Salman Al-Zahrani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Salman Al-Zahrani has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Mohammad Saidul Islam
School of Mechanical and Mechatronic Engineering, University of Technology Sydney, Ultimo, NSW 2007, Australia
6 shared publications Suvash C. Saha
4 shared publications- Suvash Chandra Saha
School of Mechanical and Mechatronic Engineering, Faculty of Engineering and Information Technology, University of Technology Sydney, Ultimo, NSW 2007, Australia
2 shared publications Feng Xu
1 shared publication
Latest Publications
- Open Access
- 19 November 2026
- Published by MDPI AG in Mathematics
- Vol. 14 (22) , 4256
A Systematic Investigation of the Effect of Port Diameter on the Thermal Performance of a Corrugated Plate Heat Exchanger
The exceptional thermal performance of corrugated plate heat exchangers (CPHEs) is generally accompanied by substantial pumping power requirements. A systematic parametric assessment is essential to determine favorable CPHE configurations. Therefore, this study aims to systematically investigate the effect of the port diameter (Dp) on the thermal and hydraulic characteristics of CPHEs. Four CPHEs with Dp = 30 mm (CPHE30), Dp = 45 mm (CPHE45), Dp = 60 mm (CPHE60), and Dp = 75 mm (CPHE75) are investigated. A validated CFD methodology is employed to systematically evaluate the thermal–hydraulic response of the investigated configurations. The ratio of the heat transfer rate to the pumping power is employed as the overall thermal performance indicator (η). The results show that CPHE30 yields the highest data of the Nusselt number (Nu). Yet, the differences in Nu among the investigated port diameters are negligible. Both core and port pressure losses decrease with an increasing Dp. The port pressure drop for CPHE30 is 9–11% and 12–18% higher than that for CPHE45 and CPHE60, respectively. Overall, based on the present study, a port diameter of at least 80% of the maximum feasible diameter is recommended. Accordingly, the η values of CPHE60 are 14.7 to 20.7 and 3.7 to 6.6% greater than those of CPHE30 and CPHE45, respectively.
- 19 November 2026
- Published by MDPI AG in Mathematics
- Vol. 14 (22) , 4256
Open AccessA Systematic Investigation of the Effect of Port Diameter on the Thermal Performance of a Corrugated Plate Heat Exchanger
The exceptional thermal performance of corrugated plate heat exchangers (CPHEs) is generally accompanied by substantial pumping power requirements. A systematic parametric assessment is essential to determine favorable CPHE configurations. Therefore, this study aims to systematically investigate the effect of the port diameter (Dp) on the thermal and hydraulic characteristics of CPHEs. Four CPHEs with Dp = 30 mm (CPHE30), Dp = 45 mm (CPHE45), Dp = 60 mm (CPHE60), and Dp = 75 mm (CPHE75) are investigated. A validated CFD methodology is employed to systematically evaluate the thermal–hydraulic response of the investigated configurations. The ratio of the heat transfer rate to the pumping power is employed as the overall thermal performance indicator (η). The results show that CPHE30 yields the highest data of the Nusselt number (Nu). Yet, the differences in Nu among the investigated port diameters are negligible. Both core and port pressure losses decrease with an increasing Dp. The port pressure drop for CPHE30 is 9–11% and 12–18% higher than that for CPHE45 and CPHE60, respectively. Overall, based on the present study, a port diameter of at least 80% of the maximum feasible diameter is recommended. Accordingly, the η values of CPHE60 are 14.7 to 20.7 and 3.7 to 6.6% greater than those of CPHE30 and CPHE45, respectively.
- Open Access
- 19 August 2026
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 78
Variable-depth corrugation approach for efficient plate heat exchangers
- 19 August 2026
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 78
Open AccessVariable-depth corrugation approach for efficient plate heat exchangers
- 21 November 2025
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 227
Plate heat exchanger: A state-of-the-art review
- 21 November 2025
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 227
Plate heat exchanger: A state-of-the-art review
- Open Access
- 5 August 2024
- Published by Manarah in Frontiers in Engineering and Built Environment
- Vol. 4 (ahead-of-p)
Thermal performance comparison of vertical and diagonal flow configurations in corrugated plate heat exchanger
The purpose of this study is to compare the thermal performance of two flow configurations in corrugated plate heat exchanger (CPHE): vertical flow configuration (CPHEvert.) and diagonal flow configuration (CPHEdiag.). The study aims to determine the differences between these configurations and evaluate their respective thermal performance based on metrics such as heat transfer rates, pressure drop values and flow distribution. The study compares the thermal performance of two flow arrangements of CPHE using identical geometrical dimensions and test conditions. Computational fluid dynamics (CFD) is employed, and a validated numerical model is used for the investigation. The comparison is based on analyzing the rate of heat transfer and pressure drop data between the two flow arrangements. The findings indicate that the diagonal flow configuration in CPHEs offers improved flow distribution, enhanced heat transfer performance and lower pressure drop compared to the vertical flow configuration. However, the differences in general in the thermal performance of CPHEvert. and CPHEdiag. are found to be minimal. To the best of the author’s knowledge, this study represents the first attempt to investigate the impact of vertical and diagonal flow configurations on the thermal performance of the CPHE.
- 5 August 2024
- Published by Manarah in Frontiers in Engineering and Built Environment
- Vol. 4 (ahead-of-p)
Open AccessThermal performance comparison of vertical and diagonal flow configurations in corrugated plate heat exchanger
The purpose of this study is to compare the thermal performance of two flow configurations in corrugated plate heat exchanger (CPHE): vertical flow configuration (CPHEvert.) and diagonal flow configuration (CPHEdiag.). The study aims to determine the differences between these configurations and evaluate their respective thermal performance based on metrics such as heat transfer rates, pressure drop values and flow distribution. The study compares the thermal performance of two flow arrangements of CPHE using identical geometrical dimensions and test conditions. Computational fluid dynamics (CFD) is employed, and a validated numerical model is used for the investigation. The comparison is based on analyzing the rate of heat transfer and pressure drop data between the two flow arrangements. The findings indicate that the diagonal flow configuration in CPHEs offers improved flow distribution, enhanced heat transfer performance and lower pressure drop compared to the vertical flow configuration. However, the differences in general in the thermal performance of CPHEvert. and CPHEdiag. are found to be minimal. To the best of the author’s knowledge, this study represents the first attempt to investigate the impact of vertical and diagonal flow configurations on the thermal performance of the CPHE.
- 31 March 2023
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 59 (9) , 1661-1675
Heat transfer characteristics of innovative configurations of double pipe heat exchanger
Saving energy resources requires a continuous improvement of the power equipment. The present study aims to develop new designs of double pipe heat exchanger (DPHE) to improve the heating/cooling processes at the lowest possible pumping power. Therefore, thermal performance investigation of three configurations of DPHE has been carried out. These configurations are circular wavy DPHE (DPHEwavy), plain oval DPHE (DPHEov.), and an oval wavy DPHE (DPHEov.wavy). In addition, the conventional DPHE (DPHEconv.) has been employed as a reference heat exchanger, and a validated CFD approach is adopted to perform the current investigation. The findings reveal that, DPHEov.wavy yields the highest Nusselt number (Nu) which is up to 28% with respect to DPHEconv.. In addition, data of pressure drop (ΔP) of DPHEwavy are found the highest followed by those of DPHEconv., whereas DPHEov. is found to yield the lowest ΔP. Furthermore, thermal performance factor (\(\eta\)) has been considered, and DPHEov. is found to own the highest \(\eta\) of all investigated DPHEs. In conclusion, the oval tubes have shown better heat transfer characteristics with respect to their circular counterparts in general, in particular plain oval DPHE. Graphical abstract- 31 March 2023
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 59 (9) , 1661-1675
Heat transfer characteristics of innovative configurations of double pipe heat exchanger
Saving energy resources requires a continuous improvement of the power equipment. The present study aims to develop new designs of double pipe heat exchanger (DPHE) to improve the heating/cooling processes at the lowest possible pumping power. Therefore, thermal performance investigation of three configurations of DPHE has been carried out. These configurations are circular wavy DPHE (DPHEwavy), plain oval DPHE (DPHEov.), and an oval wavy DPHE (DPHEov.wavy). In addition, the conventional DPHE (DPHEconv.) has been employed as a reference heat exchanger, and a validated CFD approach is adopted to perform the current investigation. The findings reveal that, DPHEov.wavy yields the highest Nusselt number (Nu) which is up to 28% with respect to DPHEconv.. In addition, data of pressure drop (ΔP) of DPHEwavy are found the highest followed by those of DPHEconv., whereas DPHEov. is found to yield the lowest ΔP. Furthermore, thermal performance factor (\(\eta\)) has been considered, and DPHEov. is found to own the highest \(\eta\) of all investigated DPHEs. In conclusion, the oval tubes have shown better heat transfer characteristics with respect to their circular counterparts in general, in particular plain oval DPHE. Graphical abstract- 1 March 2021
- Published by Elsevier in Applied Thermal Engineering
- Vol. 186
Heat transfer enhancement of modified flat plate heat exchanger
- 1 March 2021
- Published by Elsevier in Applied Thermal Engineering
- Vol. 186
Heat transfer enhancement of modified flat plate heat exchanger
- 1 March 2021
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 161
Heat transfer enhancement investigation in a novel flat plate heat exchanger
- 1 March 2021
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 161
Heat transfer enhancement investigation in a novel flat plate heat exchanger
- 1 November 2020
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 161
Heat transfer augmentation in retrofitted corrugated plate heat exchanger
- 1 November 2020
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 161
Heat transfer augmentation in retrofitted corrugated plate heat exchanger