Robert W. de Gille
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Robert W. de Gille has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- David Allan Simpson
University of Melbourne
4 shared publications - Jean-Philippe Tetienne
RMIT University
3 shared publications - Lloyd C. L. Hollenberg
University of Melbourne
3 shared publications - Erich Pascal Malkemper
Max Planck Institute for Neurobiology of Behavior – caesar, Bonn, Germany
2 shared publications - Julia M. McCoey
School of Physics The University of Melbourne Parkville VIC 3010 Australia
2 shared publications - Liam T. Hall
CSIRO Manufacturing, Clayton, Victoria 3168, Australia
2 shared publications
Latest Publications
- 17 July 2024
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 11 (9) , 3486-3491
High Efficiency Triple-Helix Solenoid Beam Generated by Dielectric Metasurface
- 17 July 2024
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 11 (9) , 3486-3491
High Efficiency Triple-Helix Solenoid Beam Generated by Dielectric Metasurface
- 16 January 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (3) , 032404
Temperature and angle dependent magnetic imaging of biological iron nanoparticles using quantum diamond microscopy
Quantum diamond microscopy is an emerging versatile technique for studying the magnetic properties of materials. It has been applied extensively in condensed matter physics and materials science and has blossomed into a unique platform for the magnetic study of biological systems. To date, biological demonstrations of quantum diamond microscopy have been performed under ambient conditions. Here, we extend this magnetic microscopy platform to cryogenic temperatures to study magnetic anisotropy and the blocking temperature from an individual iron organelle found within the inner ear of pigeons. Our work confirms that the interface between thin histological tissue sections and diamond can be maintained under cryogenic temperatures. Our magnetic images provide evidence of magnetic anisotropy from a single iron organelle with sub-cellular resolution using this correlative optical imaging method. This approach may be extended to a broad range of systems where magnetic materials play structural and functional roles in biological systems.
- 16 January 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (3) , 032404
Temperature and angle dependent magnetic imaging of biological iron nanoparticles using quantum diamond microscopy
Quantum diamond microscopy is an emerging versatile technique for studying the magnetic properties of materials. It has been applied extensively in condensed matter physics and materials science and has blossomed into a unique platform for the magnetic study of biological systems. To date, biological demonstrations of quantum diamond microscopy have been performed under ambient conditions. Here, we extend this magnetic microscopy platform to cryogenic temperatures to study magnetic anisotropy and the blocking temperature from an individual iron organelle found within the inner ear of pigeons. Our work confirms that the interface between thin histological tissue sections and diamond can be maintained under cryogenic temperatures. Our magnetic images provide evidence of magnetic anisotropy from a single iron organelle with sub-cellular resolution using this correlative optical imaging method. This approach may be extended to a broad range of systems where magnetic materials play structural and functional roles in biological systems.
- Open Access
- 15 November 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (47)
Quantum magnetic imaging of iron organelles within the pigeon cochlea
Significance: Cuticulosomes are subcellular structures located within the inner ear hair cells of a variety of avian species with potential relevance to magnetoreception. Here we apply quantum magnetic microscopy to image the magnetic properties of individual iron cuticulosomes within tissue samples. The magnetic susceptibility of the cuticulosomes was determined by characterizing the stray magnetic field strength as a function of applied magnetic field in two distinct locations of the pigeon inner ear. The measured susceptibilities do not support the particle model of magnetoreception, suggesting the physiological relevance of cuticulosomes lies in iron storage or stabilization of stereocilia. The quantum magnetic imaging method can be applied across a variety of biological systems providing an effective tool to screen for magnetic particle–based magnetoreceptors.
- 15 November 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (47)
Open AccessQuantum magnetic imaging of iron organelles within the pigeon cochlea
Significance: Cuticulosomes are subcellular structures located within the inner ear hair cells of a variety of avian species with potential relevance to magnetoreception. Here we apply quantum magnetic microscopy to image the magnetic properties of individual iron cuticulosomes within tissue samples. The magnetic susceptibility of the cuticulosomes was determined by characterizing the stray magnetic field strength as a function of applied magnetic field in two distinct locations of the pigeon inner ear. The measured susceptibilities do not support the particle model of magnetoreception, suggesting the physiological relevance of cuticulosomes lies in iron storage or stabilization of stereocilia. The quantum magnetic imaging method can be applied across a variety of biological systems providing an effective tool to screen for magnetic particle–based magnetoreceptors.
- Open Access
Magnetic Materials: Rapid, High‐Resolution Magnetic Microscopy of Single Magnetic Microbeads (Small 18/2019)
- 2 February 2018
- Published by American Physical Society (APS) in Physical Review B
- Vol. 97 (8) , 085402
Spin properties of dense near-surface ensembles of nitrogen-vacancy centers in diamond
We present a study of the spin properties of dense layers of near-surface nitrogen-vacancy (NV) centers in diamond created by nitrogen ion implantation. The optically detected magnetic resonance contrast and linewidth, spin coherence time, and spin relaxation time, are measured as a function of implantation energy, dose, annealing temperature, and surface treatment. To track the presence of damage and surface-related spin defects, we perform in situ electron spin resonance spectroscopy through both double electron-electron resonance and cross-relaxation spectroscopy on the NV centers. We find that, for the energy ( keV) and dose () ranges considered, the NV spin properties are mainly governed by the dose via residual implantation-induced paramagnetic defects, but that the resulting magnetic sensitivity is essentially independent of both dose and energy. We then show that the magnetic sensitivity is significantly improved by high-temperature annealing at . Moreover, the spin properties are not significantly affected by oxygen annealing, apart from the spin relaxation time, which is dramatically decreased. Finally, the average NV depth is determined by nuclear magnetic resonance measurements, giving nm at 4–6 keV implantation energy. This study sheds light on the optimal conditions to create dense layers of near-surface NV centers for high-sensitivity sensing and imaging applications.- 2 February 2018
- Published by American Physical Society (APS) in Physical Review B
- Vol. 97 (8) , 085402
Spin properties of dense near-surface ensembles of nitrogen-vacancy centers in diamond
We present a study of the spin properties of dense layers of near-surface nitrogen-vacancy (NV) centers in diamond created by nitrogen ion implantation. The optically detected magnetic resonance contrast and linewidth, spin coherence time, and spin relaxation time, are measured as a function of implantation energy, dose, annealing temperature, and surface treatment. To track the presence of damage and surface-related spin defects, we perform in situ electron spin resonance spectroscopy through both double electron-electron resonance and cross-relaxation spectroscopy on the NV centers. We find that, for the energy ( keV) and dose () ranges considered, the NV spin properties are mainly governed by the dose via residual implantation-induced paramagnetic defects, but that the resulting magnetic sensitivity is essentially independent of both dose and energy. We then show that the magnetic sensitivity is significantly improved by high-temperature annealing at . Moreover, the spin properties are not significantly affected by oxygen annealing, apart from the spin relaxation time, which is dramatically decreased. Finally, the average NV depth is determined by nuclear magnetic resonance measurements, giving nm at 4–6 keV implantation energy. This study sheds light on the optimal conditions to create dense layers of near-surface NV centers for high-sensitivity sensing and imaging applications.