Tianjian Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Tianjian Liu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Haoran Jin
The State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
4 shared publications - Yunjiang Wang
State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China
4 shared publications - Yongjian Zhu
Department of Neurosurgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
3 shared publications - Jingyu Zhang
School of Information Science, Harbin Institute of Technology, Weihai, China
2 shared publications Keji Yang
State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China
2 shared publications- Keji Yang
State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou, China
2 shared publications
Latest Publications
- 7 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (10) , 9119-9126
Ultrasound Robotic System to Multi-Approach Puncture for Endoscopic Spinal Surgery
Ultrasound (US) imaging has been widely utilized for guiding puncture procedures in spinal interventions. However, conventional methods that confine puncture within the US plane may not adequately meet the demands of endoscopic spinal surgery (ESS), which requires extensive spatial orientation adjustments. In this study, we introduce a novel approach using a US robotic system (URS) integrated with a multi-approach puncture mechanism to aid in target localization and puncture assistance during ESS. The proposed mechanism incorporates a five-bar linkage structure with a remote center of motion (RCM) to drive the needle with two degrees of freedom, enabling significant orientation adjustments of 85 $^{\circ }$ in the transverse plane and 140 $^{\circ }$ in the coronal plane. Additionally, the probe holder module provides vertical adaptability of the probe and depth adjustment of the RCM on the US plane. Experimental validation on a cross-wire model demonstrates puncture accuracy of less than 3 mm, meeting clinical requirements for ESS. Furthermore, the system's clinical usability is demonstrated on a gel lumbar model, showcasing the entire process (imaging, targeting, navigating, and puncture assisting) from imaging to puncture assistance. The URS shows promise in significantly improving the puncture success rates in ESS while reducing technical dependencies.
- 7 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (10) , 9119-9126
Ultrasound Robotic System to Multi-Approach Puncture for Endoscopic Spinal Surgery
Ultrasound (US) imaging has been widely utilized for guiding puncture procedures in spinal interventions. However, conventional methods that confine puncture within the US plane may not adequately meet the demands of endoscopic spinal surgery (ESS), which requires extensive spatial orientation adjustments. In this study, we introduce a novel approach using a US robotic system (URS) integrated with a multi-approach puncture mechanism to aid in target localization and puncture assistance during ESS. The proposed mechanism incorporates a five-bar linkage structure with a remote center of motion (RCM) to drive the needle with two degrees of freedom, enabling significant orientation adjustments of 85 $^{\circ }$ in the transverse plane and 140 $^{\circ }$ in the coronal plane. Additionally, the probe holder module provides vertical adaptability of the probe and depth adjustment of the RCM on the US plane. Experimental validation on a cross-wire model demonstrates puncture accuracy of less than 3 mm, meeting clinical requirements for ESS. Furthermore, the system's clinical usability is demonstrated on a gel lumbar model, showcasing the entire process (imaging, targeting, navigating, and puncture assisting) from imaging to puncture assistance. The URS shows promise in significantly improving the puncture success rates in ESS while reducing technical dependencies.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (9) , 5966-5973
Compliant Joint Based Robotic Ultrasound Scanning System for Imaging Human Spine
Robot-assisted ultrasound scanning acquires spatial-property labeled images under high consistency, holding the potential to reconstruct the volume with more intuitive images for examination and surgery guidance. Promisingly, the vertebral level identification, as a time-consuming procedure before spine surgery, can be achieved by robotic ultrasound systems. However, the quality of ultrasound images subjects to the conditions of the examination, including the probe placement, the ultrasound beam incidence angle and the applied contact force. Especially, the spine holds a long and narrow, multi-joint, chain-like structure which is not simply compliant to the probe, presenting challenges to acquire high quality images and keep safety. This letter presents a compliant joint based robotic ultrasound system (CJRUS) for imaging the human spine. A compliant joint based adjusting mechanism (CJAM) is attached to the robotic manipulator to adjust the contact force with patients. A floating scanning strategy is proposed for the manipulator to maintain a buffer zone from the human body and determine the pose of the probe indirectly from the collection of dorsal shape. Phantom experiments concluded that the system could provide inherent safety (the output force was constrained to 20 N by rotary buffer) and adaptive capacity (the settling time was < 1 s for targets with different stiffness and the maximum overshoot decreased 90% in prediction force control) to scanning objects. In human trials, the coronal slice of the reconstructed volume obtained by CJRUS showed comparative results as freehand scanning and equivalent image qualities evaluated by picture contrast and edge gradient. CJRUS is expected to play a significant role in radiation-free navigation of minimally invasive spinal surgery in the future.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (9) , 5966-5973
Compliant Joint Based Robotic Ultrasound Scanning System for Imaging Human Spine
Robot-assisted ultrasound scanning acquires spatial-property labeled images under high consistency, holding the potential to reconstruct the volume with more intuitive images for examination and surgery guidance. Promisingly, the vertebral level identification, as a time-consuming procedure before spine surgery, can be achieved by robotic ultrasound systems. However, the quality of ultrasound images subjects to the conditions of the examination, including the probe placement, the ultrasound beam incidence angle and the applied contact force. Especially, the spine holds a long and narrow, multi-joint, chain-like structure which is not simply compliant to the probe, presenting challenges to acquire high quality images and keep safety. This letter presents a compliant joint based robotic ultrasound system (CJRUS) for imaging the human spine. A compliant joint based adjusting mechanism (CJAM) is attached to the robotic manipulator to adjust the contact force with patients. A floating scanning strategy is proposed for the manipulator to maintain a buffer zone from the human body and determine the pose of the probe indirectly from the collection of dorsal shape. Phantom experiments concluded that the system could provide inherent safety (the output force was constrained to 20 N by rotary buffer) and adaptive capacity (the settling time was < 1 s for targets with different stiffness and the maximum overshoot decreased 90% in prediction force control) to scanning objects. In human trials, the coronal slice of the reconstructed volume obtained by CJRUS showed comparative results as freehand scanning and equivalent image qualities evaluated by picture contrast and edge gradient. CJRUS is expected to play a significant role in radiation-free navigation of minimally invasive spinal surgery in the future.
- 26 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (2) , 426-435
A Flexible Ultrasound Scanning System for Minimally Invasive Spinal Surgery Navigation
Minimally invasive surgery has become the primary treatment of spine disease. It depends on high-precision medical image as guidance. Ultrasound imaging is expected to replace X-ray fluoroscopy as a golden standard scheme of minimally invasive spinal surgeries. Researchers make effort to develop ultrasound imaging for the process of navigation, taking its distinctive advantages of user-friendly and radiation-free. However, it is greatly affected by the contact force and incident angle of the probe, which depends a lot on experienced sonographers. To this end, a flexible ultrasound scanning system (FUSS) is proposed to automatically image the human spine. In mechanics, a flexible fixture, fixed on the end joint of robotic arm, is designed to ensure the ultrasound probe to be pressed against the dorsal skin. Besides, decoupled control strategy is presented which decouples trajectory planning task and force control task into separate joint space. By this means, the possibility of accidental damage could be minimized. Phantom experiments were carried out to validate the hysteresis characteristic of flexible fixture, the capacity to resisting impact, the performance of control system and the quality of reconstruction image. These results show that our system has high safety performance and could keep the probe force stable within the range of 1 N to obtain better reconstruction image than freehand scanning. In summary, it has a great potential on navigation of spine surgery.
- 26 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (2) , 426-435
A Flexible Ultrasound Scanning System for Minimally Invasive Spinal Surgery Navigation
Minimally invasive surgery has become the primary treatment of spine disease. It depends on high-precision medical image as guidance. Ultrasound imaging is expected to replace X-ray fluoroscopy as a golden standard scheme of minimally invasive spinal surgeries. Researchers make effort to develop ultrasound imaging for the process of navigation, taking its distinctive advantages of user-friendly and radiation-free. However, it is greatly affected by the contact force and incident angle of the probe, which depends a lot on experienced sonographers. To this end, a flexible ultrasound scanning system (FUSS) is proposed to automatically image the human spine. In mechanics, a flexible fixture, fixed on the end joint of robotic arm, is designed to ensure the ultrasound probe to be pressed against the dorsal skin. Besides, decoupled control strategy is presented which decouples trajectory planning task and force control task into separate joint space. By this means, the possibility of accidental damage could be minimized. Phantom experiments were carried out to validate the hysteresis characteristic of flexible fixture, the capacity to resisting impact, the performance of control system and the quality of reconstruction image. These results show that our system has high safety performance and could keep the probe force stable within the range of 1 N to obtain better reconstruction image than freehand scanning. In summary, it has a great potential on navigation of spine surgery.
- 14 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (1) , 570-581
Self-Adaptive Ultrasound Scanning System for Imaging Human Spine
Ultrasound imaging as a user-friendly and radiation-free navigation scheme has been gradually applied to minimally invasive spinal surgeries. However, acquiring an interpretable ultrasound image always requires experienced sonographers, which dramatically restricts its applications. To this end, in this article, a self-adaptive ultrasound scanning system (SAUSS) is proposed to image the human spine. This system automatically scans human back and real-time displays the spine structure. During scanning, our self-adaptive attitude-adjusting mechanism ensures the scan posture of the ultrasound probe, and guarantees human comfort and ultrasound coupling at the same time. According to the phantom experiments, our proposed system can maintain the resultant force in an appropriate region from 14 to 16 N on different segments of the spine and under different respiratory rates. Meanwhile, the automatically scanned image achieves higher quality and better repeatability than freehand one. In human trials, the image provided from SAUSS keeps clear image textures that are almost on par with computed tomography (CT) images, and its stability is also demonstrated from the comparisons of force fluctuations. In all, it has a great potential on navigation of spine surgery.
- 14 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (1) , 570-581
Self-Adaptive Ultrasound Scanning System for Imaging Human Spine
Ultrasound imaging as a user-friendly and radiation-free navigation scheme has been gradually applied to minimally invasive spinal surgeries. However, acquiring an interpretable ultrasound image always requires experienced sonographers, which dramatically restricts its applications. To this end, in this article, a self-adaptive ultrasound scanning system (SAUSS) is proposed to image the human spine. This system automatically scans human back and real-time displays the spine structure. During scanning, our self-adaptive attitude-adjusting mechanism ensures the scan posture of the ultrasound probe, and guarantees human comfort and ultrasound coupling at the same time. According to the phantom experiments, our proposed system can maintain the resultant force in an appropriate region from 14 to 16 N on different segments of the spine and under different respiratory rates. Meanwhile, the automatically scanned image achieves higher quality and better repeatability than freehand one. In human trials, the image provided from SAUSS keeps clear image textures that are almost on par with computed tomography (CT) images, and its stability is also demonstrated from the comparisons of force fluctuations. In all, it has a great potential on navigation of spine surgery.