Rodrigo Bernardo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rodrigo Bernardo has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Paulo Jorge Sequeira Gonçalves
IDMEC, Instituto Politcnico de Castelo Branco, Castelo Branco, Portugal
6 shared publications - Marco P. Soares dos Santos
Department of Mechanical Engineering, Centre for Mechanical Technology & Automation (TEMA), University of Aveiro, Aveiro, Portugal
3 shared publications André Rodrigues
Department of Mechanical Engineering, University of Aveiro, Aveiro, Portugal
2 shared publications- Antonio Ramos
Departamento de Engenharia Mecânica, Universidade de Aveiro, 3810-193 Aveiro, Portugal
2 shared publications - Jorge A. Fernandes Ferreira
Department of Mechanical Engineering, University of Aveiro, Aveiro, Portugal
2 shared publications - Joãao Borges de Sousa
IDMEC, Instituto Superior Técnico, University of Lisbon, Av. Rovisco Pais 1, 1049-001 Lisbon, Portugal
2 shared publications
Latest Publications
- Open Access
- 19 November 2024
- Published by Elsevier in Robotics and Autonomous Systems
- Vol. 184
Ontological framework for high-level task replanning for autonomous robotic systems
- 19 November 2024
- Published by Elsevier in Robotics and Autonomous Systems
- Vol. 184
Open AccessOntological framework for high-level task replanning for autonomous robotic systems
- 27 April 2024
- Published by Springer Nature
- p. 3-13
The Use of Semantic Knowledge in Task Planning for Robotic Agents, Minimising Human Error
- 27 April 2024
- Published by Springer Nature
- p. 3-13
The Use of Semantic Knowledge in Task Planning for Robotic Agents, Minimising Human Error
- Open Access
A Novel Control Architecture Based on Behavior Trees for an Omni-Directional Mobile Robot
Robotic systems are increasingly present in dynamic environments. This paper proposes a hierarchical control structure wherein a behavior tree (BT) is used to improve the flexibility and adaptability of an omni-directional mobile robot for point stabilization. Flexibility and adaptability are crucial at each level of the sense–plan–act loop to implement robust and effective robotic solutions in dynamic environments. The proposed BT combines high-level decision making and continuous execution monitoring while applying non-linear model predictive control (NMPC) for the point stabilization of an omni-directional mobile robot. The proposed control architecture can guide the mobile robot to any configuration within the workspace while satisfying state constraints (e.g., obstacle avoidance) and input constraints (e.g., motor limits). The effectiveness of the controller was validated through a set of realistic simulation scenarios and experiments in a real environment, where an industrial omni-directional mobile robot performed a point stabilization task with obstacle avoidance in a workspace.
Open AccessA Novel Control Architecture Based on Behavior Trees for an Omni-Directional Mobile Robot
Robotic systems are increasingly present in dynamic environments. This paper proposes a hierarchical control structure wherein a behavior tree (BT) is used to improve the flexibility and adaptability of an omni-directional mobile robot for point stabilization. Flexibility and adaptability are crucial at each level of the sense–plan–act loop to implement robust and effective robotic solutions in dynamic environments. The proposed BT combines high-level decision making and continuous execution monitoring while applying non-linear model predictive control (NMPC) for the point stabilization of an omni-directional mobile robot. The proposed control architecture can guide the mobile robot to any configuration within the workspace while satisfying state constraints (e.g., obstacle avoidance) and input constraints (e.g., motor limits). The effectiveness of the controller was validated through a set of realistic simulation scenarios and experiments in a real environment, where an industrial omni-directional mobile robot performed a point stabilization task with obstacle avoidance in a workspace.
- Open Access
- 27 May 2023
- Published by Elsevier in Computers & Industrial Engineering
- Vol. 182
A novel framework to improve motion planning of robotic systems through semantic knowledge-based reasoning
- 27 May 2023
- Published by Elsevier in Computers & Industrial Engineering
- Vol. 182
Open AccessA novel framework to improve motion planning of robotic systems through semantic knowledge-based reasoning
- 6 October 2022
- Published by Elsevier in Journal of Manufacturing Systems
- Vol. 65, 339-350
Survey on robotic systems for internal logistics
- 6 October 2022
- Published by Elsevier in Journal of Manufacturing Systems
- Vol. 65, 339-350
Survey on robotic systems for internal logistics
- Open Access
- 1 January 2021
- Published by OAE Publishing Inc. in Intelligence & Robotics
- Vol. 1 (2) , 101-115
Planning robotic agent actions using semantic knowledge for a home environment
Intelligence & Robotics publishes top-quality unpublished original technical and non-technical application-focused articles on intelligence and robotics, particularly on the interdisciplinary areas of intelligence and robotics.
- 1 January 2021
- Published by OAE Publishing Inc. in Intelligence & Robotics
- Vol. 1 (2) , 101-115
Open AccessPlanning robotic agent actions using semantic knowledge for a home environment
Intelligence & Robotics publishes top-quality unpublished original technical and non-technical application-focused articles on intelligence and robotics, particularly on the interdisciplinary areas of intelligence and robotics.
- Open Access
Altering the Course of Technologies to Monitor Loosening States of Endoprosthetic Implants
Musculoskeletal disorders are becoming an ever-growing societal burden and, as a result, millions of bone replacements surgeries are performed per year worldwide. Despite total joint replacements being recognized among the most successful surgeries of the last century, implant failure rates exceeding 10% are still reported. These numbers highlight the necessity of technologies to provide an accurate monitoring of the bone–implant interface state. This study provides a detailed review of the most relevant methodologies and technologies already proposed to monitor the loosening states of endoprosthetic implants, as well as their performance and experimental validation. A total of forty-two papers describing both intracorporeal and extracorporeal technologies for cemented or cementless fixation were thoroughly analyzed. Thirty-eight technologies were identified, which are categorized into five methodologies: vibrometric, acoustic, bioelectric impedance, magnetic induction, and strain. Research efforts were mainly focused on vibrometric and acoustic technologies. Differently, approaches based on bioelectric impedance, magnetic induction and strain have been less explored. Although most technologies are noninvasive and are able to monitor different loosening stages of endoprosthetic implants, they are not able to provide effective monitoring during daily living of patients.
Open AccessAltering the Course of Technologies to Monitor Loosening States of Endoprosthetic Implants
Musculoskeletal disorders are becoming an ever-growing societal burden and, as a result, millions of bone replacements surgeries are performed per year worldwide. Despite total joint replacements being recognized among the most successful surgeries of the last century, implant failure rates exceeding 10% are still reported. These numbers highlight the necessity of technologies to provide an accurate monitoring of the bone–implant interface state. This study provides a detailed review of the most relevant methodologies and technologies already proposed to monitor the loosening states of endoprosthetic implants, as well as their performance and experimental validation. A total of forty-two papers describing both intracorporeal and extracorporeal technologies for cemented or cementless fixation were thoroughly analyzed. Thirty-eight technologies were identified, which are categorized into five methodologies: vibrometric, acoustic, bioelectric impedance, magnetic induction, and strain. Research efforts were mainly focused on vibrometric and acoustic technologies. Differently, approaches based on bioelectric impedance, magnetic induction and strain have been less explored. Although most technologies are noninvasive and are able to monitor different loosening stages of endoprosthetic implants, they are not able to provide effective monitoring during daily living of patients.
- 30 August 2019
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 73 (1) , 77-84
Novel magnetic stimulation methodology for low-current implantable medical devices
Recent studies highlight the ability of inductive architectures to deliver therapeutic magnetic stimuli to target tissues and to be embedded into small-scale intracorporeal medical devices. However, to date, current micro-scale biomagnetic devices require very high electric current excitations (usually exceeding 1 A) to ensure the delivery of efficient magnetic flux densities. This is a critical problem as advanced implantable devices demand self-powering, stand-alone and long-term operation. This work provides, for the first time, a novel small-scale magnetic stimulation system that requires up to 50-fold lower electric current excitations than required by relevant biomagnetic technology recently proposed. Computational models were developed to analyse the magnetic stimuli distributions and densities delivered to cellular tissues during in vitro experiments, such that the feasibility of this novel stimulator can be firstly evaluated on cell culture tests. The results demonstrate that this new stimulative technology is able to deliver osteogenic stimuli (0.1-7 mT range) by current excitations in the 0.06-4.3 mA range. Moreover, it allows coil designs with heights lower than 1 mm without significant loss of magnetic stimuli capability. Finally, suitable core diameters and stimulator-stimulator distances allow to define heterogeneity or quasi-homogeneity stimuli distributions. These results support the design of high-sophisticated biomagnetic devices for a wide range of therapeutic applications.
- 30 August 2019
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 73 (1) , 77-84
Novel magnetic stimulation methodology for low-current implantable medical devices
Recent studies highlight the ability of inductive architectures to deliver therapeutic magnetic stimuli to target tissues and to be embedded into small-scale intracorporeal medical devices. However, to date, current micro-scale biomagnetic devices require very high electric current excitations (usually exceeding 1 A) to ensure the delivery of efficient magnetic flux densities. This is a critical problem as advanced implantable devices demand self-powering, stand-alone and long-term operation. This work provides, for the first time, a novel small-scale magnetic stimulation system that requires up to 50-fold lower electric current excitations than required by relevant biomagnetic technology recently proposed. Computational models were developed to analyse the magnetic stimuli distributions and densities delivered to cellular tissues during in vitro experiments, such that the feasibility of this novel stimulator can be firstly evaluated on cell culture tests. The results demonstrate that this new stimulative technology is able to deliver osteogenic stimuli (0.1-7 mT range) by current excitations in the 0.06-4.3 mA range. Moreover, it allows coil designs with heights lower than 1 mm without significant loss of magnetic stimuli capability. Finally, suitable core diameters and stimulator-stimulator distances allow to define heterogeneity or quasi-homogeneity stimuli distributions. These results support the design of high-sophisticated biomagnetic devices for a wide range of therapeutic applications.
- Open Access
- 21 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-20
Capacitive technologies for highly controlled and personalized electrical stimulation by implantable biomedical systems
Cosurface electrode architectures are able to deliver personalized electric stimuli to target tissues. As such, this technology holds potential for a variety of innovative biomedical devices. However, to date, no detailed analyses have been conducted to evaluate the impact of stimulator architecture and geometry on stimuli features. This work characterizes, for the first time, the electric stimuli delivered to bone cellular tissues during in vitro experiments, when using three capacitive architectures: stripped, interdigitated and circular patterns. Computational models are presented that predict the influence of cell confluence, cosurface architecture, electrodes geometry, gap size between electrodes and power excitation on the stimuli delivered to cellular layers. The results demonstrate that these stimulators are able to deliver osteoconductive stimuli. Significant differences in stimuli distributions were observed for different stimulator designs and different external excitations. The thickness specification was found to be of utmost importance. In vitro experiments using an osteoblastic cell line highlight that cosurface stimulation at a low frequency can enhance osteoconductive responses, with some electrode-specific differences being found. A major feature of this type of work is that it enables future detailed analyses of stimuli distribution throughout more complex biological structures, such as tissues and organs, towards sophisticated biodevice personalization.
- 21 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-20
Open AccessCapacitive technologies for highly controlled and personalized electrical stimulation by implantable biomedical systems
Cosurface electrode architectures are able to deliver personalized electric stimuli to target tissues. As such, this technology holds potential for a variety of innovative biomedical devices. However, to date, no detailed analyses have been conducted to evaluate the impact of stimulator architecture and geometry on stimuli features. This work characterizes, for the first time, the electric stimuli delivered to bone cellular tissues during in vitro experiments, when using three capacitive architectures: stripped, interdigitated and circular patterns. Computational models are presented that predict the influence of cell confluence, cosurface architecture, electrodes geometry, gap size between electrodes and power excitation on the stimuli delivered to cellular layers. The results demonstrate that these stimulators are able to deliver osteoconductive stimuli. Significant differences in stimuli distributions were observed for different stimulator designs and different external excitations. The thickness specification was found to be of utmost importance. In vitro experiments using an osteoblastic cell line highlight that cosurface stimulation at a low frequency can enhance osteoconductive responses, with some electrode-specific differences being found. A major feature of this type of work is that it enables future detailed analyses of stimuli distribution throughout more complex biological structures, such as tissues and organs, towards sophisticated biodevice personalization.
- Open Access
- 12 November 2017
- Published by Springer Nature
- p. 441-451
Knowledge and Tasks Representation for an Industrial Robotic Application
- 12 November 2017
- Published by Springer Nature
- p. 441-451
Open AccessKnowledge and Tasks Representation for an Industrial Robotic Application