Xiyu Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xiyu Liu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Hong Guo
Peking University
3 shared publications - Teng Wu
Peking University
3 shared publications - Wei Xiao
Peking University
3 shared publications - Xiang Peng
Peking University
2 shared publications - Chenxi Sun
Peking University
1 shared publication - Jianwei Wang
Hunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Xiangtan 411105, China
1 shared publication
Latest Publications
- 29 October 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (18) , 183201
Search for Exotic Spin-Dependent Interactions with Dressed Atoms
We present a method to engineer the Landé g factor of alkali-metal atoms using spin-exchange collisions and nonresonant radio-frequency (rf) magnetic-field dressing. We analyze schemes with both linearly and circularly polarized rf dressing to generate dressed states, allowing the responses to magnetic and nonmagnetic spin-dependent interactions, such as the spin-gravity interaction, to be distinguished in the output signal. Our method provides a complementary approach to conventional comagnetometry in the investigation of exotic spin-dependent interactions and gyroscopes.
- 29 October 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (18) , 183201
Search for Exotic Spin-Dependent Interactions with Dressed Atoms
We present a method to engineer the Landé g factor of alkali-metal atoms using spin-exchange collisions and nonresonant radio-frequency (rf) magnetic-field dressing. We analyze schemes with both linearly and circularly polarized rf dressing to generate dressed states, allowing the responses to magnetic and nonmagnetic spin-dependent interactions, such as the spin-gravity interaction, to be distinguished in the output signal. Our method provides a complementary approach to conventional comagnetometry in the investigation of exotic spin-dependent interactions and gyroscopes.
- 27 August 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 133 (9) , 093201
Radio-Frequency Magnetometry Based on Parametric Resonances
We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of , which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.- 27 August 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 133 (9) , 093201
Radio-Frequency Magnetometry Based on Parametric Resonances
We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of , which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.- Top Cited Papers
- 31 March 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (13) , eadg1746
A movable unshielded magnetocardiography system
Magnetocardiography (MCG), which uses high-sensitivity magnetometers to record magnetic field signals generated by electrical activity in the heart, is a noninvasive method for evaluating heart diseases such as arrhythmia and ischemia. The MCG measurements usually require the participant keeping still in a magnetically shielded room due to the immovable sensor and noisy external environments. These requirements limit MCG applications, such as exercise MCG tests and long-term MCG observations, which are useful for early detections of heart diseases. Here, we introduce a movable MCG system that can clearly record MCG signals of freely behaving participants in an unshielded environment. On the basis of optically pumped magnetometers with a sensitivity of 140 fT/Hz1/2, we successfully demonstrated the resting MCG and the exercise MCG tests. Our method is promising to realize a practical movable multichannel unshielded MCG system that nearly sets no limits to participants and brings another kind of insight into the medical diagnosis of heart disease.
- 31 March 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (13) , eadg1746
Top Cited PapersA movable unshielded magnetocardiography system
Magnetocardiography (MCG), which uses high-sensitivity magnetometers to record magnetic field signals generated by electrical activity in the heart, is a noninvasive method for evaluating heart diseases such as arrhythmia and ischemia. The MCG measurements usually require the participant keeping still in a magnetically shielded room due to the immovable sensor and noisy external environments. These requirements limit MCG applications, such as exercise MCG tests and long-term MCG observations, which are useful for early detections of heart diseases. Here, we introduce a movable MCG system that can clearly record MCG signals of freely behaving participants in an unshielded environment. On the basis of optically pumped magnetometers with a sensitivity of 140 fT/Hz1/2, we successfully demonstrated the resting MCG and the exercise MCG tests. Our method is promising to realize a practical movable multichannel unshielded MCG system that nearly sets no limits to participants and brings another kind of insight into the medical diagnosis of heart disease.
- Open Access
A Tubular Flexible Triboelectric Nanogenerator with a Superhydrophobic Surface for Human Motion Detecting
The triboelectric nanogenerator (TENG) is a newly arisen technology for mechanical energy harvesting from the environment, such as raindrops, wind, tides, and so on. It has attracted widespread attention in flexible electronics to serve as self-powered sensors and energy-harvesting devices because of its flexibility, durability, adaptability, and multi-functionalities. In this work, we fabricated a tubular flexible triboelectric nanogenerator (TF-TENG) with energy harvesting and human motion monitoring capabilities by employing polydimethylsiloxane (PDMS) as construction material, and fluorinated ethylene propylene (FEP) films coated with Cu as the triboelectric layer and electrode, serving in a free-standing mode. The tube structure has excellent stretchability that can be stretched up to 400%. Modifying the FEP films to obtain a superhydrophobic surface, the output performance of TF-TENG was increased by at least 100% compared to an untreated one. Finally, as the output of TF-TENG is sensitive to swing angle and frequency, demonstration of real-time monitoring of human motion state was realized when a TF-TENG was worn on the wrist.
Open AccessA Tubular Flexible Triboelectric Nanogenerator with a Superhydrophobic Surface for Human Motion Detecting
The triboelectric nanogenerator (TENG) is a newly arisen technology for mechanical energy harvesting from the environment, such as raindrops, wind, tides, and so on. It has attracted widespread attention in flexible electronics to serve as self-powered sensors and energy-harvesting devices because of its flexibility, durability, adaptability, and multi-functionalities. In this work, we fabricated a tubular flexible triboelectric nanogenerator (TF-TENG) with energy harvesting and human motion monitoring capabilities by employing polydimethylsiloxane (PDMS) as construction material, and fluorinated ethylene propylene (FEP) films coated with Cu as the triboelectric layer and electrode, serving in a free-standing mode. The tube structure has excellent stretchability that can be stretched up to 400%. Modifying the FEP films to obtain a superhydrophobic surface, the output performance of TF-TENG was increased by at least 100% compared to an untreated one. Finally, as the output of TF-TENG is sensitive to swing angle and frequency, demonstration of real-time monitoring of human motion state was realized when a TF-TENG was worn on the wrist.