JAJoshua M. Alexander

Joshua M. Alexander

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joshua M. Alexander has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Introduction to the special issue on perception and production of sounds in the high-frequency range of human speech

    by Ewa Jacewicz, Joshua M. Alexander, Robert A. Fox

    The frequency range audible to humans can extend from 20 Hz to 20 kHz, but only a portion of this range—the lower end up to 8 kHz—has been systematically explored because extended high-frequency (EHF) information above this low range has been considered unnecessary for speech comprehension. This special issue presents a collection of research studies exploring the presence of EHF information in the acoustic signal and its perceptual utility. The papers address the role of EHF hearing in auditory perception, the impact of EHF hearing loss on speech perception in specific populations and occupational settings, the importance of EHF in speech recognition and in providing speaker-related information, the utility of acoustic EHF energy in fricative sounds, and ultrasonic vocalizations in mice in relation to human hearing. Collectively, the research findings offer new insights and converge in showing that not only is EHF energy present in the speech spectrum, but listeners can utilize EHF cues in speech processing and recognition, and EHF hearing loss has detrimental effects on perception of speech and non-speech sounds. Together, this collection challenges the conventional notion that EHF information has minimal functional significance.


  • Open Access

    Hearing Aid Technology to Improve Speech Intelligibility in Noise

    by Joshua M. Alexander

    Understanding speech in noise is difficult for individuals with normal hearing and is even more so for individuals with hearing loss. Difficulty understanding speech in noise is one of the primary reasons people seek hearing assistance. Despite amplification, many hearing aid users still struggle to understand speech in noise. In response to this persistent problem, hearing aid manufacturers have invested significantly in developing new solutions. Any solution is not without its tradeoffs, and decisions must be made when optimizing and implementing them. Much of this happens behind the scenes, and casual observers fail to appreciate the nuances of developing new hearing aid technologies. The difficulty of communicating this information to clinicians may hinder the use or the fine-tuning of the various technologies available today. The purpose of this issue of Seminars in Hearing is to educate professionals and students in audiology, hearing science, and engineering about different approaches to combat problems related to environmental and wind noise using technologies that include classification, directional microphones, binaural signal processing, beamformers, motion sensors, and machine learning. To accomplish this purpose, some of the top researchers and engineers from the world's largest hearing aid manufacturers agreed to share their unique insights.


  • The peak height insertion gain (PHIG) method for quantifying acoustic feedback in hearing aids

    by Joshua M. Alexander, Stephanie Schmig, Randall P. Wagner, Steve Armstrong

    Hearing aids are commonly fit with ear canals partially or fully open—a condition that increases the risk of acoustic feedback. Feedback limits the audiometric fitting range of devices by limiting usable gain. To guide clinical decision making and device selection, we developed the Peak Height Insertion Gain (PHIG) method to detect feedback spikes in the short-term insertion gain derived from audio recordings. Using a manikin, 145 audio recordings of a speech signal were obtained from seven hearing aids. Each hearing aid was programmed for a moderate high-frequency hearing loss with systematic variations in frequency response, gain, and feedback suppression; this created audio recordings that varied the presence and strength of feedback. Using subjective ratings from 13 expert judges, the presence of feedback was determined and then classified according to its temporal and tonal qualities. These classifications were used to optimize parameters for two versions of the PHIG method based on global and local analyses. When specificity was fixed at 0.95, the sensitivity of the global analysis was 0.86 and increased to 0.95 when combined with the local analysis. Without compromising performance, a clinically expedient version of the PHIG method can be obtained using only a single measurement.

  • The relationship between ipsilateral cochlear gain reduction and speech-in-noise recognition at positive and negative signal-to-noise ratios

    by Kristina DeRoy Milvae, Joshua M. Alexander, Elizabeth A. Strickland

    Active mechanisms that regulate cochlear gain are hypothesized to influence speech-in-noise perception. However, evidence of a relationship between the amount of cochlear gain reduction and speech-in-noise recognition is mixed. Findings may conflict across studies because different signal-to-noise ratios (SNRs) were used to evaluate speech-in-noise recognition. Also, there is evidence that ipsilateral elicitation of cochlear gain reduction may be stronger than contralateral elicitation, yet, most studies have investigated the contralateral descending pathway. The hypothesis that the relationship between ipsilateral cochlear gain reduction and speech-in-noise recognition depends on the SNR was tested. A forward masking technique was used to quantify the ipsilateral cochlear gain reduction in 24 young adult listeners with normal hearing. Speech-in-noise recognition was measured with the PRESTO-R sentence test using speech-shaped noise presented at −3, 0, and +3 dB SNR. Interestingly, greater cochlear gain reduction was associated with lower speech-in-noise recognition, and the strength of this correlation increased as the SNR became more adverse. These findings support the hypothesis that the SNR influences the relationship between ipsilateral cochlear gain reduction and speech-in-noise recognition. Future studies investigating the relationship between cochlear gain reduction and speech-in-noise recognition should consider the SNR and both descending pathways.


  • The S-SH Confusion Test and the Effects of Frequency Lowering

    by Joshua M. Alexander

    Purpose: Frequency lowering in hearing aids can cause listeners to perceive [s] as [ʃ]. The S-SH Confusion Test, which consists of 66 minimal word pairs spoken by 6 female talkers, was designed to help clinicians and researchers document these negative side effects. This study's purpose was to use this new test to evaluate the hypothesis that these confusions will increase to the extent that low frequencies are altered. Method: Twenty-one listeners with normal hearing were each tested on 7 conditions. Three were control conditions that were low-pass filtered at 3.3, 5.0, and 9.1 kHz. Four conditions were processed with nonlinear frequency compression (NFC): 2 had a 3.3-kHz maximum audible output frequency (MAOF), with a start frequency (SF) of 1.6 or 2.2 kHz; 2 had a 5.0-kHz MAOF, with an SF of 1.6 or 4.0 kHz. Listeners' responses were analyzed using concepts from signal detection theory. Response times were also collected as a measure of cognitive processing. Results: Overall, [s] for [ʃ] confusions were minimal. As predicted, [ʃ] for [s] confusions increased for NFC conditions with a lower versus higher MAOF and with a lower versus higher SF. Response times for trials with correct [s] responses were shortest for the 9.1-kHz control and increased for the 5.0- and 3.3-kHz controls. NFC response times were also significantly longer as MAOF and SF decreased. The NFC condition with the highest MAOF and SF had statistically shorter response times than its control condition, indicating that, under some circumstances, NFC may ease cognitive processing. Conclusions: Large differences in the S-SH Confusion Test across frequency-lowering conditions show that it can be used to document a major negative side effect associated with frequency lowering. Smaller but significant differences in response times for correct [s] trials indicate that NFC can help or hinder cognitive processing, depending on its settings.


  • Acoustic and perceptual effects of amplitude and frequency compression on high-frequency speech

    by Joshua M. Alexander, Varsha Rallapalli

    This study investigated how six different amplification methods influence acoustic properties, and subsequently perception, of high-frequency cues in fricatives that have been processed with conventional full bandwidth amplification or nonlinear frequency compression (NFC)—12 conditions total. Amplification methods included linear gain, fast/slow-acting wide dynamic range compression crossed with fixed/individualized compression parameters, and a method with adaptive time constants. Twenty-one hearing-impaired listeners identified seven fricatives in nonsense syllables produced by female talkers. For NFC stimuli, frequency-compressed filters that precisely aligned 1/3-octave bands between input and output were used to quantify effective compression ratio, audibility, and temporal envelope modulation relative to the input. Results indicated significant relationships between these acoustic properties, each of which contributed significantly to fricative recognition across the entire corpus of stimuli. Recognition was significantly better for NFC stimuli compared with full bandwidth stimuli, regardless of the amplification method, which had complementary effects on audibility and envelope modulation. Furthermore, while there were significant differences in recognition across the amplification methods, they were not consistent across phonemes. Therefore, neither recognition nor acoustic data overwhelmingly suggest that one amplification method should be used over another for transmission of high-frequency cues in isolated syllables. Longer duration stimuli and more realistic listening conditions should be examined.


  • Power spectral entropy as an information-theoretic correlate of manner of articulation in American English

    by Fernando Llanos, Joshua M. Alexander, Christian E. Stilp, Keith R. Kluender

    While all languages differentiate speech sounds by manner of articulation, none of the acoustic correlates proposed to date seem to account for how these contrasts are encoded in the speech signal. The present study describes power spectral entropy (PSE), which quantifies the amount of potential information conveyed in the power spectrum of a given sound. Results of acoustic analyses of speech samples extracted from the Texas Instruments–Massachusetts Institute of Technology database reveal a statistically significant correspondence between PSE and American English major classes of manner of articulation. Thus, PSE accurately captures an acoustic correlate of manner of articulation in American English.


  • Open Access

    Masking Release in Children and Adults With Hearing Loss When Using Amplification

    by Marc Brennan, Ryan McCreery, Judy Kopun, Dawna Lewis, Joshua Alexander, Patricia Stelmachowicz

    Purpose: This study compared masking release for adults and children with normal hearing and hearing loss. For the participants with hearing loss, masking release using simulated hearing aid amplification with 2 different compression speeds (slow, fast) was compared. Method: Sentence recognition in unmodulated noise was compared with recognition in modulated noise (masking release). Recognition was measured for participants with hearing loss using individualized amplification via the hearing-aid simulator. Results: Adults with hearing loss showed greater masking release than the children with hearing loss. Average masking release was small (1 dB) and did not depend on hearing status. Masking release was comparable for slow and fast compression. Conclusions: The use of amplification in this study contrasts with previous studies that did not use amplification. The results suggest that when differences in audibility are reduced, participants with hearing loss may be able to take advantage of dips in the noise levels, similar to participants with normal hearing. Although children required a more favorable signal-to-noise ratio than adults for both unmodulated and modulated noise, masking release was not statistically different. However, the ability to detect a difference may have been limited by the small amount of masking release observed.


  • Spectral contrast effects in vowel categorization by listeners with sensorineural hearing loss

    by Christian E. Stilp, Joshua M. Alexander

    The auditory system is highly sensitive to changes in acoustic input. This is especially true for sounds with relatively stable (reliable) spectral properties across time. Over a limited range, changes to the spectrum (e.g., spectral peak location upon introduction of a new sound) are perceptually enhanced in proportion to the property's long-term reliability, producing spectral contrast effects (SCEs). For example, a neutral vowel between /i/-/ε/ is more likely to be labelled /ε/ (high-F1) when preceded by sounds with a reliable low-frequency peak in the F1 range for /i/, and vice versa. Yet, it is unknown how SCEs affect speech perception by hearing-impaired (HI) listeners because research has only examined normal-hearing (NH) listeners. Here, listeners with mild-to-moderate HI identified target vowels varying from /i/-/ε/ that followed a precursor sentence. Reliability of precursor spectral peaks was manipulated using low-F1 or high-F1 bandpass filters with +5 to +20 dB gain. SCE magnitude was proportional to precursor filter gain (like NH listeners), and surprisingly, to the amount of low-frequency hearing loss. Thus, mechanisms responsible for SCEs are not dependent on healthy hearing, and are magnified by auditory filter broadening associated with sensorineural hearing loss. Implications of these findings for speech perception will be discussed.