AMAlireza Mosavar

Alireza Mosavar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alireza Mosavar has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Mahmoud Kadkhodaei

    Department of Mechanical Engineering, Isfahan University of Technology, Isfahan, Iran

    2 shared publications
  • Alireza Ziaei

    1 shared publication
  • Mohammad Reza Effatparvar

    Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran

    1 shared publication
  • Monireh Nili

    Department of Prosthodontics, School of Dentistry, Isfahan (Khorasgan) Branch, Islamic Azad University, Isfahan, Iran

    1 shared publication
  • Nima Jamshidi

    Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran

    1 shared publication
  • Sayed Raouf Hashemi

    Department of Prosthodontics, Faculty of Dentistry, Islamic Azad University Isfahan (Khorasgan) Branch, Isfahan, Iran

    1 shared publication

Latest Publications

  • Open Access

    Appraising efficiency of OpSite as coolant in drilling of bone

    by Mohammad Reza Effatparvar, Nima Jamshidi, Alireza Mosavar

    Background: During drilling of bone, which is common in clinical surgeries, heat generation increases local temperature in the drilling site. Transmission of excessive heat to the surrounding bone tissue can cause thermal osteonecrosis. Consequently, it may lead to failure of implants and fixation screws or delay in healing process. Using cooling is a method for limiting temperature elevation. Materials and methods: In this study, through comparing three conditions of drilling without cooling, external cooling with normal saline, and external cooling with OpSite spray, the efficiency of OpSite as coolant is studied. In this regard, 2 drill bit diameters, 3 drilling speeds, and 3 drilling feed-rates are considered as drilling variables in the experiments. Results: For the whole experiments, while cooling with normal saline resulted in lower maximum temperatures than without cooling condition, OpSite had even better results and limited the temperature elevation during drilling of bone efficiently. Conclusion: OpSite spray, which has lower infection risks than normal saline on one hand and lower maximum temperature rise with all combinations of drilling parameters on the other hand, can be considered in clinical surgeries for cooling applications.


  • A Comparative Analysis on Two Types of Oral Implants, Bone‐Level and Tissue‐Level, with Different Cantilever Lengths of Fixed Prosthesis

    by Alireza Mosavar, Monireh Nili, Sayed Raouf Hashemi, Mahmoud Kadkhodaei

    Purpose: Depending on esthetic, anatomical, and functional aspects, in implant‐prosthetic restoration of a completely edentulous jaw, the selection of implant type is highly important; however, bone‐ and tissue‐level implants and their stress distribution in bone have not yet been comparatively investigated. Hence, finite element analysis was used to study the influence of cantilever length in a fixed prosthesis on stress distribution in peri‐implant bone around these two types of oral implants.Materials and Methods: A 3D edentulous mandible was modeled. In simulations, a framework with four posterior cantilever lengths and two types of implants, bone‐level and tissue‐level, was considered. A compressive load was applied to the distal regions of the cantilevers, and the von‐Mises stress of peri‐implant bone was investigated. The independent t‐test and the Pearson correlation coefficient analyzed the results (α = 0.05).Results: Stresses in the cortical bone around the bone‐level implants were greater than those in the tissue‐level implants with the same cantilever length. In addition, by extending the cantilever length, the stress values in peri‐implant bone increased. Therefore, when the cantilever was at its maximum length, the maximum stress was in cortical bone and around the bone‐level distal implants.Conclusion: The results of the present study indicate that treatment with tissue‐level implants is potentially more advantageous than with bone‐level implants for implant‐supported fixed prostheses.


  • The Effect of Implant Thread Design on Stress Distribution in Anisotropic Bone with Different Osseointegration Conditions: A Finite Element Analysis

    by Alireza Mosavar, Alireza Ziaei, Mahmoud Kadkhodaei

    Alireza Mosavar, BSc/Alireza Ziaei, BSc/Mahmoud Kadkhodaei, PhD: Purpose: Whereas bone is anisotropic, nearly all previous mechanical analyses of implants assumed bone as an isotropic material. Another means to simplify a simulation of the biomechanics of the implant-bone interface is the assumption of complete or no osseointegration; in clinical reality, an implant never achieves 100% contact with the surrounding bone. This study evaluated different thread profiles while not taking into account these two common simplifications. This study sought to (1) investigate the effects of various implant thread designs on stress distribution in the peri-implant bone, (2) appraise previous efforts in this area, and (3) find an optimum basic thread-form design. Materials and Methods: Through finite element analysis, four different basic commercial thread-form configurations for a solid screw-type implant were modeled: buttress, reverse buttress, V, and square. Bone was assumed to be transversely isotropic, and various degrees of osseointegration were simulated. Results: Simulations showed that von Mises stresses were more distributed in the mesiodistal direction. Additionally, maximum stresses were concentrated at the cervical cortical bone region and the first thread. Moreover, in most of the models, von Mises stresses gradually increased in the supporting structure when the degree of osseointegration increased. Conclusion: The use of different thread designs and various osseointegration conditions did not affect the stress distribution patterns in the supporting bone. In this study, square threads showed the most favorable results according to the predicted values of von Mises equivalent stress, pressure, different shear stresses, and micromotion.