Amir Tavakoli
Research Subjects
Amir Tavakoli has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- G. Daniel G. Langohr
Department of Mechanical Engineering, Western University, London, ON, Canada; The Roth|McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada; Department of Surgery, Western University, London, ON, Canada
2 shared publications - Gregory W. Spangenberg
Department of Mechanical Engineering, Western University, London, ON, Canada; The Roth McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada
2 shared publications - Jacob M. Reeves
Department of Mechanical and Materials Engineering, Western University, London, Ontario, Canada
2 shared publications - Kenneth J. Faber
Clinical Research Lab, Roth McFarlane Hand and Upper Limb Centre, St. Joseph’s Healthcare, London, Canada
2 shared publications Andreas M€ Uller
Camden, NJ, USA .
1 shared publicationBrett P. Wiater
Camden, NJ, USA .
1 shared publication
Latest Publications
- Open Access
- 15 September 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 32 (10) , A2-A10
Table of Contents
- 15 September 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 32 (10) , A2-A10
Open AccessTable of Contents
- 23 May 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 32 (10) , 1988-1998
The effect of humeral head positioning and incomplete backside contact on bone stresses following total shoulder arthroplasty with a short humeral stem
- 23 May 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 32 (10) , 1988-1998
The effect of humeral head positioning and incomplete backside contact on bone stresses following total shoulder arthroplasty with a short humeral stem
- 10 May 2021
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 40 (3) , 674-684
Structural analysis of hollow versus solid‐stemmed shoulder implants of proximal humeri with different bone qualities
Stress shielding of the proximal humerus following total shoulder arthroplasty (TSA) can promote unfavorable bone remodeling, especially for osteoporotic patients. The objective of this finite element (FE) study was to determine if a hollow, rather than solid, titanium stem can mitigate this effect for healthy, osteopenic, and osteoporotic bone. Using a population‐based model of the humerus, representative average healthy, osteopenic, and osteoporotic humerus FE models were created. For each model, changes in bone and implant stresses following TSA were evaluated for different loading scenarios and compared between solid versus hollow‐stemmed implants. For cortical bone, using an implant decreased von Mises stress with respect to intact values up to 34.4%, with a more pronounced effect at more proximal slices. In the most proximal slice, based on changes in strain energy density, hollow‐stemmed implants outperformed solid‐stemmed ones through reducing cortical bone volume with resorption potential by 11.7% ± 2.1% (p = .01). For cortical bone in this slice, the percentage of bone with resorption potential for the osteoporotic bone was greater than the healthy bone by 8.0% ± 1.4% using the hollow‐stemmed implant (p = .04). These results suggest a small improvement in bone‐implant mechanics using hollow‐stemmed humeral implants and indicate osteoporosis could exacerbate stress shielding to some extent. The hollow stems maintained adequate strength and using even thinner walls may further reduce stress shielding. After further developing these models, future studies could yield optimized implant designs tuned for varying bone qualities.
- 10 May 2021
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 40 (3) , 674-684
Structural analysis of hollow versus solid‐stemmed shoulder implants of proximal humeri with different bone qualities
Stress shielding of the proximal humerus following total shoulder arthroplasty (TSA) can promote unfavorable bone remodeling, especially for osteoporotic patients. The objective of this finite element (FE) study was to determine if a hollow, rather than solid, titanium stem can mitigate this effect for healthy, osteopenic, and osteoporotic bone. Using a population‐based model of the humerus, representative average healthy, osteopenic, and osteoporotic humerus FE models were created. For each model, changes in bone and implant stresses following TSA were evaluated for different loading scenarios and compared between solid versus hollow‐stemmed implants. For cortical bone, using an implant decreased von Mises stress with respect to intact values up to 34.4%, with a more pronounced effect at more proximal slices. In the most proximal slice, based on changes in strain energy density, hollow‐stemmed implants outperformed solid‐stemmed ones through reducing cortical bone volume with resorption potential by 11.7% ± 2.1% (p = .01). For cortical bone in this slice, the percentage of bone with resorption potential for the osteoporotic bone was greater than the healthy bone by 8.0% ± 1.4% using the hollow‐stemmed implant (p = .04). These results suggest a small improvement in bone‐implant mechanics using hollow‐stemmed humeral implants and indicate osteoporosis could exacerbate stress shielding to some extent. The hollow stems maintained adequate strength and using even thinner walls may further reduce stress shielding. After further developing these models, future studies could yield optimized implant designs tuned for varying bone qualities.