Kagan Ege Karakus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kagan Ege Karakus has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
- Halis Kaan Akturk
Barbara Davis Center for Diabetes, University of Colorado, Aurora, Colorado, USA
8 shared publications - Gül Yeşiltepe Mutlu
Koç University Faculty of Medicine, Division of Pediatrics Endocrinology, Istanbul, Türkiye
6 shared publications - Elif Eviz
Department of Pediatric Endocrinology and Diabetes, Faculty of Medicine, Koc University, Istanbul, Turkey
5 shared publications - Şükrü Hatun
Department of Pediatric Endocrinology and Diabetes, Faculty of Medicine, Koc University, Istanbul, Turkey
5 shared publications Ecem Can
12School of Medicine, Department of Pediatric Endocrinology and Diabetes, Koc University, Istanbul, Turkey
4 shared publications- Tuğba Gökçe
Koç University Hospital, Istanbul, Turkey
4 shared publications
Latest Publications
- Open Access
- 29 July 2026
- Published by Elsevier in SSRN Electronic Journal
Stigma in adults with type 1 diabetes and its association with glycemic control: insights into communication preferences
Objectives:This study aimed to explore patients’ preferences regarding communication language used in patient–clinician interactions and their relationship with perceived stigma in adults with type 1 diabetes. As a secondary objective, we evaluated the association between perceived stigma and glycemic control.Methods:This cross-sectional study was conducted between September 2023 and September 2024, including 171 adults with type 1 diabetes. Participants completed the validated Type 1 Diabetes Stigma Assessment Scale (DSAS-1). In addition, a 24-item questionnaire was used to evaluate preferences for communication expressions used by healthcare professionals. For subgroup analyses, participants were stratified into three categories based on HbA1c levels (7.5%). DSAS-1 total and subscale scores were compared across HbA1c categories. Communication-related items were analyzed descriptively as exploratory outcomes.Results:The median DSAS-1 score was 46.0 [37–54]. DSAS-1 total scores differed significantly across HbA1c categories (p=0.021). Individuals with HbA1c >7.5% demonstrated higher stigma scores compared to those with HbA1c <6.5% (post hoc p=0.009). Health-promoting and patient-centered expressions were generally preferred over stigmatizing communication statements. However, a substantial proportion of participants rejected certain empathy- and exploratory-framed statements. This finding indicates variability in the perceived acceptability of supportive communication styles. In contrast, preferences for directive or explicitly discriminatory expressions were not significantly associated with stigma levels. Conclusion: The use of patient-centered, empowering, and nonjudgmental communication is associated with more favorable perceptions; however, well-intentioned, patient-centered expressions may not be perceived as supportive by all patients so language should be tailored to individual stigma experiences. Practice Implications: Communication with individuals with type 1 diabetes should be individualized and sensitive to stigma-related perceptions. Clinicians should incorporate stigma awareness into routine communication and adopt a flexible, individualized approach, recognizing that even well-intentioned expressions may not be perceived as supportive by all patients.
- 29 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessStigma in adults with type 1 diabetes and its association with glycemic control: insights into communication preferences
Objectives:This study aimed to explore patients’ preferences regarding communication language used in patient–clinician interactions and their relationship with perceived stigma in adults with type 1 diabetes. As a secondary objective, we evaluated the association between perceived stigma and glycemic control.Methods:This cross-sectional study was conducted between September 2023 and September 2024, including 171 adults with type 1 diabetes. Participants completed the validated Type 1 Diabetes Stigma Assessment Scale (DSAS-1). In addition, a 24-item questionnaire was used to evaluate preferences for communication expressions used by healthcare professionals. For subgroup analyses, participants were stratified into three categories based on HbA1c levels (7.5%). DSAS-1 total and subscale scores were compared across HbA1c categories. Communication-related items were analyzed descriptively as exploratory outcomes.Results:The median DSAS-1 score was 46.0 [37–54]. DSAS-1 total scores differed significantly across HbA1c categories (p=0.021). Individuals with HbA1c >7.5% demonstrated higher stigma scores compared to those with HbA1c <6.5% (post hoc p=0.009). Health-promoting and patient-centered expressions were generally preferred over stigmatizing communication statements. However, a substantial proportion of participants rejected certain empathy- and exploratory-framed statements. This finding indicates variability in the perceived acceptability of supportive communication styles. In contrast, preferences for directive or explicitly discriminatory expressions were not significantly associated with stigma levels. Conclusion: The use of patient-centered, empowering, and nonjudgmental communication is associated with more favorable perceptions; however, well-intentioned, patient-centered expressions may not be perceived as supportive by all patients so language should be tailored to individual stigma experiences. Practice Implications: Communication with individuals with type 1 diabetes should be individualized and sensitive to stigma-related perceptions. Clinicians should incorporate stigma awareness into routine communication and adopt a flexible, individualized approach, recognizing that even well-intentioned expressions may not be perceived as supportive by all patients.
- Open Access
- 24 February 2026
- Published by Galenos Yayinevi in Journal of Clinical Research in Pediatric Endocrinology
- Vol. 18 (1) , 48-57
Improving Diabetes Care Through Teamwork, Comprehensive Education, Tighter Goals, and Technology: Single-Center Data from Türkiye
Improving Diabetes Care Through Teamwork, Comprehensive Education, Tighter Goals, and Technology: Single-Center Data from Türkiye - Journal of Clinical Research in Pediatric Endocrinology
- 24 February 2026
- Published by Galenos Yayinevi in Journal of Clinical Research in Pediatric Endocrinology
- Vol. 18 (1) , 48-57
Open AccessImproving Diabetes Care Through Teamwork, Comprehensive Education, Tighter Goals, and Technology: Single-Center Data from Türkiye
Improving Diabetes Care Through Teamwork, Comprehensive Education, Tighter Goals, and Technology: Single-Center Data from Türkiye - Journal of Clinical Research in Pediatric Endocrinology
- Top Cited PapersOpen Access
- 15 January 2026
- Published by Springer Nature in Diabetologia
- Vol. 69 (5) , 1164-1175
Teplizumab treatment for stage 2 type 1 diabetes: a real-world evaluation of metabolic and immunological outcomes
Aims/hypothesis This is the first real-world prospective observational study of teplizumab use following approval by the United States Food and Drug Administration in individuals with stage 2 type 1 diabetes. We examined whether glycaemic responses observed in controlled trials were reproduced in real-world practice and explored immunological biomarkers associated with treatment. Methods Children and adults with stage 2 type 1 diabetes were prospectively followed in the Early Type 1 Diabetes Clinic at the Barbara Davis Center. Individuals who received teplizumab between April 2023 and February 2025 (n=30) were compared with an untreated group (n=10). Key assessments included OGTTs, HbA1c measurements and continuous glucose monitoring (CGM) data, collected before and after treatment. Longitudinal metabolic data were available for up to 22 treated participants, with follow-up assessments occurring between 2 and 13 months after treatment. Changes in Epstein–Barr virus (EBV) and islet antigen-targeting T cell receptor (TCR) β chains were measured longitudinally from genomic DNA via a PCR-based targeted TCR sequencing assay. Results Among treated individuals followed up between 2 and 6 months after treatment, OGTT 2 h glucose improved (10.7 ± 2.1 to 8.8 ± 2.8 mmol/l, p=0.007), as did HbA1c (40 ± 4 to 39 ± 6 mmol/mol [5.8 ± 0.4% to 5.7 ± 0.5%], p=0.044). In addition, 67% had a stable or reduced CGM time ≥7.8 mmol/l. CD4 preproinsulin-specific TCRs declined after treatment, with no change in the untreated group. These reductions correlated with higher C-peptide AUC (r=−0.656, p=0.013). EBV TCR sequences were similar before and after teplizumab treatment. Conclusions/interpretation Teplizumab can be safely and effectively administered in clinical practice. Early glycaemic improvements and reductions in CD4 preproinsulin-specific TCRs suggest that post-treatment immunological changes may serve as biomarkers to guide early-stage intervention. Graphical Abstract
- 15 January 2026
- Published by Springer Nature in Diabetologia
- Vol. 69 (5) , 1164-1175
Top Cited PapersOpen AccessTeplizumab treatment for stage 2 type 1 diabetes: a real-world evaluation of metabolic and immunological outcomes
Aims/hypothesis This is the first real-world prospective observational study of teplizumab use following approval by the United States Food and Drug Administration in individuals with stage 2 type 1 diabetes. We examined whether glycaemic responses observed in controlled trials were reproduced in real-world practice and explored immunological biomarkers associated with treatment. Methods Children and adults with stage 2 type 1 diabetes were prospectively followed in the Early Type 1 Diabetes Clinic at the Barbara Davis Center. Individuals who received teplizumab between April 2023 and February 2025 (n=30) were compared with an untreated group (n=10). Key assessments included OGTTs, HbA1c measurements and continuous glucose monitoring (CGM) data, collected before and after treatment. Longitudinal metabolic data were available for up to 22 treated participants, with follow-up assessments occurring between 2 and 13 months after treatment. Changes in Epstein–Barr virus (EBV) and islet antigen-targeting T cell receptor (TCR) β chains were measured longitudinally from genomic DNA via a PCR-based targeted TCR sequencing assay. Results Among treated individuals followed up between 2 and 6 months after treatment, OGTT 2 h glucose improved (10.7 ± 2.1 to 8.8 ± 2.8 mmol/l, p=0.007), as did HbA1c (40 ± 4 to 39 ± 6 mmol/mol [5.8 ± 0.4% to 5.7 ± 0.5%], p=0.044). In addition, 67% had a stable or reduced CGM time ≥7.8 mmol/l. CD4 preproinsulin-specific TCRs declined after treatment, with no change in the untreated group. These reductions correlated with higher C-peptide AUC (r=−0.656, p=0.013). EBV TCR sequences were similar before and after teplizumab treatment. Conclusions/interpretation Teplizumab can be safely and effectively administered in clinical practice. Early glycaemic improvements and reductions in CD4 preproinsulin-specific TCRs suggest that post-treatment immunological changes may serve as biomarkers to guide early-stage intervention. Graphical Abstract
- 11 September 2025
- Published by SAGE Publications in Diabetes Technology & Therapeutics
Exploring the Relationship Between Newly Defined Continuous Glucose Monitoring (CGM) Metrics and the Standard CGM Metrics in 30,000 People with Type 1 Diabetes
Background: Rebound hyperglycemia (RHyper), rebound hypoglycemia (RHypo), extended hyperglycemia (EHyper), and extended hypoglycemia (EHypo) are newly defined continuous glucose monitoring (CGM) metrics. Here, we investigated the characteristics of these new metrics and the relationship between new CGM metrics and standard metrics. Materials and Methods: In this retrospective cohort study, 30,000 CGM users with at least 90 days of CGM data were randomly selected from Dexcom Clarity database. Standard and new CGM metrics were calculated for each user. Four different cutoffs were used to define RHyper and RHypo, and two cutoffs were used to define EHyper and EHypo events. The number of RHyper, RHypo, EHyper, and EHypo events per week, mean duration of events, and mean area under the curve of events were calculated. For rebound events, the rate of change (ROC) was calculated. Pearson correlation and simple linear regression were used to analyze the data. Results: Mean time in 70-180 mg/dL was 61.8 ± 20.7%, mean glucose was 173 ± 37.1 mg/dL, and coefficient of variation (CV) was 32.1 ± 7.2%. RHyper, RHypo, and EHyper were more frequent during daytime and increased throughout the day. EHypo mostly occurred during nighttime. CV correlated strongly with RHyper (70-180 mg/dL) events/week (r = 0.67) and RHypo (180 to 70 mg/dL) events/week (r = 0.64). Time in range had the strongest correlation with EHyper events/week (r = -0.88) among new metrics. RHyper events and RHypo events were strongly correlated with each other (r = 0.92). RHyper and RHypo ROC have a stronger correlation with CV than the correlation between CV and time below range (TBR) metrics. Conclusions: For rebound and extended metrics, the most important metric was the number of events/week. RHyper and RHypo had a stronger correlation with CV and hypoglycemia metrics (TBR) than the correlation between CV and TBR. Thus, rebound events have the potential to detect hypoglycemia events caused by glycemic variability. [Figure: see text].
- 11 September 2025
- Published by SAGE Publications in Diabetes Technology & Therapeutics
Exploring the Relationship Between Newly Defined Continuous Glucose Monitoring (CGM) Metrics and the Standard CGM Metrics in 30,000 People with Type 1 Diabetes
Background: Rebound hyperglycemia (RHyper), rebound hypoglycemia (RHypo), extended hyperglycemia (EHyper), and extended hypoglycemia (EHypo) are newly defined continuous glucose monitoring (CGM) metrics. Here, we investigated the characteristics of these new metrics and the relationship between new CGM metrics and standard metrics. Materials and Methods: In this retrospective cohort study, 30,000 CGM users with at least 90 days of CGM data were randomly selected from Dexcom Clarity database. Standard and new CGM metrics were calculated for each user. Four different cutoffs were used to define RHyper and RHypo, and two cutoffs were used to define EHyper and EHypo events. The number of RHyper, RHypo, EHyper, and EHypo events per week, mean duration of events, and mean area under the curve of events were calculated. For rebound events, the rate of change (ROC) was calculated. Pearson correlation and simple linear regression were used to analyze the data. Results: Mean time in 70-180 mg/dL was 61.8 ± 20.7%, mean glucose was 173 ± 37.1 mg/dL, and coefficient of variation (CV) was 32.1 ± 7.2%. RHyper, RHypo, and EHyper were more frequent during daytime and increased throughout the day. EHypo mostly occurred during nighttime. CV correlated strongly with RHyper (70-180 mg/dL) events/week (r = 0.67) and RHypo (180 to 70 mg/dL) events/week (r = 0.64). Time in range had the strongest correlation with EHyper events/week (r = -0.88) among new metrics. RHyper events and RHypo events were strongly correlated with each other (r = 0.92). RHyper and RHypo ROC have a stronger correlation with CV than the correlation between CV and time below range (TBR) metrics. Conclusions: For rebound and extended metrics, the most important metric was the number of events/week. RHyper and RHypo had a stronger correlation with CV and hypoglycemia metrics (TBR) than the correlation between CV and TBR. Thus, rebound events have the potential to detect hypoglycemia events caused by glycemic variability. [Figure: see text].
- 23 March 2025
- Published by Elsevier in Primary Care Diabetes
- Vol. 19 (3) , 341-343
Barriers to glucagon use in patients with type 1 diabetes
- 23 March 2025
- Published by Elsevier in Primary Care Diabetes
- Vol. 19 (3) , 341-343
Barriers to glucagon use in patients with type 1 diabetes
- 1 March 2025
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 27 (3) , 202-208
Comparison of Computational Statistical Packages for the Analysis of Continuous Glucose Monitoring Data with a Reference Software, “Ambulatory Glucose Profile,” in Type 1 Diabetes
Objective: To compare the accuracy of commonly used continuous glucose monitoring (CGM) analysis programs with ambulatory glucose profile (AGP) and Dexcom Clarity (DC) in analyzing CGM metrics in patients with type 1 diabetes (T1D). Research Methods: CGM data up to 90 days from 152 adults using the same CGM and automated insulin delivery system with T1D were collected. Six of the 19 CGM analysis programs (CDGA, cgmanalysis, Glyculator, iglu, EasyGV, and GLU) were selected to compare with AGP and DC. Metrics were compared etween all tools with two one-sided t-tests equivalence testing. For the equivalence test, the acceptable range of deviation was set as ±2 mg/dL for mean glucose, ±2% for time in range (TIR), ±1% for time above range (TAR), time above range level 1 (TAR1), time above range level 2 (TAR2), and coefficient of variation (CV). Results: All packages were compared with each other for all CGM metrics, and most of them had statistically significant differences for at least some metrics. All tools were equivalent to AGP for mean glucose, TIR, TAR, TAR1, and TAR2 within ±2 mg/dL, ±2%, ±1%, ±1% and 1%, respectively. CDGA, Glyculator, cgmanalysis, and iglu were not equivalent to AGP for CV within ±1%. All tools were equivalent to DC for mean glucose, TIR, and TAR2 within ±2 mg/dL, ±2%, and ±1%, respectively. Glyculator was not equivalent for TAR1, TAR, and CV. CGDA, cgmanalysis, and iglu were not equivalent to DC for TAR1 and TAR. EasyGV and GLU were not equivalent for TAR within ±1%. Conclusions: CGM analysis programs reported CGM metrics statistically differently, but these differences may not be applicable in clinical practice. The equivalence test also confirmed that the differences are negligible for TIR and mean glucose, while they can be important for hyperglycemic ranges and CV. A standardization for CGM data handling and analysis is necessary for clinical studies reporting CGM-generated outcomes.
- 1 March 2025
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 27 (3) , 202-208
Comparison of Computational Statistical Packages for the Analysis of Continuous Glucose Monitoring Data with a Reference Software, “Ambulatory Glucose Profile,” in Type 1 Diabetes
Objective: To compare the accuracy of commonly used continuous glucose monitoring (CGM) analysis programs with ambulatory glucose profile (AGP) and Dexcom Clarity (DC) in analyzing CGM metrics in patients with type 1 diabetes (T1D). Research Methods: CGM data up to 90 days from 152 adults using the same CGM and automated insulin delivery system with T1D were collected. Six of the 19 CGM analysis programs (CDGA, cgmanalysis, Glyculator, iglu, EasyGV, and GLU) were selected to compare with AGP and DC. Metrics were compared etween all tools with two one-sided t-tests equivalence testing. For the equivalence test, the acceptable range of deviation was set as ±2 mg/dL for mean glucose, ±2% for time in range (TIR), ±1% for time above range (TAR), time above range level 1 (TAR1), time above range level 2 (TAR2), and coefficient of variation (CV). Results: All packages were compared with each other for all CGM metrics, and most of them had statistically significant differences for at least some metrics. All tools were equivalent to AGP for mean glucose, TIR, TAR, TAR1, and TAR2 within ±2 mg/dL, ±2%, ±1%, ±1% and 1%, respectively. CDGA, Glyculator, cgmanalysis, and iglu were not equivalent to AGP for CV within ±1%. All tools were equivalent to DC for mean glucose, TIR, and TAR2 within ±2 mg/dL, ±2%, and ±1%, respectively. Glyculator was not equivalent for TAR1, TAR, and CV. CGDA, cgmanalysis, and iglu were not equivalent to DC for TAR1 and TAR. EasyGV and GLU were not equivalent for TAR within ±1%. Conclusions: CGM analysis programs reported CGM metrics statistically differently, but these differences may not be applicable in clinical practice. The equivalence test also confirmed that the differences are negligible for TIR and mean glucose, while they can be important for hyperglycemic ranges and CV. A standardization for CGM data handling and analysis is necessary for clinical studies reporting CGM-generated outcomes.
- 19 February 2025
- Published by Elsevier in Canadian Journal of Diabetes
- Vol. 49 (3) , 218-219
Cannabis Hyperemesis Syndrome Can Mimic Diabetic Gastroparesis in Cannabis Users With Type 1 Diabetes
- 19 February 2025
- Published by Elsevier in Canadian Journal of Diabetes
- Vol. 49 (3) , 218-219
Cannabis Hyperemesis Syndrome Can Mimic Diabetic Gastroparesis in Cannabis Users With Type 1 Diabetes
- 14 February 2025
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 20 (4) , 1159-1163
Progression of Diabetic Retinopathy After Initiation of Automated Insulin Delivery System in Adults With Type 1 Diabetes
Background: To evaluate the progression of diabetic retinopathy (DR) after the initiation of automated insulin delivery (AID) systems in adults with type 1 diabetes (T1D). Methods: In this longitudinal study with 152 adults, retinal exams and clinical variables were collected before and after AID initiation up to 2.7 years. The DR worsening was defined as an increase in Early Treatment of Diabetic Retinopathy Study (ETDRS) scores or qualitative retinal exam. Results: A total of 152 adults with mean age of 42 years (57% female), 26 years of T1D duration, and mean baseline HbA 1c of 7.6% (60 mmol/mol) were included in this analysis. Of 152 adults with T1D, 42 (28%) adults had DR worsening after AID initiation. After adjusting for age, diabetes duration, and sex, baseline HbA 1c (odds ratio [OR] = 2.1 [1.34-3.04]) and low-density lipoprotein cholesterol (LDL-C) >100 mg/dL with HbA 1c >8% (OR = 3.33 [1.12-9.91]) were associated with two- and three-fold increased risk for DR worsening, respectively. The decline of HbA 1c with AID initiation between DR worsening and no-DR worsening groups was not significant (−0.38 ± 1.2% vs −0.47 ± 0.9%; P = .6). Conclusions: Higher baseline HbA 1c with LDL-C >100 mg/dL may be associated with DR worsening after initiation of AID systems in T1D. Those with elevated HbA 1c should get periodic ophthalmic examination after AID initiation to detect progression of DR. Prompt diagnosis may result in timely treatment.
- 14 February 2025
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 20 (4) , 1159-1163
Progression of Diabetic Retinopathy After Initiation of Automated Insulin Delivery System in Adults With Type 1 Diabetes
Background: To evaluate the progression of diabetic retinopathy (DR) after the initiation of automated insulin delivery (AID) systems in adults with type 1 diabetes (T1D). Methods: In this longitudinal study with 152 adults, retinal exams and clinical variables were collected before and after AID initiation up to 2.7 years. The DR worsening was defined as an increase in Early Treatment of Diabetic Retinopathy Study (ETDRS) scores or qualitative retinal exam. Results: A total of 152 adults with mean age of 42 years (57% female), 26 years of T1D duration, and mean baseline HbA 1c of 7.6% (60 mmol/mol) were included in this analysis. Of 152 adults with T1D, 42 (28%) adults had DR worsening after AID initiation. After adjusting for age, diabetes duration, and sex, baseline HbA 1c (odds ratio [OR] = 2.1 [1.34-3.04]) and low-density lipoprotein cholesterol (LDL-C) >100 mg/dL with HbA 1c >8% (OR = 3.33 [1.12-9.91]) were associated with two- and three-fold increased risk for DR worsening, respectively. The decline of HbA 1c with AID initiation between DR worsening and no-DR worsening groups was not significant (−0.38 ± 1.2% vs −0.47 ± 0.9%; P = .6). Conclusions: Higher baseline HbA 1c with LDL-C >100 mg/dL may be associated with DR worsening after initiation of AID systems in T1D. Those with elevated HbA 1c should get periodic ophthalmic examination after AID initiation to detect progression of DR. Prompt diagnosis may result in timely treatment.
- 5 December 2024
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 20 (3) , 721-726
Improvement in Newly Defined Continuous Glucose Monitor Metrics, Extended Hypoglycemia, and Extended Hyperglycemia With Automated Insulin Delivery Initiation in Adults With Type 1 Diabetes
Objective: Extended hypoglycemia (Ehypo) and extended hyperglycemia (Ehyper) are recently defined continuous glucose monitoring (CGM) metrics by the International Consensus for clinical trials as secondary endpoints for continuous outcomes. This study aims to evaluate the changes in Ehypo and Ehyper before and after automated insulin delivery (AID) initiation in adults with type 1 diabetes (T1D). Research Methods: This is a retrospective single-center study that evaluated Ehypo and Ehyper in addition to other CGM metrics in 154 adults that initiated an AID system. Metrics were compared before and after AID initiation by Wilcoxon signed-rank test. Results: Median (interquartile range) Ehypo (250 mg/dL) events/week decreased from 2.2 (0.9-4.5) to 0.8 (0.3-1.7) (both P < .001) after AID initiation compared with before AID initiation. All other CGM metrics improved after AID initiation. There was a strong positive correlation between Ehyper (>250 mg/dL) and mean glucose (before AID: r = 0.947, after AID: r = 0.894), glucose management indicator (before AID: r = 0.947, after AID: r = 0.887), and time above range (TAR; >180 mg/dL) (before AID: r = 0.957, after AID: r = 0.917) and a strong positive correlation between Ehypo (r = 0.823, after AID: r = 0.608) before and after AID initiation, respectively. Conclusion: Automated insulin delivery initiation significantly improved Ehypo and Ehyper metrics. Ehypo and Ehyper had a strong positive correlation with TBR and TAR, respectively. Ehypo and Ehyper events can be used in addition to TBR and TAR metrics in clinical studies as secondary outcomes.
- 5 December 2024
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 20 (3) , 721-726
Improvement in Newly Defined Continuous Glucose Monitor Metrics, Extended Hypoglycemia, and Extended Hyperglycemia With Automated Insulin Delivery Initiation in Adults With Type 1 Diabetes
Objective: Extended hypoglycemia (Ehypo) and extended hyperglycemia (Ehyper) are recently defined continuous glucose monitoring (CGM) metrics by the International Consensus for clinical trials as secondary endpoints for continuous outcomes. This study aims to evaluate the changes in Ehypo and Ehyper before and after automated insulin delivery (AID) initiation in adults with type 1 diabetes (T1D). Research Methods: This is a retrospective single-center study that evaluated Ehypo and Ehyper in addition to other CGM metrics in 154 adults that initiated an AID system. Metrics were compared before and after AID initiation by Wilcoxon signed-rank test. Results: Median (interquartile range) Ehypo (250 mg/dL) events/week decreased from 2.2 (0.9-4.5) to 0.8 (0.3-1.7) (both P < .001) after AID initiation compared with before AID initiation. All other CGM metrics improved after AID initiation. There was a strong positive correlation between Ehyper (>250 mg/dL) and mean glucose (before AID: r = 0.947, after AID: r = 0.894), glucose management indicator (before AID: r = 0.947, after AID: r = 0.887), and time above range (TAR; >180 mg/dL) (before AID: r = 0.957, after AID: r = 0.917) and a strong positive correlation between Ehypo (r = 0.823, after AID: r = 0.608) before and after AID initiation, respectively. Conclusion: Automated insulin delivery initiation significantly improved Ehypo and Ehyper metrics. Ehypo and Ehyper had a strong positive correlation with TBR and TAR, respectively. Ehypo and Ehyper events can be used in addition to TBR and TAR metrics in clinical studies as secondary outcomes.
- 25 November 2024
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 19 (2) , 582-583
Glycemic and Patient-Reported Outcomes for Users of a New, Compact Automated Insulin Delivery System: A First Report
- 25 November 2024
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 19 (2) , 582-583
Glycemic and Patient-Reported Outcomes for Users of a New, Compact Automated Insulin Delivery System: A First Report