Tomasz Krzywicki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tomasz Krzywicki has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Andrzej Grzybowski
Department of Ophthalmology University of Warmia and Mazury Olsztyn Poland
6 shared publications Piotr Brona
Department of Ophthalmology Poznań City Hospital Poznań Poland
3 shared publications- Agnieszka M. Zbrzezny
Department of Computer Science Faculty of Design SWPS University Warsaw Poland
2 shared publications - Piotr Brona
Department of Ophthalmology, Poznań City Hospital, Poznań, Poland
2 shared publications - Anna Święch
Department of Vitreoretinal Surgery, Medical University of Lublin, 20-081 Lublin, Poland
1 shared publication - Arleta Berlińska
Department of Ophthalmology, University of Warmia and Mazury, 10-719 Olsztyn, Poland
1 shared publication
Latest Publications
- 2 May 2026
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 288, 267-283
Auto Machine Learning for Diabetic Retinopathy Screening: A Head-to-Head Multiplatform Comparison Against Human Graders and IDx-DR
- 2 May 2026
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 288, 267-283
Auto Machine Learning for Diabetic Retinopathy Screening: A Head-to-Head Multiplatform Comparison Against Human Graders and IDx-DR
- Top Cited PapersOpen Access
- 14 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (14) , 7856
Artificial Intelligence in Dermatology: A Review of Methods, Clinical Applications, and Perspectives
The use of artificial intelligence (AI) in dermatology is skyrocketing, but a comprehensive overview integrating regulatory, ethical, validation, and clinical issues is lacking. This work aims to review current research, map applicable legal regulations, identify ethical challenges and methods of verifying AI models in dermatology, assess publication trends, compare the most popular neural network architectures and datasets, and identify good practices in creating AI-based applications for dermatological use. A systematic literature review is conducted in accordance with the PRISMA guidelines, utilising Google Scholar, PubMed, Scopus, and Web of Science and employing bibliometric analysis. Since 2016, there has been exponential growth in deep learning research in dermatology, revealing gaps in EU and US regulations and significant differences in model performance across different datasets. The decision-making process in clinical dermatology is analysed, focusing on how AI is augmenting skin imaging techniques such as dermatoscopy and histology. Further demonstration is provided regarding how AI is a valuable tool that supports dermatologists by automatically analysing skin images, enabling faster diagnosis and the more accurate identification of skin lesions. These advances enhance the precision and efficiency of dermatological care, showcasing the potential of AI to revolutionise the speed of diagnosis in modern dermatology, sparking excitement and curiosity. Then, we discuss the regulatory framework for AI in medicine, as well as the ethical issues that may arise. Additionally, this article addresses the critical challenge of ensuring the safety and trustworthiness of AI in dermatology, presenting classic examples of safety issues that can arise during its implementation. The review provides recommendations for regulatory harmonisation, the standardisation of validation metrics, and further research on data explainability and representativeness, which can accelerate the safe implementation of AI in dermatological practice.
- 14 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (14) , 7856
Top Cited PapersOpen AccessArtificial Intelligence in Dermatology: A Review of Methods, Clinical Applications, and Perspectives
The use of artificial intelligence (AI) in dermatology is skyrocketing, but a comprehensive overview integrating regulatory, ethical, validation, and clinical issues is lacking. This work aims to review current research, map applicable legal regulations, identify ethical challenges and methods of verifying AI models in dermatology, assess publication trends, compare the most popular neural network architectures and datasets, and identify good practices in creating AI-based applications for dermatological use. A systematic literature review is conducted in accordance with the PRISMA guidelines, utilising Google Scholar, PubMed, Scopus, and Web of Science and employing bibliometric analysis. Since 2016, there has been exponential growth in deep learning research in dermatology, revealing gaps in EU and US regulations and significant differences in model performance across different datasets. The decision-making process in clinical dermatology is analysed, focusing on how AI is augmenting skin imaging techniques such as dermatoscopy and histology. Further demonstration is provided regarding how AI is a valuable tool that supports dermatologists by automatically analysing skin images, enabling faster diagnosis and the more accurate identification of skin lesions. These advances enhance the precision and efficiency of dermatological care, showcasing the potential of AI to revolutionise the speed of diagnosis in modern dermatology, sparking excitement and curiosity. Then, we discuss the regulatory framework for AI in medicine, as well as the ethical issues that may arise. Additionally, this article addresses the critical challenge of ensuring the safety and trustworthiness of AI in dermatology, presenting classic examples of safety issues that can arise during its implementation. The review provides recommendations for regulatory harmonisation, the standardisation of validation metrics, and further research on data explainability and representativeness, which can accelerate the safe implementation of AI in dermatological practice.
- 10 December 2024
- Published by Wiley in Acta Ophthalmologica
- Vol. 103 (4) , 388-395
Evaluating the efficacy of AI systems in diabetic retinopathy detection: A comparative analysis of Mona DR and IDx‐DR
Purpose: To compare two artificial intelligence (AI)‐based Automated Diabetic Retinopathy Image Assessment (ARIA) softwares in terms of concordance with specialist human graders and referable diabetic retinopathy (DR) diagnostic capacity.Methods: Retrospective comparative study including 750 consecutive diabetes mellitus patients imaged for non‐mydriatic fundus photographs. For each patient four images (45 degrees field of view) were captured, centered on the optic disc and macula. Images were manually graded for severity of DR as no DR, any DR (mild non‐proliferative diabetic retinopathy [NPDR] or more), referable DR (RDR (more than mild DR)), or sight‐threatening DR (severe NPDR or more severe disease and/or clinically significant diabetic macular edema [CSDME]). IDx‐DR and MONA DR output was compared with manual grading and with each other.Results: Total sample size was 750 patients, of which 55 were excluded due to ungradable images. Out of the remaining 695 patients 522 (75%) were considered as having no DR by manual consensus grading, and 106 (15%) as having RDR. Agreement between raters varied between moderate to substantial. IDx‐DR showed moderate agreement with human grading (k = 0.4285) while MONA DR had substantial agreement (k = 0.6797). Out of 106 patients with a ground truth of RDR, IDx‐DR identified 105 and MONA DR identified 99. The sensitivity and specificity rates for RDR detection of IDx‐DR were 99.1 and 71.5% compared with MONA DR of 93.4 and 89.3% respectively. Of note, both ARIAs had 100% sensitivity for the detection of STDR.Conclusion: Both ARIAs performed well in this study population, both with sensitivity for RDR screening over 90%, with IDx‐DR showing higher sensitivity and MONA DR higher specificity. MONA DR showed superior agreement with human certified graders.
- 10 December 2024
- Published by Wiley in Acta Ophthalmologica
- Vol. 103 (4) , 388-395
Evaluating the efficacy of AI systems in diabetic retinopathy detection: A comparative analysis of Mona DR and IDx‐DR
Purpose: To compare two artificial intelligence (AI)‐based Automated Diabetic Retinopathy Image Assessment (ARIA) softwares in terms of concordance with specialist human graders and referable diabetic retinopathy (DR) diagnostic capacity.Methods: Retrospective comparative study including 750 consecutive diabetes mellitus patients imaged for non‐mydriatic fundus photographs. For each patient four images (45 degrees field of view) were captured, centered on the optic disc and macula. Images were manually graded for severity of DR as no DR, any DR (mild non‐proliferative diabetic retinopathy [NPDR] or more), referable DR (RDR (more than mild DR)), or sight‐threatening DR (severe NPDR or more severe disease and/or clinically significant diabetic macular edema [CSDME]). IDx‐DR and MONA DR output was compared with manual grading and with each other.Results: Total sample size was 750 patients, of which 55 were excluded due to ungradable images. Out of the remaining 695 patients 522 (75%) were considered as having no DR by manual consensus grading, and 106 (15%) as having RDR. Agreement between raters varied between moderate to substantial. IDx‐DR showed moderate agreement with human grading (k = 0.4285) while MONA DR had substantial agreement (k = 0.6797). Out of 106 patients with a ground truth of RDR, IDx‐DR identified 105 and MONA DR identified 99. The sensitivity and specificity rates for RDR detection of IDx‐DR were 99.1 and 71.5% compared with MONA DR of 93.4 and 89.3% respectively. Of note, both ARIAs had 100% sensitivity for the detection of STDR.Conclusion: Both ARIAs performed well in this study population, both with sensitivity for RDR screening over 90%, with IDx‐DR showing higher sensitivity and MONA DR higher specificity. MONA DR showed superior agreement with human certified graders.
- Open Access
- 6 November 2024
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 14 (1) , 73-84
Diagnostic Accuracy of Automated Diabetic Retinopathy Image Assessment Software: IDx-DR and RetCAD
Introduction: Automated diabetic retinopathy (DR) screening using artificial intelligence has the potential to improve access to eye care by enabling large-scale screening. However, little is known about differences in real-world performance between available algorithms. This study compares the diagnostic accuracy of two AI screening platforms, IDx-DR and RetCAD, for detecting referable diabetic retinopathy (RDR). Methods: Retinal images from 758 patients with diabetes were collected during screening from various clinics in Poland. Each patient was graded by three graders with 320 patients graded by Polish and 438 patients graded by Indian graders, with the majority decision serving as the reference standard. The images were evaluated independently by the IDx-DR and RetCAD algorithms. Sensitivity, specificity, positive and negative predictive values, and agreement between algorithms and human graders were calculated and statistically compared. Results: IDx-DR demonstrated higher sensitivity of 99.3% but lower specificity of 68.9% for RDR detection compared to RetCAD which had 89.4% sensitivity and 94.8% specificity. The positive predictive value was higher for RetCAD (96.4% vs 48.1% for IDx-DR) while the negative predictive value was higher for IDx-DR (99.5% vs 83.1% for RetCAD). Both algorithms achieved high sensitivity (> 95%) for sight-threatening diabetic retinopathy detection. Conclusion: In this direct comparison using the same patient cohort, the two algorithms showed differences in their operating parameters for RDR screening. IDx-DR prioritized avoiding false negatives over false positives while RetCAD maintained a more balanced trade-off. These results highlight the variable performance of current artificial intelligence screening solutions and suggest the importance of considering algorithm performance metrics when deploying automated diabetic retinopathy screening programs, based on available healthcare resources.
- 6 November 2024
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 14 (1) , 73-84
Open AccessDiagnostic Accuracy of Automated Diabetic Retinopathy Image Assessment Software: IDx-DR and RetCAD
Introduction: Automated diabetic retinopathy (DR) screening using artificial intelligence has the potential to improve access to eye care by enabling large-scale screening. However, little is known about differences in real-world performance between available algorithms. This study compares the diagnostic accuracy of two AI screening platforms, IDx-DR and RetCAD, for detecting referable diabetic retinopathy (RDR). Methods: Retinal images from 758 patients with diabetes were collected during screening from various clinics in Poland. Each patient was graded by three graders with 320 patients graded by Polish and 438 patients graded by Indian graders, with the majority decision serving as the reference standard. The images were evaluated independently by the IDx-DR and RetCAD algorithms. Sensitivity, specificity, positive and negative predictive values, and agreement between algorithms and human graders were calculated and statistically compared. Results: IDx-DR demonstrated higher sensitivity of 99.3% but lower specificity of 68.9% for RDR detection compared to RetCAD which had 89.4% sensitivity and 94.8% specificity. The positive predictive value was higher for RetCAD (96.4% vs 48.1% for IDx-DR) while the negative predictive value was higher for IDx-DR (99.5% vs 83.1% for RetCAD). Both algorithms achieved high sensitivity (> 95%) for sight-threatening diabetic retinopathy detection. Conclusion: In this direct comparison using the same patient cohort, the two algorithms showed differences in their operating parameters for RDR screening. IDx-DR prioritized avoiding false negatives over false positives while RetCAD maintained a more balanced trade-off. These results highlight the variable performance of current artificial intelligence screening solutions and suggest the importance of considering algorithm performance metrics when deploying automated diabetic retinopathy screening programs, based on available healthcare resources.
- Open Access
- 27 September 2023
- Published by S. Karger AG in Ophthalmic Research
- Vol. 66 (1) , 1286-1292
Diagnostic Accuracy of Automated Diabetic Retinopathy Image Assessment Softwares: IDx-DR and Medios Artificial Intelligence
Introduction: Numerous studies have demonstrated the use of artificial intelligence (AI) for early detection of referable diabetic retinopathy (RDR). A direct comparison of these multiple automated diabetic retinopathy (DR) image assessment softwares (ARIAs) is, however, challenging. We retrospectively compared the performance of two modern ARIAs, IDx-DR and Medios AI. Methods: In this retrospective-comparative study, retinal images with sufficient image quality were run on both ARIAs. They were captured in 811 consecutive patients with diabetes visiting diabetic clinics in Poland. For each patient, four non-mydriatic images, 45° field of view, i.e., two sets of one optic disc and one macula-centered image using Topcon NW400 were captured. Images were manually graded for severity of DR as no DR, any DR (mild non-proliferative diabetic retinopathy [NPDR] or more severe disease), RDR (moderate NPDR or more severe disease and/or clinically significant diabetic macular edema [CSDME]), or sight-threatening DR (severe NPDR or more severe disease and/or CSDME) by certified graders. The ARIA output was compared to manual consensus image grading (reference standard). Results: On 807 patients, based on consensus grading, there was no evidence of DR in 543 patients (67%). Any DR was seen in 264 (33%) patients, of which 174 (22%) were RDR and 41 (5%) were sight-threatening DR. The sensitivity of detecting RDR against reference standard grading was 95% (95% CI: 91, 98%) and the specificity was 80% (95% CI: 77, 83%) for Medios AI. They were 99% (95% CI: 96, 100%) and 68% (95% CI: 64, 72%) for IDx-DR, respectively. Conclusion: Both the ARIAs achieved satisfactory accuracy, with few false negatives. Although false-positive results generate additional costs and workload, missed cases raise the most concern whenever automated screening is debated.
- 27 September 2023
- Published by S. Karger AG in Ophthalmic Research
- Vol. 66 (1) , 1286-1292
Open AccessDiagnostic Accuracy of Automated Diabetic Retinopathy Image Assessment Softwares: IDx-DR and Medios Artificial Intelligence
Introduction: Numerous studies have demonstrated the use of artificial intelligence (AI) for early detection of referable diabetic retinopathy (RDR). A direct comparison of these multiple automated diabetic retinopathy (DR) image assessment softwares (ARIAs) is, however, challenging. We retrospectively compared the performance of two modern ARIAs, IDx-DR and Medios AI. Methods: In this retrospective-comparative study, retinal images with sufficient image quality were run on both ARIAs. They were captured in 811 consecutive patients with diabetes visiting diabetic clinics in Poland. For each patient, four non-mydriatic images, 45° field of view, i.e., two sets of one optic disc and one macula-centered image using Topcon NW400 were captured. Images were manually graded for severity of DR as no DR, any DR (mild non-proliferative diabetic retinopathy [NPDR] or more severe disease), RDR (moderate NPDR or more severe disease and/or clinically significant diabetic macular edema [CSDME]), or sight-threatening DR (severe NPDR or more severe disease and/or CSDME) by certified graders. The ARIA output was compared to manual consensus image grading (reference standard). Results: On 807 patients, based on consensus grading, there was no evidence of DR in 543 patients (67%). Any DR was seen in 264 (33%) patients, of which 174 (22%) were RDR and 41 (5%) were sight-threatening DR. The sensitivity of detecting RDR against reference standard grading was 95% (95% CI: 91, 98%) and the specificity was 80% (95% CI: 77, 83%) for Medios AI. They were 99% (95% CI: 96, 100%) and 68% (95% CI: 64, 72%) for IDx-DR, respectively. Conclusion: Both the ARIAs achieved satisfactory accuracy, with few false negatives. Although false-positive results generate additional costs and workload, missed cases raise the most concern whenever automated screening is debated.
- Open Access
- 21 May 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (10) , 3587
A Global Review of Publicly Available Datasets Containing Fundus Images: Characteristics, Barriers to Access, Usability, and Generalizability
This article provides a comprehensive and up-to-date overview of the repositories that contain color fundus images. We analyzed them regarding availability and legality, presented the datasets’ characteristics, and identified labeled and unlabeled image sets. This study aimed to complete all publicly available color fundus image datasets to create a central catalog of available color fundus image datasets.
- 21 May 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (10) , 3587
Open AccessA Global Review of Publicly Available Datasets Containing Fundus Images: Characteristics, Barriers to Access, Usability, and Generalizability
This article provides a comprehensive and up-to-date overview of the repositories that contain color fundus images. We analyzed them regarding availability and legality, presented the datasets’ characteristics, and identified labeled and unlabeled image sets. This study aimed to complete all publicly available color fundus image datasets to create a central catalog of available color fundus image datasets.
- 22 December 2022
Systemy uczące się - sztuczne sieci neuronowe i uczenie głębokie
- Open Access
- 31 May 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (11) , 3125
Variability of Grading DR Screening Images among Non-Trained Retina Specialists
Poland has never had a widespread diabetic retinopathy (DR) screening program and subsequently has no purpose-trained graders and no established grader training scheme. Herein, we compare the performance and variability of three retinal specialists with no additional DR grading training in assessing images from 335 real-life screening encounters and contrast their performance against IDx-DR, a US Food and Drug Administration (FDA) approved DR screening suite. A total of 1501 fundus images from 670 eyes were assessed by each grader with a final grade on a per-eye level. Unanimous agreement between all graders was achieved for 385 eyes, and 110 patients, out of which 98% had a final grade of no DR. Thirty-six patients had final grades higher than mild DR, out of which only two had no grader disagreements regarding severity. A total of 28 eyes underwent adjudication due to complete grader disagreement. Four patients had discordant grades ranging from no DR to severe DR between the human graders and IDx-DR. Retina specialists achieved kappa scores of 0.52, 0.78, and 0.61. Retina specialists had relatively high grader variability and only a modest concordance with IDx-DR results. Focused training and verification are recommended for any potential DR graders before assessing DR screening images.
- 31 May 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (11) , 3125
Open AccessVariability of Grading DR Screening Images among Non-Trained Retina Specialists
Poland has never had a widespread diabetic retinopathy (DR) screening program and subsequently has no purpose-trained graders and no established grader training scheme. Herein, we compare the performance and variability of three retinal specialists with no additional DR grading training in assessing images from 335 real-life screening encounters and contrast their performance against IDx-DR, a US Food and Drug Administration (FDA) approved DR screening suite. A total of 1501 fundus images from 670 eyes were assessed by each grader with a final grade on a per-eye level. Unanimous agreement between all graders was achieved for 385 eyes, and 110 patients, out of which 98% had a final grade of no DR. Thirty-six patients had final grades higher than mild DR, out of which only two had no grader disagreements regarding severity. A total of 28 eyes underwent adjudication due to complete grader disagreement. Four patients had discordant grades ranging from no DR to severe DR between the human graders and IDx-DR. Retina specialists achieved kappa scores of 0.52, 0.78, and 0.61. Retina specialists had relatively high grader variability and only a modest concordance with IDx-DR results. Focused training and verification are recommended for any potential DR graders before assessing DR screening images.
- 14 October 2021
- Published by Springer Nature
- p. 77-86
Selected Image Analysis Methods for Ophthalmology
- 14 October 2021
- Published by Springer Nature
- p. 77-86
Selected Image Analysis Methods for Ophthalmology