Kenneth N. Aycock

Kenneth N. Aycock

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kenneth N. Aycock has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    High-Frequency Irreversible Electroporation Alters Proteomic Profiles and Tropism of Small Tumor-Derived Extracellular Vesicles to Promote Immune Cell Infiltration

    by Kelsey R. Murphy, Kenneth N. Aycock, Spencer Marsh, Liping Yang, Jonathan Hinckley, Aubrie Selmek, Robert Gourdie, Shay Bracha, Rafael V. Davalos, John H. Rossmeisl, et al.

    High-frequency irreversible electroporation (H-FIRE) is a nonthermal tumor ablation technique that disrupts the blood–brain barrier (BBB) in a focal and reversible manner. However, the mechanisms underlying this disruption remain poorly understood, particularly the role of small tumor-derived extracellular vesicles (sTDEVs) released from ablated tumor cells. In this study, we investigate the proteomic and functional alterations of sTDEVs released from F98 glioma and LL/2 Lewis lung carcinoma cells following H-FIRE ablation. Mass spectrometry analysis revealed 108 unique proteins in sTDEVs derived from ablative doses of H-FIRE, which are capable of disrupting the BBB in an in vitro model. Proteomic analysis of TDEVs highlights key changes in pathways related to integrin signaling, Platelet-derived growth factor receptor (PDGFR) signaling, and ubiquitination, which may underline their interactions with brain endothelial cells. These “disruptive” sTDEVs exhibit enhanced tropism for cerebral endothelial cells both in vitro and in vivo, where they persist in the brain longer than sTDEVs released after non-ablative H-FIRE doses. Notably, when introduced into a healthy Fischer rat model, disruptive sTDEVs are associated with increased recruitment of Iba1+ immune cells, suggesting a potential role in modulating post-ablation immune responses. However, despite their altered protein composition, these vesicles do not directly increase BBB permeability in vivo. This study is the first to demonstrate that electroporation-based tumor ablation significantly alters the composition and functionality of tumor-derived extracellular vesicles, potentially influencing the tumor microenvironment post-ablation. These findings have important implications for developing multimodal treatment strategies that combine H-FIRE with systemic therapies to enhance efficacy while managing the peritumoral microenvironment.


  • Toward Large Ablations With Single-Needle High-Frequency Irreversible Electroporation In Vivo

    by Kenneth N. Aycock, Sabrina N. Campelo, Zaid S. Salameh, Joshua M. K. Davis, David A. Iannitti, Iain H. McKillop, Rafael V. Davalos

    Irreversible electroporation (IRE) is a minimally thermal tissue ablation modality used to treat solid tumors adjacent to critical structures. Widespread clinical adoption of IRE has been limited due to complicated anesthetic management requirements and technical demands associated with placing multiple needle electrodes in anatomically challenging environments. High-frequency irreversible electroporation (H-FIRE) delivered using a novel single-insertion bipolar probe system could potentially overcome these limitations, but ablation volumes have remained small using this approach. While H-FIRE is minimally thermal in mode of action, high voltages or multiple pulse trains can lead to unwanted Joule heating. In this work, we improve the H-FIRE waveform design to increase the safe operating voltage using a single-insertion bipolar probe before electrical arcing occurs. By uniformly increasing interphase ($d_{1}$) and interpulse ($d_{2}$) delays, we achieved higher maximum operating voltages for all pulse lengths. Additionally, increasing pulse length led to higher operating voltages up to a certain delay length ($\sim$25 μs), after which shorter pulses enabled higher voltages. We then delivered novel H-FIRE waveforms via an actively cooled single-insertion bipolar probe in swine liver in vivo to determine the upper limits to ablation volume possible using a single-needle H-FIRE device. Ablations up to 4.62 $\pm$ 0.12 cm x 1.83 $\pm$ 0.05 cm were generated in 5 minutes without a requirement for cardiac synchronization during treatment. Ablations were minimally thermal, easily visualized with ultrasound, and stimulated an immune response 24 hours post H-FIRE delivery. These data suggest H-FIRE can rapidly produce clinically relevant, minimally thermal ablations with a more user-friendly electrode design.


  • Open Access

    Investigation of High Frequency Irreversible Electroporation for Canine Spontaneous Primary Lung Tumor Ablation

    by Alayna N. Hay, Kenneth N. Aycock, Melvin F. Lorenzo, Kailee David, Sheryl Coutermarsh-Ott, Zaid Salameh, Sabrina N. Campelo, Julio P. Arroyo, Brittany Ciepluch, Gregory Daniel, et al.

    In this study, the feasibility of treating canine primary lung tumors with high-frequency irreversible electroporation (H-FIRE) was investigated as a novel lung cancer treatment option. H-FIRE is a minimally invasive tissue ablation modality that delivers bipolar pulsed electric fields to targeted cells, generating nanopores in cell membranes and rendering targeted cells nonviable. In the current study, canine patients (n = 5) with primary lung tumors underwent H-FIRE treatment with an applied voltage of 2250 V using a 2-5-2 µs H-FIRE waveform to achieve partial tumor ablation prior to the surgical resection of the primary tumor. Surgically resected tumor samples were evaluated histologically for tumor ablation, and with immunohistochemical (IHC) staining to identify cell death (activated caspase-3) and macrophages (IBA-1, CD206, and iNOS). Changes in immunity and inflammatory gene signatures were also evaluated in tumor samples. H-FIRE ablation was evident by the microscopic observation of discrete foci of acute hemorrhage and necrosis, and in a subset of tumors (n = 2), we observed a greater intensity of cleaved caspase-3 staining in tumor cells within treated tumor regions compared to adjacent untreated tumor tissue. At the study evaluation timepoint of 2 h post H-FIRE, we observed differential gene expression changes in the genes IDO1, IL6, TNF, CD209, and FOXP3 in treated tumor regions relative to paired untreated tumor regions. Additionally, we preliminarily evaluated the technical feasibility of delivering H-FIRE percutaneously under CT guidance to canine lung tumor patients (n = 2). Overall, H-FIRE treatment was well tolerated with no adverse clinical events, and our results suggest H-FIRE potentially altered the tumor immune microenvironment.


  • PIRET—A Platform for Treatment Planning in Electroporation-Based Therapies

    by Enric Perera-Bel, Kenneth N. Aycock, Zaid S. Salameh, Mario Gómez-Barea, Rafael V. Davalos, Antoni Ivorra, Miguel A. González Ballester

    Tissue electroporation is the basis of several therapies. Electroporation is performed by briefly exposing tissues to high electric fields. It is generally accepted that electroporation is effective where an electric field magnitude threshold is overreached. However, it is difficult to preoperatively estimate the field distribution because it is highly dependent on anatomy and treatment parameters. Objective: We developed PIRET, a platform to predict the treatment volume in electroporation-based therapies. Methods: The platform seamlessly integrates tools to build patient-specific models where the electric field is simulated to predict the treatment volume. Patient anatomy is segmented from medical images and 3D reconstruction aids in placing the electrodes and setting up treatment parameters. Results: Four canine patients that had been treated with high-frequency irreversible electroporation were retrospectively planned with PIRET and with a workflow commonly used in previous studies, which uses different general-purpose segmentation (3D Slicer) and modeling software (3Matic and COMSOL Multiphysics). PIRET outperformed the other workflow by 65 minutes (× 1.7 faster), thanks to the improved user experience during treatment setup and model building. Both approaches computed similarly accurate electric field distributions, with average Dice scores higher than 0.93. Conclusion: A platform which integrates all the required tools for electroporation treatment planning is presented. Treatment plan can be performed rapidly with minimal user interaction in a stand-alone platform. Significance: This platform is, to the best of our knowledge, the most complete software for treatment planning of irreversible electroporation. It can potentially be used for other electroporation applications.


  • Open Access

    Real-Time Temperature Rise Estimation during Irreversible Electroporation Treatment through State-Space Modeling

    by Sabrina N. Campelo, Edward J. Jacobs, Kenneth N. Aycock, Rafael V. Davalos

    To evaluate the feasibility of real-time temperature monitoring during an electroporation-based therapy procedure, a data-driven state-space model was developed. Agar phantoms mimicking low conductivity (LC) and high conductivity (HC) tissues were tested under the influences of high (HV) and low (LV) applied voltages. Real-time changes in impedance, measured by Fourier Analysis SpecTroscopy (FAST) along with the known tissue conductivity and applied voltages, were used to train the model. A theoretical finite element model was used for external validation of the model, producing model fits of 95.8, 88.4, 90.7, and 93.7% at 4 mm and 93.2, 58.9, 90.0, and 90.1% at 10 mm for the HV-HC, LV-LC, HV-LC, and LV-HC groups, respectively. The proposed model suggests that real-time temperature monitoring may be achieved with good accuracy through the use of real-time impedance monitoring.


  • Experimental and Numerical Investigation of Parameters Affecting High-Frequency Irreversible Electroporation for Prostate Cancer Ablation

    by Kenneth N. Aycock, Ram Anand Vadlamani, Edward J. Jacobs, Khan Mohammad Imran, Scott S. Verbridge, Irving C. Allen, Navid Manuchehrabadi, Rafael V. Davalos

    While the primary goal of focal therapy for prostate cancer (PCa) is conserving patient quality of life by reducing oncological burden, available modalities use thermal energy or whole-gland radiation which can damage critical neurovascular structures within the prostate and increase risk of genitourinary dysfunction. High-frequency irreversible electroporation (H-FIRE) is a promising alternative ablation modality that utilizes bursts of pulsed electric fields (PEFs) to destroy aberrant cells via targeted membrane damage. Due to its nonthermal mechanism, H-FIRE offers several advantages over state-of-the-art treatments, but waveforms have not been optimized for treatment of PCa. In this study, we characterize lethal electric field thresholds (EFTs) for H-FIRE waveforms with three different pulse widths as well as three interpulse delays in vitro and compare them to conventional irreversible electroporation (IRE). Experiments were performed in non-neoplastic and malignant prostate cells to determine the effect of waveforms on both targeted (malignant) and adjacent (non-neoplastic) tissue. A numerical modeling approach was developed to estimate the clinical effects of each waveform including extent of nonthermal ablation, undesired thermal damage, and nerve excitation. Our findings indicate that H-FIRE waveforms with pulse durations of 5 and 10 μs provide large ablations comparable to IRE with tolerable levels of thermal damage and minimized muscle contractions. Lower duration (2 μs) H-FIRE waveforms exhibit the least amount of muscle contractions but require increased voltages which may be accompanied by unwanted thermal damage.


  • A Comparative Modeling Study of Thermal Mitigation Strategies in Irreversible Electroporation Treatments

    by Kenneth N. Aycock, Sabrina N. Campelo, Rafael V. Davalos

    Irreversible electroporation (IRE), also referred to as nonthermal pulsed field ablation (PFA), is an attractive focal ablation modality for solid tumors and cardiac tissue due to its ability to destroy aberrant cells with limited disruption of the underlying tissue architecture. Despite its nonthermal cell death mechanism, application of electrical energy results in Joule heating that, if ignored, can cause undesired thermal injury. Engineered thermal mitigation (TM) technologies including phase change materials (PCMs) and active cooling (AC) have been reported and tested as a potential means to limit thermal damage. However, several variables affect TM performance including the pulsing paradigm, electrode geometry, PCM composition, and chosen active cooling parameters, meaning direct comparisons between approaches are lacking. In this study, we developed a computational model of conventional bipolar and monopolar probes with solid, PCM-filled, or actively cooled cores to simulate clinical IRE treatments in pancreatic tissue. This approach reveals that probes with integrated PCM cores can be tuned to drastically limit thermal damage compared to existing solid probes. Furthermore, actively cooled probes provide additional control over thermal effects within the probe vicinity and can altogether abrogate thermal damage. In practice, such differences in performance must be weighed against the increased time, expense, and effort required for modified probes compared to existing solid probes.


  • Open Access

    An Investigation for Large Volume, Focal Blood-Brain Barrier Disruption with High-Frequency Pulsed Electric Fields

    by Melvin F. Lorenzo, Sabrina N. Campelo, Julio P. Arroyo, Kenneth N. Aycock, Jonathan Hinckley, Christopher B. Arena, John H. Rossmeisl, Rafael V. Davalos

    The treatment of CNS disorders suffers from the inability to deliver large therapeutic agents to the brain parenchyma due to protection from the blood-brain barrier (BBB). Herein, we investigated high-frequency pulsed electric field (HF-PEF) therapy of various pulse widths and interphase delays for BBB disruption while selectively minimizing cell ablation. Eighteen male Fisher rats underwent craniectomy procedures and two blunt-tipped electrodes were advanced into the brain for pulsing. BBB disruption was verified with contrast T1W MRI and pathologically with Evans blue dye. High-frequency irreversible electroporation cell death of healthy rodent astrocytes was investigated in vitro using a collagen hydrogel tissue mimic. Numerical analysis was conducted to determine the electric fields in which BBB disruption and cell ablation occur. Differences between the BBB disruption and ablation thresholds for each waveform are as follows: 2-2-2 μs (1028 V/cm), 5-2-5 μs (721 V/cm), 10-1-10 μs (547 V/cm), 2-5-2 μs (1043 V/cm), and 5-5-5 μs (751 V/cm). These data suggest that HF-PEFs can be fine-tuned to modulate the extent of cell death while maximizing peri-ablative BBB disruption. Furthermore, numerical modeling elucidated the diffuse field gradients of a single-needle grounding pad configuration to favor large-volume BBB disruption, while the monopolar probe configuration is more amenable to ablation and reversible electroporation effects.


  • High-frequency irreversible electroporation brain tumor ablation: exploring the dynamics of cell death and recovery

    by Kelsey R. Murphy, Kenneth N. Aycock, Alayna N. Hay, John H. Rossmeisl, Rafael V. Davalos, Nikolaos G. Dervisis