Davor Brinc
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Davor Brinc has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Ashley Di Meo
Department of Laboratory Medicine & Pathobiology, University of Toronto, Toronto, Ontario, Canada
1 shared publication- Camelia Capraru
Viral Hepatitis Care Network (VIRCAN) Study Group, Toronto Centre for Liver Disease, Toronto, ON M5G 2C, Canada
1 shared publication - Daniel Li
Institute of Medical Science, University of Toronto, Toronto, Canada
1 shared publication - David Smookler
Toronto Centre for Liver Disease, University Health Network, Toronto, ON M5G 2C4, Canada
1 shared publication - Heng Sun
Department of Clinical Biochemistry, University Health Network, Toronto, ON M5G 2C4, Canada
1 shared publication - Jordan J. Feld
Toronto Centre for Liver Disease, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada
1 shared publication
Latest Publications
- 4 April 2022
- Published by Elsevier in Clinica Chimica Acta
- Vol. 531, 230-236
Evaluation of a batched-extraction method for measurement of sirolimus, tacrolimus, and cyclosporine on the Architect i2000SR
- 4 April 2022
- Published by Elsevier in Clinica Chimica Acta
- Vol. 531, 230-236
Evaluation of a batched-extraction method for measurement of sirolimus, tacrolimus, and cyclosporine on the Architect i2000SR
- Open Access
Evaluation of Dried Blood Spot Testing for SARS-CoV-2 Serology Using a Quantitative Commercial Assay
Dried blood spots (DBS) are commonly used for serologic testing for viruses and provide an alternative collection method when phlebotomy and/or conventional laboratory testing are not readily available. DBS collection could be used to facilitate widespread testing for SARS-CoV-2 antibodies to document past infection, vaccination, and potentially immunity. We investigated the characteristics of Roche’s Anti-SARS-CoV-2 (S) assay, a quantitative commercial assay for antibodies against the spike glycoprotein. Antibody levels were reduced relative to plasma following elution from DBS. Quantitative results from DBS samples were highly correlated with values from plasma (r2 = 0.98), allowing for extrapolation using DBS results to accurately estimate plasma antibody levels. High concordance between plasma and fingerpick DBS was observed in PCR-confirmed COVID-19 patients tested 90 days or more after the diagnosis (45/46 matched; 1/46 mismatched plasma vs. DBS). The assessment of antibody responses to SARS-CoV-2 using DBS may be feasible using a quantitative anti-S assay, although false negatives may rarely occur in those with very low antibody levels.
Open AccessEvaluation of Dried Blood Spot Testing for SARS-CoV-2 Serology Using a Quantitative Commercial Assay
Dried blood spots (DBS) are commonly used for serologic testing for viruses and provide an alternative collection method when phlebotomy and/or conventional laboratory testing are not readily available. DBS collection could be used to facilitate widespread testing for SARS-CoV-2 antibodies to document past infection, vaccination, and potentially immunity. We investigated the characteristics of Roche’s Anti-SARS-CoV-2 (S) assay, a quantitative commercial assay for antibodies against the spike glycoprotein. Antibody levels were reduced relative to plasma following elution from DBS. Quantitative results from DBS samples were highly correlated with values from plasma (r2 = 0.98), allowing for extrapolation using DBS results to accurately estimate plasma antibody levels. High concordance between plasma and fingerpick DBS was observed in PCR-confirmed COVID-19 patients tested 90 days or more after the diagnosis (45/46 matched; 1/46 mismatched plasma vs. DBS). The assessment of antibody responses to SARS-CoV-2 using DBS may be feasible using a quantitative anti-S assay, although false negatives may rarely occur in those with very low antibody levels.
- 23 March 2021
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 6 (5) , 1251-1263
Optimizing Measurement and Interpretation of the G6PD/Hb Ratio
Background Glucose-6-phosphate dehydrogenase (G6PD)/hemoglobin (Hb) ratio helps detect G6PD deficiency, an X-linked disorder that can be asymptomatic or cause acute hemolytic anemia and chronic hemolysis. We investigated preanalytical, analytical, and postanalytical aspects to optimize G6PD/Hb measurement and interpretation. Methods G6PD was measured with the Pointe Scientific assay and Hb with Drabkin’s reagent on Alinity c® (Abbott Diagnostics). Stability of G6PD/Hb was assessed after 7 and 14 days while stored at 2–8 °C. Stability of hemolysate prepared for G6PD analysis was assessed using QC and patient samples up to 4 h at room temperature or 2–8 °C. Analytical performance specifications including precision, method comparison, linearity, LOQ, and carry-over were established for the enzymatic reaction of G6PD and spectrophotometric reading of Hb. G6PD/Hb reference interval and cut-offs were established indirectly using truncated maximum likelihood method (TML) using retrospective data (n = 4715 patient data points). Results Samples were stable after 7 days at 2–8°C, unless grossly hemolyzed. Hemolysate prepared for G6PD measurement remained stable for up to 4 h for QC at room temperature and 2–8°C, but up to 30 min–1 h at room temperature and 1–2 h at 2–8 °C for patient samples. Precision, linearity, LOQ, and carryover were acceptable. G6PD/Hb cut-offs were <3.3, ≥3.3, 3.3–8.9, and ≥8.9 U/g Hb for deficient males/females, normal males, intermediate females, and normal females, respectively. Conclusions In vitro hemolysis and delayed hemolysate analysis significantly reduce G6PD/Hb stability. QC material cannot detect the impact of delayed hemolysate analysis. These findings were foundational for optimizing G6PD/Hb protocols for a new platform and establishing laboratory-specific G6PD/Hb cut-offs.
- 23 March 2021
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 6 (5) , 1251-1263
Optimizing Measurement and Interpretation of the G6PD/Hb Ratio
Background Glucose-6-phosphate dehydrogenase (G6PD)/hemoglobin (Hb) ratio helps detect G6PD deficiency, an X-linked disorder that can be asymptomatic or cause acute hemolytic anemia and chronic hemolysis. We investigated preanalytical, analytical, and postanalytical aspects to optimize G6PD/Hb measurement and interpretation. Methods G6PD was measured with the Pointe Scientific assay and Hb with Drabkin’s reagent on Alinity c® (Abbott Diagnostics). Stability of G6PD/Hb was assessed after 7 and 14 days while stored at 2–8 °C. Stability of hemolysate prepared for G6PD analysis was assessed using QC and patient samples up to 4 h at room temperature or 2–8 °C. Analytical performance specifications including precision, method comparison, linearity, LOQ, and carry-over were established for the enzymatic reaction of G6PD and spectrophotometric reading of Hb. G6PD/Hb reference interval and cut-offs were established indirectly using truncated maximum likelihood method (TML) using retrospective data (n = 4715 patient data points). Results Samples were stable after 7 days at 2–8°C, unless grossly hemolyzed. Hemolysate prepared for G6PD measurement remained stable for up to 4 h for QC at room temperature and 2–8°C, but up to 30 min–1 h at room temperature and 1–2 h at 2–8 °C for patient samples. Precision, linearity, LOQ, and carryover were acceptable. G6PD/Hb cut-offs were <3.3, ≥3.3, 3.3–8.9, and ≥8.9 U/g Hb for deficient males/females, normal males, intermediate females, and normal females, respectively. Conclusions In vitro hemolysis and delayed hemolysate analysis significantly reduce G6PD/Hb stability. QC material cannot detect the impact of delayed hemolysate analysis. These findings were foundational for optimizing G6PD/Hb protocols for a new platform and establishing laboratory-specific G6PD/Hb cut-offs.