Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Giovanni Emma has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Synthesis of 2,4,6-Trinitrotoluene (TNT) Using Flow Chemistry

    by Dimitris Kyprianou, Michael Berglund, Giovanni Emma, Grzegorz Rarata, David Anderson, Gabriela Diaconu, Vassiliki Exarchou

    This paper describes the nitration of 2,4-dinitrotoluene (DNT) and its conversion to 2,4,6-trinitrotoluene (TNT) at a gram scale with the use of a fully automated flow chemistry system. The conversion of DNT to TNT traditionally requires the use of highly hazardous reagents like fuming sulfuric acid (oleum), fuming nitric acid (90–100%), and elevated temperatures. Flow chemistry offers advantages compared to conventional syntheses including a high degree of safety and simpler multistep automation. The configuration and development of this automated process based on a commercially available flow chemistry system is described. A high conversion rate (>99%) was achieved. Unlike established synthetic methods, ordinary nitrating mixture (65% HNO3/98% H2SO4) and shorter reaction times (10–30 min) were applied. The viability of flow nitration as a means of safe and continuous synthesis of TNT was investigated. The method was optimized using an experimental design approach, and the resulting process is safer, faster, and more efficient than previously reported TNT synthesis procedures. We compared the flow chemistry and batch approaches, including a provisional cost calculation for laboratory-scale production (a thorough economic analysis is, however, beyond the scope of this article). The method is considered fit for purpose for the safe production of high-purity explosives standards at a gram scale, which are used to verify that the performance of explosive trace detection equipment complies with EU regulatory requirements.


  • Open Access

    Simple solid-phase spectrophotometric method for free iron(III) determination

    by Giancarla Alberti, Giovanni Emma, Roberta Colleoni, Valeria Marina Nurchi, Maria Pesavento, Raffaela Biesuz

    A simple and rapid solid-phase spectrophotometric procedure to determine free Fe(III) in\ud environmental and biological samples is proposed. In particular, a deferoxamine (DFO) self\ud assembled monolayer on mesoporous silica (DFO SAMMS) is developed and here applied as\ud sensor for iron(III). The solid product became brownish when put in contact with iron(III)\ud solutions; so an immediate application as colorimetric sensor is considered. In order to\ud optimise the DFO SAMMS synthesis and to obtain the best product for iron(III) sensing, a\ud factorial experimental design is performed selecting the maximum absorption at 425 nm as\ud response. The robustness of the spectrophotometric method is also proved


  • Open Access

    Feasibility study of a candidate reference material for ions in PM2.5: does commutability matter also for inorganic matrices?

    by G. Emma, J. Snell, J. Charoud-Got, A. Held, H. Emons

    The existing Air Quality Directive 2008/50/EC establishes within the European Union (EU) member states limit values for fine air particulate matter (PM2.5) including the possibility to discount natural sources of pollution when assessing compliance with the legislation. In proving this, EU member states shall determine, amongst others, the rural background concentration of some anions (Cl−, NO3− and SO42−) and cations (Na+, NH4+, K+, Ca2+ and Mg2+). To deliver reliable data and to comply with the data quality objectives of the legislation, environmental control laboratories should use certified reference materials (CRMs) to validate or verify the performance of their analytical methods. Since no CRMs for anions and cations in PM2.5 are presently available, we present the commutability issues encountered during the first attempt to develop such a material. We demonstrate that a dust, collected in a road tunnel and previously used for the production of two CRMs of a PM10-like material, does not behave as an authentic fine particulate matter collected according to EN12341:2014 when measured by an established method proposed by the European Committee for Standardization (CEN/TR 16269:2011). The water-soluble fractions of SO42−, NH4+, K+, Ca2+ and Mg2+ in a PM2.5-like candidate CRM produced from that road tunnel dust are only fully extracted after 3 h of sonication and not after 30 min, as stated in the method. Moreover, we found that the particle size of the test material influenced the extraction yield of K+, Ca2+ and Mg2+, suggesting that these ionic species were incorporated in the core of the particles and inaccessible to the extraction procedure. These particular features make the material unsuitable for the measurements of ions with the CEN method. The difference in the extraction time can be seen as a commutability issue and the candidate CRM should be considered as not commutable with routine samples. This demonstrates that commutability studies should not only be considered for clinical CRMs, but also for inorganic CRMs when they are intended to be used to quantify operationally defined analytes.


  • Open Access

    Preparation of a PM2.5-like reference material in sufficient quantities for accurate monitoring of anions and cations in fine atmospheric dust

    by Jean Charoud-Got, Giovanni Emma, John Seghers, Marie-France Tumba-Tshilumba, Anna Santoro, Andrea Held, James Snell, Håkan Emteborg

    A reference material of a PM2.5-like atmospheric dust material has been prepared using a newly developed method. It is intended to certify values for the mass fraction of SO4 2−, NO3 −, Cl− (anions) and Na+, K+, NH4 +, Ca2+, Mg2+ (cations) in this material. A successful route for the preparation of the candidate reference material is described alongside with two alternative approaches that were abandoned. First, a PM10-like suspension was allowed to stand for 72 h. Next, 90% of the volume was siphoned off. The suspension was spiked with appropriate levels of the desired ions just prior to drop-wise shock-freezing in liquid nitrogen. Finally, freeze drying of the resulting ice kernels took place. In using this approach, it was possible to produce about 500 g of PM2.5-like material with appropriate characteristics. Fine dust in 150-mg portions was filled into vials under an inert atmosphere. The final candidate material approaches the EN12341 standard of a PM2.5-material containing the ions mentioned in Directive 2008/50/EC of the European Union. The material should be analysed using the CEN/TR 16269:2011 method for anions and cations in PM2.5 collected on filters. The method described here is a relatively rapid means to obtain large quantities of PM2.5. With access to smaller freeze dryers, still 5 to 10 g per freeze-drying cycle can be obtained. Access to such quantities of PM2.5-like material could potentially be used for different kinds of experiments when performing research in this field.


  • A novel method for non-transferrin-bound iron quantification by chelatable fluorescent beads based on flow cytometry

    by Yongmin Ma, Maria Podinovskaia, Patricia J. Evans, Giovanni Emma, Ulrich E. Schaible, John Porter, Robert C. Hider

    The reliable measurement of non-transferrin-bound iron (NTBI) in serum has proved to be difficult and generally time consuming. We have sought a simple and fast method for such a determination. We adopted a fluorescence assay and designed a fluorescent dye with a chelating agent attached to sense iron. To avoid autofluorescence from serum samples, the iron probes were linked to beads and the autofluorescence could be separated and excluded from the measurement by flow cytometry due to the size difference between beads and serum proteins. Fluorescent beads containing both fluorescent and chelating moieties have been synthesized. The nature of the chelating function has been systematically investigated using four different chelators: bidentate hydroxypyranone, bidentate hydroxypyridinone, hexadentate hydroxypyranone and hexadentate hydroxypyridinone, each with different iron affinity constants. Competition studies demonstrate that the hexadentate hydroxypyridinone-based beads are capable of scavenging most of low molecular mass and albumin-bound iron but negligible amounts of iron from transferrin and ferritin. Serum samples from 30 patients with different types of disease and normal volunteers were measured. The concentrations of NTBI fall in the range −0.41 to +6.5 μM. The data have been compared with those obtained from the traditional ‘NTA’ method.


  • Open Access

    Novel DFO-SAM on mesoporous silica for iron sensing. Part I. Synthesis optimization and characterization of the material

    by Raffaela Biesuz, Giovanni Emma, Chiara Milanese, Giacomo Dacarro, Angelo Taglietti, Valeria Marina Nurchi, Giancarla Alberti

    The synthesis and the physico-chemical characterisation of a novel solid phase, designed for iron(III) sorption, are presented. The solid (indicated in the following as DFO-SAMMS) is made with a hydroxamate siderophore, the deferoxamine (DFO), covalently bound on a self-assembled monolayer on mesoporous silica (SAMMS). The data demonstrate that the DFO molecules are bound to the solid material, grafted on the surface and do not enter the silica pores. A new one-pot synthesis is presented in which DFO is dissolved in DMSO, and left to react with GPTMS with stirring overnight. In the same mixture, SAMMS is added to get the final product. The optimisation of experimental conditions of this novel one-pot synthesis is presented, with results indicating that a temperature of 90 °C, for the reaction between DFO and GPTMS, and the use of MCM-41 silica are the most convenient conditions. The kinetics of sorption reveals that the iron uptake is relatively fast, around 100 min at pH = 2.5, and from the sorption profile of iron(III), the estimated capacity of the product obtained under optimized conditions was higher than 0.3 mmol g−1. The results found in the present research are very promising for application in real biological samples.


  • Open Access

    Novel DFO-functionalized mesoporous silica for iron sensing. Part 2. Experimental detection of free iron concentration (pFe) in urine samples

    by Giancarla Alberti, Giovanni Emma, Roberta Colleoni, Maria Pesavento, Valeria Marina Nurchi, Raffaela Biesuz

    Successful in vivo chelation treatment of iron(III) overload pathologies requires that a significant fraction of the administered drug actually chelates the toxic metal. Increased mobilization of the iron(III) in experiments on animals or humans, most often evaluated from urinary output, is usually used as an assessment tool for chelation therapy. Alternatively, the efficiency of a drug is estimated by calculating the complexing ability of a chelating agent towards Fe(III). The latter is calculated by the pFe value, defined as the negative logarithm of the concentration of the free metal ion in a solution containing 10 μM total ligand and 1 μM total metal at a physiological pH of 7.4. In theory, pFe has to be calculated taking into account all the complexation equilibria involving the metal and the possible ligands. Nevertheless, complexation reactions in complex systems such as serum and urine may hardly be accurately modelled by computer software. The experimental determination of the bioavailable fraction of iron(III) in biological fluids would therefore be of the utmost relevance in the clinical practice. The efficiency of the therapy could be more easily estimated as well as the course of overload pathologies. In this context, the aim of the present work was the development of a sensor to assess the free iron directly in biological fluids (urine) of patients under treatment with chelating agents. In the proposed device (DFO-MS), the strong iron chelator deferoxamine (DFO) is immobilized on the MCM-41 mesoporous silica. The characterization of the iron(III) sorption on DFO-MS was undertaken, firstly in 0.1 M KNO3, then directly in urine samples, in order to identify the sorption mechanism. The stoichiometry of the reaction in the solid phase was found to be: with an exchange constant (average value) of log βex = 40(1). The application of DFO-MS to assess pFe in SPU (Simulating Pathology Urine) samples was also considered. The results obtained were very promising for a future validation and subsequent application of the sensor in samples of patients undergoing chelation therapy.


  • Open Access

    Pb(II), Cu(II) and Cd(II) Removal through Untreated Rice Husk; Thermodynamics and Kinetics

    by Maria Giovanna Guiso, Giancarla Alberti, Giovanni Emma, Maria Pesavento, Raffaela Biesuz

    The sorption properties of rice husk towards Cu(II), Cd(II) and Pb(II) were studied. The sorption isotherms are described by the Langmuir equation, and Pb(II) shows a higher affinity for rice husk compared to Cu(II) and Cd(II) under the same conditions. The kinetics of sorption obeys to a pseudo second-order equation for all metals. The sorption profiles as a function of the pH were used to characterize the stoichiometry of the sorption reaction. The competition for metal complexation by any ligand in solution is also accounted for. Upon increasing the ionic strength, the sorption curves of Pb(II) move to basic pH; this shift can be explained by considering the effect of nitrate complexes on the free metal ion concentration, since KNO3 is used as the ionic medium. An attempt to employ rice husk in a dynamic system is presented.