrillator leads
- 1 May 2019
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 19 (3) , 100-103
Open AccessRate and predictors of electrical failure in non-recalled defibrillator leads
- 1 July 2017
- Published by Elsevier in The American Journal of Cardiology
- Vol. 120 (1) , 83-86
Usefulness of the CHA 2 DS 2 -VASc Score to Predict Mortality in Defibrillator Recipients
- 1 July 2017
- Published by Elsevier in The American Journal of Cardiology
- Vol. 120 (1) , 83-86
Usefulness of the CHA 2 DS 2 -VASc Score to Predict Mortality in Defibrillator Recipients
- 1 July 2015
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 9 (4) , 337-344.e1
Distribution and burden of newly detected coronary artery calcium: Results from the Multi-Ethnic Study of Atherosclerosis
- 1 July 2015
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 9 (4) , 337-344.e1
Distribution and burden of newly detected coronary artery calcium: Results from the Multi-Ethnic Study of Atherosclerosis
- 1 May 2015
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 204 (5) , 1093-1099
Prognostic Value of FDG PET/CT–Derived Parameters in Pancreatic Adenocarcinoma at Initial PET/CT Staging
The purpose of this study is to evaluate the performance of PET-derived parameters as prognostic markers for overall survival (OS) and progression-free survival (PFS) outcome in patients with pancreatic adenocarcinoma. We conducted a retrospective study of 106 patients (62 men and 44 women) with histologically proven pancreatic adenocarcinoma who underwent initial staging FDG PET/CT before treatment. Peak standardized uptake value (SUV), maximum SUV (SUVmax), metabolic tumor volume, and tumor glycolytic activity of the primary pancreatic tumor were measured. Two segmentation methods were performed to obtain the metabolic tumor volume and tumor glycolytic activity for all tumors: a gradient-based segmentation model (metabolic tumor volume and tumor glycolytic activity by gradient edge detection) and a fixed-threshold model with a threshold of 50% of the lesion's SUVmax and peak SUV. Univariate and multivariate Cox regression models were developed including clinical and imaging parameters for OS and PFS. Multivariate Cox regression analysis showed a statistically significant association between PFS and age, SUVmax, peak SUV, and tumor glycolytic activity by gradient edge detection. There was a statistically significant difference in PFS for patients with values above and below the median cutoff points for SUVmax (hazard ratio [HR], 1.12; p < 0.01), peak SUV (HR, 1.25; p < 0.02), and tumor glycolytic activity measured by gradient edge detection (HR, 1.00; p < 0.02) of the primary tumor. However, multivariate Cox regression analysis showed a statistically significant association only between tumor glycolytic activity by gradient edge detection and OS (p = 0.04), and there was a statistically significant difference in OS between patients with values above and below the median cutoff point for the tumor glycolytic activity by gradient edge detection of the primary tumor (HR, 1.42; p = 0.05). Age, SUVmax, peak SUV, and total lesion glycolysis (i.e., tumor glycolytic activity) of the primary tumor are associated with PFS, and tumor glycolytic activity is associated with OS in patients with pancreatic adenocarcinoma.
- 1 May 2015
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 204 (5) , 1093-1099
Prognostic Value of FDG PET/CT–Derived Parameters in Pancreatic Adenocarcinoma at Initial PET/CT Staging
The purpose of this study is to evaluate the performance of PET-derived parameters as prognostic markers for overall survival (OS) and progression-free survival (PFS) outcome in patients with pancreatic adenocarcinoma. We conducted a retrospective study of 106 patients (62 men and 44 women) with histologically proven pancreatic adenocarcinoma who underwent initial staging FDG PET/CT before treatment. Peak standardized uptake value (SUV), maximum SUV (SUVmax), metabolic tumor volume, and tumor glycolytic activity of the primary pancreatic tumor were measured. Two segmentation methods were performed to obtain the metabolic tumor volume and tumor glycolytic activity for all tumors: a gradient-based segmentation model (metabolic tumor volume and tumor glycolytic activity by gradient edge detection) and a fixed-threshold model with a threshold of 50% of the lesion's SUVmax and peak SUV. Univariate and multivariate Cox regression models were developed including clinical and imaging parameters for OS and PFS. Multivariate Cox regression analysis showed a statistically significant association between PFS and age, SUVmax, peak SUV, and tumor glycolytic activity by gradient edge detection. There was a statistically significant difference in PFS for patients with values above and below the median cutoff points for SUVmax (hazard ratio [HR], 1.12; p < 0.01), peak SUV (HR, 1.25; p < 0.02), and tumor glycolytic activity measured by gradient edge detection (HR, 1.00; p < 0.02) of the primary tumor. However, multivariate Cox regression analysis showed a statistically significant association only between tumor glycolytic activity by gradient edge detection and OS (p = 0.04), and there was a statistically significant difference in OS between patients with values above and below the median cutoff point for the tumor glycolytic activity by gradient edge detection of the primary tumor (HR, 1.42; p = 0.05). Age, SUVmax, peak SUV, and total lesion glycolysis (i.e., tumor glycolytic activity) of the primary tumor are associated with PFS, and tumor glycolytic activity is associated with OS in patients with pancreatic adenocarcinoma.
- 1 March 2015
- Published by Elsevier in Atherosclerosis
- Vol. 239 (1) , 109-117
Scoring of coronary artery calcium scans: History, assumptions, current limitations, and future directions
- 1 March 2015
- Published by Elsevier in Atherosclerosis
- Vol. 239 (1) , 109-117
Scoring of coronary artery calcium scans: History, assumptions, current limitations, and future directions
- 15 January 2015
- Vol. 5 (2) , 154-61
Imaging modality utilization trends in patients with stage III-IV oropharyngeal squamous cell carcinoma.
The objective of this study is to establish the utilization trends of CT, MRI, and FDG-PET/CT for evaluation of oropharyngeal squamous cell carcinoma (OPSCC) patients. A total of 173 patients with newly diagnosed stage III or IV OPSCC between 2003 and 2009 were included. Frequency of imaging modality use, divided into four time periods (2003-04, 2005-06, 2007-08 and 2009), was evaluated. For initial staging, percentage of PET/CT use was 64.6%, 87.5%, 94.1% and 96.3%, with an increasing trend (p < 0.001). The CT (p = 0.762) and MRI (p = 0.224) use demonstrated no change in trend. For post-treatment imaging, percentage of PET/CT use was 59.5%, 68.6%, 89.7% and 100%, with an increasing trend (p < 0.001). The CT use demonstrated a decreasing trend (p = 0.004) and MRI showed no trend change (p = 0.231). PET/CT is used with an increasing trend for initial staging and has become a central imaging modality for follow up evaluation after treatment, for advanced OPSCC.
- 15 January 2015
- Vol. 5 (2) , 154-61
Imaging modality utilization trends in patients with stage III-IV oropharyngeal squamous cell carcinoma.
The objective of this study is to establish the utilization trends of CT, MRI, and FDG-PET/CT for evaluation of oropharyngeal squamous cell carcinoma (OPSCC) patients. A total of 173 patients with newly diagnosed stage III or IV OPSCC between 2003 and 2009 were included. Frequency of imaging modality use, divided into four time periods (2003-04, 2005-06, 2007-08 and 2009), was evaluated. For initial staging, percentage of PET/CT use was 64.6%, 87.5%, 94.1% and 96.3%, with an increasing trend (p < 0.001). The CT (p = 0.762) and MRI (p = 0.224) use demonstrated no change in trend. For post-treatment imaging, percentage of PET/CT use was 59.5%, 68.6%, 89.7% and 100%, with an increasing trend (p < 0.001). The CT use demonstrated a decreasing trend (p = 0.004) and MRI showed no trend change (p = 0.231). PET/CT is used with an increasing trend for initial staging and has become a central imaging modality for follow up evaluation after treatment, for advanced OPSCC.
- 1 January 2015
- Published by Elsevier in The American Journal of Cardiology
- Vol. 115 (2) , 202-205
Failure Rates of Single- Versus Dual-Coil Nonrecalled Sprint Quattro Defibrillator Leads
- 1 January 2015
- Published by Elsevier in The American Journal of Cardiology
- Vol. 115 (2) , 202-205
Failure Rates of Single- Versus Dual-Coil Nonrecalled Sprint Quattro Defibrillator Leads
- 1 January 2015
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 40 (1) , e17-e22
Liver Standardized Uptake Value Corrected for Lean Body Mass at FDG PET/CT
Objective The objective of this study is to establish the magnitude change and interreader reliability of the liver standardized uptake value corrected for lean body mass (SULmean) in dual-time-point imaging at 1 and 2 hours and 1 and 4 hours. Patients and Methods Early and delayed FDG PET/CT scans were included for 28 patients (13 men and 15 women) who had normal liver by CT or ultrasound. The average uptake time between the early and delayed scans were 55 minutes (range, 44–69 minutes) for pancreatic adenocarcinoma patients (n = 19) and 184 minutes (range, 140–197 minutes) for neurofibromatosis patients (n = 9). A 30-mm-diameter spherical volume of interest was placed within the right lobe of the liver above, below, and at the level of the main portal vein by 2 independent readers. Correlation coefficients, analysis of variance, intraclass correlation coefficient, and Bland-Altman analysis were performed. Results The mean liver SULmean was between 1.39 and 1.42 and between 1.28 and 1.3 in early and delayed images, respectively (P = 0.001). There is time-dependent reduction in the mean liver SULmean at 2-hour (7%–8%) and 4-hour uptake time (15%–21%) compared with 1-hour uptake time. The correlation coefficient between delayed uptake time and liver SULmean reduction is 0.39 to 0.41 at the upper aspect of the liver. The intraclass correlation coefficient for 2 readers varied between 0.997 and 0.998 and between 0.995 and 0.999 in early and delayed images, respectively (P = 0.001). Conclusions There is time-dependent reduction of mean liver SULmean, about 7% to 8% within the clinically relevant FDG uptake time, in the same patient with excellent interreader agreement in early and delayed images within the right lobe of the liver. Therefore, liver SULmean could represent a useful reference parameter in quantitative analysis of dual-phase FDG PET/CT in malignancy or atypical infection/inflammatory disease. Furthermore, it may be suitable as a normalization factor in currently available formulae quantifying therapy response on PET imaging.
- 1 January 2015
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 40 (1) , e17-e22
Liver Standardized Uptake Value Corrected for Lean Body Mass at FDG PET/CT
Objective The objective of this study is to establish the magnitude change and interreader reliability of the liver standardized uptake value corrected for lean body mass (SULmean) in dual-time-point imaging at 1 and 2 hours and 1 and 4 hours. Patients and Methods Early and delayed FDG PET/CT scans were included for 28 patients (13 men and 15 women) who had normal liver by CT or ultrasound. The average uptake time between the early and delayed scans were 55 minutes (range, 44–69 minutes) for pancreatic adenocarcinoma patients (n = 19) and 184 minutes (range, 140–197 minutes) for neurofibromatosis patients (n = 9). A 30-mm-diameter spherical volume of interest was placed within the right lobe of the liver above, below, and at the level of the main portal vein by 2 independent readers. Correlation coefficients, analysis of variance, intraclass correlation coefficient, and Bland-Altman analysis were performed. Results The mean liver SULmean was between 1.39 and 1.42 and between 1.28 and 1.3 in early and delayed images, respectively (P = 0.001). There is time-dependent reduction in the mean liver SULmean at 2-hour (7%–8%) and 4-hour uptake time (15%–21%) compared with 1-hour uptake time. The correlation coefficient between delayed uptake time and liver SULmean reduction is 0.39 to 0.41 at the upper aspect of the liver. The intraclass correlation coefficient for 2 readers varied between 0.997 and 0.998 and between 0.995 and 0.999 in early and delayed images, respectively (P = 0.001). Conclusions There is time-dependent reduction of mean liver SULmean, about 7% to 8% within the clinically relevant FDG uptake time, in the same patient with excellent interreader agreement in early and delayed images within the right lobe of the liver. Therefore, liver SULmean could represent a useful reference parameter in quantitative analysis of dual-phase FDG PET/CT in malignancy or atypical infection/inflammatory disease. Furthermore, it may be suitable as a normalization factor in currently available formulae quantifying therapy response on PET imaging.
- 1 October 2014
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 203 (4) , 897-903
Prognostic Value of FDG PET Metabolic Tumor Volume in Human Papillomavirus–Positive Stage III and IV Oropharyngeal Squamous Cell Carcinoma
OBJECTIVE. The purpose of this study was to establish the prognostic utility in human papillomavirus (HPV)–positive stage III and IV oropharyngeal squamous cell carcinoma (SCC) of the 18F-FDG param...
- 1 October 2014
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 203 (4) , 897-903
Prognostic Value of FDG PET Metabolic Tumor Volume in Human Papillomavirus–Positive Stage III and IV Oropharyngeal Squamous Cell Carcinoma
OBJECTIVE. The purpose of this study was to establish the prognostic utility in human papillomavirus (HPV)–positive stage III and IV oropharyngeal squamous cell carcinoma (SCC) of the 18F-FDG param...