Johannes M.M. van Lith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Johannes M.M. van Lith has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
- Jan G. Nijhuis
School for Oncology and Developmental Biology (GROW), Department of Obstetrics and Gynecology, Maastricht University Medical Centre, Maastricht, Netherlands
3 shared publications - Anneke Kwee
Department of Obstetrics and Gynecology, University Medical Center Utrecht, Utrecht, The Netherlands
2 shared publications - Ben Willem Mol
Department of Obstetrics and Gynaecology Monash University Clayton Victoria Australia
2 shared publications - Dacia D. C. A. Henriquez
Department of Clinical Epidemiology Leiden University Medical Centre Leiden the Netherlands
2 shared publications - Gerard H. A. Visser
Department of Obstetrics, University Medical Center, Utrecht, The Netherlands
2 shared publications - Gouke J. Bonsel
Department of Orthopaedics and Sports Medicine, Erasmus MC, Rotterdam, The Netherlands.
2 shared publications
Latest Publications
- Open Access
- 1 January 2024
- Published by XMLink in Yonsei Medical Journal
- Vol. 65 (4) , 202-209
Evidence of Placental Villous Inflammation and Apoptosis in Third-Trimester Symptomatic SARS-CoV-2 Maternal Infection
Wardhana MP, et al. Yonsei Med J. 2024 Apr;65(4):202-209. https://doi.org/10.3349/ymj.2023.0309
- 1 January 2024
- Published by XMLink in Yonsei Medical Journal
- Vol. 65 (4) , 202-209
Open AccessEvidence of Placental Villous Inflammation and Apoptosis in Third-Trimester Symptomatic SARS-CoV-2 Maternal Infection
Wardhana MP, et al. Yonsei Med J. 2024 Apr;65(4):202-209. https://doi.org/10.3349/ymj.2023.0309
- Open Access
- 6 September 2023
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 36 (2) , 2251076
Prophylactic radiologic interventions to reduce postpartum hemorrhage in women with risk factors for placenta accreta spectrum disorder: a nationwide cohort study
To quantify the association between prophylactic radiologic interventions and perioperative blood loss in women with risk factors for placenta accreta spectrum disorder (PAS). We conducted a retrospective nationwide cohort study of women with risk factors for placenta accreta spectrum disorder who underwent planned cesarean section in 69 Dutch hospitals between 2008 and 2013. All women had two risk factors for PAS: placenta previa/anterior low-lying placenta and a history of cesarean section(s). Women with and without ultrasonographic signs of PAS were studied as two separate groups. We compared the total blood loss of women with prophylactic radiologic interventions, defined as preoperative placement of balloon catheters or sheaths in the internal iliac or uterine arteries, with that of a control group consisting of women without prophylactic radiologic interventions using multivariable regression. We evaluated maternal morbidity by the number of red blood cell (RBC) units transfused within 24 h following childbirth (categories: 0, 1-3, >4), duration of hospital admission, and need for intensive care unit (ICU) admission. A total of 350 women with placenta previa/anterior low-lying placenta and history of cesarean section(s) were included: 289 with normal ultrasonography, of whom 21 received prophylactic radiologic intervention, and 61 had abnormal ultrasonography, of whom 22 received prophylactic intervention. Among women with normal ultrasonography without prophylactic intervention (n = 268), the median blood loss was 725 mL (interquartile range (IQR) 500-1500) vs. 1000 mL (IQR 550-1750) in women with intervention (n = 21); the adjusted difference in blood loss was 9 mL (95% confidence interval (CI) -315-513), p = .97). Among women with abnormal ultrasonography, those without prophylactic intervention (n = 39) had a median blood loss of 2500 mL (IQR 1200-5000) vs. 1750 mL (IQR 775-4000) in women with intervention (n = 22); the adjusted difference in blood loss was -1141 mL (95% CI -1694- -219, p = .02). Results of outcomes on maternal morbidity were comparable among women with and without prophylactic intervention. These findings suggest that prophylactic radiologic interventions prior to planned cesarean section may help to limit perioperative blood loss in women with clear signs of placenta accreta spectrum disorder on ultrasonography, but there was no evidence of a difference within the subgroup without such ultrasonographic signs. The use of these interventions should be discussed in a multidisciplinary shared decision-making process, including discussions of potential benefits and possible complications. Netherlands Trial Registry, https://onderzoekmetmensen.nl/en/trial/28238, identifier NL4210 (NTR4363).
- 6 September 2023
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 36 (2) , 2251076
Open AccessProphylactic radiologic interventions to reduce postpartum hemorrhage in women with risk factors for placenta accreta spectrum disorder: a nationwide cohort study
To quantify the association between prophylactic radiologic interventions and perioperative blood loss in women with risk factors for placenta accreta spectrum disorder (PAS). We conducted a retrospective nationwide cohort study of women with risk factors for placenta accreta spectrum disorder who underwent planned cesarean section in 69 Dutch hospitals between 2008 and 2013. All women had two risk factors for PAS: placenta previa/anterior low-lying placenta and a history of cesarean section(s). Women with and without ultrasonographic signs of PAS were studied as two separate groups. We compared the total blood loss of women with prophylactic radiologic interventions, defined as preoperative placement of balloon catheters or sheaths in the internal iliac or uterine arteries, with that of a control group consisting of women without prophylactic radiologic interventions using multivariable regression. We evaluated maternal morbidity by the number of red blood cell (RBC) units transfused within 24 h following childbirth (categories: 0, 1-3, >4), duration of hospital admission, and need for intensive care unit (ICU) admission. A total of 350 women with placenta previa/anterior low-lying placenta and history of cesarean section(s) were included: 289 with normal ultrasonography, of whom 21 received prophylactic radiologic intervention, and 61 had abnormal ultrasonography, of whom 22 received prophylactic intervention. Among women with normal ultrasonography without prophylactic intervention (n = 268), the median blood loss was 725 mL (interquartile range (IQR) 500-1500) vs. 1000 mL (IQR 550-1750) in women with intervention (n = 21); the adjusted difference in blood loss was 9 mL (95% confidence interval (CI) -315-513), p = .97). Among women with abnormal ultrasonography, those without prophylactic intervention (n = 39) had a median blood loss of 2500 mL (IQR 1200-5000) vs. 1750 mL (IQR 775-4000) in women with intervention (n = 22); the adjusted difference in blood loss was -1141 mL (95% CI -1694- -219, p = .02). Results of outcomes on maternal morbidity were comparable among women with and without prophylactic intervention. These findings suggest that prophylactic radiologic interventions prior to planned cesarean section may help to limit perioperative blood loss in women with clear signs of placenta accreta spectrum disorder on ultrasonography, but there was no evidence of a difference within the subgroup without such ultrasonographic signs. The use of these interventions should be discussed in a multidisciplinary shared decision-making process, including discussions of potential benefits and possible complications. Netherlands Trial Registry, https://onderzoekmetmensen.nl/en/trial/28238, identifier NL4210 (NTR4363).
- Open Access
- 9 February 2022
- Published by Elsevier in F&S Reviews
- Vol. 3 (2) , 136-145
Prognosis in unexplained recurrent pregnancy loss: a systematic review and quality assessment of current clinical prediction models
- 9 February 2022
- Published by Elsevier in F&S Reviews
- Vol. 3 (2) , 136-145
Open AccessPrognosis in unexplained recurrent pregnancy loss: a systematic review and quality assessment of current clinical prediction models
- Open Access
- 21 May 2021
- Published by Wiley in Echocardiography
- Vol. 38 (6) , 974-981
Assessment of human fetal cardiac autonomic nervous system development using color tissue Doppler imaging
Objectives: Functional development of the fetal cardiac autonomic nervous system (cANS) plays a key role in fetal maturation and can be assessed through fetal heart rate variability (fHRV)‐analysis, with each HRV parameter representing different aspects of cANS activity. Current available techniques, however, are unable to assess the fHRV parameters accurately throughout the whole pregnancy. This study aims to test the feasibility of color tissue Doppler imaging (cTDI) as a new ultrasound technique for HRV analysis. Secondly, we explored time trends of fHRV parameters using this technique.Methods: 18 healthy singleton fetuses were examined sequentially every 8 weeks from 10 weeks GA onwards. From each examination, 3 cTDI recordings of the four‐chamber view of 10 seconds were retrieved to determine accurate beat‐to‐beat intervals. The fHRV parameters SDNN, RMSSD, SDNN/RMSSD, and pNN10, each representing different functional aspects of the cANS, were measured, and time trends during pregnancy were explored using spline functions within a linear mixed‐effects model.Results: In total, 77% (95% Cl 66–87%) of examinations were feasible for fHRV analysis from the first trimester onwards, which is a great improvement compared to other techniques. The technique is able to determine different maturation rates of the fHRV parameters, showing that cANS function, presumably parasympathetic activity, establishes around 20 weeks GA and matures rapidly until 30 weeks GA.Conclusions: This is the first study able to assess cANS function through fHRV analysis from the first trimester onwards. The use of cTDI to determine beat‐to‐beat intervals seems feasible in just 3 clips of 10 seconds, which holds promise for future clinical use in assessing fetal well‐being.
- 21 May 2021
- Published by Wiley in Echocardiography
- Vol. 38 (6) , 974-981
Open AccessAssessment of human fetal cardiac autonomic nervous system development using color tissue Doppler imaging
Objectives: Functional development of the fetal cardiac autonomic nervous system (cANS) plays a key role in fetal maturation and can be assessed through fetal heart rate variability (fHRV)‐analysis, with each HRV parameter representing different aspects of cANS activity. Current available techniques, however, are unable to assess the fHRV parameters accurately throughout the whole pregnancy. This study aims to test the feasibility of color tissue Doppler imaging (cTDI) as a new ultrasound technique for HRV analysis. Secondly, we explored time trends of fHRV parameters using this technique.Methods: 18 healthy singleton fetuses were examined sequentially every 8 weeks from 10 weeks GA onwards. From each examination, 3 cTDI recordings of the four‐chamber view of 10 seconds were retrieved to determine accurate beat‐to‐beat intervals. The fHRV parameters SDNN, RMSSD, SDNN/RMSSD, and pNN10, each representing different functional aspects of the cANS, were measured, and time trends during pregnancy were explored using spline functions within a linear mixed‐effects model.Results: In total, 77% (95% Cl 66–87%) of examinations were feasible for fHRV analysis from the first trimester onwards, which is a great improvement compared to other techniques. The technique is able to determine different maturation rates of the fHRV parameters, showing that cANS function, presumably parasympathetic activity, establishes around 20 weeks GA and matures rapidly until 30 weeks GA.Conclusions: This is the first study able to assess cANS function through fHRV analysis from the first trimester onwards. The use of cTDI to determine beat‐to‐beat intervals seems feasible in just 3 clips of 10 seconds, which holds promise for future clinical use in assessing fetal well‐being.
- Open Access
- 17 May 2021
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 100 (9) , 1656-1664
Clinical value of early viscoelastometric point‐of‐care testing during postpartum hemorrhage for the prediction of severity of bleeding: A multicenter prospective cohort study in the Netherlands
Introduction: To evaluate rotational fibrin‐based thromboelastometry (ROTEM® FIBTEM) with amplitude of clot firmness at 5 min (A5) as an early point‐of‐care parameter for predicting progression to severe postpartum hemorrhage, and compare its predictive value with that of fibrinogen.Material and methods: Prospective cohort study in the Netherlands including women with 800–1500 ml of blood loss within 24 h following birth. Blood loss was quantitatively measured by weighing blood‐soaked items and using a fluid collector bag in the operating room. Both FIBTEM A5 values and fibrinogen concentrations (Clauss method) were measured between 800 and 1500 ml of blood loss. Predictive accuracy of both biomarkers for the progression to severe postpartum hemorrhage was measured by area under the receiver operating curves (AUC). Severe postpartum hemorrhage was defined as a composite endpoint of (1) total blood loss >2000 ml, (2) transfusion of ≥4 packed cells, and/or (3) need for an invasive intervention to cease bleeding.Results: Of the 391 women included, 72 (18%) developed severe postpartum hemorrhage. Median (IQR) volume of blood loss at blood sampling was 1100 ml (1000–1300) with a median (interquartile range [IQR]) fibrinogen concentration of 3.9 g/L (3.4–4.6) and FIBTEM A5 value of 17 mm (13–20). The AUC for progression to severe postpartum hemorrhage was 0.53 (95% confidence interval [CI] 0.46–0.61) for FIBTEM A5 and 0.58 (95% CI 0.50–0.65) for fibrinogen. Positive predictive values for progression to severe postpartum hemorrhage for FIBTEM A5 ≤12 mm was 22.5% (95% CI 14–33) and 50% (95% CI 25–75) for fibrinogen ≤2 g/L.Conclusions: The predictive value of FIBTEM A5 compared to fibrinogen concentrations measured between 800 and 1500 ml of blood loss following childbirth was poor to discriminate between women with and without progression towards severe postpartum hemorrhage.
- 17 May 2021
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 100 (9) , 1656-1664
Open AccessClinical value of early viscoelastometric point‐of‐care testing during postpartum hemorrhage for the prediction of severity of bleeding: A multicenter prospective cohort study in the Netherlands
Introduction: To evaluate rotational fibrin‐based thromboelastometry (ROTEM® FIBTEM) with amplitude of clot firmness at 5 min (A5) as an early point‐of‐care parameter for predicting progression to severe postpartum hemorrhage, and compare its predictive value with that of fibrinogen.Material and methods: Prospective cohort study in the Netherlands including women with 800–1500 ml of blood loss within 24 h following birth. Blood loss was quantitatively measured by weighing blood‐soaked items and using a fluid collector bag in the operating room. Both FIBTEM A5 values and fibrinogen concentrations (Clauss method) were measured between 800 and 1500 ml of blood loss. Predictive accuracy of both biomarkers for the progression to severe postpartum hemorrhage was measured by area under the receiver operating curves (AUC). Severe postpartum hemorrhage was defined as a composite endpoint of (1) total blood loss >2000 ml, (2) transfusion of ≥4 packed cells, and/or (3) need for an invasive intervention to cease bleeding.Results: Of the 391 women included, 72 (18%) developed severe postpartum hemorrhage. Median (IQR) volume of blood loss at blood sampling was 1100 ml (1000–1300) with a median (interquartile range [IQR]) fibrinogen concentration of 3.9 g/L (3.4–4.6) and FIBTEM A5 value of 17 mm (13–20). The AUC for progression to severe postpartum hemorrhage was 0.53 (95% confidence interval [CI] 0.46–0.61) for FIBTEM A5 and 0.58 (95% CI 0.50–0.65) for fibrinogen. Positive predictive values for progression to severe postpartum hemorrhage for FIBTEM A5 ≤12 mm was 22.5% (95% CI 14–33) and 50% (95% CI 25–75) for fibrinogen ≤2 g/L.Conclusions: The predictive value of FIBTEM A5 compared to fibrinogen concentrations measured between 800 and 1500 ml of blood loss following childbirth was poor to discriminate between women with and without progression towards severe postpartum hemorrhage.
- Open Access
- 13 March 2019
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 55 (2) , 217-225
Impact of extracardiac pathology on head growth in fetuses with congenital heart defect
Objective: Neurodevelopmental delay is frequently encountered in children with a congenital heart defect (CHD). Fetuses with major CHD have a smaller head circumference (HC), irrespective of altered cerebral flow or brain oxygenation. This cohort study compared head growth in cases with isolated vs those with non‐isolated CHD to evaluate the effect of additional pathology on head size in these fetuses.Method: All CHD cases diagnosed prenatally in the period January 2002–July 2014 were selected from our regional registry, PRECOR. Cases of multiple pregnancy, and those affected by maternal diabetes, severe fetal structural brain anomalies or functional CHD were excluded. Subjects were divided into groups according to whether the CHD was isolated, and the non‐isolated group was subdivided into three groups: cases with genetic anomaly, extracardiac malformation or placental pathology. In both isolated and non‐isolated CHD groups, CHDs were also grouped according to their potential effect on aortic flow and oxygen saturation. Mean HC Z‐scores at 20 weeks and increase or decrease (Δ) of HC Z‐scores over the course of pregnancy were compared between isolated and non‐isolated groups, using mixed linear regression models.Results: Included were 916 cases of CHD diagnosed prenatally, of which 378 (41.3%) were non‐isolated (37 with placental pathology, 217 with genetic anomaly and 124 with extracardiac malformation). At 20 weeks, non‐isolated cases had significantly lower HC Z‐scores than did isolated cases (Z‐score = –0.70 vs –0.03; P < 0.001) and head growth over the course of pregnancy showed a larger decrease in this group (Δ HC Z‐score = –0.03 vs –0.01 per week; P = 0.01). Cases with placental pathology had the lowest HC Z‐score at 20 weeks (Z‐score = –1.29) and the largest decrease in head growth (Δ HC Z‐score = –0.06 per week). In CHD subjects with a genetic diagnosis (Z‐score = –0.73; Δ HC Z‐score = –0.04 per week) and in those with an extracardiac malformation (Z‐score = –0.49; Δ HC Z‐score = –0.02 per week), HC Z‐scores were also lower compared with those in subjects with isolated CHD. CHDs that result in low oxygenation or flow to the brain were present more frequently in isolated than in non‐isolated cases.Conclusions: Smaller HC in fetuses with CHD appears to be associated strongly with additional pathology. Placental pathology and genetic anomaly in particular seem to be important contributors to restricted head growth. This effect appears to be irrespective of altered hemodynamics caused by the CHD. Previously reported smaller HC in CHD should, in our opinion, be attributed to additional pathology. Neurodevelopment studies in infants with CHD should, therefore, always differentiate between isolated and non‐isolated cases. © 2019 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.
- 13 March 2019
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 55 (2) , 217-225
Open AccessImpact of extracardiac pathology on head growth in fetuses with congenital heart defect
Objective: Neurodevelopmental delay is frequently encountered in children with a congenital heart defect (CHD). Fetuses with major CHD have a smaller head circumference (HC), irrespective of altered cerebral flow or brain oxygenation. This cohort study compared head growth in cases with isolated vs those with non‐isolated CHD to evaluate the effect of additional pathology on head size in these fetuses.Method: All CHD cases diagnosed prenatally in the period January 2002–July 2014 were selected from our regional registry, PRECOR. Cases of multiple pregnancy, and those affected by maternal diabetes, severe fetal structural brain anomalies or functional CHD were excluded. Subjects were divided into groups according to whether the CHD was isolated, and the non‐isolated group was subdivided into three groups: cases with genetic anomaly, extracardiac malformation or placental pathology. In both isolated and non‐isolated CHD groups, CHDs were also grouped according to their potential effect on aortic flow and oxygen saturation. Mean HC Z‐scores at 20 weeks and increase or decrease (Δ) of HC Z‐scores over the course of pregnancy were compared between isolated and non‐isolated groups, using mixed linear regression models.Results: Included were 916 cases of CHD diagnosed prenatally, of which 378 (41.3%) were non‐isolated (37 with placental pathology, 217 with genetic anomaly and 124 with extracardiac malformation). At 20 weeks, non‐isolated cases had significantly lower HC Z‐scores than did isolated cases (Z‐score = –0.70 vs –0.03; P < 0.001) and head growth over the course of pregnancy showed a larger decrease in this group (Δ HC Z‐score = –0.03 vs –0.01 per week; P = 0.01). Cases with placental pathology had the lowest HC Z‐score at 20 weeks (Z‐score = –1.29) and the largest decrease in head growth (Δ HC Z‐score = –0.06 per week). In CHD subjects with a genetic diagnosis (Z‐score = –0.73; Δ HC Z‐score = –0.04 per week) and in those with an extracardiac malformation (Z‐score = –0.49; Δ HC Z‐score = –0.02 per week), HC Z‐scores were also lower compared with those in subjects with isolated CHD. CHDs that result in low oxygenation or flow to the brain were present more frequently in isolated than in non‐isolated cases.Conclusions: Smaller HC in fetuses with CHD appears to be associated strongly with additional pathology. Placental pathology and genetic anomaly in particular seem to be important contributors to restricted head growth. This effect appears to be irrespective of altered hemodynamics caused by the CHD. Previously reported smaller HC in CHD should, in our opinion, be attributed to additional pathology. Neurodevelopment studies in infants with CHD should, therefore, always differentiate between isolated and non‐isolated cases. © 2019 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.
- Open Access
- 27 April 2012
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 91 (7) , 830-837
Identification of cases with adverse neonatal outcome monitored by cardiotocography versus ST analysis: secondary analysis of a randomized trial
Objective. To evaluate whether correct adherence to clinical guidelines might have led to prevention of cases with adverse neonatal outcome. Design. Secondary analysis of cases with adverse outcome in a multicenter randomized clinical trial. Setting. Nine Dutch hospitals. Population. Pregnant women with a term singleton fetus in cephalic position. Methods. Data were obtained from a randomized trial that compared monitoring by STAN® (index group) with cardiotocography (control group). In both trial arms, three observers independently assessed the fetal surveillance results in all cases with adverse neonatal outcome, to determine whether an indication for intervention was present, based on current clinical guidelines. Main outcome measures. Adverse neonatal outcome cases fulfilled one or more of the following criteria: (i) metabolic acidosis in umbilical cord artery (pH < 7.05 and base deficit in extracellular fluid >12 mmol/L); (ii) umbilical cord artery pH < 7.00; (iii) perinatal death; and/or (iv) signs of moderate or severe hypoxic ischemic encephalopathy. Results. We studied 5681 women, of whom 61 (1.1%) had an adverse outcome (26 index; 35 control). In these women, the number of performed operative deliveries for fetal distress was 18 (69.2%) and 16 (45.7%), respectively. Reassessment of all 61 cases showed that there was a fetal indication to intervene in 23 (88.5%) and 19 (57.6%) cases, respectively. In 13 (50.0%) vs. 11 (33.3%) cases, respectively, this indication occurred more than 20 min before the time of delivery, meaning that these adverse outcomes could possibly have been prevented. Conclusions. In our trial, more strict adherence to clinical guidelines could have led to additional identification and prevention of adverse outcome.
- 27 April 2012
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 91 (7) , 830-837
Open AccessIdentification of cases with adverse neonatal outcome monitored by cardiotocography versus ST analysis: secondary analysis of a randomized trial
Objective. To evaluate whether correct adherence to clinical guidelines might have led to prevention of cases with adverse neonatal outcome. Design. Secondary analysis of cases with adverse outcome in a multicenter randomized clinical trial. Setting. Nine Dutch hospitals. Population. Pregnant women with a term singleton fetus in cephalic position. Methods. Data were obtained from a randomized trial that compared monitoring by STAN® (index group) with cardiotocography (control group). In both trial arms, three observers independently assessed the fetal surveillance results in all cases with adverse neonatal outcome, to determine whether an indication for intervention was present, based on current clinical guidelines. Main outcome measures. Adverse neonatal outcome cases fulfilled one or more of the following criteria: (i) metabolic acidosis in umbilical cord artery (pH < 7.05 and base deficit in extracellular fluid >12 mmol/L); (ii) umbilical cord artery pH < 7.00; (iii) perinatal death; and/or (iv) signs of moderate or severe hypoxic ischemic encephalopathy. Results. We studied 5681 women, of whom 61 (1.1%) had an adverse outcome (26 index; 35 control). In these women, the number of performed operative deliveries for fetal distress was 18 (69.2%) and 16 (45.7%), respectively. Reassessment of all 61 cases showed that there was a fetal indication to intervene in 23 (88.5%) and 19 (57.6%) cases, respectively. In 13 (50.0%) vs. 11 (33.3%) cases, respectively, this indication occurred more than 20 min before the time of delivery, meaning that these adverse outcomes could possibly have been prevented. Conclusions. In our trial, more strict adherence to clinical guidelines could have led to additional identification and prevention of adverse outcome.
- Open Access
- 20 May 2008
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 8 (1) , 18
Multiplex ligation-dependent probe amplification versus karyotyping in prenatal diagnosis: the M.A.K.E. study
In the past 30 years karyotyping was the gold standard for prenatal diagnosis of chromosomal aberrations in the fetus. Traditional karyotyping (TKT) has a high accuracy and reliability. However, it is labor intensive, the results take 14–21 days, the costs are high and unwanted findings such as abnormalities with unknown clinical relevance are not uncommon. These disadvantages challenged the practice of karyotyping. Multiplex ligation-dependent probe amplification (MLPA) is a new molecular genetic technique in prenatal diagnosis. Previous preclinical evidence suggests equivalence of MLPA and traditional karyotyping (TKT) regarding test performance. The proposed study is a multicentre diagnostic substitute study among pregnant women, who choose to have amniocentesis for the indication advanced maternal age and/or increased risk following prenatal screening test. In all subjects, both MLPA and karyotyping will be performed on the amniotic fluid sample. The primary outcome is diagnostic accuracy. Secondary outcomes will be maternal quality of life, women's preferences and costs. Analysis will be intention to treat and per protocol analysis. Quality of life analysis will be carried out within the study population. The study aims to include 4500 women. The study results are expected to help decide whether MLPA can replace traditional karyotyping for 'low-risk' pregnancies in terms of diagnostic accuracy, quality of life and women's preferences. This will be the first clinical study to report on all relevant aspects of the potential replacement. The protocol is registered in the clinical trial register number ISRCTN47252164
- 20 May 2008
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 8 (1) , 18
Open AccessMultiplex ligation-dependent probe amplification versus karyotyping in prenatal diagnosis: the M.A.K.E. study
In the past 30 years karyotyping was the gold standard for prenatal diagnosis of chromosomal aberrations in the fetus. Traditional karyotyping (TKT) has a high accuracy and reliability. However, it is labor intensive, the results take 14–21 days, the costs are high and unwanted findings such as abnormalities with unknown clinical relevance are not uncommon. These disadvantages challenged the practice of karyotyping. Multiplex ligation-dependent probe amplification (MLPA) is a new molecular genetic technique in prenatal diagnosis. Previous preclinical evidence suggests equivalence of MLPA and traditional karyotyping (TKT) regarding test performance. The proposed study is a multicentre diagnostic substitute study among pregnant women, who choose to have amniocentesis for the indication advanced maternal age and/or increased risk following prenatal screening test. In all subjects, both MLPA and karyotyping will be performed on the amniotic fluid sample. The primary outcome is diagnostic accuracy. Secondary outcomes will be maternal quality of life, women's preferences and costs. Analysis will be intention to treat and per protocol analysis. Quality of life analysis will be carried out within the study population. The study aims to include 4500 women. The study results are expected to help decide whether MLPA can replace traditional karyotyping for 'low-risk' pregnancies in terms of diagnostic accuracy, quality of life and women's preferences. This will be the first clinical study to report on all relevant aspects of the potential replacement. The protocol is registered in the clinical trial register number ISRCTN47252164
- 1 April 2008
- Published by Elsevier in European Journal of Obstetrics & Gynecology and Reproductive Biology
- Vol. 137 (2) , 141-145
Design and evaluation of a regional perinatal audit
- 1 April 2008
- Published by Elsevier in European Journal of Obstetrics & Gynecology and Reproductive Biology
- Vol. 137 (2) , 141-145
Design and evaluation of a regional perinatal audit
- Open Access
- 26 July 2007
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 7 (1) , 13
A randomised clinical trial on cardiotocography plus fetal blood sampling versus cardiotocography plus ST-analysis of the fetal electrocardiogram (STAN®) for intrapartum monitoring
Cardiotocography (CTG) is worldwide the method for fetal surveillance during labour. However, CTG alone shows many false positive test results and without fetal blood sampling (FBS), it results in an increase in operative deliveries without improvement of fetal outcome. FBS requires additional expertise, is invasive and has often to be repeated during labour. Two clinical trials have shown that a combination of CTG and ST-analysis of the fetal electrocardiogram (ECG) reduces the rates of metabolic acidosis and instrumental delivery. However, in both trials FBS was still performed in the ST-analysis arm, and it is therefore still unknown if the observed results were indeed due to the ST-analysis or to the use of FBS in combination with ST-analysis.
- 26 July 2007
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 7 (1) , 13
Open AccessA randomised clinical trial on cardiotocography plus fetal blood sampling versus cardiotocography plus ST-analysis of the fetal electrocardiogram (STAN®) for intrapartum monitoring
Cardiotocography (CTG) is worldwide the method for fetal surveillance during labour. However, CTG alone shows many false positive test results and without fetal blood sampling (FBS), it results in an increase in operative deliveries without improvement of fetal outcome. FBS requires additional expertise, is invasive and has often to be repeated during labour. Two clinical trials have shown that a combination of CTG and ST-analysis of the fetal electrocardiogram (ECG) reduces the rates of metabolic acidosis and instrumental delivery. However, in both trials FBS was still performed in the ST-analysis arm, and it is therefore still unknown if the observed results were indeed due to the ST-analysis or to the use of FBS in combination with ST-analysis.