PMPaulo Miller

Paulo Miller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Paulo Miller has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Regenerative strategies in apical surgery with and without biomaterials: a systematic review

    by Alexandra Simões, João Carvalho, Tiago Silva, António Melo-Ferraz, Paulo Miller

    Objectives: This systematic review compares the clinical efficacy and radiographic outcomes of membrane-based regeneration, bone grafting, and platelet concentrates in cavities resulting from apicoectomy, assessing healing rates and the quality of newly formed bone. Methods: Following PRISMA 2020 guidelines, a literature search was performed in PubMed, Cochrane Library, ScienceDirect, Wiley, and Scopus databases for articles published between January 2000 and December 2025. Eligibility criteria were defined using the PICOS framework, and included studies were evaluated based on clinical and radiographic parameters with a minimum follow-up of six months. Results: Eighteen clinical studies were included. Findings were heterogeneous and predominantly of low to very low certainty. Although some studies suggested potential benefits of regenerative adjuncts in complex defects, such as through-and-through and apicomarginal lesions, a substantial proportion found no statistically significant advantage over conventional apical surgery. Smaller lesions (<3 mm) generally responded favorably to conventional surgery, whereas larger defects may benefit from adjunctive regenerative approaches in selected clinical situations. Conclusions: Overall, the available evidence suggests a potential benefit of combining physical support (biomaterials) and biological stimulation (platelet-rich fibrin) in regenerative apical surgery. However, findings remain heterogeneous and should be interpreted cautiously. Technique selection should consider defect morphology, lesion characteristics, and available resources. Further standardized and methodologically robust studies are required to strengthen the current evidence base.

  • Accuracy of the electronic method versus the radiographic method in determining working length: integrative systematic review

    by Celia Eduarda Marques, Marcella Delphim, Rita Fidalgo-Pereira, António Melo-Ferraz, Paulo Miller, Orlanda Torres

    Introduction: The radiographic method is widely used to calculate the working length (CT). However, it presents limitations that, to overcome them, apical electronic locators (LEAs) were developed to allow greater accuracy and reliability in determining the CT. Objective: The present study aims to perform an integrative systematic review and gather the available scientific evidence on the method that allows greater accuracy in determining the CT between the radiographic method and the electronic localisation method (LEA). Materials and Methods: The literature search was performed on the PubMed platform using keywords combined through the Boolean operator AND as follows: ("endodontics" AND "electronic apex locator" AND "radiographic measurement") and ("endodontics" AND "electronic apex locator" AND "radiographic measurement" AND "odontometry"). Results: 68 articles reporting comparative studies performed between the methods, radiographic and LEA, were identified. Eleven studies were included, of which, in some cases, LEAs showed better results than non-digital periapical radiographs. The studies indicate that although there are differences between the two methods, with greater accuracy in determining LEA, the differences did not prove to be statistically significant. In the presence of irrigating solutions, sodium hypochlorite revealed more significant discrepancies in CT determination with the LEA method. Conclusion: The two methods, radiographic and LEA, should be used in association since each has particularities that present more significant benefits enhancing the success of endodontic treatment and a better and more complete treatment for patients.


  • Open Access

    Eficácia das limas reciprocantes Reciproc Blue e ProDesign R na remoção de material obturador: Uma revisão integrativa da literatura

    by Andreia Lilian Viana Farias, Ana Grasiela da Silva Limoeiro, Antônio Melo Ferraz, Wayne Martins Nascimento, Valter Fernandes, Carlos Eduardo da Silveira Bueno, Alexandre Sigrist De Martin, Paulo Miller

    The aim of the present study was to conduct an integrative review on the mechanical properties of Reciproc Blue and ProDesign R reciprocating systems and the efficacy of these files in removing root filling materials. The search was carried out on the PUBMED using following combinations of scientific terms: Reciproc Blue, ProDesign R, resistance, mechanical properties, thermal treatment and endodontic retreatment. The research identified 64 articles, of which 29 were selected for the present study. The articles demonstrated the importance of thermomechanical treatment on elasticity and stiffness of Reciproc Blue and ProDesign R endodontic instruments compared to other systems. It was also observed that both files are effective in removing the filling material from the root canal, however both systems failed to remove it completely.

  • Platelet activation and antimicrobial activity of L-PRF: a preliminary study

    by António Melo-Ferraz, Cristina Coelho, Paulo Miller, Maria Begoña Criado, Maria Céu Monteiro

    Leukocyte and platelet rich fibrin (L-PRF) is one of the platelet concentrates used to support regeneration and healing process. Many studies showed possible immunological and antibacterial properties of L-PRF. We perform an in vitro study to analyze the effect of L-PRF on platelet activation, platelet-leukocytes interactions and antimicrobial activity, important components in the healing process. Molecular biomarkers related with platelet activation and platelet-leukocyte interactions were analyzed by means of flow cytometry when L-PRF exudate was added to whole blood platelets. L-PRF membrane was used to evaluate antimicrobial activity using Enterococcus faecalis (ATCC 29212), Pseudomonas aeruginosa (ATCC 27853) and Candida albicans (ATCC 90028). Our experimental design allows to evaluate platelet activation and analyze molecular biomarkers of other immune cells and platelet-leukocyte interactions. From the results obtained we can conclude that L-PRF can be a valuable tool in healing process, efficient in activating platelets of whole blood and inhibiting microbial growth. In our opinion, the use of L-PRF exudate, in addition to L-PRF membrane, presents some advantages that have to be considered in clinical trials. Additional research on the characterization and quantification of cells and its products present in the L-PRF exudate, as well as on the temporal factor released. Also, further studies using strains isolated from clinical cases are needed.