Eitan Melamed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Eitan Melamed has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Jared M. Gopman
Icahn School of Medicine at Mount Sinai Hospital
2 shared publications- Amanda R. Walsh
Division of Plastic and Reconstructive Surgery, Icahn School of Medicine at Mount Sinai, 79-01 Broadway, Elmhurst, New York, 11373, USA
1 shared publication - Antonio Carlos da Costa
Orthopaedic and Traumatology Surgery Department ‐ Santa Casa de Sao Paulo Hand Surgery and Microsurgery Group Sao Paulo Brazil
1 shared publication Aviram M. M.D. Giladi
The Curtis National Hand Center, MedStar Union Memorial Hospital
1 shared publicationBin Hu
Hard Tissue Research Unit, Department of Molecular Pathobiology, New York University College of Dentistry, New York, N.Y.
1 shared publicationBosung N. M.S. Titanji
The Curtis National Hand Center, MedStar Union Memorial Hospital
1 shared publication
Latest Publications
- 22 September 2026
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
Letter to the Editor: The Forward Movement: Amplifying Black Voices on Race and Orthopaedics—The Hidden Organizational Tax of Bias
Was not provided for this article.
- 22 September 2026
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
Letter to the Editor: The Forward Movement: Amplifying Black Voices on Race and Orthopaedics—The Hidden Organizational Tax of Bias
Was not provided for this article.
- 2 December 2024
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 44 (1) , 102047
Safety of dorsal screw penetration at the proximal holes of volar locking plates
- 2 December 2024
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 44 (1) , 102047
Safety of dorsal screw penetration at the proximal holes of volar locking plates
- 7 February 2023
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 42 (2) , 103-108
Neuroma-in-continuity: a review of pathophysiology and approach to the affected patient
- 7 February 2023
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 42 (2) , 103-108
Neuroma-in-continuity: a review of pathophysiology and approach to the affected patient
- 11 October 2022
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 151 (1) , 99e-104e
Targeted Muscle Reinnervation for Treatment of Postresection Interdigital Neuroma: A Cadaveric Feasibility Study
Background: Symptomatic postresection interdigital neuroma is a frustrating problem that causes debilitating foot pain. Implementing the concepts of targeted muscle innervation, this study offers a novel nerve transfer involving the resected third common plantar digital nerve (CPDN) to the motor nerve branch of the third dorsal interosseous muscle (DIMB) to improve postresection pain. Methods: Ten fresh feet from seven cadaveric donors were used for this study. CPDN and DIMB lengths and diameters were measured, along with nerve overlap after the transfer with ankle in neutral position and in maximal dorsiflexion. Motor entry point to the calcaneal tuberosity and to the fifth metatarsal tuberosity were measured and used to evaluate the ratio relative to foot length. Means, standard deviations, and P values were calculated for each measure and between sexes and feet (right and left). Results: In all specimens, the nerve transfer was technically feasible, without notable size mismatch between the donor and recipient nerves. CPDN, DIMB, and important anatomical reference points were identifiable in all specimens. Average CPDN length was 30.1 ± 8.2 mm. The average DIMB length was 14.4 ± 3.9 mm. The overlap between the donor and recipient in neutral ankle position at the transfer site was 6.4 ± 1.8 mm. Conclusions: Given their anatomical locations, a nerve transfer between the third CPDN and third DIMB is surgically feasible. This novel technique is a viable option that can be used instead of the conventional technique of muscle implantation or more proximal re-resection for symptomatic postresection interdigital neuroma.
- 11 October 2022
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 151 (1) , 99e-104e
Targeted Muscle Reinnervation for Treatment of Postresection Interdigital Neuroma: A Cadaveric Feasibility Study
Background: Symptomatic postresection interdigital neuroma is a frustrating problem that causes debilitating foot pain. Implementing the concepts of targeted muscle innervation, this study offers a novel nerve transfer involving the resected third common plantar digital nerve (CPDN) to the motor nerve branch of the third dorsal interosseous muscle (DIMB) to improve postresection pain. Methods: Ten fresh feet from seven cadaveric donors were used for this study. CPDN and DIMB lengths and diameters were measured, along with nerve overlap after the transfer with ankle in neutral position and in maximal dorsiflexion. Motor entry point to the calcaneal tuberosity and to the fifth metatarsal tuberosity were measured and used to evaluate the ratio relative to foot length. Means, standard deviations, and P values were calculated for each measure and between sexes and feet (right and left). Results: In all specimens, the nerve transfer was technically feasible, without notable size mismatch between the donor and recipient nerves. CPDN, DIMB, and important anatomical reference points were identifiable in all specimens. Average CPDN length was 30.1 ± 8.2 mm. The average DIMB length was 14.4 ± 3.9 mm. The overlap between the donor and recipient in neutral ankle position at the transfer site was 6.4 ± 1.8 mm. Conclusions: Given their anatomical locations, a nerve transfer between the third CPDN and third DIMB is surgically feasible. This novel technique is a viable option that can be used instead of the conventional technique of muscle implantation or more proximal re-resection for symptomatic postresection interdigital neuroma.
- 16 November 2021
- Published by Springer Nature
- p. 381-408
Nerve Injury After Open and Arthroscopic Surgery of the Ankle and Foot, Including Morton Neuroma
- 16 November 2021
- Published by Springer Nature
- p. 381-408
Nerve Injury After Open and Arthroscopic Surgery of the Ankle and Foot, Including Morton Neuroma
- Open Access
- 10 May 2021
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 9 (5) , e3566
The Cutting Edge: Surface Texture Analysis following Resection of Nerve Stumps Using Various Instruments
Background: Preparation of nerve ends is an essential part of nerve repair surgery. Multiple instruments have been described for this purpose; however, no consensus exists regarding which is the least traumatic for tissue handling. We believe that various instruments used for nerve-end excision will lead to different surface roughness. Methods: Median and ulnar nerves from fresh frozen cadavers were dissected, and 1–2 cm lengths were excised using a No. 11 blade, a razor blade, or a pair of scissors. Using electron microscopy, 3-dimensional surface analysis of roughness (Sa) for each specimen was performed using ZeeScan optical hardware and GetPhase software (PhaseView, Buisson, France). An ANOVA or Kruskal-Wallis test compared roughness measures among cutting techniques. Results: Forty nerves were included. Of these, 13 (32.5%) were cut using scissors, 15 (37.5%) using a razor blade, and 12 (30%) using a No. 11 blade. An ANOVA test showed statistical differences in Sa among the cutting techniques (P = 0.002), with the lowest mean Sa noted in the scissors group (7.2 µM, 95% CI: 5.34–9.06), followed by No. 11 blade (7.29 µM, 95% CI: 5.22–9.35), and razor blade (11.03 µM, 95% CI: 9.43–12.62). Median Ra (surface profile roughness) was 4.58 (IQR: 2.62–5.46). A Kruskal-Wallis test demonstrated statistical difference in Ra among techniques (P = 0.003), with the lowest by No. 11 blade (3 µM, IQR: 1.87–4.38), followed by scissors (3.29 µM, IQR: 1.56–4.96), and razor (5.41 µM, IQR: 4.95–6.21). Conclusion: This novel technique of 3-dimensional surface analysis found razor blade use demonstrated poor roughness, whereas a No. 11 blade or nerve-specific scissors led to equivocally smooth nerve ends.
- 10 May 2021
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 9 (5) , e3566
Open AccessThe Cutting Edge: Surface Texture Analysis following Resection of Nerve Stumps Using Various Instruments
Background: Preparation of nerve ends is an essential part of nerve repair surgery. Multiple instruments have been described for this purpose; however, no consensus exists regarding which is the least traumatic for tissue handling. We believe that various instruments used for nerve-end excision will lead to different surface roughness. Methods: Median and ulnar nerves from fresh frozen cadavers were dissected, and 1–2 cm lengths were excised using a No. 11 blade, a razor blade, or a pair of scissors. Using electron microscopy, 3-dimensional surface analysis of roughness (Sa) for each specimen was performed using ZeeScan optical hardware and GetPhase software (PhaseView, Buisson, France). An ANOVA or Kruskal-Wallis test compared roughness measures among cutting techniques. Results: Forty nerves were included. Of these, 13 (32.5%) were cut using scissors, 15 (37.5%) using a razor blade, and 12 (30%) using a No. 11 blade. An ANOVA test showed statistical differences in Sa among the cutting techniques (P = 0.002), with the lowest mean Sa noted in the scissors group (7.2 µM, 95% CI: 5.34–9.06), followed by No. 11 blade (7.29 µM, 95% CI: 5.22–9.35), and razor blade (11.03 µM, 95% CI: 9.43–12.62). Median Ra (surface profile roughness) was 4.58 (IQR: 2.62–5.46). A Kruskal-Wallis test demonstrated statistical difference in Ra among techniques (P = 0.003), with the lowest by No. 11 blade (3 µM, IQR: 1.87–4.38), followed by scissors (3.29 µM, IQR: 1.56–4.96), and razor (5.41 µM, IQR: 4.95–6.21). Conclusion: This novel technique of 3-dimensional surface analysis found razor blade use demonstrated poor roughness, whereas a No. 11 blade or nerve-specific scissors led to equivocally smooth nerve ends.