Latest Publications

  • Kaplan Turbine Model Validation for Large Grid Frequency Disturbances

    by Elin Dahlborg, Per Norrlund, Linn Saarinen

    The grid frequency stability is decreasing in many AC grids due to less inertia in these systems, and their stability is commonly evaluated through simulation. Hydropower often delivers frequency control, yet research on hydropower model validation for large grid frequency disturbances is scarce. We performed frequency control tests on a Kaplan unit and evaluated three models(called the standard grey-box, Kaplan grey-box, and white-box models) against validation data. The grey-box model parameters were identied with grey-box system identication, whereas the white-box model used index test data to relate guide vane opening and runner blade angle to net head, ow, and efciency. All models accounted for steering mechanism backlash. The results showed that the white-box model was overall more reliable than the two grey-box models. However, all models had difculties in simulating the output power the rst few seconds after a large change in frequency. Moreover, backlash sizes had considerable performance impacts on all models. The uncertainties in hydropower model response during the rst few seconds after a disturbance emphasize the importance of sufcient stability margins in grid frequency stability simulations.


  • Allocation of Frequency Control Reserves and Its Impact on Wear and Tear on a Hydropower Fleet

    by Linn Saarinen, Per Norrlund, Weijia Yang, Urban Lundin

    Power systems are making a transition from purely technical, centrally planned systems to market based, decentralized systems. The need for balancing power and frequency control reserves are increasing, partially due to variable renewable production, which gives an opportunity for new incomes but also a challenge in terms of changed modes of operation with risk for reduced life time for controllable power plants. This paper investigates how the allocation of a sold volume of frequency control reserves within a large hydropower production fleet can affect the costs of providing primary and secondary reserves, in terms of its impact on wear and fatigue, production losses and the quality of the delivered frequency control. The results show that for primary control, low static gain in the governors results in poor quality and a large amount of load cycles of the units. High static gain, on the other hand, increases the production losses. The control work of the fleet can be reduced by using a proper balance of primary and secondary control gain on each unit, although the intuitive results from linear models exaggerate this effect. Automatic secondary control improves the system frequency quality but also increases the wear.


  • Open Access

    Correction: Yang, W.; Yang, J.; Guo, W.; Zeng, W.; Wang, C.; Saarinen, L.; Norrlund, P. A Mathematical Model and Its Application for Hydro Power Units under Different Operating Conditions. Energies 2015, 8, 10260–10275

    by Weijia Yang, Jiandong Yang, Wencheng Guo, Wei Zeng, Chao Wang, Linn Saarinen, Per Norrlund

    The authors wish to make the following corrections to the published paper [1].

  • Open Access

    A Mathematical Model and Its Application for Hydro Power Units under Different Operating Conditions

    by Weijia Yang, Jiandong Yang, Wencheng Guo, Wei Zeng, Chao Wang, Linn Saarinen, Per Norrlund

    This paper presents a mathematical model of hydro power units, especially the governor system model for different operating conditions, based on the basic version of the software TOPSYS. The mathematical model consists of eight turbine equations, one generator equation, and one governor equation, which are solved for ten unknown variables. The generator and governor equations, which are different under various operating conditions, are presented and discussed in detail. All the essential non-linear factors in the governor system (dead-zone, saturation, rate limiting, and backlash) are also considered. Case studies are conducted based on one Swedish hydro power plant (HPP) and three Chinese plants. The simulation and on-site measurements are compared for start-up, no-load operation, normal operation, and load rejection in different control modes (frequency, opening, and power feedback). The main error in each simulation is also discussed in detail. As a result, the model application is proved trustworthy for simulating different physical quantities of the unit (e.g., guide vane opening, active power, rotation speed, and pressures at volute and draft tube). The model has already been applied effectively in consultant analyses and scientific studies.