Phan Tan Toi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Phan Tan Toi has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Jang-Yeon Park
Department of Biomedical Engineering, Sungkyunkwan University
5 shared publications - Bernard Lanz
CIBM Center for Biomedical Imaging, Lausanne, Switzerland
4 shared publications Brayan Alves
CIBM Center for Biomedical Imaging, Lausanne, Switzerland
4 shared publications- Cristina Cudalbu
CIBM Center for Biomedical Imaging, Lausanne, Switzerland
4 shared publications - Nae-Eung Lee
School of Advanced Materials Science & Engineering, Sungkyunkwan University, Suwon, Gyeonggi-do 16419, Republic of Korea
4 shared publications - Alessio Siviglia
CIBM Center for Biomedical Imaging, Lausanne, Switzerland
3 shared publications
Latest Publications
- Open Access
Impacts of retrospective lipid suppression on metabolite quantification in preclinical proton MR spectroscopic imaging
Extracranial lipid contamination remains a challenge in proton magnetic resonance spectroscopic imaging (MRSI), especially in short acquisition delay MRSI, where broad lipid resonances overlap with metabolite and macromolecular signals. Although retrospective lipid suppression techniques are widely used in human MRSI, their effects on metabolite quantification in preclinical MRSI, which is more prone to lipid contamination, have not yet been examined. In this study, we assessed how the retrospective lipid suppression and spectral fitting range influence spectral quality, spatial metabolite mapping, and quantification variability using proton MRSI of rat brains at 14.1 T. Lipid suppression was applied via an orthogonal projection method to both fully sampled and compressed sensing datasets, each comprising data with minimal and pronounced lipid contamination. Spectral fitting was performed with both broad (4.1 - 0.2 ppm) and narrow (4.1 - 1.8 ppm) ranges. When lipid contamination was minimal, suppression caused only slight spectral and spatial changes, with consistent metabolite quantification across conditions. In contrast, datasets with pronounced lipid contamination exhibited notable spectral changes following suppression, consequently affecting spatial metabolite mapping and concentration estimates. Group analysis revealed that metabolites with low concentration estimates were most affected. Similar effects were observed in compressed sensing datasets. Our results provide a better understanding of the impact of retrospective lipid suppression on metabolite quantification in preclinical MRSI, thereby supporting future optimizations for its effective application.
Open AccessImpacts of retrospective lipid suppression on metabolite quantification in preclinical proton MR spectroscopic imaging
Extracranial lipid contamination remains a challenge in proton magnetic resonance spectroscopic imaging (MRSI), especially in short acquisition delay MRSI, where broad lipid resonances overlap with metabolite and macromolecular signals. Although retrospective lipid suppression techniques are widely used in human MRSI, their effects on metabolite quantification in preclinical MRSI, which is more prone to lipid contamination, have not yet been examined. In this study, we assessed how the retrospective lipid suppression and spectral fitting range influence spectral quality, spatial metabolite mapping, and quantification variability using proton MRSI of rat brains at 14.1 T. Lipid suppression was applied via an orthogonal projection method to both fully sampled and compressed sensing datasets, each comprising data with minimal and pronounced lipid contamination. Spectral fitting was performed with both broad (4.1 - 0.2 ppm) and narrow (4.1 - 1.8 ppm) ranges. When lipid contamination was minimal, suppression caused only slight spectral and spatial changes, with consistent metabolite quantification across conditions. In contrast, datasets with pronounced lipid contamination exhibited notable spectral changes following suppression, consequently affecting spatial metabolite mapping and concentration estimates. Group analysis revealed that metabolites with low concentration estimates were most affected. Similar effects were observed in compressed sensing datasets. Our results provide a better understanding of the impact of retrospective lipid suppression on metabolite quantification in preclinical MRSI, thereby supporting future optimizations for its effective application.
- 3 July 2026
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 39 (5) , 943
Correction: MRS4Brain: a software for preclinical proton and deuterium-based MR spectroscopic imaging data
- 3 July 2026
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 39 (5) , 943
Correction: MRS4Brain: a software for preclinical proton and deuterium-based MR spectroscopic imaging data
- Open Access
- 8 April 2026
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 39 (3) , 395-416
Mastering preclinical proton and deuterium-based fast MRSI in the brain: from setup to execution
MR experiments are essential for studying brain metabolism, yet preclinical MRSI remains underdeveloped, with significant limitations in SNR, acquisition speed, and automated data processing. Although recent advances—such as accelerated sequences, denoising strategies, and ultra-high-field systems—have begun to reduce these barriers; preclinical MRSI still lags far behind the human research field in accessibility and routine use. Based on our expertise, we have created this guide that outlines a complete workflow for acquiring and analyzing high-quality fast-proton and deuterium-based MRSI data in rodent brains at ultra-high fields (9.4 T and 14.1 T), enabling novice users to perform reliable experiments using optimized MRSI sequences (FID-MRSI, SE-MRSI, and PRESS-MRSI) and standardized processing pipelines, while also highlighting strategies to further improve acquisition speed, coverage, and reproducibility. Overall, this paper provides a strong foundation for future methodological advances that will expand metabolic imaging capabilities and deepen insights into brain metabolism and disease.
- 8 April 2026
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 39 (3) , 395-416
Open AccessMastering preclinical proton and deuterium-based fast MRSI in the brain: from setup to execution
MR experiments are essential for studying brain metabolism, yet preclinical MRSI remains underdeveloped, with significant limitations in SNR, acquisition speed, and automated data processing. Although recent advances—such as accelerated sequences, denoising strategies, and ultra-high-field systems—have begun to reduce these barriers; preclinical MRSI still lags far behind the human research field in accessibility and routine use. Based on our expertise, we have created this guide that outlines a complete workflow for acquiring and analyzing high-quality fast-proton and deuterium-based MRSI data in rodent brains at ultra-high fields (9.4 T and 14.1 T), enabling novice users to perform reliable experiments using optimized MRSI sequences (FID-MRSI, SE-MRSI, and PRESS-MRSI) and standardized processing pipelines, while also highlighting strategies to further improve acquisition speed, coverage, and reproducibility. Overall, this paper provides a strong foundation for future methodological advances that will expand metabolic imaging capabilities and deepen insights into brain metabolism and disease.
- Open Access
- 8 April 2026
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 39 (3) , 361-379
MRS4Brain: a software for preclinical proton and deuterium-based MR spectroscopic imaging data
Objectives: Magnetic resonance spectroscopic imaging (MRSI) is a non-invasive technique for probing metabolism. MRSI enables spatial mapping of metabolite distributions, offering insights into regional metabolic heterogeneity that single-voxel spectroscopy (SVS) cannot capture. However, MRSI produces large multidimensional datasets and requires complex processing pipelines, limiting reproducibility and accessibility. While human studies benefit from advanced processing tools, similar developments in preclinical research remain scarce, highlighting a demand for practical tools accessible to non-experts. Furthermore, recent advances in deuterium-based MRSI have opened metabolic pathway studies, introducing additional dimensions for kinetic information and specific positional labeling, thus substantially increasing dataset complexity and analysis demands. Methods: To address these needs, we introduce the MRS4Brain Toolbox , a freely available MATLAB-based platform for preclinical MRSI supporting proton, deuterium, and other nuclei, with extended functionalities for SVS and diffusion-weighted spectroscopy. Results: The toolbox integrates reconstruction, preprocessing, quantification, quality control, brain segmentation automatically overlaid on metabolite maps, modeling, and statistical analysis into unified workflows accessible via a graphical interface. Conclusion: By streamlining data processing and reducing technical barriers, MRS4Brain Toolbox promotes reproducibility, harmonization, and broader adoption of basic and advanced spectroscopic techniques in preclinical studies, ultimately facilitating translational metabolic research.
- 8 April 2026
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 39 (3) , 361-379
Open AccessMRS4Brain: a software for preclinical proton and deuterium-based MR spectroscopic imaging data
Objectives: Magnetic resonance spectroscopic imaging (MRSI) is a non-invasive technique for probing metabolism. MRSI enables spatial mapping of metabolite distributions, offering insights into regional metabolic heterogeneity that single-voxel spectroscopy (SVS) cannot capture. However, MRSI produces large multidimensional datasets and requires complex processing pipelines, limiting reproducibility and accessibility. While human studies benefit from advanced processing tools, similar developments in preclinical research remain scarce, highlighting a demand for practical tools accessible to non-experts. Furthermore, recent advances in deuterium-based MRSI have opened metabolic pathway studies, introducing additional dimensions for kinetic information and specific positional labeling, thus substantially increasing dataset complexity and analysis demands. Methods: To address these needs, we introduce the MRS4Brain Toolbox , a freely available MATLAB-based platform for preclinical MRSI supporting proton, deuterium, and other nuclei, with extended functionalities for SVS and diffusion-weighted spectroscopy. Results: The toolbox integrates reconstruction, preprocessing, quantification, quality control, brain segmentation automatically overlaid on metabolite maps, modeling, and statistical analysis into unified workflows accessible via a graphical interface. Conclusion: By streamlining data processing and reducing technical barriers, MRS4Brain Toolbox promotes reproducibility, harmonization, and broader adoption of basic and advanced spectroscopic techniques in preclinical studies, ultimately facilitating translational metabolic research.
- Open Access
- 17 April 2025
- Published by eLife Sciences Publications, Ltd in eLife preprints
- Vol. 13
Responses to membrane potential-modulating ionic solutions measured by magnetic resonance imaging of cultured cells and in vivo rat cortex
Membrane potential plays a crucial role in various cellular functions. However, existing techniques for measuring membrane potential are often invasive or have limited recording depth. In contrast, magnetic resonance imaging (MRI) offers noninvasive imaging with desirable spatial resolution over large areas. This study investigates the feasibility of utilizing MRI to detect responses of cultured cells and in vivo rat cortex to membrane potential-modulating ionic solutions by measuring magnetic resonance parameters. Our findings reveal that depolarizing (or hyperpolarizing) ionic solutions increase (or decrease) the T2 relaxation time, while the ratio of bound to free water proton shows the opposite trend. These findings also suggest a potential approach to noninvasively detect changes in membrane potential using MRI.
- 17 April 2025
- Published by eLife Sciences Publications, Ltd in eLife preprints
- Vol. 13
Open AccessResponses to membrane potential-modulating ionic solutions measured by magnetic resonance imaging of cultured cells and in vivo rat cortex
Membrane potential plays a crucial role in various cellular functions. However, existing techniques for measuring membrane potential are often invasive or have limited recording depth. In contrast, magnetic resonance imaging (MRI) offers noninvasive imaging with desirable spatial resolution over large areas. This study investigates the feasibility of utilizing MRI to detect responses of cultured cells and in vivo rat cortex to membrane potential-modulating ionic solutions by measuring magnetic resonance parameters. Our findings reveal that depolarizing (or hyperpolarizing) ionic solutions increase (or decrease) the T2 relaxation time, while the ratio of bound to free water proton shows the opposite trend. These findings also suggest a potential approach to noninvasively detect changes in membrane potential using MRI.
- Open Access
Direct imaging of neural activity reveals neural circuits via spatiotemporal activation mapping
Two years ago, our group reported direct imaging of neuronal activity (DIANA), a functional magnetic resonance imaging (fMRI) technique that directly detects neuronal activity at high spatiotemporal resolution. In this study, we successfully reproduced the DIANA response in medetomidine-anesthetized mice using forelimb electrical stimulation at 11.7 T. More importantly, we showed that multiple neural circuits can be effectively revealed by DIANA fMRI through spatiotemporal activation mapping. The spatiotemporal activation mapping proposed here utilizes the temporal information of the DIANA response, that is, the time when the DIANA response reaches its peak, which is a unique feature that distinguishes it from the activation mapping method used in existing fMRI. Based on DIANA activation areas, we identified several neural circuits involved in forelimb sensory processing in the somatosensory network, which includes multiple brain regions: ventral posterolateral nucleus of the thalamus (VPL), posteromedial thalamic nucleus (POm), forelimb primary somatosensory cortex (S1FL), secondary somatosensory cortex (S2), primary motor cortex (M1), and secondary motor cortex (M2). Additionally, we also identified a pain-related neural circuit involving brain regions of the anterior cingulate cortex (ACC) and mediodorsal nucleus (MD). Interestingly, the spatiotemporal activation mapping also allowed us to identify subregions with different DIANA response times within the same functional region (e.g., VPL, POm, S1FL, and S2). Our study highlights the potential of DIANA fMRI to advance our understanding of sensory information processing throughout the brain and to provide insight into the spatiotemporal dynamics of brain networks at the level of neural circuits.
Open AccessDirect imaging of neural activity reveals neural circuits via spatiotemporal activation mapping
Two years ago, our group reported direct imaging of neuronal activity (DIANA), a functional magnetic resonance imaging (fMRI) technique that directly detects neuronal activity at high spatiotemporal resolution. In this study, we successfully reproduced the DIANA response in medetomidine-anesthetized mice using forelimb electrical stimulation at 11.7 T. More importantly, we showed that multiple neural circuits can be effectively revealed by DIANA fMRI through spatiotemporal activation mapping. The spatiotemporal activation mapping proposed here utilizes the temporal information of the DIANA response, that is, the time when the DIANA response reaches its peak, which is a unique feature that distinguishes it from the activation mapping method used in existing fMRI. Based on DIANA activation areas, we identified several neural circuits involved in forelimb sensory processing in the somatosensory network, which includes multiple brain regions: ventral posterolateral nucleus of the thalamus (VPL), posteromedial thalamic nucleus (POm), forelimb primary somatosensory cortex (S1FL), secondary somatosensory cortex (S2), primary motor cortex (M1), and secondary motor cortex (M2). Additionally, we also identified a pain-related neural circuit involving brain regions of the anterior cingulate cortex (ACC) and mediodorsal nucleus (MD). Interestingly, the spatiotemporal activation mapping also allowed us to identify subregions with different DIANA response times within the same functional region (e.g., VPL, POm, S1FL, and S2). Our study highlights the potential of DIANA fMRI to advance our understanding of sensory information processing throughout the brain and to provide insight into the spatiotemporal dynamics of brain networks at the level of neural circuits.
- Open Access
Responses to membrane potential-modulating ionic solutions measured by magnetic resonance imaging of cultured cells and in vivo rat cortex
Membrane potential plays a crucial role in various cellular functions. However, existing techniques for measuring membrane potential are often invasive or have limited recording depth. In contrast, magnetic resonance imaging (MRI) offers noninvasive imaging with desirable spatial resolution over large areas. This study investigates the feasibility of utilizing MRI to detect responses of cultured cells and in vivo rat cortex to membrane potential-modulating ionic solutions by measuring magnetic resonance parameters. Our findings reveal that depolarizing (or hyperpolarizing) ionic solutions increase (or decrease) the T 2 relaxation time, while the ratio of bound to free water proton shows the opposite trend. These findings also suggest a potential approach to noninvasively detect changes in membrane potential using MRI.
Open AccessResponses to membrane potential-modulating ionic solutions measured by magnetic resonance imaging of cultured cells and in vivo rat cortex
Membrane potential plays a crucial role in various cellular functions. However, existing techniques for measuring membrane potential are often invasive or have limited recording depth. In contrast, magnetic resonance imaging (MRI) offers noninvasive imaging with desirable spatial resolution over large areas. This study investigates the feasibility of utilizing MRI to detect responses of cultured cells and in vivo rat cortex to membrane potential-modulating ionic solutions by measuring magnetic resonance parameters. Our findings reveal that depolarizing (or hyperpolarizing) ionic solutions increase (or decrease) the T 2 relaxation time, while the ratio of bound to free water proton shows the opposite trend. These findings also suggest a potential approach to noninvasively detect changes in membrane potential using MRI.
- Retracted
- 14 October 2022
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 378 (6616) , 160-168
RETRACTED: In vivo direct imaging of neuronal activity at high temporospatial resolution
There has been a long-standing demand for noninvasive neuroimaging methods that can detect neuronal activity at both high temporal and high spatial resolution. We present a two-dimensional fast line-scan approach that enables direct imaging of neuronal activity with millisecond precision while retaining the high spatial resolution of magnetic resonance imaging (MRI). This approach was demonstrated through in vivo mouse brain imaging at 9.4 tesla during electrical whisker-pad stimulation. In vivo spike recording and optogenetics confirmed the high correlation of the observed MRI signal with neural activity. It also captured the sequential and laminar-specific propagation of neuronal activity along the thalamocortical pathway. This high-resolution, direct imaging of neuronal activity will open up new avenues in brain science by providing a deeper understanding of the brain’s functional organization, including the temporospatial dynamics of neural networks.
- 14 October 2022
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 378 (6616) , 160-168
RetractedRETRACTED: In vivo direct imaging of neuronal activity at high temporospatial resolution
There has been a long-standing demand for noninvasive neuroimaging methods that can detect neuronal activity at both high temporal and high spatial resolution. We present a two-dimensional fast line-scan approach that enables direct imaging of neuronal activity with millisecond precision while retaining the high spatial resolution of magnetic resonance imaging (MRI). This approach was demonstrated through in vivo mouse brain imaging at 9.4 tesla during electrical whisker-pad stimulation. In vivo spike recording and optogenetics confirmed the high correlation of the observed MRI signal with neural activity. It also captured the sequential and laminar-specific propagation of neuronal activity along the thalamocortical pathway. This high-resolution, direct imaging of neuronal activity will open up new avenues in brain science by providing a deeper understanding of the brain’s functional organization, including the temporospatial dynamics of neural networks.
- Open Access
In vivo direct imaging of neuronal activity at high temporo-spatial resolution
There has been a longstanding demand for noninvasive neuroimaging methods capable of detecting neuronal activity at both high temporal and spatial resolution. Here, we propose a novel method that enables Direct Imaging of Neuronal Activity for functional MRI (termed DIANA-fMRI) that can dynamically image spiking activity in milliseconds precision, while retaining the original benefit of high spatial resolution of MRI. DIANA-fMRI was demonstrated through in vivo mice brain imaging at 9.4 T applying electrical whisker-pad stimulation, directly imaging the spiking activity as well as capturing its sequential propagation along the thalamocortical pathway, as further confirmed through in vivo spike recording and optogenetics. DIANA-fMRI will open up new avenues in brain science by providing a deeper understanding of the brain’s functional organization including neural networks.
Open AccessIn vivo direct imaging of neuronal activity at high temporo-spatial resolution
There has been a longstanding demand for noninvasive neuroimaging methods capable of detecting neuronal activity at both high temporal and spatial resolution. Here, we propose a novel method that enables Direct Imaging of Neuronal Activity for functional MRI (termed DIANA-fMRI) that can dynamically image spiking activity in milliseconds precision, while retaining the original benefit of high spatial resolution of MRI. DIANA-fMRI was demonstrated through in vivo mice brain imaging at 9.4 T applying electrical whisker-pad stimulation, directly imaging the spiking activity as well as capturing its sequential propagation along the thalamocortical pathway, as further confirmed through in vivo spike recording and optogenetics. DIANA-fMRI will open up new avenues in brain science by providing a deeper understanding of the brain’s functional organization including neural networks.
- 3 April 2019
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (16) , 14567-14575
Fully Stretchable Capillary Microfluidics-Integrated Nanoporous Gold Electrochemical Sensor for Wearable Continuous Glucose Monitoring
Biosensor systems for wearable continuous monitoring are desired to be developed into conformal patch platforms. However, developing such patches is very challenging owing to the difficulty of imparting materials and components with both high stretchability and high performance. Herein we report a fully stretchable microfluidics-integrated glucose sensor patch comprised of an omnidirectionally stretchable nanoporous gold (NPG) electrochemical biosensor and a stretchable passive microfluidic device. A highly electrocatalytic NPG electrode was formed on a stress-absorbing 3D micropatterned polydimethylsiloxane (PDMS) substrate to confer mechanical stretchability, high sensitivity, and durability in non-enzymatic glucose detection. A thin, stretchable, and tough microfluidic device was made by embedding stretchable cotton fabric as a capillary into a thin polyurethane nanofiber–reinforced PDMS channel, enabling collection and passive, accurate delivery of sweat from skin to the electrode surface, with excellent replacement capability. The integrated glucose sensor patch demonstrated excellent ability to continuously and accurately monitor sweat glucose level.
- 3 April 2019
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (16) , 14567-14575
Fully Stretchable Capillary Microfluidics-Integrated Nanoporous Gold Electrochemical Sensor for Wearable Continuous Glucose Monitoring
Biosensor systems for wearable continuous monitoring are desired to be developed into conformal patch platforms. However, developing such patches is very challenging owing to the difficulty of imparting materials and components with both high stretchability and high performance. Herein we report a fully stretchable microfluidics-integrated glucose sensor patch comprised of an omnidirectionally stretchable nanoporous gold (NPG) electrochemical biosensor and a stretchable passive microfluidic device. A highly electrocatalytic NPG electrode was formed on a stress-absorbing 3D micropatterned polydimethylsiloxane (PDMS) substrate to confer mechanical stretchability, high sensitivity, and durability in non-enzymatic glucose detection. A thin, stretchable, and tough microfluidic device was made by embedding stretchable cotton fabric as a capillary into a thin polyurethane nanofiber–reinforced PDMS channel, enabling collection and passive, accurate delivery of sweat from skin to the electrode surface, with excellent replacement capability. The integrated glucose sensor patch demonstrated excellent ability to continuously and accurately monitor sweat glucose level.