MAMohammad Mahdi Aeinehvand

Mohammad Mahdi Aeinehvand

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mohammad Mahdi Aeinehvand has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automated High-Throughput Microfluidic Platform for Cell Pairing and Chemical Fusion

    by Robinzon Silvestre-De-León, Everardo González-González, Roberto Rodriguez-Mocayo, José Antonio Cruz-Cardenas, Sergio O. Martinez-Chapa, Joel Voldman, Mohammad Mahdi Aeinehvand

    Cell fusion enables cell-based applications, yet systematic optimization remains constrained by low throughput (microfluidic devices) and manual operation (bulk protocols). Here, an automated microfluidic platform is presented for cell pairing and chemical fusion at a statistically relevant scale. High throughput is achieved by arranging ~350,000 deformability-based cell traps as concentric circular arrays in a radial chip. Using tumor and dendritic cells as a model for cancer vaccine, the device reproducibly co-occupies ~75% of traps (~250,000) of which ~140,000 hold exactly one cell of each type. This exceeds the yield of previously reported in hydrodynamic pairing arrays by more than an order of magnitude. A concentration step-up-and-down PEG profile yielded a fusion efficiency of ~20% (range 17.7-23.4%, n =3) at viability above 90% that results in producing at least ~50,000 hybrids per chip. This efficiency is comparable to that reported for PEG-based fusion in small-scale microfluidic devices but obtained at higher throughput and approximately four-fold higher than the conventional benchtop protocol. Fusion efficiencies were quantified by image analysis and validated by flow cytometry. By combining automation, large-area circular trap arrays and reagent control, the platform is useful for data-rich optimization of cell engineering processes previously constrained by limited microfluidic throughput.

  • Top Cited Papers
    Open Access

    Polymeric and biological membranes for organ-on-a-chip devices

    by Kendra Corral-Nájera, Gaurav Chauhan, Sergio O. Serna-Saldívar, Sergio O. Martínez-Chapa, Mohammad Mahdi Aeinehvand

    Membranes are fundamental elements within organ-on-a-chip (OOC) platforms, as they provide adherent cells with support, allow nutrients (and other relevant molecules) to permeate/exchange through membrane pores, and enable the delivery of mechanical or chemical stimuli. Through OOC platforms, physiological processes can be studied in vitro, whereas OOC membranes broaden knowledge of how mechanical and chemical cues affect cells and organs. OOCs with membranes are in vitro microfluidic models that are used to replace animal testing for various applications, such as drug discovery and disease modeling. In this review, the relevance of OOCs with membranes is discussed as well as their scaffold and actuation roles, properties (physical and material), and fabrication methods in different organ models. The purpose was to aid readers with membrane selection for the development of OOCs with specific applications in the fields of mechanistic, pathological, and drug testing studies. Mechanical stimulation from liquid flow and cyclic strain, as well as their effects on the cell’s increased physiological relevance (IPR), are described in the first section. The review also contains methods to fabricate synthetic and ECM (extracellular matrix) protein membranes, their characteristics (e.g., thickness and porosity, which can be adjusted depending on the application, as shown in the graphical abstract), and the biological materials used for their coatings. The discussion section joins and describes the roles of membranes for different research purposes and their advantages and challenges.


  • (Digital Presentation) An Electrochemical Sensor in a Disc for Real-Time PCR Assisted with Thermal Convective Flow

    by Fabian Oswaldo Romero-Soto, Mohammad Mahdi Aeinehvand, Marc Madou, Sergio Omar Martinez-Chapa

    Nowadays, the polymerase chain reaction (PCR) has extensively adapted to microfluidic devices for several features such as the low consumption of reagents and sample, portability, high-throughput, and low fabrication costs [1]. The reduction of the amplification time has been a relevant parameter since the invention of the PCR, where rapid microfluidic PCR is especially preferred for the detection of infectious diseases [1,2]. The continuous-flow-based PCR is a type of microfluidic PCR that proposes the mobilization of the PCR mixture through a microchannel with different fixed temperature zones to achieve the required thermal-cycling [3]. This approach has smaller thermal inertia because only the PCR mixture needs to be heated and cooled instead of the entire microfluidic device. The continuous-flow approach allows rapid-thermal cycling with lower power consumption and, therefore, reduces the overall amplification time. The Lab-on-a-disc, or centrifugal microfluidic platform, has adapted the continuous-flow PCR by utilizing the flow generated by thermal convection in a ring-structured microchannel [4]. During spinning, embedded heaters in the bottom of the CD heat specific section of the microchannel (see Figure 1) at a fixed temperature and, subsequently, create a natural convection flow in the PCR mixture and move through the microchannel. The centrifugal-assisted thermal convection (CATC) technique not only enables the recirculation pathway for the continuous-flow PCR but overcomes the unidirectional nature of centrifugation force on the CD. Despite the advantage of rapid PCR on Lab-on-a-Disc, the CATC technique lacks the implementation of a detection method with high sensitivity and resolution, aiming for a fully integrated microfluidic platform. Electrochemical detection can provide fast responses with minimum power consumption for miniaturized devices. This work proposes the integration of an electrochemical sensor to the CATC technique in a circular microchannel for the real-time monitoring of DNA amplification. The electrochemical sensor consists of interdigitated gold electrodes located above the ring microchannel to quantify the amplicon concentration after each cycle mediated by the intercalation of Methylene Blue between the newly-generated DNA (see figure 1A). The characterization of the sensor is performed through voltammetric techniques such as cyclic voltammetry (CV) and linear sweep voltammetry (LSV), where the latter is utilized for amplicon quantification. To optimize the CATC technique combined with the electrochemical sensor, a COMSOL simulation is performed to improve the amplification ratio and amplification time in the CD by analyzing the microchannel geometry and flow rate (see figure 1B). Both the thermal control for the thermal-assisted microchannel and the electrochemical sensor are powered and controlled via the “electrified Lab-on-a-Disc” (eLoaD) board [5] (see figure 1C). [1] Y. Zhang, P. Ozdemir, Anal. Chim. Acta 638 (2009) 115–125. [2] X. Dong, L. Liu, Y. Tu, J. Zhang, G. Miao, L. Zhang, S. Ge, N. Xia, D. Yu, X. Qiu, TrAC - Trends Anal. Chem. 143 (2021) 116377. [3] M.B. Kulkarni, S. Goel, Eng. Res. Express 2 (2020). [4] M. Saito, K. Takahashi, Y. Kiriyama, W.V. Espulgar, H. Aso, T. Sekiya, Y. Tanaka, T. Sawazumi, S. Furui, E. Tamiya, Anal. Chem. 89 (2017) 12797–12804. [5] S.M. Torres Delgado, J.G. Korvink, D. Mager, Biosens. Bioelectron. 117 (2018) 464–473. Figure 1

  • (Digital Presentation) An Electrochemical Sensor in a Disc for Real-Time PCR Assisted with Thermal Convective Flow

    by Fabian Oswaldo Romero-Soto, Mohammad Mahdi Aeinehvand, Marc Madou, Sergio Omar Martinez-Chapa

    Multiple microfluidic devices incorporating real-time polymerase chain reaction (PCR) for the quantification of DNA targets have been reported. They show features such as fast analysis time, reduced reagent consumption, and portability. Integration of real-time PCR in a centrifugal microfluidic disc has been also proposed due to the ease of automation and parallelization of microfluidic operations. Previously, it has been demonstrated the implementation of thermal convective PCR (TC-PCR) in a CD using a ring-structured microchannel. In this case, the microchannel is supplied with the temperature necessary to perform the complete thermal cycle: Denaturation, annealing, and extension. The flow generated by thermal convection, in combination with the centrifugal force moves the sample through the entire microchannel due to the difference in densities. In this work, we present the implementation in a CD of an electrochemical sensor combined with TC-PCR to quantify the amplification yield in real-time. We present advances related to the calibration of the electrochemical sensor, and the implementation of the TC-PCR in a CD as well as a preliminary simulation in COMSOL.

  • Elastic reversible valves on centrifugal microfluidic platforms

    by Mohammad Mahdi Aeinehvand, Laura Weber, Martín Jiménez, Andrea Palermo, Maria Bauer, Felix F. Loeffler, Fatimah Ibrahim, Frank Breitling, Jan Korvink, Marc Madou, et al.

    We developed and modeled tunable reversible valves on microfluidic discs, and employed them to automate a multiplexed immunoassay with peptide microarrays.


  • Aluminium valving and magneto-balloon mixing for rapid prediction of septic shock on centrifugal microfluidic platforms

    by M. Mahdi Aeinehvand, Rute Fabiana Martins Fernandes, Martín Francisco Jiménez Moreno, Víctor Javier Lara Díaz, Marc Madou, Sergio O. Martinez-Chapa


  • Origami Microfluidic CD

    by MohammadMahdi Aeinehvand, Patricia Sosa Silva, Beatriz Bosques Palomo, Flor Helena Valencia Velarde, Gladys Diaz Armas, Eduardo Caballero Saldivar, Marc J Madou, Sergio Omar Martinez-Chapa

    Employing the centrifugal force for liquid displacement in bioanalytical compact discs (CDs) is becoming more popular for academic and industry applications. Pseudo forces that are controlled by a low-cost spindle motor enables the simultaneous manipulation of several liquids on the microfluidic CD. For this reason, centrifugal microfluidic platforms are considered more robust for extreme point of care (ePOC) applications when compared to stationary microfluidic systems that work with mechanical liquids pumps (e.g., syringe pump). However, the fabrication of microfluidic CDs requires expensive and bulky equipment (e.g., router or laser CNC) that cannot be implemented at ePOC and point of need (PON). To cope with this limitation, we have introduced a rapid microfluidic CD fabrication technique using only a low-cost cutter plotter [1]. The CDs were made through assembly of thin PVC and double-sided pressure sensitive adhesive (PSA) layers that were cut by the plotter machine. However, the technique yet required careful assembly of several disc layers, and the double-sided PSA is an expensive material and not widely available. In this article, we introduce a new origami CD fabrication process using only one type of material, a cutter plotter and a laminating machine. The origami CDs fabrication process prevents the need for PSA film and the tedious/sensitive CD assembly procedure. Therefore, the origami CDs facilitates onsite development of automated diagnosis test at ePOC and PON with minimum and widely available material and equipment. In addition to the origami CD fabrication process, this study includes the characterization of different microchannels made by the cutter plotter blade. Finally, as an application of the CD fabrication technique we developed an origami CD for automated serial dilution that is required for a wide range of bioanalytical applications such as microbial counting and multiplexed assay. [1] M.M. Aeinehvand, P. Magaña, M.S. Aeinehvand, O. Aguilar, M.J. Madou, S.O. Martinez-Chapa, Ultra-rapid and low-cost fabrication of centrifugal microfluidic platforms with active mechanical valves, RSC Adv. 7 (2017) 55400–55407. doi:10.1039/C7RA11532F.

  • Electrolysis Pumping on Centrifugal Microfluidic Platforms for Automation of Bioanalytical Assays

    by Fabian Oswaldo Romero Soto, MohammadMahdi Aeinehvand, Martin Francisco Jimenez Moreno, Dario Mager, Marc J Madou, Sergio Omar Martínez-Chapa

    One of the advantages of Lab on a Disc (LoD), compared to Lab on a Chip (LoC), is the use of centrifugal forces to move liquids within the chambers and microchannels; eliminating the need of external mechanical pumps (e.g., syringe pump) and piping networks for the automatization of bioanalytical assays. However, the centrifugal force is unidirectional and therefore liquids can only be displaced from the center to the edge of the disc. This prevents the possibility of utilizing all the available space in the disc for the implementation of a complex microfluidic process. To overcome this limitation, we developed an electrolysis system to induce a pneumatic force to move liquids towards the center of a spinning disc or against the direction of centrifugal force. We developed a microfluidic disc that contains a series of electrolysis pumps and peptide microarrays to automate a multiplexed immunoassay for the detection of different antibodies e.g., Ha and anti-flag antibodies. The pumps on this centrifugal microfluidic platform are powered and controlled wirelessly using the electronics-LoD [1]. In general, the develop pumping system allows for the best use of the limited space of microfluidic disc and the automation of complex bioanalytical process for point of care applications. [1] S.M.T. Delgado, D.J. Kinahan, F.S. Sandoval, L.A.N. Julius, N.A. Kilcawley, J. Ducrée, D. Mager, Fully automated chemiluminescence detection using an electrified-Lab-on-a-Disc (eLoaD) platform, Lab Chip. 16 (2016) 4002–4011. doi:10.1039/C6LC00973E.


  • Carbon Iso-Dielectric Separation (CIDS) on Centrifugal Microfluidic Platforms

    by MohammadMahdi Aeinehvand, Edgar Ramírez Sánchez, Braulio Cárdenas Benítez, Sergio Omar Martínez-Chapa

    Centrifugal microfluidic platforms employ pseudo forces controlled by a spindle motor to automate bioanalytical assays on a single fluidic disc with no need for several syringe pumps [1]. Recently, we employed a portable cutter-plotter to fabricate microfluidic discs with active valves at point of need [2]. To address a healthcare issue of global interest, we developed a microfluidic disc to automate a sTREM-1 immunoassay for the detection of sepsis at late stages of the disease. To enable sepsis detection and monitoring at early stages, recently a gold iso-dielectric separation (GIDS) chip is develop that separates activated and non-activated leukocytes from blood serum [3]. However, the GIDS chip requires several syringe pumps and an off-chip manual step for sample preparation i.e., blood serum separation. As an alternative to GIDS, in this study we have developed 3D carbon IDS (CIDS) chips to reduce the cost of device fabrication. To prevent the need for the syringe pumps and external piping networks, we have integrated the CIDS on a microfluidic disc to automate the whole bioanalytical process from sample preparation to characterization of thousands of particles and cells. The main objective of developing the integrated microfluidic platform is the separation of activated and non-activated leukocytes for automated early sepsis detection at point of care (POC). However, as an early proof of the practicality of CIDS-on-disc, in this study we employed the hybrid centrifugal microfluidic system for separating various sizes of polystyrene microbeads as well as different bacteria. [1] M.M. Aeinehvand, F. Ibrahim, S.W. Harun, A. Kazemzadeh, H.A. Rothan, R. Yusof, M. Madou, Reversible thermo-pneumatic valves on centrifugal microfluidic platforms, Lab Chip. 15 (2015) 3358–3369. doi:10.1039/C5LC00634A. [2] M.M. Aeinehvand, P. Magaña, M.S. Aeinehvand, O. Aguilar, M.J. Madou, S.O. Martinez-Chapa, Ultra-rapid and low-cost fabrication of centrifugal microfluidic platforms with active mechanical valves, RSC Adv. 7 (2017) 55400–55407. doi:10.1039/C7RA11532F. [3] J.L. Prieto, H.-W. Su, H.W. Hou, M.P. Vera, B.D. Levy, R.M. Baron, J. Han, J. Voldman, Monitoring sepsis using electrical cell profiling, Lab Chip. 16 (2016) 4333–4340. doi:10.1039/C6LC00940A.


  • Open Access

    Ultra-rapid and low-cost fabrication of centrifugal microfluidic platforms with active mechanical valves

    by M. M. Aeinehvand, P. Magaña, M. S. Aeinehvand, O. Aguilar, M. J. Madou, S. O. Martinez-Chapa

    Onsite fabrication of centrifugal microfluidic cartridges is one way to provide laboratory and diagnostics platforms for extreme point-of-care (EPOC) settings. This paper presents a rapid fabrication process of centrifugal microfluidic cartridges (discs) using only a cutter plotter that is as low-cost, portable and rapid as conventional printers. Moreover, we devised an active valving mechanism to enable the development of complex sequential fluidic processes. The valves are engraved during disc manufacture itself by the cutter plotter. These embedded valves prevent the need for additional fabrication equipment and materials for the inserts that are usually required for other active valves. The valves are actuated by an external mechanical force, and are called active mechanical valves (M-valve). The M-valve is robust over a wide range of spinning speeds (e.g. up to 7000 rpm or 2470 rcf) and can be actuated manually, or automatically by a robotic arm. To demonstrate our approach, we developed two fluidic systems for immunoassay and chromatography. The first microfluidic platform was developed to automate a fluidic protocol usually required for immunoassays from whole blood. In this microfluidic disc, non-biological liquids were used to demonstrate the application of M-valves for robust control over retention and release of reagents. The chromatography microfluidic cartridge is a miniaturized experimental system for testing the capability of a modified resin (Sepharose 6B-PEG5000) for the isolation of monoPEGylated ribonuclease (RNase). The fabrication of microfluidic discs and M-valves by a simple cutter plotter is the fastest and least expensive method for the onsite development and onsite manufacturing of diagnostic kits for research and actual use even in EPOC settings.